• Title/Summary/Keyword: distance measure method

Search Result 741, Processing Time 0.023 seconds

Utilization of Unmanned Aerial Scanner for Investigation and Management of Forest Area (산림지역 조사 및 관리를 위한 무인항공 스캐너의 활용)

  • Lee, Keun-Wang;Park, Joon-Kyu
    • Journal of Digital Convergence
    • /
    • v.17 no.11
    • /
    • pp.189-194
    • /
    • 2019
  • Forest investigation is the basic data for forest preservation and forest resource development, and periodical data acquisition and management have been performed. However, most of the current forest investigations in Korea are surveys to grasp the current status of forests, and various applications have not been made as geospatial information. In this study, the unmanned aerial scanner was used to acquire and process data in the forest area and to present an efficient forest survey method through analysis of the results. Unmanned aerial scanners can extract ground below vegetation, effectively creating DEM for forest management. It can be used as geospatial information for forest investigation and management by generating accurate topographical data that is impossible in conventional photogrammetry. It can also be used to measure distances between power lines and vegetation or manage transmission lines in forest areas. The accurate vertical distance measurement for vegetation surveys can greatly improve the accuracy of labor measurement and work efficiency compared to conventional methods. In the future, the use of unmanned aerial scanners will improve the data acquisition efficiency in forest areas, and will contribute to improved accuracy and economic feasibility compared to conventional methods.

Development of the Radiological Range of Positron Emitting Radionuclides (양전자 방출 핵종의 방사선학적 비정에 대한 제안)

  • Jang, Dong-Gun;Lee, Sang-Ho
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.849-853
    • /
    • 2021
  • PET images used in medical diagnoses are created using positron emitting radionuclides. The radiation used for imaging is generated at 0.511 MeV by p-annihilation. The CSDA range is the distance the particle radiation flew physically, and it is different from the range shown in PET images. This study proposes a novel method that uses radiological criteria to measure this range. The experiment was conducted by applying the MCNP6 simulation to positron emitting nuclides 18F, 11C, 13N, and 15O. Radiological criteria were based on the location of the p-annihilation event, which is also the image signal. Results showed the radiological range of positrons to be 2.3, 3.9, 5.0, and 7.9 mm for 18F, 11C, 13N, and 15O, respectively. The higher the positron energy, the larger its difference from the CSDA range. Positron emitting nuclide is being developed and studied as a nuclide for dosimetry or radiotherapy. Further research needs to be conducted into various positron ranges.

Vehicle Acceleration and Vehicle Spacing Calculation Method Used YOLO (YOLO기법을 사용한 차량가속도 및 차두거리 산출방법)

  • Jeong-won Gil;Jae-seong Hwang;Jae-Kyung Kwon;Choul-ki Lee
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.23 no.1
    • /
    • pp.82-96
    • /
    • 2024
  • While analyzing traffic flow, speed, traffic volume, and density are important macroscopic indicators, and acceleration and spacing are the important microscopic indicators. The speed and traffic volume can be collected with the currently installed traffic information collection devices. However, acceleration and spacing data are necessary for safety and autonomous driving but cannot be collected using the current traffic information collection devices. 'You Look Only Once'(YOLO), an object recognition technique, has excellent accuracy and real-time performance and is used in various fields, including the transportation field. In this study, to measure acceleration and spacing using YOLO, we developed a model that measures acceleration and spacing through changes in vehicle speed at each interval and the differences in the travel time between vehicles by setting the measurement intervals closely. It was confirmed that the range of acceleration and spacing is different depending on the traffic characteristics of each point, and a comparative analysis was performed according to the reference distance and screen angle to secure the measurement rate. The measurement interval was 20m, and the closer the angle was to a right angle, the higher the measurement rate. These results will contribute to the analysis of safety by intersection and the domestic vehicle behavior model.

