• 제목/요약/키워드: distortion grid

검색결과 184건 처리시간 0.028초

고조파 전압이 포함된 계통과 연계된 듀얼벅 인버터의 DCM 구간에서 전류 왜곡 개선을 위한 비례공진 제어기 (The Proportional Resonant Controller for Improving the Current Distortion of the Dual buck inverter in DCM Section Connected grid system with harmonic voltage)

  • 최민재;조영훈;최진욱;문영민
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2018년도 전력전자학술대회
    • /
    • pp.286-287
    • /
    • 2018
  • Recently, the development of renewable energy using solar energy is drawing attention. One of these PV systems, the Dual buck Inverter, is one of the topologies used in conjunction with the system, characterized by high efficiency and shoot-through reduction. However, current distortion appears severely in grid connection. So, in this paper, the method of compensation through PR controller was verified through simulation as an analysis of current distortion components and a control method to improve them.

  • PDF

계통연계형 태양광발전시스템의 PSCAD/EMTDC 모델링 및 전력품질 평가 (Power Quality Assessment and PSCAD/EMTDC Modeling of Grid-Connected PV System)

  • 설재웅;장재정;김진오
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 D
    • /
    • pp.2193-2194
    • /
    • 2006
  • This paper presents the results of a grid-connected photovoltaic (PV) system modeling that contain incremental conductance MPPT(Maximum Power Point Tracking) controller by PSCAD/EMTDC simulator and investigates the influence that can occur in the grid-connected PV system from aspect of power quality, i.e. voltage drop, total harmonic distortion(THD) and total demand distortion(TDD). The measured data the PV array modeling of PSCAD/EMTDC in Cheongwadae, Seoul, Korea is used in the paper.

  • PDF

계통연계형 태양광발전시스템의 PSCAD/EMTDC 모델링 및 전력품질 평가 (Power Quality Assessment and PSCAD/EMTDC Modeling of Grid-Connected PV System)

  • 설재웅;장재정;김진오
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.561-562
    • /
    • 2006
  • This paper presents the results of a grid-connected photovoltaic(PV) system modeling that contain incremental conductance MPPT(Maximum Power Point Tracking) controller by PSCAD/EMTDC simulator and investigates the influence that can occur in the grid-connected PV system from aspect of power Quality, i.e. voltage drop, total harmonic distortion(THD) and total demand distortion(TDD) The measured data the PV array modeling of PSCAD/EMTDC in Cheongwadae, Seoul, Korea is used in the paper.

  • PDF

계통연계형 태양광발전시스템의 PSCAD/EMTDC 모델링 및 전력품질 평가 (Power Quality Assessment and PSCAD/EMTDC Modeling of Grid-Connected PV System)

  • 설재웅;장재정;김진오
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.1227-1228
    • /
    • 2006
  • This paper presents the results of a grid-connected photovoltaic(PV) system modeling that contain incremental conductance MPPT(Maximum Power Point Tracking) controller by PSCAD/EMTDC simulator and investigates the influence that can occur in the grid-connected PV system from aspect of power quality, i.e. voltage drop, total harmonic distortion(THD) and total demand distortion(TDD). The measured data the PV array modeling of PSCAD/EMTDC in Cheongwadae, Seoul, Korea is used in the paper.

  • PDF

PSO를 이용한 계통연계형 인버터 전류제어기의 자동조정에 관한 연구 (A Study on Tuning of Current Controller for Grid-connected Inverter Using Particle Swarm Optimization)

  • 안종보;김원곤;황기현;박준호
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제53권11호
    • /
    • pp.671-679
    • /
    • 2004
  • This paper presents the on-line current controller tuning method of grid-connected inverter using PSO(particle swarm optimization) technique for minimizing the harmonic current. Synchronous frame PI current regulator is commonly used in most distributed generation. However, due to the source voltage distortion, specially in weak AC power system, current may contain large harmonic components, which increase THD(total harmonic distortion) and deteriorates power quality. Therefore, some tuning method is necessary to improve response of current controller. This paper used the PSO technique to tune the current regulator and through simulation and experiments, usefulness of the tuning method has been verified. Especially in simulating the tuning process, ASM(average switching model) of inverter is used to shorten execution time.

계통연계형 태양광발전시스템의 PSCAD/EMTDC 모델링 및 전력품질 평가 (Power Quality Assessment and PSCAD/EMTDC Modeling of Grid-Connected PV System)

  • 설재웅;장재정;김진오
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 C
    • /
    • pp.1687-1688
    • /
    • 2006
  • This paper presents the results of a grid-connected photovoltaic (PV) system modeling that contain incremental conductance MPPT(Maximum Power Point Tracking) controller by PSCAD/EMTDC simulator and investigates the influence that tan occur in the grid-connected PV system from aspect of power quality, i.e. voltage drop, total harmonic distortion(THD) and total demand distortion(TDD). The measured data the PV array modeling of PSCAD/EMTDC in Cheongwadae, Seoul, Korea is used in the paper.

