• 제목/요약/키워드: dissolved hydrogen concentration

검색결과 71건 처리시간 0.023초

핵연료 피복관 부식생성물 부착에 대한 용존수소의 영향 (Effect of Dissolved Hydrogen on Fuel Crud Deposition)

  • 백승헌;김우철;심희상;임경수;원창환;허도행
    • Corrosion Science and Technology
    • /
    • 제13권2호
    • /
    • pp.56-61
    • /
    • 2014
  • The purpose of this work is to investigate the effect of dissolved hydrogen concentration on crud deposition onto the fuel cladding surface in the simulated primary environments of a pressurized water reactor. Crud deposition tests were conducted in the dissolved hydrogen concentration range of 5~70 cc/kg at $325^{\circ}C$ for 14 days. Needle-shaped NiO deposits were formed in the hydrogen range of 5~25 cc/kg, while polygonal nickel ferrite deposits were observed at a hydrogen concentration above 35 cc/kg. However, the dissolved hydrogen content seems to have little effect on the amount of crud deposits.

Electrochemical behavior of dissolved hydrogen at Pt electrode surface in a high temperature LiOH-H3BO3 solution: Effect of chloride ion on the transient current of the dissolved hydrogen

  • Myung-Hee Yun;Jei-Won Yeon
    • Nuclear Engineering and Technology
    • /
    • 제55권10호
    • /
    • pp.3659-3664
    • /
    • 2023
  • The electrochemical behavior of dissolved hydrogen (H2) was investigated at a Pt electrode in a high temperature LiOH-H3BO3 solution. The diffusion current of the H2 oxidation was proportional to the concentration of the dissolved H2 as well as the reciprocal of the temperature. In the polarization curve, a potential region in which the oxidation current decreases despite an increase in the applied potential between the H2 oxidation and the water oxidation regions was observed. This potential region was interpreted as being caused by the formation of a Pt oxide layer. Using the properties of the Cl- ion that reduces the growth rate of the Pt oxide layer, it was confirmed that there is a correlation between the Cl- ion concentration and the transient current of the H2 oxidation.

Novel oxygenation for lipopeptide production from Bacillus sp. GB16

  • Lee, Baek-Seok;Lee, Jae-Woo;Shin, Haw-Shook;Choi, Sung-Won;Choi, Ki-Hyun;Lee, Jae-Ho;Kim, Eun-Ki
    • 한국생물공학회:학술대회논문집
    • /
    • 한국생물공학회 2003년도 생물공학의 동향(XII)
    • /
    • pp.240-244
    • /
    • 2003
  • A novel integrated method for increasing dissolved oxygen concentration in culture media has been developed. It involves adding hydrogen peroxide to the medium, which is then decomposed to oxygen and water by catalase and adding vegetable oil to the medium as antifoam agent and oxygen vector. A new apparatus for automated addition of hydrogen peroxide to the bioreactor to keep the dissolved oxygen concentration constant over the range $10-100%\;{\pm}\;5%$ was tested. A significant increase (over threefold) of cultivation time was obtained while the dissolved oxygen concentration remained stable ($30%\;{\pm}\;5%$). Therefore, use of corn oil mixed with Ca-stearate as oxygen vector and antifoam and hydrogen peroxide as oxygen source to control excessive foam that was generated by microorganism biosurfactant, GB16-BS produced at Bacillus sp. GB16 cultivation was appropriate for stable cultivation.

  • PDF

팔라듐이 코팅된 광섬유 격자를 이용한 절연유속의 용존 수소가스 검출 (Detection of Hydrogen Gas Dissolved in Insulation Oil Based on Palladium-coated Fiber Bragg Grating)

  • 김광택;최누리;백세종
    • 센서학회지
    • /
    • 제27권6호
    • /
    • pp.403-406
    • /
    • 2018
  • We have investigated a fiber-optic sensor for detecting the hydrogen gas dissolved in insulation oil based on a palladium (Pd)-coated fiber Bragg grating (FBG). As the palladium absorbs the hydrogen gas dissolved in the insulation oil, its volume expands and the Bragg wavelength shifts to a longer wavelength. The experimental results showed that the Bragg wavelength of FBG increased to 70 nm when the concentration of hydrogen dissolved in the insulation oil was 409 ppm.