Pattern Clustering of Symmetric Regional Cerebral Edema on Brain MRI in Patients with Hepatic Encephalopathy (간성뇌증 환자의 뇌 자기공명영상에서 대칭적인 지역 뇌부종 양상의 군집화)

  • Chun Geun Lim;Hui Joong Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.2
    • /
    • pp.381-393
    • /
    • 2024
  • Purpose Metabolic abnormalities in hepatic encephalopathy (HE) cause brain edema or demyelinating disease, resulting in symmetric regional cerebral edema (SRCE) on MRI. This study aimed to investigate the usefulness of the clustering analysis of SRCE in predicting the development of brain failure. Materials and Methods MR findings and clinical data of 98 consecutive patients with HE were retrospectively analyzed. The correlation between the 12 regions of SRCE was calculated using the phi (φ) coefficient, and the pattern was classified using hierarchical clustering using the φ2 distance measure and Ward's method. The classified patterns of SRCE were correlated with clinical parameters such as the model for end-stage liver disease (MELD) score and HE grade. Results Significant associations were found between 22 pairs of regions of interest, including the red nucleus and corpus callosum (φ = 0.81, p < 0.001), crus cerebri and red nucleus (φ = 0.72, p < 0.001), and red nucleus and dentate nucleus (φ = 0.66, p < 0.001). After hierarchical clustering, 24 cases were classified into Group I, 35 into Group II, and 39 into Group III. Group III had a higher MELD score (p = 0.04) and HE grade (p = 0.002) than Group I. Conclusion Our study demonstrates that the SRCE patterns can be useful in predicting hepatic preservation and the occurrence of cerebral failure in HE.

Dosimetric effects of couch attenuation and air gaps on prone breast radiation therapy (Prone Breast Phantom을 이용한 couch 산란영향 평가)

  • Kim, Min Seok;Jeon, Soo Dong;Bae, Sun Myeong;Baek, Geum Mun;Song, Heung Gwon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.2
    • /
    • pp.43-51
    • /
    • 2017
  • Purpose: The purpose of this study is to evaluate the dosimetric effects of couch attenuation and air gaps using 3D phantom for prone breast radiation therapy. Materials and method: A 3D printer(Builder Extreme 1000) and computed tomography (CT) images of a breast cancer patient were used to manufacture the customized breast phantom. Eclipse External Beam Planning 13.6 (Varian Medical Systems Palo Alto, CA, USA) was used to create the treatment plan with a dose of 200 cGy per fraction with 6 MV energy. The Optically Stimulated Luminescence Detector(OSLD) was used to measure the skin dose at four points (Med 1, Med 2, Lat 1, Lat 2) on the 3D phantom and ion-chamber (FC65-G) were used to perform the in-vivo dosimetry at the two points (Anterior, Posterior). The Skin dose and in-vivo dosimetry were measured with reference air gap (3 cm) and increased air gaps (1, 2, 3, 4, 5, 6 cm) from reference distance between the couch and 3D phantom. Results: As a result, measurement for the skin dose at lateral point showed a similar value within ${\pm}4%$ compared to the plan. While the air gap increased, skin dose at medial 1 was reduced. And it was also reduced over 7 % when the air gap was more than 3 cm compared to radiation therapy plan. At medial 2 it was reduced over 4 % as well. The changes of dose from variety of the air gap showed similar value within ${\pm}1%$ at posterior. As the air gap was increased, the dose at anterior was also increased and it was increased by 1 % from the air gap distance more than 3 cm. Conclusion: Dosimetrical measurement using 3D phantom is very useful to evaluate the dosimetric effects of couch attenuation and air gaps for prone breast radiation therapy. And it is possible to reduce the skin dose and increase the accuracy of the radiation dose delivery by appling the optimized air gap.

  • PDF

Video Scene Detection using Shot Clustering based on Visual Features (시각적 특징을 기반한 샷 클러스터링을 통한 비디오 씬 탐지 기법)

