• 제목/요약/키워드: double core probe

검색결과 5건 처리시간 0.027초

Review paper: Application of the Pulsed Eddy Current Technique to Inspect Pipelines of Nuclear Plants

  • Park, D.G.;Angani, C.S.;Kishore, M.B.;Vertesy, G.;Lee, D.H.
    • Journal of Magnetics
    • /
    • 제18권3호
    • /
    • pp.342-347
    • /
    • 2013
  • Local wall thinning in pipelines affects the structural integrity of industries, such as nuclear power plants (NPPs). In the present study, a development of pulsed eddy current (PEC) technology that detects the wall thinning of pipelines covered with insulation is reviewed. The methods and experimental results, which have two kinds of probe with a single and double core, were compared. For this purpose, the single and double core probes having one and two excitation coils have been devised, and the differential probe with two Hall sensors has been fabricated to measure the wall thinning in insulated pipelines. The test sample is a stainless steel having different thickness, laminated by plastic insulation to simulate the pipelines in NPPs. The excitation coils in the probe is driven by a rectangular current pulse, the difference of two Hall sensors has been measured as a resultant PEC signal. The peak value of the detected signal is used to describe the wall thinning. The double core probe has better performance to detect the wall thinning covered with insulation; the single core probe can detect the wall thinning up to an insulation thickness of 18 mm, whereas the double probe can detect up to 25 mm. The results show that the double core PEC probe has the potential to detect the wall thinning in an insulated pipeline of the NPPs.

Double clad fiber probe for fluorescence spectroscopy

  • Wang, Ling;Lee, Byeong-Ha
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2007년도 하계학술발표회 논문집
    • /
    • pp.35-36
    • /
    • 2007
  • We report a probe using a single double clad fiber (DCF) for fluorescence spectroscopy. Bidirectional separate transmission for excitation and fluorescence light in a single fiber was implemented. A DCF coupler made by side-polished method could extract none but the collected fluorescence signals propagating in inner cladding mode, thereby diminishing the interference of silica background generated by the excitation in core mode. The experimental results show that the fluorescence spectra of biological tissues obtained using the DCF probes have much less silica background than using a standard multiple-mode fiber.

  • PDF

Graphene Coated Optical Fiber SPR Biosensor

  • Kim, Jang Ah;Hwang, Taehyun;Dugasani, Sreekantha Reddy;Kulkarni, Atul;Park, Sung Ha;Kim, Taesung
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2014년도 제46회 동계 정기학술대회 초록집
    • /
    • pp.401-401
    • /
    • 2014
  • In this study, graphene, the most attractive material today, has been applied to the wavelength-modulated surface plasmon resonance (SPR) sensor. The optical fiber sensor technology is the most fascinating topic because of its several benefits. In addition to this, the SPR phenomenon enables the detection of biomaterials to be label-free, highly sensitive, and accurate. Therefore, the optical fiber SPR sensor has powerful advantages to detect biomaterials. Meanwhile, Graphene shows superior mechanical, electrical, and optical characteristics, so that it has tremendous potential to be applied to any applications. Especially, grapheme has tighter confinement plasmon and relatively long propagation distances, so that it can enhance the light-matter interactions (F. H. L. Koppens, et al., Nano Lett., 2011). Accordingly, we coated graphene on the optical fiber probe which we fabricated to compose the wavelength-modulated SPR sensor (Figure 1.). The graphene film was synthesized via thermal chemical vapor deposition (CVD) process. Synthesized graphene was transferred on the core exposed region of fiber optic by lift-off method. Detected analytes were biotinylated double cross-over DNA structure (DXB) and Streptavidin (SA) as the ligand-receptor binding model. The preliminary results showed the SPR signal shifts for the DXB and SA binding rather than the concentration change.

