• 제목/요약/키워드: dissolution cavity

검색결과 17건 처리시간 0.021초

텅스텐 미세 전극을 이용한 전해 가공 (Electrochemical Machining Using Tungsten Microelectrode)

  • 류시형;유종선
    • 한국정밀공학회지
    • /
    • 제26권4호
    • /
    • pp.134-140
    • /
    • 2009
  • The feasibility of electrochemical drilling and milling on stainless steel are investigated using tungsten microelectrode with $10{\mu}m$ in diameter. For the development of environmentally friendly and safe electrochemical process, citric acid solution is used as electrolyte. A few hundred nanoseconds duration pulses are applied between the microelectrode and work material for dissolution localization. Tool fracture by Joule heating, micro welding, capillary phenomenon, tool wandering by the generated bubbles are observed and their effects on micro ECM are discussed. Occasionally, complex textures including micro pitting corrosion marks appeared on the hole inner surface. Metal growth is also observed under the weak electric conditions and it hinders further dissolutions for workpiece penetration. By adjusting appropriate pulse and chemical conditions, micro holes of $37{\mu}m$ in diameter with $100{\mu}m$ in depth and 26Jim in diameter with $50{\mu}m$ in depth are drilled on stainless steel 304. Also, micro grooves with $18{\mu}m$ width and complex micro hand pattern are machined by electrochemical milling.

Sealed amalgam restoration의 미세누출에 관한 연구 (A STUDY ON MICROLEAKAGE OF SEALED AMALGAM RESTORATION)

  • 이상헌;이재천;이상훈
    • 대한소아치과학회지
    • /
    • 제27권1호
    • /
    • pp.54-61
    • /
    • 2000
  • 아말감은 널리 사용되어 온 대표적 치과재료이지만 치질과의 접착성이 없어 와동의 형태에 의해 유지되는 단점을 가진다. 아말감 수복물은 산화물에 의한 변연봉쇄가 일어나기 전까지 초기에 큰 미세누출을 보이며 수복초기에 이를 적절하게 예방하지 않으면 타액이나 미생물이 와동내에 침투하게 되고 이로 인해 수복 후의 과민반응, 충전물의 용해 및 파괴, 변연 변색과 2차 우식이 유발되어, 결과적으로 수복물의 수명이 단축되며 치수 병변이 발생될 수도 있다. 최근 기존 아말감 수복의 장점을 그대로 유지하면서 치질삭제를 줄이고 변연을 봉쇄하며 소와열구에 예방적 처치를 함께 할 수 있는 수복법이 제안되었는데 이를 이른바 sealed amalgam이라 한다. 이 술식은 예방적 확대 없이 병소만을 제거한 뒤 수복물 변연과 인접 소와열구에 치면열구전색재를 도포함으로서 소와열구의 예방적 충전은 물론 수복물 변연과 치질사이의 틈을 봉쇄하여 미세누출을 감소시킬 수 있다고 하였다. 이에 저자는 아말감 수복후 수복물의 마무리 처리와 전색재 적용시점을 달리 하여 sealed amalgam 수복과 기존의 아말감 수복과의 미세누출의 차이를 비교하고자 30개의 상, 하악 소구치를 준비하여 V급 와동을 소구치의 협, 설측에 형성하고 통상적 아말감 수복을 시행한 후 다음의 각 군으로 나누어 처리하였다. 제 1 군 : 24시간 후 연마 (대조군) 제 2 군 : 연마하지 않음, 즉시 전색재 적용 제 3 군 : 연마하지 않음, 열순환(thermocycling) 500회 후 전색재 적용 위의 처리 후 각 군을 $5^{\circ}C$$55^{\circ}C$의 온도변화를 30초씩 번갈아 주며 총 500회의 열순환을 실시한 후 1% methylene blue 용액에 침윤시켜서 100% 습도가 유지된 $37^{\circ}C$ 항온기에 24시간 보관하였다. 치아를 레진에 매몰한 후 협설측으로 치아 장축에 평행하게 절단하여 stereomicroscope를 사용해 색소침투도를 관찰하여 다음과 같은 결론을 얻었다. 1. 평균 미세누출은 연마하지 않고 바로 치면열구전색재를 도포한 2군이 가장 낮았고, 연마만 시행한 1군이 가장 높았다. 2. 실험군간의 미세누출 비교에서 연마만 시행한 1군은 2군에 비해 미세누출이 켰으며 통계적으로 유의성 있는 차이를 보였다(p<0.05). 3군은 1군보다 평균미세누출이 작았으나 통계적으로 유의한 차이가 없었다(p>0.05). 2군은 3군보다 평균 미세누출이 작았으나 통계적으로 유의한 차이가 없었다(p>0.05).