  • Shin, Dong-Wook;Kim, Tae-Hwan;Choi, Joong-Min
    • Journal of Intelligence and Information Systems
    • /
    • v.18 no.2
    • /
    • pp.47-60
    • /
    • 2012
  • Video data comes in the form of the unstructured and the complex structure. As the importance of efficient management and retrieval for video data increases, studies on the video parsing based on the visual features contained in the video contents are researched to reconstruct video data as the meaningful structure. The early studies on video parsing are focused on splitting video data into shots, but detecting the shot boundary defined with the physical boundary does not cosider the semantic association of video data. Recently, studies on structuralizing video shots having the semantic association to the video scene defined with the semantic boundary by utilizing clustering methods are actively progressed. Previous studies on detecting the video scene try to detect video scenes by utilizing clustering algorithms based on the similarity measure between video shots mainly depended on color features. However, the correct identification of a video shot or scene and the detection of the gradual transitions such as dissolve, fade and wipe are difficult because color features of video data contain a noise and are abruptly changed due to the intervention of an unexpected object. In this paper, to solve these problems, we propose the Scene Detector by using Color histogram, corner Edge and Object color histogram (SDCEO) that clusters similar shots organizing same event based on visual features including the color histogram, the corner edge and the object color histogram to detect video scenes. The SDCEO is worthy of notice in a sense that it uses the edge feature with the color feature, and as a result, it effectively detects the gradual transitions as well as the abrupt transitions. The SDCEO consists of the Shot Bound Identifier and the Video Scene Detector. The Shot Bound Identifier is comprised of the Color Histogram Analysis step and the Corner Edge Analysis step. In the Color Histogram Analysis step, SDCEO uses the color histogram feature to organizing shot boundaries. The color histogram, recording the percentage of each quantized color among all pixels in a frame, are chosen for their good performance, as also reported in other work of content-based image and video analysis. To organize shot boundaries, SDCEO joins associated sequential frames into shot boundaries by measuring the similarity of the color histogram between frames. In the Corner Edge Analysis step, SDCEO identifies the final shot boundaries by using the corner edge feature. SDCEO detect associated shot boundaries comparing the corner edge feature between the last frame of previous shot boundary and the first frame of next shot boundary. In the Key-frame Extraction step, SDCEO compares each frame with all frames and measures the similarity by using histogram euclidean distance, and then select the frame the most similar with all frames contained in same shot boundary as the key-frame. Video Scene Detector clusters associated shots organizing same event by utilizing the hierarchical agglomerative clustering method based on the visual features including the color histogram and the object color histogram. After detecting video scenes, SDCEO organizes final video scene by repetitive clustering until the simiarity distance between shot boundaries less than the threshold h. In this paper, we construct the prototype of SDCEO and experiments are carried out with the baseline data that are manually constructed, and the experimental results that the precision of shot boundary detection is 93.3% and the precision of video scene detection is 83.3% are satisfactory.

A study on correlation of teaching efficiency and satisfaction of clinical training in Daegu (임상실습교육의 교수효율성과 임상실습만족도에 관한 상관성 연구 (대구지역을 중심으로))