  • PDF

괴산지역 시추공 지하수의 자연방사성물질 산출특성과 지화학적 기원 (Geochemical Origins and Occurrences of Natural Radioactive Materials in Borehole Groundwater in the Goesan Area)

  • 김문수;양재하;정찬호;김현구;김동욱;조병욱
    • 지질공학
    • /
    • 제24권4호
    • /
    • pp.535-550
    • /
    • 2014
  • 지하수내 존재하고 있는 자연방사성물질인 우라늄과 라돈-222의 산출특성과 지화학적 기원을 알아보기 위해 괴산지역 연구부지내 120 m 깊이의 지하수 관정을 시추하여 심도별 시추코어의 암석화학적 특성과 지하수의 화학적 특성을 분석하였다. 시추코어 샘플 분석과 함께 더블패커시스템과 베일러를 이용하여 8개의 심도별 지하수 시료를 채취하여 지화학적 특성 분석을 수행하였다. 시추코어 분석결과, 주요 암종은 화강반암과 점판암이었으며 일부 구간에서는 탄산염암과 석회규산염암, 페그마타이트가 확인되었다. 심도별 지하수의 pH는 7.8~8.4의 범위이며, 화학적 유형은 Na-$HCO_3$형태를 보였다. 암석 및 광물 내 우라늄과 토륨의 함량은 각각 < 0.2~14.8 ppm과 0.56~45.0 ppm의 범위였으며, 암석현미경과 전자현미경(EPMA) 관찰 결과 자연방사성원소(우라늄) 함유 광물은 흑운모내 포획된 모나자이트 광물인 것으로 확인되었다. 우라늄은 이들 광물의 주요 구성원소를 치환하여 존재하는 것으로 보이며 파쇄대와 같은 주요 대수층 구간에서 용해되어 지하수와 함께 용출되는 것으로 보인다. 라돈-222의 함량은 우라늄의 함량과 어떠한 상관성을 보이지 않았으며 향후, 라돈가스 기원 추적을 위해서는 헬륨과 네온 등 영족기체 동위원소비를 이용한 간접적인 방법을 적용하여 분석할 필요가 있을 것으로 판단된다.

청원지역 시추공 지하수의 수리화학 및 자연방사성물질 산출 특성 (Hydrochemistry and Occurrence of Natural Radioactive Materials within Borehole Groundwater in the Cheongwon Area)

  • 정찬호;김문수;이영준;한진석;장효근;조병욱
    • 지질공학
    • /
    • 제21권2호
    • /
    • pp.163-178
    • /
    • 2011
  • 이 연구에서는 지하수내 존재하는 우라늄과 라돈-222와 같은 자연방사성물질 산출과 지화학적 상관관계를 알아보기 위하여 연구용 부지(충북 청원군 부용면 갈산리)에 120 m 심도로 시추하고, 심도별로 채취된 지하수의 화학적 특성과 시추코어의 암석화학적 특성을 분석하였다 시추코어상 주요 암종은 흑운모편암과 흑운모화강암이며 일부 구간에서 반상화강암과 염기성암맥이 확인되었다. 더블패커 시스템으로 채취한 6개 구간에서 지하수의 pH는 5.66~8.34 범위를 보이고, 화학적 유형은 Ca-$HCO_3$ 형으로 속한다. 심도별 및 시기별로 수리화학적 특성 차이를 보인다. 지하수내 우라늄과 라돈-222의 함량은 최고 683 ppb와 7,600 pCi/L를 각각 보이며, 심도 50~70 m구간에서 가장 높은 값을 보인다. 암석 및 광물내 우라늄과 토륨의 함량은 각각 0.51~23.4 ppm과 0.89~62.6 ppm의 범위를 보이며, 흑운모편암에서 가장 많은 방사성포유물(radioactive inclusion)이 관찰되었고, 현미경관찰과 EPMA 분석결과 방사성원소를 함유하는 광물로는 흑운모내 함유된 소량광물인 모나자이트, 일메나이트로 확인되었다. 우라늄은 이들 광물의 주요 구성원소를 치환하여 존재하며, 일부 석영과 장석 입자내에도 우라늄의 산출이 확인되었다. 시추공 심도 -50~-70 m 구간 지하수에서 높은 방사성물질 함량을 보이는 것은 이 구간의 지하수의 화학적 특성, 즉, 약알칼리성의 pH와 산화환경이고, 중탄산의 함량이 높아 우라늄의 용존에 좋은 조건이 된 것으로 보인다. 지하수내 라돈가스의 함량은 우라늄 농도와 대체로 비례하므로 우라늄의 붕괴와 관련된 것으로 보이며, 라돈가스의 기원에 대한 하나의 해석방법으로 헬륨과 네온등 영족기체 동위원소비를 이용한 간접적인 추적방법을 적용할 필요가 있을 것이다.