• Title/Summary/Keyword: distribution of particles

Search Result 1,799, Processing Time 0.03 seconds

A Study on the Coarse Particles Burden to Aerosol in Seoul Area (粗大粒子가 大氣淨遊粉塵에 주는 負荷)

  • 이윤재;김희강
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.1 no.1
    • /
    • pp.71-82
    • /
    • 1985
  • The effect on the particulate matters in the atmosphere was investigated in Seoul area from March, 1984 to Aprill, 1985. Aerosols were collected by filters on nine stages Andrsen Air Sampler, and size distribution and total concentration of the aerosols, Fe and Pb were measured. In spring with Yellow Sand the concentration of particles in aerosols was 185.55$\mug/m^3$ and CP/TA was 65.9%. But in spring without Yellow Sand those of particles was 135.45$\mug/m^3$ and CP/TA was 58.6%. Accordingly the concentration of coarse particles with Yellow Sand was higher than without them in Spring. Above results indicate that in Seoul Area the main source of air pollution originated from natural burdens, especially from soil. The concentration of Pb was similarly valued through both seasons in Seoul area but fine particles valued above coarse particles. On the other hand, in urban area, the natural and anthropogenic sources have influenced on the concentration of Pb. With referred to particle size distribution for Fe, the concentration of coarse particles was 0.168$\etag/m^3$ (CP/TA: 74.3%) in Spring with Yellow Sand, 0.096$\mug/m^3$ (CP/TA: 71.6%) without Yellow Sand and 0.083$\mug/m^3$ (CP/TA: 67.4%) in winter, respectively. Compared with fine particles, all of them were higher. It indicated that the origin of coarse particles in urban air was not related to anthropogenic source. The concentration of Fe was influenced by Yellow Sand and contributed to air pollution.

  • PDF

Elemental components analysis according to the size of fine particles emitted from a coal-fired power plant using an ejector-porous tube dilution sampling and ELPI (이젝터-다공튜브 희석 샘플링과 ELPI를 이용한 석탄화력발전소 배출 미세먼지의 입자 크기에 따른 성분 분석)

  • Shin, Dongho;Park, Daehoon;Joe, Yunhui;Kim, Younghun;Hong, Kee-Jung;Lee, Gunhee;Han, Bangwoo;Hwang, Jungho
    • Particle and aerosol research
    • /
    • v.18 no.3
    • /
    • pp.69-77
    • /
    • 2022
  • In order to understand the characteristics of fine particles emitted from coal-fired power plant stacks, it is important to analyze the size distribution and components of particles. In this study, particle size distributions were measured using the ejector-porous tube dilution device and an ELPI system at a stack in a coal-fired power plant. Main elemental components of particles in each size interval were also identified through TEM-EDS analysis for the particles collected in each ELPI stage. Particle size distributions based on number and mass were analyzed with component distributions from 0.006 to 10 ㎛. The highest number concentration was about 0.01 ㎛. The main component of the particles consisted of sulfur, which indicated that sulfate aerosols were generated by gas-to-particle conversion of SO2. In a mass size distribution, a mono-modal distribution with a mode diameter of about 2 ㎛ was shown. For the components of PM1.0 (particles less than 1 ㎛), the abundance order was F > Mg > S > Ca, and however, for the components of PM10 (particles less than 10 ㎛), it was in the order of Fe > S > Ca > Mg. The elemental components by particle size were confirmed.

Quantitative characteristics of particle size distribution by the wear mode transition (마모유형 천이에 따른 입자크기분포의 정량적 특성)

  • 공호성;권오관
    • Tribology and Lubricants
    • /
    • v.2 no.1
    • /
    • pp.39-45
    • /
    • 1986
  • Wear simulation test have been conducted in mild, severe and transient wear regions by a four-ball wear tester. Wear particles are separatively deposited by the RPD technique, and quantitatively analysed in terms of wear particles size distribution. Characteristics of the wear particle size distribution are compare to the results of wear tests through both weibull parameters and center moment method of the weibull distribution function.

Meauring Method of Magnetic Particles' Coercivity Distribution and Its Applications (자성분말의 보자력 분포도 측정방법과 그 응용)

  • 홍양기;박상준;정홍식
    • Journal of the Korean Magnetics Society
    • /
    • v.5 no.3
    • /
    • pp.216-221
    • /
    • 1995
  • Both manufacturing parameters and particles' chemical composition controll coercivity and its distribution of magnetic particles. The coercivity and its distribution are important properties for high density magnetic recording, so these are used as tool for evaluation of reproducibility of magnetic particles. We report in this paper the applications of dM/dH versus H curve, which is derived from magnetic hysteresis loop, to the evaluation of coercivity distribution of magnetic particles and oxidation studies of recording metal particles. The coercivity distri-bution can be estimated from the full width half rnaximun (FWHM) and the peak shape of the dM/dH versus H curve. The peak shape of the curve depends upon distribution of particles' coercivity. The peak of dM/dH versus H curve becomes broad and lor is splitted into two or rmre peaks. It depends on uniformity of particles' coercivity. When the coercivity difference between Ba-Ferrite and ${\gamma}-Fe_{2}O_{3}$ is larger than 600 Oe, the peak becomes broad and is consequently splitted into two peaks. Ununiformly substituted Ba-Ferrite particles show broad peak. It is apparent that the analysis of the curve is one of sensitive measuring techniques for determination of coercivity distri-bution and studies on magnetic properties of substituted Ba-Ferrite and oxidation of magnetic recording metal particles.