  • PDF

High-Reliability Three-Phase Dual-Buck Grid-Connected Inverter without Shoot-Through Problem

  • Fu, Zhenbin;Feng, Zhihua;Chen, Xi;Zheng, Xinxin
    • Journal of Power Electronics
    • /
    • 제19권2호
    • /
    • pp.454-462
    • /
    • 2019
  • When compared to traditional bridge-type inverters, the dual-buck inverter has a higher reliability due to the fact that its bridge legs do not have a shoot-through problem. In this paper, the working principle of the dual-buck inverter is analyzed. A comparison of the working modes under full-cycle and half-cycle control is discussed. With half-cycle control, the inverter can realize a higher efficiency. However, this results in current zero-crossing distortion. The corresponding control strategy of the dual-buck inverter is proposed in order to realize both high efficiency and low current harmonic distortion. In addition, the system stability is analyzed. Dead-time is unnecessary due to the advantages of the topology. Thus, the current harmonic distortion can be further reduced. An inverter with the proposed control strategy has the advantages of high reliability, high efficiency and low current harmonic distortion. Finally, simulation and experimental results are given to verify the theoretical analysis.

특이값 분해를 이용한 치수측정 기반 디지털 트윈 알고리즘 경량화 (Lightweight Algorithm for Digital Twin based on Diameter Measurement using Singular-Value-Decomposition)

  • 이승민;박대진
    • 대한임베디드공학회논문지
    • /
    • 제18권3호
    • /
    • pp.117-124
    • /
    • 2023
  • In the machine vision inspection equipment, diameter measurement is important process in inspection of cylindrical object. However, machine vision inspection equipment requires complex algorithm processing such as camera distortion correction and perspective distortion correction, and the increase in processing time and cost required for precise diameter measurement. In this paper, we proposed the algorithm for diameter measurement of cylindrical object using the laser displacement sensor. In order to fit circle for given four input outer points, grid search algorithms using root-mean-square error and mean-absolute error are applied and compared. To solve the limitations of the grid search algorithm, we finally apply the singular-value-decomposition based circle fitting algorithm. In order to compare the performance of the algorithms, we generated the pseudo data of the outer points of the cylindrical object and applied each algorithm. As a result of the experiment, the grid search using root-mean-square error confirmed stable measurement results, but it was confirmed that real-time processing was difficult as the execution time was 10.8059 second. The execution time of mean-absolute error algorithm was greatly improved as 0.3639 second, but there was no weight according to the distance, so the result of algorithm is abnormal. On the other hand, the singular-value-decomposition method was not affected by the grid and could not only obtain precise detection results, but also confirmed a very good execution time of 0.6 millisecond.

계통연계형 인버터의 왜곡된 계통전압에 의해 발생하는 전류고조파 저감방법 (Reduction Method of Harmonic Current by Distorted Grid Voltage in the Grid-connected Inverter)

  • 목형수;최규하;이정민;김상훈;지준근
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 추계학술대회 논문집
    • /
    • pp.108-111
    • /
    • 2007
  • Phase angle in grid-connected inverter is important information for current control. When different loads are connected to PCC(Point of Common Coupling) of grid, distorted grid voltage is taken place by load utility generating distorted current. Especially, in case the grid voltage is distorted by low order frequency such as $3^{rd}$, $5^{th}$ harmonic, phase angle of PLL output is distorted. This paper analyze problem of current THD(Total Harmonic Distortion) due to distorted phase angle by distorted grid voltage, and propose control method compensating this problem. Also, it‘s validity is verified by simulation and experiment.

  • PDF

Performance Improvement of Grid-Connected Inverter Systems under Unbalanced and Distorted Grid Voltage by Using a PR Controller

  • Lee, Jong-Hyun;Jeong, Hae-Gwang;Lee, Kyo-Beum
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권6호
    • /
    • pp.918-925
    • /
    • 2012
  • This paper proposes a control method for grid-connected inverter systems under unbalanced and distorted grid voltage. The proposed method can reduce the power ripple caused by the unbalanced condition and compensate for the low-order harmonics of the output currents caused by the distortion of grid voltage. To reduce the power ripple, our method replaces the two conventional PI controllers with one PR controllers in the stationary frame. PR controllers can implement selective harmonic compensation without excessive computational requirements; the use of these controllers simplifies the method. Both the simulated and experimental results agree well with the theoretical analysis.