• Title/Summary/Keyword: domestic accidents

Search Result 644, Processing Time 0.021 seconds

A Study on Validation for Mapping of Gas Detectors at a BTX Plant (BTX 공정에서 Gas Detector Mapping 적정성 검토에 관한 연구)

  • Seo, Ji Hye;Han, Man Hyoeng;Kim, Il Kwon;Chon, Young Woo
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.5
    • /
    • pp.168-178
    • /
    • 2017
  • In order to prevent major and chemical accidents, some of the plants which would like to install and operate hazard chemicals handling facilities must submit Off-site Consequence Analysis due to recent arisen leak accidents since 2015. A lot of chemical industrials choose gas detectors as mitigation equipment to early detect gas vapor. The way of placement of gas detectors has two methods; Code-based Design(CBD) and Performance-based Design. The CBD has principles for gas detectors to be installed with consideration for the place that is expected to accumulate gas, and the leak locations according to legal standards and technical guidelines, and has a possibility to be unable to detect by these rules to locate gas detectors by vapor density information. The PBD has two methods; a Geographic Method and Scenario based Method. The Scenario-based Method has been suggested to make up for the Geographic Coverage Method. This Scenario-based Method draw the best optimum placement of gas detectors by considering leak locations, leak speed information, leak directions and etc. However, the domestic placement guidelines just refers to the CBD. Therefore, this study is to compare existing placement location of gas detectors by the domestic CBD with placement locations, coverages and the number of gas detectors in accordance with the Scenario-based Method. Also this study has measures for early detecting interest of Vapor Cloud and suitable placement of gas detectors to prevent chemical accidents. The Phast software was selected to simulate vapor cloud dispersion to predict the consequence. There are two cases; an accident hole size of leak(8 mm) from API which is the highst accident hole size less than 24.5 mm, and a normal leak hole size from KOSHA Guide (1.8 mm). Detect3D was also selected to locate gas detectors efficiently and compare CBD results and PBD results. Currently, domestic methods of gas detectors do not consider any risk, but just depend on domestic code methods which lead to placement of gas detectors not to make personnels recognize tolerable or intolerable risks. The results of the Scenario-based Method, however, analyze the leak estimated range by simulating leak dispersion, and then it is able to tell tolerable risks. Thus it is considered that individuals will be able to place gas detectors reasonably by making objectives and roles flexibly according to situations in a specific plant.

Hazardous and Noxious Substances(HNS) Risk Assessment and Accident Prevention Measures on Domestic Marine Transportation (국내 위험·유해물질(HNS) 해상운송사고 위험도 분석 및 사고 저감방안 연구)

  • Cho, Sim-Jung;Kim, Dong-Jin;Choi, Kang-Sik
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.19 no.2
    • /
    • pp.145-154
    • /
    • 2013
  • HNS, including crude oil and products, shipments have increased. The risk analysis of HNS has assumed the importance, especially in maritime transportation area. There are various forms and kinds of HNS and the consequences of an accident are serious. In order to provide practical measures for preventing accidents, this study analyses the potential risks of HNS on maritime transportation accidents at domestic sea by using Event Tree Analysis. This study carries out risk assessment with F-N curve and risk matrix focusing on liquid cargo carriers (Oil and Products Tanker, Chemical Tanker, LPG/LNG Tanker, etc.). Explosion and sinking, suffocation indicate high consequence when on collision represent high probability. Improving human errors should be the main factor to mitigate risk on human lives.

The Safety Design of Corrosive Chemical Handling Process based on Reliability Database (신뢰도 데이터베이스 기반 부식성 화학물질 취급공정의 안전설계)

  • Chu, Chang Yeop;Baek, Jong Bae
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.5
    • /
    • pp.141-149
    • /
    • 2018
  • In a PCB factory, there is a corrosive chemical substance supply system that can causes major leakage accidents. These accidents can give rise to shut down the factory and do residents damage that cause enormous loss of properties. To mitigate these risks, it is necessary to provide a chemical disaster prevention system. Moreover, after considering the situation and environment of the production site, it is of great importance to build an optimal chemical accident prevention system by reflecting risk reduction measures from the point of process design and by assessing quantitative risk based on reliability data. However, because there was no established database of the reliability about facilities and equipment that can be used in the domestic, the business site and consulting organization had being used the reliability data such as USA CCPS(Center for Chemical Process Safety). In these days, Korean institutes are studying on reliability data utilization method of quantitative risk assessment for preventing chemical accidents and domestic utilization algorithms and storage bed of reliability data. This study presents samples of reliability database about the chemical substance supply system that constructed from the history data such as failure, maintenance for 10 years at a PCB factory. Also, this work proposes the safety design criteria for supply facilities of corrosive chemical substance by assessing quantitative risk on the basis of the reliability data.

