• 제목/요약/키워드: documentary assessment

검색결과 21건 처리시간 0.023초

농촌마을종합개발사업 중간 점검을 위한 평가지표 적용사례 (Development of An Evaluation System for the Interim Check of Integrated Rural Village Development Project)

  • 한경수;김기현;전택기;엄대호;최윤상
    • 농촌계획
    • /
    • 제13권2호
    • /
    • pp.121-132
    • /
    • 2007
  • In this study, We developed an evaluation system for the interim check of Integrated Rural Village Development Project and analyzed its applicability to an actual evaluation process through a pilot evaluation on regions selected. The evaluation system consists of documentary assessments(30%) and field inspections(70%). The documentary assessments are quantitative assessments on check-lists reports by self-evaluation prepared by local governments. The field inspections are qualitative assessments by evaluation teams. Sixteen evaluation indices were developed for documentary assessments and seven criteria were designed for field inspections. For a pilot evaluation, one region in each province excluding Jeju Do, eight regions was selected and the field inspections due to circumstances was proceeded in two regions. The results of documentary assessments indicate that most of regions are evaluated low in project performance attributable to the delay in security for sites. In the field inspections, it appears that most of the regions evaluated high at the documentary assessments got a high point from them. They also show that coordination of action plans, rather than quantitative achievements, is a base determining success of the projects.

Risk Assessment in the UK Health and Safety System: Theory and Practice

  • Russ, Karen
    • Safety and Health at Work
    • /
    • 제1권1호
    • /
    • pp.11-18
    • /
    • 2010
  • In the UK, a person or organisation that creates risk is required to manage and control that risk so that it is reduced 'So Far As Is Reasonably Practicable (SFAIRP).' How the risk is managed is to be determined by those who create the risk. They have a duty to demonstrate that they have taken action to ensure all risk is reduced SFAIRP and must have documentary evidence, for example a risk assessment or safety case, to prove that they manage the risks their activities create. The UK Health and Safety Executive (HSE) does not tell organisations how to manage the risks they create but does inspect the quality of risk identification and management. This paper gives a brief overview of where responsibility for occupational health and safety lies in the UK, and how risk should be managed through risk assessment. The focus of the paper is three recent major UK incidents, all involving fatalities, and all of which were wholly avoidable if risks had been properly assessed and managed. The paper concludes with an analysis of the common failings of risk assessments and key actions for improvement.

송전선로 직접활선공법의 위험요인과 안전대책에 관한 연구 (A Study on the Hazard Factor and Safety Management at Transmission Line During Live Line Works)

  • 최승동;강경식
    • 대한안전경영과학회지
    • /
    • 제8권3호
    • /
    • pp.51-66
    • /
    • 2006
  • This study was attempted to analyze risk factors and suggest accident prevention in live line works for power transmission lines to be developed and applied in Korea. Safety problem cannot but occur at development of live line works and application to the field. With respect to this, problems likely to occur in the field among works adopting methods of works including live line works for power transmission lines were investigated and analyzed through documentary survey and risk assessment method. The results are summarized as follows. A risk assessment method model was suggested. This method enables scientific and systematic development of safety control. That is, the owner may autonomously induce safety control and build risk assessment database by work process to use them as best training data for workers. Also, in the field, it may induce all workers to participate in safety program and secure safety by making workers seek for safety working method under smooth flow from looking at risk factors to accident prevention activities. It is deemed that this humble study will prevent both accident and injury likely to occur in live line works for power transmission lines.

유아교육시설 내 실내공기유해오염물질에 대한 어린이 건강위해성평가 (Childrens' Health Risk Assessment on Indoor Hazardous Air Pollutants of Preschool Facility)

  • 고연정;김신도;박숙영;장성기
    • 한국환경보건학회지
    • /
    • 제35권2호
    • /
    • pp.78-85
    • /
    • 2009
  • In this study, the hazard rate of the indoor environment of Children's Educational Facilities in Seoul was conducted, in order to determine how the indoor environments of these facilities, where infants and children spend the most time of their away from home day, can effect their health. The way of measurement and analysis were done according to the Indoor Air Quality Standard Method, and the Risk Assessment was accomplished with several significant ways - Hazard Identification, Exposure Assessment, Dose-response Assessment, Risk Characterization, which are deighed by National Research Council (NRC). On each exposure factors, documentary and questionary research such as Epidemiological study and Toxicological study were conducted. The result of the CTE (Central tendency exposure) of Formaldehyde and Benzene by Monte-Carlo simulation was $6.79{\times}10^{-6}$, $2.50{\times}10^{-7}$ which in the case of Formaldehyde exceeded the permitted standard ($10^{-6}$) of the US EPA. The RME(Reasonable maximum exposure) was $7.31{\times}10^{-5}$, $2.65{\times}10^{-6}$ which did not exceed $10^{-4}$, the maximum permitted standards in the US EPA.

