• 제목/요약/키워드: distorted leg

검색결과 7건 처리시간 0.022초

2-leg 3상 PWM 인버터의 출력전압에서 직류링크 리플 전압의 영향 보상 (Compensation of Effects of DC-Link Ripple Voltages on Output Voltage of Two-leg Three-Phase PWM Inverters)

  • 김영신;이동춘;석줄기
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.572-574
    • /
    • 2005
  • In this paper, a compensation scheme for the effect of dc-link ripple voltages on output voltage of two-leg and three-phase PWM inverters is proposed, without which compensation scheme the three-phase output voltage and current are much distorted. The proposed scheme has been verified by experimental results.

  • PDF

다리관절, 다리-팔 이음뼈, 허리뼈의 불균형을 가진 휜다리에 대한 전신조정술 관절중재모형의 교정효과 (Effects of the General Coordinative Manipulation Joint Intervention Model in Correcting Distort Leg with Imbalance of the Lower Extremity Joint, Pelvic and Shoulder Girdles, and Lumbar Spine)

  • 문상은
    • 대한통합의학회지
    • /
    • 제8권3호
    • /
    • pp.1-10
    • /
    • 2020
  • Purpose : The purpose of this study is to analyze the corrective effect of the general coordinative manipulation (GCM) joint intervention model on distort leg with imbalance of the lower extremity joints, pelvic and shoulder girdles, and lumbar spine. Methods : The study used a comparative analysis of the size of the distort leg and the imbalance of the lower extremity joints, pelvic and shoulder girdles, and lumbar spine before and after the application of the GCM joint intervention model. A total of 31 subjects from movement center G and the department of physical therapy at university M were selected as research subjects, and they were divided into two groups. The GCM joint intervention model was applied to 18 subjects in the bow knee group and 13 subjects in the knock knee group. The two groups received daily intervention three times a week for four weeks. The corrective effect of the GCM joint intervention model for each type of distort leg was compared and analyzed. Results : The effects of the GCM joint intervention model in correcting bow knee and knock knee with knee deformation and imbalance of the lower extremity joints, pelvic and shoulder girdles, and lumbar spine were significant in most domains (p<.05). The correlation between the bow knee and knock knee groups showed significance in most domains (p<.05). Conclusion : The GCM joint intervention model showed significant corrective effect in the bow knee and knock knee groups in terms of knee deformation, lower extremity joints, pelvic and shoulder girdles, and lumbar spine (p<.05).

Control Strategy for Selective Compensation of Power Quality Problems through Three-Phase Four-Wire UPQC

  • Pal, Yash;Swarup, A.;Singh, Bhim
    • Journal of Power Electronics
    • /
    • 제11권4호
    • /
    • pp.576-582
    • /
    • 2011
  • This paper presents a novel control strategy for selective compensation of power quality (PQ) problems, depending upon the limited rating of voltage source inverters (VSIs), through a unified power quality conditioner (UPQC) in a three-phase four-wire distribution system. The UPQC is realized by the integration of series and shunt active power filters (APFs) sharing a common dc bus capacitor. The shunt APF is realized using a three-phase, four-leg voltage source inverter (VSI), while a three-leg VSI is employed for the series APF of the three-phase four-wire UPQC. The proposed control scheme for the shunt APF, decomposes the load current into harmonic components generated by consumer and distorted utility. In addition to this, the positive and negative sequence fundamental frequency active components, the reactive components and harmonic components of load currents are decomposed in synchronous reference frame (SRF). The control scheme of the shunt APF performs with priority based schemes, which respects the limited rating of the VSI. For voltage harmonic mitigation, a control scheme based on SRF theory is employed for the series APF of the UPQC. The performance of the proposed control scheme of the UPQC is validated through simulations using MATLAB software with its Simulink and Power System Block set toolboxes.

인버터의 비선형 특성이 유도전동기의 자속 추정에 미치는 영향에 대한 연구 (A study on the effect of inverter nonlinear characteristic on the flux estimation of an induction motor)

  • 김상훈;김태석
    • 산업기술연구
    • /
    • 제28권B호
    • /
    • pp.167-174
    • /
    • 2008
  • In this paper, the analysis on type effect of inverter output voltage distortion on the control of an induction motor is discussed. The inverter output voltage is distorted differently from the reference voltage owing to the inverter nonlinear characteristic. The inverter nonlinear characteristic results from the voltage drop, the inherent characteristic of the power semiconductor, and the dead time for preventing the short circuit of the inverter leg. This characteristic distorts the inverter output voltage and then, causes the motor flux estimation error. Although this characteristics do not significantly effect in the general-purpose induction motor control, but significantly effect on the low-speed operation of high performance motor control such as the sensorless vector control.

