• Title/Summary/Keyword: distance between frames

Search Result 94, Processing Time 0.024 seconds

Comparison of Biomechanical Characteristics for the Skill Level in Cycle Pedaling

  • Lee, Geun-Hyuk;Kim, Jai-Jeong;Kang, Sung-Sun;Hong, Ah-Reum;So, Jae-Moo
    • Korean Journal of Applied Biomechanics
    • /
    • v.26 no.1
    • /
    • pp.11-20
    • /
    • 2016
  • Objective: This study aimed to compare biomechanical data between elite and beginner cyclists during cycle pedaling by performing a comparative analysis and to provide quantitative data for both pedaling performance enhancement and injury prevention. Methods: The subjects of this study included 5 elite cyclists (age: $18{\pm}0years$, body mass: $64.8{\pm}9.52kg$, height: $173.0{\pm}4.80cm$) and 5 amateur cyclists (age: $20{\pm}0years$, mass: $66.6{\pm}2.36kg$, height: $175.6{\pm}1.95cm$). The subjects pedaled on a stationary bicycle mounted on rollers of the same gear (front: 50 T and rear: 17 T = 2.94) and cadence of 90. The saddle height was adjusted to fit the body of each subject, and all the subjects wore shoes with cleats. In order to obtain kinematic data, 4 cameras (GR-HD1KR, JVC, Japan) were installed and set at 60 frames/sec. An electromyography (EMG) system (Telemyo 2400T, Noraxon, USA) was used to measure muscle activation. Eight sets of data from both the left and right lower extremities were obtained from 4 muscles (vastus medialis oblique [VMO], vastus lateralis oblique [VLO], and semitendinosus [Semitend], and lateral gastrocnemius [Gastro]) bilaterally by using a sampling frequency of 1,500 Hz. Five sets of events ($0^{\circ}$, $90^{\circ}$, $180^{\circ}$, $270^{\circ}$, and $360^{\circ}$) and 4 phases (P1, P2, P3, and P4) were set up for the data analysis. Imaging data were analyzed for kinematic factors by using the Kwon3D XP computer software (Visol, Korea). MyoResearch XP Master Edition (Noraxon) was used for filtering and processing EMG signals. Results: The angular velocity at $360^{\circ}$ from the feet was higher in the amateur cyclists, but accelerations at $90^{\circ}$ and $180^{\circ}$ were higher in the elite cyclists. The amateur cyclists had greater joint angles at $270^{\circ}$ from the ankle and wider knee joint distance at $0^{\circ}$, $180^{\circ}$, and $360^{\circ}$ than the elite cyclists. The EMG measurements showed significant differences between P2 and P4 from both the right VLO and Semitend. Conclusion: This study showed that lower body movements appeared to be different according to the level of cycle pedaling experience. This finding may be used to improve pedaling performance and prevent injuries among cyclists.

Measurement Technique of Indoor location Based on Markerless applicable to AR (AR에 적용 가능한 마커리스 기반의 실내 위치 측정 기법)

  • Kim, Jae-Hyeong;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.25 no.2
    • /
    • pp.243-251
    • /
    • 2021
  • In this paper, we propose a measurement technique of indoor location based on markerless applicable to AR. The proposed technique has the following originality. The first is to extract feature points and use them to generate local patches to enable faster computation by learning and using only local patches that are more useful than the surroundings without learning the entire image. Second, learning is performed through deep learning using the convolution neural network structure to improve accuracy by reducing the error rate. Third, unlike the existing feature point matching technique, it enables indoor location measurement including left and right movement. Fourth, since the indoor location is newly measured every frame, errors occurring in the front side during movement are prevented from accumulating. Therefore, it has the advantage that the error between the final arrival point and the predicted indoor location does not increase even if the moving distance increases. As a result of the experiment conducted to evaluate the time required and accuracy of the measurement technique of indoor location based on markerless applicable to AR proposed in this paper, the difference between the actual indoor location and the measured indoor location is an average of 12.8cm and a maximum of 21.2cm. As measured, the indoor location measurement accuracy was better than that of the existing IEEE paper. In addition, it was determined that it was possible to measure the user's indoor location in real time by displaying the measured result at 20 frames per second.