  • Kim, Jeong-Sook;Jung, Young-Hae
    • Journal of Technologic Dentistry
    • /
    • v.28 no.1
    • /
    • pp.121-142
    • /
    • 2006
  • Collecting materials for study on teaching efficiency and satisfaction of clinical training, it changes. Dental technology's educational procedure to many ways of a prospect. In a circumstance that needed higher level of education, this study is aimed on realizing an importance of clinical training through the various materials that previously carried out and offering basic knowledge to take better clinical training for the students. Study results below 1. This Investigation conducted on 123 of sophomores(70.3%) and 52 of juniors(29.7%) who have been taken clinical training, and men's proportion(51.45%)is a bit higher than girls(48.6%). The 64% of respondents taken largest proportion were 20 to 24 years old. As 67.9% of respondents attended daytime school and 30.3% of them attended nighttime one, their school time shows a little difference. In a question about relation ship, one answered "Harmonious" took largest proportion by 72.6% during training, and about the degree of satisfaction of campus life who answered "normal" were the most with 59.4%. 2. About the reason choosing dental technology as a major, 41.1% taken the most answered "due to the specialized job", "Getting job easily" was second with 26.9%, and third was "recommended from around" with 18.3%. 50.3% of the respondents answered "normal" about the Satisfaction of their major, student marked in grade "B" most with 51.4% 3. In a investigation result about clinical training statues and preference, most(72.6%) choose place less than 10 for clinical training, and 60.6% of them resided own home. About their commuting time from home to training place, 44% was under 30min, 40% took time 30-60min. It shows students prefer shotter distance in terms of choosing training place. 4. Each part manager took large proportion as a clinical trainer with 33.7%, Training curriculum reform and developing method were most answer as a improvement measure after completing training with 30%. 5. The average of total score about clinical training was 3.15 of 5. In the detailed question, 'satisfaction of clinical training' got 3.38 as a highest score, the lowest score was 2.86 that is about satisfaction of clinical training period. The average score about efficiency of study was 2.86 and in detailed question, 'a Role model' got 3.26 as a highest score and participation of student got 3.05 as a lowest score. 6. The result of T-test to see the difference of the satisfaction according to the general character and clinic training condition between teaching efficiency is that the degree of satisfaction of clinical training showed statistical significance only in the degree of satisfaction of campus life(p<0.05), and teaching efficiency has a statistical significance with their age, grade, and satisfaction of campus life (p<0.05). 7. The relation between of teaching efficiency of clinical training and satisfaction of clinical training of dental technologic student has a statistical meaning in significance leveler 0.01. Now, therefore we suggest following based on these result. 1. To elevate satisfaction of clinical training, it agentry needs development of consistent clinical training curriculum. 2. To grasp the satisfaction and requirement, in needs to measure anxiousness and satisfactory degree after completing training 3. To train efficiently and evaluate efficiency over the teaching activities, it needs to develop measuring tools for teaching efficiency in terms of teacher's important rules in a clinical training. 4. Strengthen the relations with the study developing and managing curriculum gathering theoretical knowledge and practice. And make an effort to apply to their students. 5. Let the trainee take a class setting a belief, sense of value, function and obtain behavior by making the students comfort over clinical training as increasing teaching efficiency.

  • PDF

The Comparison Research of the Head and Face on the 30's, 40's, and the 50's, 60's in Korean Men according to Sasang Constitution (한국인(韓國人) 남자(男子) 30-40대(代)와 50-60대(代)의 사상체질별(四象體質別) 안면형태(顔面形態)에 관(關)한 비교(比較) 연구(硏究))

  • Lim, Kyu-Seong;Kim, Sang-Bok;Lee, Jun-Hee;Park, Gye-Soo;Lee, Su-Kyung;Lee, Eui-Ju;Koh, Byung-Hee;Song, Il-Byung;Yun, Jong-Hyun
    • Journal of Sasang Constitutional Medicine
    • /
    • v.12 no.2
    • /
    • pp.143-152
    • /
    • 2000
  • 1. Background and Purpose The faces of human being change as they grow older. We could know the characters of the each ages, through the facial comparison between the 30's, 40's and the 50's, 60's. As a conclusion, I carried out this Study because I thought that the errors of diagnosis would be reduced a lot through the standardization researches about the morphology of faces. 2. Objectives The object of this study is selected from the patients who were already diagnosed Sasang Constitutions at the department of Sasang Constitutional Medicine in Kyunghee Oriental Medical Center. The number of the patients were 69 men in 30's and 40's, and 74 men in 50's and 60's. 3. Method I took the photographs of front view and lateral view of the objectives by digital camera and obtained the 200 measure through the facial measurement program. I compared the measure of 50's and 60's with 30's and 40's by independant t-test. 4. Results 28 measures are different 30's and 40's with 50's and 60's in Soyangin, 31 measures in Soeumin, 40 measures in Taeumin. 5. Conclusion (1) Soyangin showed wider interpupillary distance in 30's and 40's than 50's and 60's. They also showed the large brow and cheek and their lips were thick and prominent and their ophyrion were prominent and their noses were wide and large and they showed wide bigonial breadth in 30's and 40's than 50's and 60's. (2) Soeumin showed the position of ears were higher and the brows were longer and larger in 30's and 40's than 50's and 60's. The width of both eyebrow were wider in 50's and 60's than 30's and 40's. The lower 2/3 portion of the face was longer and the shape of head was longer in vertical in 50's and 60's than 30's and 40's. (3) Taeumin showed the wider brow in 30's and 40's than 50's and 60's. The width of each eyes was wider and the width of cheek and face was larger, too. The ophyrion was prominent and the mouth was bigger and the face showed longer in 50's and 60's than 30's and 40's. (4) The upper 1/3 portion of the face was large in 30's and 40's and the lower 2/3 portion of the face showed large and long in 50's and 60's regardless Constitution.

