• Title/Summary/Keyword: distribution feeder

Search Result 224, Processing Time 0.029 seconds

The Optimized Standards and Criteria for Installing Switches on Distribution Feeder (국내 배편계통의 최적 개폐기 설치 기준)

  • Jo, Nam-Hun;Ha, Bok-Nam;Lee, Heung-Ho
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.5
    • /
    • pp.238-246
    • /
    • 2002
  • Utilities are trying to install the equipment of high quality to avoid deterioration of supply reliability. In addition, many sectionalizing switches which can decrease the total outage value for a fault are installed for the same reason. Therefore, utilities are interested in stun dards and criteria for installing switches to optimize the total cost on distribution systems. The affect of sectionalizing switches installed on distribution feeder is gradually decreased because the failure rate on distribution feeder is decreased. Also the automation for distribution systems is widely applied for the efficient operation. Therefore, the renewal for installation standards of sectionalizing switches Is required to reflect the current operation situation. The variable data is used to consider the KEPCO's real situation of distribution feeder as follows; the feeder capacity, connecting rate, feeder length, failure rate of distribution feeder, the failure rate of switches, perception time of feeder fault, the restoration time for a faulted section, the transfer time to other feeders, and the switching time. In this study, We propose equations which can determine the number of sectionalizing switches for minimizing the outage and switch installation cost.

The optimized standards and criteria for installing switches on distribution feeder (국내 배전계통의 최적 개폐기 설치 기준(I))

  • Cho, Nam-Hun;O, Jae-Hyeong;Lee, Heung-Ho;Ha, Bok-Nam
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.70-73
    • /
    • 2002
  • Utilities are trying to install the equipment of high quality to avoid deterioration of supply reliability. In addition, many sectionalizing switches which can decrease the total outage value for a fault are installed for the same reason. Therefore, utilities are interested in standards and criteria for installing switches to optimize the total cost on distribution systems. The affect of sectionalizing switches installed on distribution feeder is gradually decreased because the failure rate on distribution feeder is decreased. Also the automation for distribution systems is widely applied for the efficient operation. Therefore, the renewal for installation standards of sectionalizing switches is required to reflect the current operation situation. The variable data is used to consider the KEPCO's real situation of distribution feeder as follows; the feeder capacity, connecting rate, feeder length, failure rate of distribution feeder, the failure rate of switches, perception time of feeder fault, the restoration time for a faulted section, the transfer time to other feeders, and the switching time. In this study, We propose equations which can determine the number of sectionalizing switches for minimizing the outage and switch installation cost.

  • PDF

Identification of the faulted Feeder it Distribution Networks with Distributed Generations (분산전원이 연계된 배전 계통의 고장 선로 구분)

  • Kim S. G.;Kim K. H.;Jang S. I.;Kang Y. C.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.257-259
    • /
    • 2004
  • This paper proposes the identification method for the faulted feeder, where it identify whether the faulted feeder is the DG-connected feeder or the neighboring feeder (but sharing the same bus of the substation). In general, DG has to be disconnected from the grid when the fault occurs on the interconnected distribution feeder as soon as possible. However, the faults occured on the neghboring feeder would mistakenly cause the disconnection of the DG. For reliable operation of DG, DG should be sustained at the fault occurred on neighboring distribution feeders. The proposed identification method utilizes the impedance monitored from the DG and examines the coordination of overcurrent relay of the distribution system. This paper describes how the proposed method to identify the faulted feeder and how the method can be utilized.

  • PDF

Reliability analysis of the switch installation in the main feeder and in the radial/loop lateral feeders in distribution system (간선 및 분기선의 개폐기 설치 효과 분석(I))

  • Cho, Nam-Hun;O, Jae-Hyeong;Lee, Heung-Ho;Ha, Bok-Nam
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.79-82
    • /
    • 2002
  • The addition of switches to a distribution feeder does, in general, increase reliability by decreasing the duration of the outage of many to the customers on the feeder. To cover its service area so that feeder-level delivery reaches sufficiently close to all customers, feeders typically split their routes many times, in what is often called a lateral feeder. It is interesting to note, however, that the effectiveness of a switch is very much dependent on the types of lateral feeder. The types of lateral are classified into two types. The first is loop lateral feeder that can connect its load to an adjacent feeder through a tie line in case that a fault occurs in its feeder and it is laid out so that every feeder has complete fault backup through re-switching of its loads to other sources like a main feeder. The second is the radial lateral feeder cannot connect its load to an adjacent line, no provision is made for contingency backup of feeders. There are no other circuits in the radial lateral feeder form which to restore power. In this study, we evaluate the effectiveness of a switch installation between on the radial and loop lateral feeders to increase reliability by decreasing the duration of the outage. These results can help power utility to design the switch layouts on the radial and loop lateral feeder system.