  • PDF

수종의 레진 시멘트의 용해도와 수분흡착에 관한 연구 (A STUDY ON THE SOLUBILITY AND THE WATER SORPTION OF VARIOUS RESIN CEMENTS)

  • 황유진;조인호;임주환;임헌송
    • 대한치과보철학회지
    • /
    • 제43권1호
    • /
    • pp.1-14
    • /
    • 2005
  • Statement of problem. Among the physical properties of adhesion luting cement, the aspect that requires the most important factor is the degree of solubility and water sorption. Dissolution or an inadequate due to excessive water sorption inside the oral cavity compromises the while concurrently increasing the susceptibility to secondary dental caries. Susceptibility to dissolution and difficulty of removing remnant cement from the gingival sulcus have hindered the use of dental resin cement in the clinical practice, but the improved characteristics of newer generation resin cements have interest in and enabled resin cements to be widely used in adhesion of fixed prosthesis, such as laminate veneers and all-ceramic crowns. Purpose. The purpose of this study is to compare and analyze the degrees of solubility and water sorption of a variety of resin cements widely used for clinical purposes with different curing methods. Material and methods. Self-curing resin cements, $Avanto^{(R)}$, $C&B^{TM}$ CEMENT and Superbond C&B cements comprised group 1, 2 and 3. The dual-curing resin cements $Panavian^{TM}$ F, $Calibra^{(R)}$ and $Variolink^{(R)}$ II were divided into groups 4, 5, and 6, respectively. The investigation was carried out using disc-shaped specimens as specified by ANSI/ADA Specification No. 27. The degree of water sorption, water solubility and lactic acid solubility of each test group was analyzed statistically leading to the following conclusion. Results. The degree of water sorption was shown to increase in the following order : group 6, 5, 4, 2, 1 and 3. There were significant differences between the water sorption of each group. Results of the degree of water solubility were shown to increase in the following order : group 6, 5, 4, 2, 1 and 3. Statistically significant differences were found between each group, with the exception of groups 1 and 3. Finally, the degree of lactic acid solubility was found to increase in the following order : group 6,5,4,2,3 and 1. Significant differences were found between each group. In general dual-curing resin cements displayed substantially lower values than self-curing resin cements with regard to water sorption, water solubility, and lactic acid solubility. Conclusions. From the results of this study, dual-curing resin cements show a significantly lower degree of water sorption and solubility than their self-curing counterparts. Clinically, when selecting resin cements, the product with a lower degree of water sorption and solubility are preferred. The results of this study indicate that the use-of dual-curing resin cements is preferable to self-curing cements.

엽납석광석에 존재하는 Fe 불순물의 광물학적/화학적 특성과 마이크로웨이브 가열 및 자력분리에 의한 제거효과 (The Mineralogical and Chemical Characteristics of Fe Impurities and the Efficiency of their Removal Using Microwave Heating and Magnetic Separation in the Pyrophyllite Ore)

  • 조강희;김봉주;최낙철;박천영
    • 한국광물학회지
    • /
    • 제29권2호
    • /
    • pp.47-58
    • /
    • 2016
  • 엽납석광석에 Fe-성분이 불순물로 작용하여 엽납석의 최종 산업제품의 품위를 저하시키고 있다. 엽납석광석에 존재하는 불순물을 광물-화학적으로 확인하고 마이크로웨이브와 자력선별을 이용하여 Fe 함량을 건식방법으로 감소시키고자 하였다. 광학현미경, XRD, XRF, SEM/EDS 및 EPMA 분석을 통하여 엽납석에 황철석과 적철석이 포함되어 있는 것을 확인하였다. 엽납석에 포함된 자형의 황철석은 열수용액에 의하여 형성되고, 용해 공동 구조는 황철석이 산성수에 의하여 부분적으로 용해되어 형성되는 것으로 사료된다. 그리고 퇴적 기원 구조를 보이는 동심원 구조의 적철석은 산성수에 포함되어 있는 $Fe^{3+}$가 침전되어 형성된 것으로 사료된다. 마이크로웨이브 가열과 자력선별 실험을 수행한 결과 Fe 제거율은 성산광산이 96%, 완도광산이 93%로 나타났다. 마이크로웨이브 가열과 자력선별은 저 품위 엽납석을 품위 향상시킬 수 있는 친환경적 방법이라 사료된다.