  • PDF

Improvement of GPS positioning accuracy by static post-processing method (정적 후처리방식에 의한 GPS의 측위정도 개선)

  • 김민선;신현옥
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.39 no.4
    • /
    • pp.251-261
    • /
    • 2003
  • To measure the GPS position accuracy and its distribution according to the length of the baseline, 30 minutes to 24 hours observations at the fixed location were conducted with two GPS receivers (Ll, 12 channels) on May 29 to June 2, 2002. The GPS data received at the reference station, the rover station and the ordinary times GPS observation station operated by the National Geography Institute in Korea were processed in kinematic and static post-processing methods with a post -processing software. The results obtained are summarized as follows: 1. The number of the satellite that could be observed continuously more than six hours was 16 and most of these satellites were positioned at east-west direction on May 31, 2002. The number of the satellite observed and the geometric dilution of precision (GDOP) determined by the average of every 10 minute for the day were 8 and 3.89, respectively. 2. Both the average GPS positions before and after post-processing were shifted (standalone: 1.17 m, post -processing: 0.43m) to the south and west. The twice distance root mean square (2drms) measured with standalone was 6.65m. The 2drms could be reduced to 33.8% (standard deviation 0=17.2) and 5.3% (0=2.2) of standalone by the kinematic and the static post-processing methods, respectively. 3. The relationship between the length of the baseline x (km) and the 2drms y (m) obtained by the static post-processing method was y=0.00l6x+0.006 $(R^2=0.87)$. In the case of the positioning with the static post-processing method using the GPS receiver, it was found that a positioning within 20cm 2drms was possible when the length of the baseline was less than 100km and the receiving time of the GPS is more than 30 minutes.

Evaluate the Change of Body Shape and the Patient Alignment State During Image-Guided Volumetric Modulated Arc Therapy in Head and Neck Cancer Patients (두경부 환자의 VMAT 시 체형변화와 환자 정렬과의 상관관계 고찰)

  • Seo, Se Jeong;Kim, Tae Woo;Choi, Min Ho;Son, Jong Gi
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.2
    • /
    • pp.109-117
    • /
    • 2017
  • Objectives: The purpose of this study was to evaluate the change of body shape and the patient alignment state during image-guided volumetric modulated arc therapy in head and neck cancer patients, Materials and Methods: We performed a image-guided volumetric modulated arc therapy plan for 89 patients with head and neck cancer who underwent curative radiotherapy. Ten of them were evaluated for set up error. The landmarks of the ramus, chin, posterior neck, and clavicle were specified using ARIA software (Offline review), and the positional difference was analyzed. Results: The re-CT simulation therapy was performed in 60 men with $17{\pm}4$ cycles of treatment. The weight loss rate was $-6.47{\pm}3.5%$. 29 women performed re-CT simulation at $17{\pm}5$ cycles As a result, weight loss rate was $-5.73{\pm}2.7%$. The distance from skin to C1, C3, and C5 was measured, and both clavicle levels were observed to measure the skin shrinkage changes. The skin shrinkage standard deviations were C1 (${\pm}0.44cm$), C3 (${\pm}0.83cm$), and C5 (${\pm}1.35cm$), which is about 1 mm shrinkage per 0.5 kg reduction. Skin shrinkage according to the number of treatments was 1 ~ 4 fractions (no change), 5 ~ 13 fractions (-2 mm), 14 ~ 22 fractions (-4 mm) and 23 ~ 30 fractions (-6 mm). Conclusion: When the body shape changes about 5 mm, the central dose starts to differ about 3 % or more. Therefore, the CT simulation treatment for the adaptive therapy should be additionally performed. In addition, it is necessary to actively study the CT simulation therapy method and set up method of the lower neck and to examine the use of a new immobilization device.

  • PDF