온도의 영향에 따른 니켈페라이트의 입자 크기 분포 연구 (A Study on Effect of Temperature on Particle Size Distribution of Nickel Ferrite)

  • 안현경;이인형;정현준;박병기
    • 한국산학기술학회논문지
    • /
    • 제9권6호
    • /
    • pp.1768-1774
    • /
    • 2008
  • PWR 정지화학 조건에서 모사실험하여 니켈페라이트 입자의 거동을 조사하였다. 농도가 Li 0.1 ppm, B 2000 ppm인 모사실험 용액의 온도는 $300^{\circ}C$에서 $0.625^{\circ}C/min$의 비율로 $150^{\circ}C$까지 감소시킨 후 일정 시간 동안 $150^{\circ}C$를 유지하였고 이때의 압력은 2500psi 이하로 유지하였다. 수소 농도 5, 15, 25 cc/kg $H_2O$ 일 때 온라인으로 입자 분포를 측정하였고 용해된 니켈 농도도 분석하였다. 실험결과 온도 감소 시 세 가지 수소 농도일 때 모두 총입자 수는 큰 변화가 없었다. 그러나 온도가 감소하고 일정하게 유지될 때 입자는 작아졌다. 입자 크기 분포 변화의 정도는 $H_2$ 15cc/kg $H_2O$ 일 때가 가장 크게 나타났다. 니켈 이온의 농도는 온도가 감소하고 수소 15 cc/kg $H_2O$ 일 때 증가하였다. 이 결과 니켈 페라이트는 온도 변화 시, 수소 15 cc/kg $H_2O$ 일 때 불안정 한 것으로 보여 진다.

Solid Electrochemical Method of Measuring Hydrogen Concentration with O2-/H+ Hetero-Ionic Junction

  • Chongook Park
    • 센서학회지
    • /
    • 제33권2호
    • /
    • pp.63-69
    • /
    • 2024
  • A novel method for measuring hydrogen concentration is introduced, along with its working principle and a novel detection algorithm. This configuration requires no additional reference compartment for potentiometric electrochemical measurements; therefore, it is the most suitable for measuring dissolved hydrogen in the liquid phase. The sensor's electromotive force saturates at a certain point, depending on the hydrogen concentration during the heating process of the sensor operation. This dynamic temperature scanning method provides higher sensitivity than the constant temperature measurement method.

FET형 용존산소 센서 어레이 측정시스템 (A Dissolved Oxygen Measurement System Using FET-type Dissolved Oxygen Sensor Array)

  • 정훈;손병기
    • 센서학회지
    • /
    • 제10권4호
    • /
    • pp.259-265
    • /
    • 2001
  • FET형 용존산소 센서는 pH-ISFET를 기본 소자로하여 pH 감지 게이트 근처에 백금으로 된 작업 전극을 형성한 구조를 가지고 있다. 작업전극에 특정한 전위를 인가하면 전기분해로 인하여 용존산소의 농도에 비례하는 수소 이온이 pH 감지 게이트 주변에 발생된다. 따라서 pH-ISFET를 통하여 수소 이온 농도의 변화량을 검출하면 용존산소의 농도를 측정할 수 있게된다. 본 논문에서는 이러한 FET형 용존산소 센서를 어레이 형태로 제작하여 적용하고 측정의 신뢰성을 높이기 위한 알고리즘을 도입한 FET형 용존산소 센서 어레이 측정 시스템을 개발하였다. 또한 상용 용존산소 측정기와 그 성능을 비교 분석하였다.

  • PDF

유중 용존수소 감지를 위한 Pd/NiCr 게이트 MISFET 센서의 제작 (Fabrication of Pd/NiCr gate MISFET sensor for detecting hydrogen dissolved in Oil.)