타액에 오염된 상아질에 대한 콤포머의 접합양상 (THE ADHESIVE PATTERNS OF COMPOMER TO SALIVA-CONTAMINATED DENTIN)

  • 조영곤;김병태;이석종
    • Restorative Dentistry and Endodontics
    • /
    • 제25권4호
    • /
    • pp.575-586
    • /
    • 2000
  • In this study, adaptation of compomer to saliva contaminated dentin was evaluated with scanning electron microscope(SEM) and confocal laser scanning microscope(CLSM). For the SEM study, the occulusal surfaces of thirty two molar teeth were grounded to exposure dentin surfaces. The specimen were randomly assigned to control and three experimental groups with four samples in each group. In control group, Dyract and F-2000 compomer were bonded on the specimens according to the manufactures direction. Experimental groups were subdivided into three groups. They were contaminated with saliva on dentin surfaces ; Experimental group 1 : Saliva was dried with compressed air. Experimental group 2 : Saliva was rinsed with air-water spray and dried. Experimental group 3 : After polymerization of an adhesive, they were contaminated with saliva, and then saliva was rinsed with air-water spray and dried. Dyract and F-2000 compomer were bonded on saliva-treated dentin surfaces. The interfaces between dentin and compomer were observed with SEM. For the CLSM study, Class V cavities were prepared in buccal and ligual surfacess of thirty two molars. The specimens were divided into control and experimental groups. Class V cavities in experimental group were contaminated with saliva and those surfaces in each experimental groups received the same treatments as for the SEM study. Cavities were applied Prime & Bond 2.1 and F-2000 compomer primer/adhesive that were mixed with fluorescein, and then were filled with Dyract and F-2000 compomer. Specimens were embedded in transparent acrylic resin and sectioned buccolingual1y with diamond wheel saw, and then mounted on cover slide for CLSM study. The interface between cavity and compomer was observed by fluoresence imaging with a CLSM. The results were as follows : 1. In SEM exammination of Dyract group, control group, experimental group 2, 3 showed close adaptation to dentin and hybrid layer of $3{\sim}4{\mu}m$ diameter. Interfacial gap between compomer and dentin in experimental group 1 was wider than in control group. 2. In SEM examination of F-2000 group, adaptation to dentin of control group was closer than Dytact control group, but hybrid-like layer was not observed. Interfacial gap between compomer and dentin in experimental group 1 was wider than in Dyract experimental group 1. 3. In dissolution specimens of Dyract and F-2000 group, resin tags penetrated through dentinal tubules in control group and experimental group 1 and 3, but the penetration of resin tag was irregular and partial in experimental group 1. 4. In CLSM exammination of Dyract and F-2000 group, adhesive patterns of control and experimental groups showed same as in SEM. This result suggests the treatment methods, rinsing & drying, repeating all adhesive procedures, will produce good effect on adaptation of compomer to dentin if the dentin surface or polymerized adhesive is contaminated by saliva.

  • PDF

시클로덱스트린과의 포접에 의한 케토코나졸의 비점막 흡수증가 (Enhanced Nasal Absorption of Ketoconazole by Inclusion with Cyclodextrin)