  • PDF

Design and Implementation of an Automatic Design Edit System by Lisp Language

  • Park, Hong-Seok;Lee, Chun-Keun;Yeo, Jeong-Mo
    • 한국멀티미디어학회논문지
    • /
    • 제6권4호
    • /
    • pp.714-722
    • /
    • 2003
  • Men's clothing has been recently giving higher market shares to the ready-made clothes rather than the custom-tailored clothes. With many active studies on the human body and design, the ready-made clothes win popularity due to their rapid repairing, various design, and cheap prices, though they are not perfect suitable for some people. Therefore the ready-made has a weak point unable to consider all of the individual physical characteristics. However the custom-tailored clothes ate able to make clothing perfectly suitable lot their customers, though they require longer time-taking and expensive costs. In this context, this paper is design and implementation an automatic design edit system to provide a rapid and cheap service for customers on the ground of the custom-tailored clothes. In other words, this paper intended to use computer systems lot rapidly and precisely providing design dependent on the individual physical characteristics including a distorted bodies, types of the leg, and a height of the shoulder. To do so, the paper using not only studies on the human body and the custom-tailored clothes but also technical know-hows planned design for each individual body by LISP language and automatically process the design through CAD system. Consequently, the rapid and precise processing has reduced inventories and production costs, leading to supplying high quality clothes at lower prices.

  • PDF

인체에서 기혈(氣穴) 순환 회복을 위한 기혈테라피의 효과 탐색 (Exploring the Effect of Qihyul-therapy for Recovery of Qi Circulation in Body)

  • 김용필;이형환
    • 한국자연치유학회지
    • /
    • 제8권2호
    • /
    • pp.63-70
    • /
    • 2019
  • 목적: 본 연구의 목적은 둔부근육의 협착, 틀어진 체형, 어깨 통증이 있는 기혈순환이 나쁜 대상자들을 상대로 기혈테라피의 효과를 탐색하는 것이었다. 방법: 기혈테라피와 교정 기혈운동을 사용 하였다. 결과: 기혈테라피를 시술하기 전에 둔부 근육이 거의 움직이지 않았지만, 시술한 후에는 근육의 탄력이 회복되었고 회색으로 경화되었든 피부의 색상도 밝아지었고 항문 괄약근에도 힘이 생기었다. 대상자의 체형이 우측으로 -7°가량 틀어지면서 우측 팔이 좌측팔에 비해서 약 6 cm정도 길었었으나, 체형교정 후에는 우측 팔의 길이가 약 5 cm 정도 줄어들었고, 틀어졌던 체형이 거의 평형을 이루었다. 목 및 어깨교정 후에는 쇄골과 목의 간격이 7 cm로 간격이 넓어졌고, 승모근을 풀어준 후에는 10 cm로 넓어졌으며, 어깨통증이 많이 완화 되었다. 골반교정 후 둔부통증이 완화되었고, 고관절의 위치가 바르게 돌아왔다. 좌측으로 45°각도 틀어졌던 우측다리가 바르게 교정이 되었으며, 4 cm 정도 길었던 우측 다리의 길이도 좌우가 같아졌다. 둔부통증 및 무릎통증도 완화되었다. 골반교정 기혈운동 후에 대상자 1의 고관절의 위치가 바로 잡히어 좌측으로 45°각도 틀어졌던 우측다리가 바르게 교정이 되었고, 4 cm 정도 길었던 우측 다리의 길이도 좌우가 거의 같아졌다. 대상자2는 교정 전에는 무릎이 붙지가 않았고, 오른쪽 무릎이 왼쪽에 비해서 위로 5 cm 정도 올라갔었으며, 발목이 좌측에 비해서 30° 각도로 굽어져 있었는데, 교정 후에는 두 다리의 무릎이 안정되게 붙일 수 있게 되었고, 무릎의 높이도 같아 졌으며, 발목꺾임이 각도도 정상으로 교정이 되었다. 결론: 꾸준하게 기혈테라피와 척추교정 및 골반교정 기혈운동을 한다면 틀어졌던 체형도 바르게 회복되고, 아픈 통증도 완화되어 관련 질환들을 예방 및 치유하는데 효과가 있다고 본다.

PMSG를 이용한 풍력 발전 시스템의 3병렬 운전과 계통 연계 기술 (Three-Parallel System Operation and Grid-Connection Technique for High-Power Wind Turbines using a PMSG)

  • 이상혁;정해광;이교범;최세완;최우진
    • 전력전자학회논문지
    • /
    • 제15권4호
    • /
    • pp.296-308
    • /
    • 2010
  • 본 논문은 영구자석형 동기발전기를 이용한 풍력발전 시스템의 3병렬 운전과 계통연계 기술을 제안한다. 영구자석형 풍력발전 시스템에서 back-to-back 컨버터는 발전기와 계통에 직접 연결되므로 시스템 정격에 준하는 전력 반도체 소자와 필터가 요구된다. 본 논문은 시스템의 전력변환부를 3병렬로 연결하고 병렬 운전에 의해 발생할 수 있는 순환 전류는 적절한 내부 인덕터 선정으로 해결한다. 낮은 스위칭 주파수로 운전되는 대용량 풍력발전 시스템의 THD 규정을 만족시키기 위해 최적 설계된 LCL필터를 사용하고 LCL필터에 의해 발생할 수 있는 공진 문제는 전력이론을 통한 능동 댐핑 기법을 통하여 추가적인 손실 없이 보상한다. 또한 계통 왜곡 및 불평형 시 발생할 수 있는 전력 품질의 문제는 추가적인 보상 알고리즘을 적용하여 향상시킨다. 시뮬레이션 및 실험을 통하여 병렬 운전 시스템과 알고리즘의 타당성을 검증한다.