  • 김갑식;이재곤;함성호;최시영
    • 센서학회지
    • /
    • 제6권3호
    • /
    • pp.221-227
    • /
    • 1997
  • Pd/NiCr 게이트 MISFET 센서는 변압기 절연유중 용존수소를 감지하기 위해 제조되었다. 센서의 안정성과 고농도 감지성의 향상을 위해 Pd/NiCr 2중 촉매 금속 게이트가 사용되었다. 수소유입에 의한 게이트 전압의 드리프트를 줄이기 위해, 2개의 FET 게이트 절연층을 실리콘 산화막과 실리콘 질화막의 2중 구조로 하였다. Pd/NiCr 게이트 MISFET 센서의 수소 감응 감도는 Pd/Pt 게이트 MISFET 센서의 감도에 비해 약 0.5배이나, 안정성이 좋고, 1000 ppm까지의 고농도까지 측정할 수 있었다.

  • PDF

제주도 한라산 남북측 사면 용천수의 수리지구화학

  • 이광식;박원배;현승규;김용제;문덕철;김구영
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2004년도 총회 및 춘계학술발표회
    • /
    • pp.408-412
    • /
    • 2004
  • A total of 23 springs distributed in the southern and northern sides of Mt. Hala in Jeju Island were seasonally sampled and analyzed for their major ion chemistry and oxygen and hydrogen isotope compositions to investigate their hydrogeochemical and isotopic characteristics. Dissolved ion concentrations of the south-side springs slightly increase with decreasing altitude. This indicates that dissolved ion concentrations of groundwater recharged at higher altitudes increase by water-rock interaction during the downgradient migration of groundwater through highly permeable volcanic aquifer. Dissolved ion concentrations of the north-side springs also slightly increase with decreasing altitude, but dramatically increase at ~300 m.a.s.l. This may indicate a sudden input of contaminants to the north-side groundwater system around ~300 m.a.s.l. Springs located in areas above ~300 m.a.s.l. have very low concentrations of dissolved ions, showing little seasonal variations. Whereas springs located in areas below ~300 m.a.s.l. show a big seasonal variation in the concentration of dissolved ions. Seasonal variation of oxygen isotope compositions of springs is ~3$\textperthousand$ for high-altitude springs (~1700 m.a.s.l.) and is ~2$\textperthousand$ near shore, indicating an attenuation of the variation through mixing with other groundwater bodies during migration.

  • PDF

정수처리에서 생물활성탄의 전처리로서 고급산화처리법의 평가 (Evaluation of Advanced Oxidation Process(AOP) as a Pretreatment Process of Biological Activated Carbon in Drinking Water Treatment)

  • 김우항
    • 한국환경과학회지
    • /
    • 제8권6호
    • /
    • pp.725-730
    • /
    • 1999
  • The advanced oxidation process (AOP) using ozone combined with hydrogen peroxide and ultraviolet treatment were evaluated for biodegradable dissolved organic carbon (EDOC) formation and dissolved organic carbon (DOC) removal. Oxidation treatment were conducted alone or combination with ozone, hydrogen peroxide and ultraviolet processes. Ozone dosage of ozone process was varied from $0.5mg/l{\ell}\cdot}min$ to $5mg/{\ell}{\cdot}min$. Ozone/hydrogen peroxide process was done using $20mg/{\ell}{\cdot}min$ of hydrogen peroxide concentration. Ozone/ultraviolet process was irradiated with $12mW/cm^2$ of density and 254nm. Ozone dosage was varied from $0.5mg/{\ell}{\cdot}min$ to $5mg/{\ell}{\cdot}min$ at the ozone/hydrogen peroxide and ozone/ultraviolet processes too. Contact time of all the process was 20 minutes. Oxidation treatment were performed on microfiltration effluent samples. BDOC formation was reached to an optimum at ozone dosage of $1.5mg/{\ell}{\cdot}min$ in the ozone/hydrogen peroxide process and $1mg/{\ell}{\cdot}min$ in ozone/ultraviolet process, after which BDOC formation was decreased at higher ozone dosages. But BDOC formation was increased with ozone dosages increasing in ozone process. The efficiency of DOC removal was higher AOPs than ozone process. Ozone/ultraviolet proces was the highest for DOC removal efficiency in each process. THMFP. removal efficiency by ozone/ultraviolet process was higher than that by each of ozone process and ozone/hydrogen peroxide process.

  • PDF