Accidents Analysis of Domestic and Overseas Refueling Stations and Assessment of Dangerous Distance by Gas Leak (국내·외 충전소 사고 현황 분석 및 가스누출 피해거리 평가)

  • Kim, Hyelim;Kang, SeungKyu;Huh, YunSil
    • Journal of Energy Engineering
    • /
    • v.26 no.4
    • /
    • pp.7-13
    • /
    • 2017
  • As environmental problems become a problem of survival, interest in eco-friendly energy is increasing to improve the environment. So, demand for eco-friendly fuels such as hydrogen, LPG and CNG is increasing. In particular, Korea, which relies on imports of most fuels, is investing in the development of hydrogen energy, which is favorable in terms of high production volume and energy independence. However, As demand grows every year, a variety of accidents occur in various ways, ranging from small leak incidents to massive fires and explosion, thus research needs to be done. So, in this study, compared and analyzed cases of hydrogen, LPG, CNG accidents occurring at domestic and overseas refueling stations. and various programs were used for assessing risk, estimated the flame length due to gas leakage and evaluated the dangerous distance.

Analysis of Electric Shock Accidents and Check Results in Domestic and Foreign low-Voltage Handhole (국내.외 저압지중함 감전사고사례 및 점검결과의 분석)

  • Kim, Chong-Min;Han, Woon-Ki;Bang, Sun-Bae;Kim, Han-Sang;Shim, Keon-Bo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.1
    • /
    • pp.124-131
    • /
    • 2008
  • Recently underground electrical power distribution is increased because people attach importance to aesthetics of the downtown areas. Lew-voltage handhole of underground distribution line for joint and branch point is mainly installed at the sidewalk. So, pedestrian can get a electric shock if fault is occurred in the low-voltage handhole. Furthermore the street was flooded by recently an unusual change in the weather. Fault is occurred in the low-voltage handhole that may create a shock hazard for the human body because a person's body resistance lower due to effect of water. This paper analyses causes of electric shock accidents and check results at the low-voltage handhole. At a result of analysis, the causes of electric shock accidents in domestic and foreign low-voltage handhole are same but environmental conditions of low-voltage handhole are different In the future, the analytical data can be applied to prevent the electric shock at the low-voltage handhole, and can be used to basic data for the improving installment of low-voltage handhole.

Evaluation on th e Wear Fit and Activity of Emergency Escape Breathing Devices for Ship Accidents (선박사고용 호흡구난장비의 착용성 및 활동성 평가 연구)

  • Noh, Jae-Hyeon;Park, Yong-Hwan
    • Fire Science and Engineering
    • /
    • v.33 no.2
    • /
    • pp.79-84
    • /
    • 2019
  • The use of emergency escape breathing devices (EEBD) is strongly required to protect against toxic gas or flooding caused by ship fires or accidents. Recently developed domestic EEBD products only satisfy the basic performance requirements, but no wear fit and activity performance evaluation has been done for real usage. In this study, the global level test requirements for wear comfort and activity of EEBDs were developed and the open and closed type of domestic EEBD products were evaluated. Poor visibility, longer wear time, breathing resistance, and hose obstruction in an open type and canister obstruction, weight unbalance, and an invisible black breathing bag in the closed type EEBD were estimated to be the main problems that need to be improved.