중학교 수학과 수행평가의 문제점 분석 및 그 해결 방안 연구 (Problem Analysis and Study of Solution Device in Relation with Middle School Mathematics Performance Assessment)

  • 박재용
    • 한국학교수학회논문집
    • /
    • 제3권1호
    • /
    • pp.149-163
    • /
    • 2000
  • The Ministry of Education have had us practice the performance test as a substitute proposal, however, all the more for the idealistic purport, our education front does not have such a sufficient condition as to practice the performance test for many classes and miscellaneous duties and over-populated class, and that practice has been enforced so abruptly without any drastic preparation and has caused much confusion from the beginning of that enforcement. Thus, these problematic concerns are remained as the tasks of the teachers to be solved by themselves in the front of education, and herein I came to do this research. The followings are the conclusions that I got as the results of the research (1) Performance test style should be applied in consideration of the students' achievement level and the gap of the teachers' recognition; descriptive test, portfolio assignment and formative test styles were proper for the students lacking basic study ability. (2) Descriptive test should have its beginning with the question items to which students can write the problem solving procedure logically rather than those to evaluate the creation ability and thinking ability: and putting down specifically the assessment standard could prevent students' confusion and scheme the impartiality of the assessment. (3) Portfolio assignment evaluation should be given with as interesting and suitable amounts as possible so that the students can do by themselves. (4) Utilizing the performance test table enabled easy management of documentary evidence. And it is needless to say that the success of the performance test should have preceding conditions like the teachers' understanding and their positive participation. Therefore, I'd like to give suggestions herein like the followings; (1) The performance test should not always be made into grades, and there is a need to develop the test gradually in the condition that the education surroundings permit by checking time, frequency, ratio and contents of the test while practicing the multiple choice writing test. (2) As long as the performance test has the aims of improving the studying and learning activities, any performance test only for the sake of making numerals with the thought that assessment is the disposal of the grades should be avoided, and the change of the lecturing styles and development of various assessing types and studying materials should be endeavored to confirm with the aims.

  • PDF

Review on Historical Assessment and Perception of Dziga Vertov

  • Jeon, Pyoung-Kuk
    • International Journal of Contents
    • /
    • 제4권4호
    • /
    • pp.24-29
    • /
    • 2008
  • In 1920s, Soviet silent films enjoyed unprecedentedly great prosperity throughout world film history. Particularly, Dziga Vertov could develop 'montage' in collaboration with Sergei Eisenstein and thereby could work as the engines behind development and leap of Soviet films toward 'new concepts' of 'new films' worldwide. However, Vertov's original reputations - the best film theorist and avant-gardist as well as great cineaste in his contemporary age - have been misunderstood or underestimated, so that he has been still misestimated or distorted as radical formalist and documentary propagandist. In regard to these points, this study aims to take Gilles Deleuze's modal esthetic approaches to further considering and historically re-highlighting D. Vertov's film theories that are based on the principle of 'film-reality' and the concept of 'Life As It Is' according to 'kino-eye' method and 'interval' theory as a part of futurism and constructivism breaking down any attribute of traditional narrative films.

단양지역 붕적토 붕괴사면의 안정평가 (Slope Stability Assessment for Colluvial Soil Slumps of the Danyang Region)

  • 배우석;이봉직;장광택
    • 한국안전학회지
    • /
    • 제22권3호
    • /
    • pp.74-80
    • /
    • 2007
  • In this study, a documentary survey, face mapping, and stability analysis were performed on the collapsed colluvial soil slope. The purpose of this paper is to identify the cause of slope failure and determine slope stability for similar areas. Boring samples were extracted from the slump and laboratory tests were performed to find out the cause of slope failure. In addition, the limit equilibrium method was used in order to determine the stability of the slope. As a result of this investigation and the analysis of data, the type of collapse and cause of slope failure have been shown to have a strong correlation with the natural geographical and geological features which make up the collapse profile of the study area. These results will help to develop guidelines for formulating countermeasure methods.