  • PDF

The feeder automation using the switches with multi functions (다기능개폐기를 이용한 선로운전자동화)

  • Song, Byong-Kwon;Hong, Soon-Hak;Ha, Bok-Nam
    • Proceedings of the KIEE Conference
    • /
    • 1992.07a
    • /
    • pp.183-186
    • /
    • 1992
  • The distribution automation functions include feeder automation, data acquisition and processing, remote meter reading and load management. This report explains the function of feeder automation and the accomplishment method of feeder automation using the switches of distribution system with multi functions.

  • PDF

Distribution Network Reconfiguration Using Feeder Modeling (피더모델링을 이용한 배전계통 재구성)

  • Kim, Se-Ho;An, Jin-Oh;Lee, Soo-Mook
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.1156-1158
    • /
    • 1998
  • This paper Presents two distribution-feeder models to simplify complicated distribution system calculations. These equivalent models are developed to simulate the total series voltage drop at the end of the given feeder and the total line loss of the given feeder accurately. In addition, the proposed models are bidirectional. This means that power infeed can be at either end and the model is accurate. Also, it is shown that the proposed models are suitable for network reconfiguration.

  • PDF

The Optimal Distribution Feeder Reconfiguration Using Knowledge Base (지식베이스를 이용한 배전계통의 최적재구성)

  • Cho, S.H.;Choi, B.Y.;Kim, S.H.;Lee, J.K.
    • Proceedings of the KIEE Conference
    • /
    • 1993.07a
    • /
    • pp.99-101
    • /
    • 1993
  • This paper presents an approach to feeder reconfiguration in order to achieve an efficient operation of distribution systems utilizing knowledge base. The optimal feeder reconfiguration in this study eliminates various abnormal states which will create feeder overloads and feeder constraint problems. and will also accomplish minimum power loss of the distribution systems under normal operating condition by means of branch exchanges to change the status of sectionalizing switches with experiences of the experts. For an effective implementation of feeder reconfiguration, a best-first tree searching strategy based on heuristics is employed to evaluate the various alternatives of load transfer. The heuristic exchange of branches results in reduction of the search space as a means of implementing the best-first searching strategy.

  • PDF

Power Flow Control of a Multi-bus/Three-feeder Distribution System Using Generalized Unified Power Quality Conditioner

  • Mohammed, B.S.;Ibrahim, R.;Perumal, N.;Rao, K.S. Rama
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.8-17
    • /
    • 2015
  • This paper analyses the power flow of a three-feeder/multi-bus distribution system by a custom Generalized Power Quality Conditioner (GUPQC). The GUPQC has been realized by three voltage source converters (VSCs) coupled back-to-back through a common DC-link capacitor on the DC-side. One feeder was controlled by the shunt compensator, whereas each of the other two feeders was controlled by the proposed novel series compensator. The GUPQC has the capability to simultaneously compensate voltage and current quality problems of a multi-bus/three-feeder distribution system. Besides that, the power can be transferred from one feeder to other feeders to compensate for poor power quality problems. Extensive simulation studies were carried out by using MATLAB/SIMULINK software to establish the ability of the GUPQC to improve power quality of the distribution systems under distorted supply voltage conditions.

Distribution Feeder Reconfiguration Using Heuristic Rules (경험적 규칙을 이용한 배전계통의 재구성기법)

  • Cho, Si-Hyung;Choi, Byoung-Youn;Woo, Kwang-Bang
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.363-365
    • /
    • 1991
  • This paper presents a method for feeder reconfiguration in order to operate distribution systems efficiently using heuristic rules. The reconfiguration method presented here not only eliminates various abnormal states but also achieves minimum power loss and optimum load balance of the distribution feeders under normal operating condition transfering loads from one feeder to anoter applying the experiences of the experts. To implement the method effectively, a best-first tree searching strategy based on heuristics is used to evaluate the various load transfer alternatives. The development of a rule-based system aimed at the reduction of the search space is presented as a means of implementing the best-first searching strategy. The results of the computer simulation of the above procedure are as follows; 1) achieving minimum power loss of the distribution feeder adopting the optimum load transfer alternative. 2) Enhencing system reliability and achieving load balance through rational allocation of the feeder loads.

  • PDF

An feeder Automation System Using Active Database (능동 데이터베이스 이용한 배전선로 운전자동화)

  • 최상열
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.5
    • /
    • pp.94-102
    • /
    • 2003
  • This paper presents active management of feeder automation systems using active database. DAS(Distribution Automation System) has been managed for feeder automation in passive manner. Therefore, feeder automation system has to be managed by operator when feeder overloadings is detected. It may be possible for propagating the feeder overloadings area by operator's mistake. To overcome this defect, the author proposed the feeder automation technique with active manner to obtain feasible feeder reconfiguration. Active database can manage feeder automation system by data driven monitoring of events and by corresponding actions without operator's intervening. To manage feeder automation system with active manner, production rule, active rule manager are designed. And active database system architecture for feeder automation system is proposed. Test results on the KEPCO's 108 bus distribution system show that the performance is efficient and robust.