A Study on the Improvement of Safety Management by Analyzing the Current Status and Response System of Forest Fire Accidents (산불사고 현황과 대응체계 분석을 통한 안전관리 개선방안 연구)

  • Jeong, Kyung-ok;Kim, Dae-jin
    • Journal of the Society of Disaster Information
    • /
    • v.18 no.3
    • /
    • pp.457-469
    • /
    • 2022
  • Purpose: The purpose of this study is to present the direction of improvement of safety management by reviewing the current status of forest fire accidents that are becoming larger throughout the year and the problems of the response system. Method: Domestic and foreign literature survey and statistics of recent forest fire accidents by Statistics Korea investigated and analyzed the cause, number of damage, and suggested ways to improve forest fire safety management through domestic and foreign forest fire response systems. Result: Through the analysis of the causes of recent wildfires and overseas response cases, measures to improve the safety management of wildfires in terms of hardware, software, and humanware were derived. Conclusion: The plan to improve forest fire safety management was classified into three main categories and presented, and it should be embodied through further related research.

Feasibility Study on Cross-tie Systems in Nuclear Power Plants Using Multi-unit PSA (다수기 PSA를 활용한 원전 안전자원 공유 활용성 평가)

  • Jong Woo Park;Ho-Gon Lim;Jae Young Yoon
    • Journal of the Korean Society of Safety
    • /
    • v.38 no.3
    • /
    • pp.102-109
    • /
    • 2023
  • Following the accident at Fukushima, the true impact of multi-unit accidents came to light. Accordingly, research related to multi-unit accident effect analysis, risk evaluation, and accident prevention/prevention technology has been conducted. Specific examples are mobile/fixed equipment such as multi-barrier accident coping strategy (MACST) and diverse and flexible coping strategies (FLEX), which have been introduced and installed in multi-units for preventing and mitigating multi-unit accidents. These strategies are useful for enhancing the safety of nuclear power plants (NPPs); however, a more efficient strategy is required in terms of the costs of physical and human resources. To effectively and efficiently mitigate an increase in multi-unit accidents, it is necessary to not only to utilize mobile/fixed equipment but to also use crosstie options with resources that already exist at NPPs. Therefore, we analyzed the current international and domestic status of crosstie systems technology and propose a method to evaluate feasibility alongside risk based on a multi-unit probabilistic safety assessment (PSA). To analyze the international and domestic status of crosstie systems technology, actual cases and related research were studied, and a list of potential crosstie safety resources was derived. Additionally, a case study was performed on crosstie cases of two systems within the assumed six units on-site under a multi-unit accident, and a multi-unit PSA-based risk evaluation method is proposed.

A Study on Improvement of Domestic Airport Service for Rescue and Fire Fighting (국내 공항 구조 및 소방 업무 개선방안 연구)

  • Han, Jae-Hyun;Chung, Ki-Yeon
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.16 no.4
    • /
    • pp.69-74
    • /
    • 2008
  • Aircraft fires due to accident at an airport may be under a special situation. An outstanding characteristic of aircraft fires is their tendency to reach lethal intensity within a very short time. In domestic aviation act, there are regulations related to services coping with the aircraft accidents within an airport. To cope aircraft fires, it is necessary to define clearly the regulations and standards about the services and related activities of rescue and fire fighting, and to keep the regulations and standards. The study has been performed on the basis of International Civil Aviation Organization (ICAO) Airport Services Manual of rescue and fire fighting. The objective of study is to suggest improvement methods for standards applicable to actual service practices of rescue and fire fighting by analyzing through the comparison of domestic and international regulations and standards.

  • PDF

A Study on Improvement for a Flight Instructor Rating (조종사 조종교육증명 한정심사 개선 방안에 관한 연구)

  • Kim, Kwang-Joong;Maeng, Sung-Kyu;Yoo, Byeong-Seon
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.20 no.1
    • /
    • pp.55-65
    • /
    • 2012
  • An airman licensing system is central to the establishment and management of a state's airman licensing which gives official privileges to a person to perform specific activities by evaluating applicant's knowledge and proficiency. In recent decades, the level of the domestic aviation industry continues to leap forward and state's airman licensing system has also been advanced. However, accidents caused by pilot human errors are still occurring. In particular, the pilot occupations require a lot of experience and knowledge and the student pilots receiving the initial flight training have formed their own flight habits based on knowledge, skill, training methods, procedures, etc learned from the flight instructor. This paper discusses possible ways on the improvement for the domestic flight instructor rating by analyzing domestic and international rules and procedures for a flight instructor rating.