Unchosen Cohabitation of Hannah Arendt and Precarity Politics of Judith Butler: Based on Body Politic and Ethical Obligation (한나 아렌트의 비선택적 공거와 주디스 버틀러의 프레카리티 정치학: 몸의 정치학과 윤리적 의무)

  • Cho, Hyun June
    • Cross-Cultural Studies
    • /
    • v.48
    • /
    • pp.361-389
    • /
    • 2017
  • This essay examines 'precarity politics' by Judith Butler, a well-known gender theorist and queer philosopher, in Notes Towards a Performative Theory of Assembly (2015) focused on concepts as unchosen cohabitation of Hannah Arendt and unwilled proximity of Emmanuel Levinas. Butler's precarity politics is the condition of our dispossessed political beings with fundamental vulnerability and interdependency that cannot choose with whom we will live on this Earth. Butler's political ethics is twofold: on one hand, she examines significance of 'action'' the most significant vita activa in the public area, and 'plurality'' the condition-not only the necessary condition but the possible condition-for a political life suggested by Hannah Arendt in Human Condition; on the other hand, Butler reflects upon global precarity based on a diasporic precarious life in the social world towards freedom and equality. Unchosen cohabitation of plural humans on Earth, and global pervasion of precarity, that indicates "politically induced condition in which certain populations suffer from failing social and economic networks of support and become differentially exposed to injury, violence, and death," so called "differential distribution of precariousness," are practical possibilities of ethical and equal cohabitation of different ethnic groups in the social world. Ethical obligations or ethical demand to respond to others' suffering in distance and proximity originated from precarity politics, mentioned in Precarious Life, Parting Ways, and Frames of War, could be non-foundational joint of plural people living together globally. We should presume the 'reversibility' of distance and proximity in others' suffering, based on responsiveness and responsibility of others, if we want to stay attuned to the pain of others we never chose to live together. That is the significance of Butler's 'precarity politics' with 'ethical obligation' to accept 'unchosen plurality' of living population on Earth, and 'reversibility between of distance and proximity,' in her 'new plural and embodied body politics' or 'new corporeal ontology', through human primary vulnerability, fundamental interdependency, being exposed and responsive to suffering of others.

Induced Prism by the Categories of Spectacle Frames (안경테 종류에 따른 유발프리즘)

  • Park, Woo-Jung;Kim, Soo Woon;Hwang, Hae-Young;Yu, Dong-Sik;Son, Jeong-Sik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.3
    • /
    • pp.311-319
    • /
    • 2012
  • Purpose: One of the critical aspects on dispensing glasses is to match the center of pupils to the optical center of lenses as the mismatched glasses are able to induce uncomfortable effects called prism which has been known to induce phoria, a main cause for asthenopia in many cases. Therefore, we investigated the induced prism occurred by mismatching centers between the center of pupils and the optical center of lenses. Methods: In this study, total 103 subjects were examined whether the center of pupils and the optical center of lenses are matched in horizontal and vertical directions, and then, the data was categorized into 4 groups based on the structural components of glasses. Total amount of prism was compared to show the effect of the glasses frame on the prism induction, and the value of measured prism was compared with the German RAL-RG 915 regulations. Results: The results in respect to the horizontal component showed that the induced prism was not found in 10.7% of total subjects. 73.8% of total subjects were influenced by induced prism, the range of prism was in a tolerance level. However, the 15.5% of total subjects seemed to be influenced by prism which is out of the criterion of tolerance. In case of vertical component, 23.3% of total subjects showed no effects of prism while early adopting glasses, 54.4% of total subjects showed a little prism effect within the criterion of tolerance, and 22.3% of total subjects showed the prism effect out of the tolerance range. This data indicates that group A and B that are less likely adjustable by fitting induce more prism than group C and D in horizontal and vertical components. Conclusions: In higher refractive error condition, it was found that aligning the optical center of lenses with the center of pupils by pre-fitting of glasses frame minimized prism induction in horizontal and vertical components, which ameliorates ocular fatigue. Therefore, appropriate optometric dispensing through fitting by opticians and precise design about monocular PD and monocular Oh are necessary to improve visual perception.