  • 박기배;서보연;안홍직;노현구;온윤성;이광표
    • Journal of Pharmaceutical Investigation
    • /
    • 제24권2호
    • /
    • pp.95-104
    • /
    • 1994
  • Inclusion complexes of ketoconazole(KT) with ${\alpha}^_$, ${\beta}^_$cyclodextrin(CD) and $dimethy1-{\beta}-cyclodextrin$ (CD) and $dimethy1-{\beta}-cyclodextrin(DM{\beta}CD)$ as nasal absorption enhancer were prepared in 1: 2 molar ratios by freeze-drying and solvent evaporation methods. In order to compare with the intrinsic absorptivity of KT in the jejunum(J) and the nasal cavity(N), the in situ simultaneous perfusion method was employed. The in situ recirculation study revealed that KT-CD inclusion complexes with the greater stability constant and the faster dissolution rate proportionally increased the absorption of KT in the J and N of rats. The rank order of apparent KT permeability$(P_{app}\;:\;cm/sec\;{\time}\;1O^{-5}{\pm}S.E.)$, corrected by surface area of absorption, was $5.10{\pm}0.3(N,\; KT-DM{\beta}CD)$ )> $4.13{\pm}0.4(N,\;KT-{\beta}-CD)$ )> $3.52{\pm}0.2(N,\;KT-{\alpha}-CD)$ )> $2.76{\pm}0.3(J,\; KT-DM{\beta}CD)$ )> $2.61{\pm}0.5(J,\;KT-{\beta}-CD)$ )> $2.42{\pm}0.4(J,\;KT-{\alpha}-CD)$ at pH 4.0. The in crease in permeability of $KT-DM{\beta}CD$ inclusion complex was 2.6 folds in the J and 4.5 folds in the N when the perfusing solution was changed from the buffer(pH 4.0) to saline. The absorption rate of $KT-DM{\beta}CD$ inclusion complex after nasal administration was more rapid than those of ketoconazole alone and $KT-DM{\beta}CD$ inclusion complex after oral administration to rats. In comparision with an oral administration of ketoconazole suspension in corn oil, the relative bioavailability was calculated 137.3% for the oral and 195.0% for nasal $KT-DM{\beta}CD$ inclusion complex in rats. The present results suggest that $KT-DM{\beta}CD$ inclusion complex may serve as a potential nasal absorption enhancer for the nasal delivery of ketoconazole.

  • PDF

가시광선중합화에 따른 충전용 Glass Ionomer Cement의 물리적 성질에 관한 연구 (A STUDY ON THE PHYSICAL PROPERTIES OF GLASS IONOMER CEMENT FOR RESTORATIVE FILLING USING VISIBLE LIGHT POLYMERIZATION)

  • 신동훈;권혁춘
    • Restorative Dentistry and Endodontics
    • /
    • 제17권2호
    • /
    • pp.307-330
    • /
    • 1992
  • The aim of this study was to investigate the physical properties of visible light curing Glass Ionomer cement for restorative esthetic filling. The control group was the autopolymerizing GC Fuji II Glass Ionomer cement (2.2: 1 P/L ratio) and the experimental groups were made by following procedure. To induce the polymerization by visible light, the powder of GC Fuji II GI cement and the liquid of Vitrabond for base & liner were mixed in an amalgam capsule with 2.5:1, 3.0:1, 3.5:1 P/L ratio (% wt/wt). After fabrication of specimens, compressive strength, fracture toughness ($K_{IC}$) Scanning Electron Microscope and X-ray Diffraction, water-leachable content, marginal leakage and surface roughness were studied. The results were as follows: 1. Only experimental No. 1 group (visible light curing) showed less compressive strength than control group 1 hour after curing. Strength was increased with aging in all groups, so the compressive strength of light curing groups was no less than that of autopolymerizing group after 3 weeks. 2. Experimental No.3 group (visible light curing) was inferior to No.2 group (visible light curing) in fracture resistance but light curing groups were more resistant to fracture than autopolymerizing group and showed ductile fracture pattern as compared with the brittle fracture pattern of autopolymerizing group. 3. From scanning electron microscopic image, various sized unreacted powder particles, surrounded by silica gel, were embedded in polysalt matrix. Light curing groups showed little crack and more dense unreacted particles than autopolymerizing group. 4. From X-ray diffraction analysis, GC Fuji II Glass Ionomer cement powder and all groups showed glassy appearance but light curing groups seemed to be more intensive in crystaline than autopolymerizing group. S. The most significant dissolution was shown in early setting period in all group. Light curing groups were dissolved less than autopolymerizing group. 6. Marginal leakage was not different significantly in case of cavity margin composed of same tooth structure (ex. only enamel margin, only dentin margin) but much more leakage was shown in dentin/cementum margin than enamel margin. In only case of only enamel margin, light curing groups were superior to autopolymerizing group. 7. All groups showed relatively smooth surface, which irregularity was less than $1{\mu}m$. Light curing groups were smoother than autopolymerizing group.

  • PDF