  • PDF

Analysis of Electrical Coagulation of Unipolar Charged Particles in an Alternating Electric Using Moment Method (모멘트법을 이용한 AC 전기장 내의 단극성 입자의 전기응집 해석)

  • Ji, Jun-Ho;Hwang, Jeong-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.1
    • /
    • pp.9-17
    • /
    • 2001
  • A numerical study has been carried out on the evolution of the particle size distribution for unipolar charged particles that experience coagulation in an alternating electric field. The collision frequency function of charged particles was analytically derived. The log-normal size distribution function is utilized for representing a poly-disperse size distribution and the moments of the particle size distribution are used to solve the general dynamic equation considering only AC electric force effect. The results are compared with the effects of brownian coagulation.

Particle Detachment in Granular Media Filtration (입상여과에서 입자물질의 탈리)

  • Kim, Jinkeun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.5
    • /
    • pp.673-679
    • /
    • 2004
  • Particle breakthrough can occur by either the breakoff of previously captured particles (or flocs) or the direct passage of some influent particles through the filter. Filtration experiments were performed in a laboratory-scale filter using spherical glass beads with a diameter of 0.55 mm as collectors. A single type of particle suspension (Min-U-Sil 5, nearly pure $SiO_2$) and three different destabilization methods (pH control, alum and polymer destabilization) were utilized. The operating conditions were similar to those of standard media filtration practice: a filtration velocity of 5 m/h. To assess the possibility of particle detachment during the normal filtration, a hydraulic shock load (20% increase of flow rate) was applied after 4 hours of normal filtration. The magnitude of particle detachment was proportional to the particle size for non-Brownian particles. At the same time, less favorable particles, i.e., particles with larger surface charge, were easily detached during the hydraulic shock load. Therefore, proper particle destabilization before filtration is crucial for maximum particle removal as well as minimum particle breakthrough.

Analysis of Shape Distribution Characteristics of Wear Particles using Histogram (도수분포를 이용한 마멸입자의 형태 분포특성의 분석)

  • Park, Heung-Sik;Woo, Kyu-Sung;Cho, Yon-Sang;Jun, Sung-Jae
    • Tribology and Lubricants
    • /
    • v.23 no.1
    • /
    • pp.29-36
    • /
    • 2007
  • It necessarily follows that wear particles are generated through a friction and wear in a mechanical moving system. The wear particles are relative to the failure and the life of machine elements directly. To analyze the wear particle, its shape characteristics were calculated quantitative values such as diameter, roundness and fractal parameters by digital image processing. In this study, the histograms of shape parameters of wear particles were used for the purpose of analyzing the distribution of wear particles in various conditions. We consider that the histogram of shape parameter can be effectively represented to study a wear mechanism.

Distribution Characteristics of Wear Particles from Material of Machine Elements in Lubricant condition (윤활조건에 따른 기계부품용 소재에서 발생된 마멸입자의 분포 특성)

  • Cho, Yon-Sang;Jun, Sung-Jae;Kim, Young-Hee;Park, Heung-Sik
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1607-1612
    • /
    • 2007
  • It necessarily follows that wear particles are generated through a friction and wear in a mechanical moving system. The wear particles are relative to the failure and the life of machine elements directly. To analyze the wear particle, its shape characteristics were calculated quantitative values such as diameter, roundness and fractal parameters by digital image processing. In this study, the histograms of shape parameters of wear particles were used for the purpose of analyzing the distribution of wear particles in various conditions. We consider that the histogram of shape parameter can be effectively represented to study a wear mechanism.

  • PDF

Magnetization of Ultrafine Cadmium Ferrite Particles

  • Park, Eun-Jung
    • Journal of the Korean Ceramic Society
    • /
    • v.39 no.1
    • /
    • pp.12-15
    • /
    • 2002
  • Ultrafine cadmium ferrite particles have been investigated by X-ray diffractometry, transmission electron microscopy and SQUID magnetometry. All peaks of X-ray diffraction patterns are broad, but correspond to a cubic spinel structure with the lattice constant of 8.65 $\AA$. The average particle size determined by TEM is 9.7 nm and the size distribution of particles is not normal, but lognormal. The maximal magnetization measured at 5 K was 17.7 emu/g. The experimental data show a transi-tion from a disorder ferrimagnetic phase to a spin-glass phase (i.e. reentrant behavior) with a freezing temperature (T$\_$f/) of 30 K. Superparamagnetic behavior of the particles is confirmed by the coincidence of the plots of M vs. H/T for 100 and 300 K.

Particle Attachment in Granular Media Filtration (입상여과에서 입자물질의 부착)

  • Kim, Jinkeun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.5
    • /
    • pp.666-672
    • /
    • 2004
  • Granular media filtration is used almost universally as the last particle removal process in conventional water treatment plants. Therefore, superb particle removal efficiency is needed during this process to ensure a high quality of drinking water. However, every particle can not be removed during granular media filtration. Besides the pattern of particle attachment is different depending on physicochemical aspects of particles and suspension. Filtration experiments were performed in a laboratory-scale filter using spherical glass beads with a diameter of 0.55 mm as collectors. A single type of particle suspension (Min-U-Sil 5) and pH control was used to destabilize particles. The operating conditions were similar to those of standard media filtration practice: a filtration velocity of 5 m/h. More favorable particles, i.e., particles with smaller surface charge, were well attached to the collectors especially during the early stage of filtration. This selective attachment of the lower charged particles caused the zeta potential distribution (ZPD) of the effluent to move to a more negative range. On the other hand, the ZPD of the effluent did not keep moving from less negative to more negative during the later stages of filtration, and this result was thought to be caused by two reasons: ripening effects and the detachment of flocs.