U-Eco City 적용기술의 평가항목 도출 (Deduction of Assessment Items about Applied Technologies in U-Eco City)

  • 김지현;김호기
    • 한국콘텐츠학회논문지
    • /
    • 제10권6호
    • /
    • pp.115-133
    • /
    • 2010
  • 국내의 여러 지자체와 신도시에서는 U-Eco City를 구축 계획 중에 있으며 정보통신 기술의 발달에 힘입어 다양한 서비스와 기술이 적용되고 있다. 그러나 U-Eco City 사업이 활발히 추진되는데 반하여 기술적용의 객관성 검증을 위한 연구는 매우 드문 실정이다. 본 논문에서는 U-Eco City에 적용되는 기술의 결정을 위한 기술평가를 목적으로, U-Eco City의 분야별 기술을 검토하고 분야별 기술의 평가항목을 도출하고자 하였다. 이를 위하여 분야별 기술의 진화과정과 기존의 U-Eco City 기술분류체계를 살펴보고, 개별 기술의 미래적 방향성을 탐지함으로써 장기적 활용이 가능한 U-Eco City 기술평가항목을 제시하였다. 연구 결과 U-Eco City 기술은 정보 수집기술(센서, 상황인지, 영상인지, 위치인식 기술), 정보 가공기술(임베디드 S/W 기술), 정보 활용 기술(네트워크 기술) 등 총 6개 분야로 제시되었으며, 이들 기술의 분야별 평가항목을 도출하였다.

Technical Approaches for Assessment of Ground Water Contamination with TCE in an Industrial Area

  • Jeon, Kweonho;Yu, Soonyoung;Jeong, Jangsik;Son, Yanglae
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2003년도 International Symposium
    • /
    • pp.70-86
    • /
    • 2003
  • Despite its usability, TCE has been managed as a hazardous material due to the toxicity and many contamination cases were surveyed in some developed countries. U.S.EPA(Kram et al., 2001) suggested DNAPL characterization methods and approaches based on survey experiences at several sites. However, Korea has not the least assessment of contamination and trial of remediation, although there are a lot of doubtable areas where ground water would be contaminated with TCE. In this study, we try to assess the volume and extent of ground water contamination with TCE and delineate the contamination source zones in an industrial area. Ground water in this area flows through fractures and the contaminant TCE has the properties of high volatility, high density and low partitioning to soil material. Thus, we applied a variety of technical approaches to identify the contamination status; documentary, hydrogeochemical, hydrogeological and geological surveys. In addition, additional survey was performed based on the interim findings, which showed that ground water contamination was limited to the relatively small area with high concentrations to the deep place. The contamination source zone is estimated to be the asphalt test institute where a great deal of TCE has been used to analyze the amount of asphalt soluble in TCE since 1984. Based on the contamination characterization and a myriad of documents about ground water remediation, appropriate site remediation management options will be recommended later. This study is now under way and this paper was focused on describing the technical approaches used to achieve the goals of this study.

  • PDF

홍콩 친환경 재생공간의 친환경성 분석 (An Environment-friendly Analysis of Hong-kong Environment-friendly Reuse Space)

  • 김사라;남경숙
    • 한국실내디자인학회논문집
    • /
    • 제21권3호
    • /
    • pp.194-202
    • /
    • 2012
  • The purpose of this study is to extract environment-friendly planning elements to apply in Korea by putting together and reclassifying four foreign environment-friendly certification systems related to regeneration spaces - LEED in USA, CASBEE in Japan, BREEAM in England and BEAM in Hong Kong - and analyze and evaluate domestic and foreign spaces which were certified as Environment-friendly spaces in order to offer plan guidelines to raise awareness of the importance of environment-friendly elements in regeneration spaces and to encourage them. The concept and the characteristics of green building were studied through documentary survey. In addition, green certification system of the present domestic new spaces and foreign regeneration spaces was studied and assessment tools for indoor regenerated spaces-related green certification system were developed. With checklists which are developed in this study, level of going green of foreign spaces certified environment-friendly was assessed. Based on the results of this study, conclusions are as follows. As a result of case research of spaces-certified green of Hong-Kong's existing buildings with a developed checklist, application of general assessment part was all alike, but that of detailed assessment part was different. However, Hong Kong showed superiority in lighting energy saving, separate collection of recyclable domestic waste, recycling by-product and management. In addition, Hong Kong applied eco-friendly planning elements maintaining buildings in their condition as possible as it could with management, use of green program, replacement with high efficiency lighting, monitoring system, installation of recycling bins and energy saving by attaching reflective film.

  • PDF