• Title/Summary/Keyword: disposable

Search Result 426, Processing Time 0.027 seconds

Changes in Subjective/Objective Symptoms and the Light Transmissibility of Lens Associated with Overusage of Daily Disposable Circle Contact Lenses in Normal Eyes (일회용 써클소프트렌즈의 초과 착용에 의한 정상안의 자·타각적 증상 및 렌즈 광투과율의 변화)

  • Park, Mijung;Kwon, Hae Lim;Choi, Sae Ah;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.4
    • /
    • pp.429-439
    • /
    • 2013
  • Purpose: This study was assessed to investigate the change of subjective and/or objective symptoms and the light transmissibility of lens caused by over-usage of daily disposable circle contact lenses (circle lens). Methods: Three daily disposable circle lenses made of etafilcon A, hilafilcon B, and nelfilcon A were applied on 20 normal eyes free from any eye diseases by when subjects complained any kind of discomfort. On the first and the last days of lens wearing, subjective discomfort, blinking rate, non-invasive break-up time, lens centration on corneal surface and visible light transmissibility of lens were recorded at every case and compared. Results: The circle lens wearers complained discomfort when they wore the circle lens more than 15 hours, in excess of 8 hours being the recommended wearing time and the most circle lens wearers quit the lens wearing when they wore more than 30 hours. On the last day of lens wearing, the representative subjective discomforts were stiffness, dryness and tiredness. When the subjects wore circle lens more than the recommended time, a tendency of increased blinking rate and decreased NIBUT was observed when it compared with the values right after lens wearing. On the last day of lens wearing, the lens centration was shown to be decentrated from the pupil center compared with the centration right after the wearing. These changes in lens centration and blinking rate were consistently shown in all cases of lens wearing however, the difference in the degree of subjective and/or objective change was present depending on lens materials and subjects. The visible light transmissibility of circle lens has largely been changed. Conclusions: From these results, it was thought that the decreased NIBUT induced dryness and stiffness and decreased visible light transmissibility caused more blinking when daily disposable circle lens was exceedingly used, which provoked lens decentration and subjective discomfort. However, the difference of subjective and/or objective change was largely varied in accordance with the lens material types and individuality and thus it may occur some unexpected problems by the individual base. Therefore, the education about the necessity to comply with the recommended wearing time and the problem will be essential.

A Survey for Changed Control Policies of Hepatitis B in Republic of Korea (우리나라의 B형 간염 조절 정책의 변화에 대한 조사)

  • Han, Ji Yoon;Jung, Tae Woong;Koh, Dae Kyun;Kim, Jong Hyun
    • Pediatric Infection and Vaccine
    • /
    • v.18 no.2
    • /
    • pp.124-134
    • /
    • 2011
  • Purpose : We have tried to search all concerning data on the policies of hepatitis B vaccination or surveillance of medical equipments that can transmit blood mediated diseases, including disposable syringe, in Republic of Korea, to propose references to other medical professionals. Methods : Data from domestic journals, government websites, computerized newspapers, etc. were reviewed. The data were arranged into four categories (governmental policies on hepatitis B control, hepatitis B mass immunization program in school, using process of hepatitis B vaccine, and policies on medical equipments surveillance, including disposable syringes, which is considered as source of blood mediated infection), and the periodic changes on each subjects in policies were reviewed. Results : Due to growing social concerns on hepatitis B in early 1980s, swift introduction and production of hepatitis B vaccine was made. After establishment of "5 year project for eradication of hepatitis B" in late 1983, number of vaccinated population jumped up to 6 million within 2 years (1984-85). However, since the immunization targets were mainly adult, not infant, this project was annulled in late 1985. Following this project, hepatitis B mass immunization program in school was carried out. In year 1995, hepatitis B vaccine was included in national immunization program. The use of disposable syringe was recommended from year 1980 but legislated in year 1985, finally. Conclusion : The mainstay in controlling hepatitis B in Republic of Korea was coordination of prompt introduction of vaccine, mass immunization, high vaccination coverage rate, or use of disposable syringes. However, since there is lack of official data available, it is urgent to arrange and computerize all government data related to infectious diseases.

Disposable Power Generator with Tubular PEMFC and H2 Generator for the Power Source of Microfluidic Devices (튜브형 고분자전해질 연료전지와 일회용 수소발생소자를 결합한 미세유체소자용 전원공급소자)

  • Kim, Kwang-Ho;Seo, Young-Ho;Kim, Byeong-Hee
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.7
    • /
    • pp.829-835
    • /
    • 2010
  • This paper presents a disposable power generator for microfluidic devices; the power generator has a tubular PEMFC and a $H_2$ generator. The tubular PEMFC has a tubular MEA (diameter: 1.52 mm) that is supported by a spiral wire electrode. The $H_2$ generator supplied $H_2$ to the tubular PEMFC; $H_2$ was generated via the reaction of Al foil (27 mg) and 5 M NaOH (0.12 ml). The open circuit voltage and power density of a unit cell of the tubular PEMFC were 0.81 V and $16.4\;mW/cm^2$ (0.35 V), respectively. The $H_2$ generator generated 11.6 ml $H_2$ for 15min. The power generator was continuously operated for 15 min at 0.64 mW (0.71 V) and for 10 min at 1.06 mW (0.46 V). We experimentally verified that it is feasible to use the proposed power generator as a power source for microfluidic devices; in the experiment, an LED (2.5 mW; 1.8 V) was lit for 10 min by using three serially connected TPEMFCs and one $H_2$ generator.

Investigation about the Actual Prevention of Infection and Vaccination against B-type Hepatitis among Dental Workers in Daegu (대구지역 치과 의료기관 종사자의 B형간염 예방접종 및 감염관리 실태)

  • Eun, Jeong-Hwa;Bae, Ji-Young
    • Journal of Korean society of Dental Hygiene
    • /
    • v.5 no.2
    • /
    • pp.219-233
    • /
    • 2005
  • This study was conducted on 185 workers at 73 dental clinics and university hospitals in Daegu to investigate the actual prevention of infection and vaccination against B-type hepatitis among dental workers. 1. According to the result of medical examination, only 35 out of 144 (24%) dental clinic workers had periodic health examination while 7 out of 9 (78%) university hospital workers did. 2. In a survey on vaccination against B-type hepatitis, 52 workers aged 29 or younger (96.3%), 38 dental hygienists (51.9%) and 44 dental workers at dental clinics (81.5%) have not had any vaccination against B-type hepatitis. The rest appeared to have had vaccination or be aware that they had antibody against B-type hepatitis without having to have any vaccination. 3. According to the result of a survey on the existence of antibody by job, 42 (56%) of dental hygienists, 15 (20%) of assistant nurses, 12 (16%) of medical assistants and 6 (8%) of dental technicians did not know whether or not they had antibody. This suggests that all types of dental workers except dental hygienists have low awareness of whether or not they have antibody. 4. In a survey on the relation between general characteristics of subjects and the sterilization of dental equipment, alcohol disinfection of high speed handpiece and low speed handpiece was most common among dental workers aged 29 or younger, and all of those aged over 40 used autoclave. By position, alcohol disinfection was used most commonly for high-speed handpiece. antiseptic solution deposition for disposable suction lips, and autoclaving for impression. By workplace, dental workers at university hospitals used autoc1aving most frequently for high/low speed handpiece while those at dental hospitals and dental clinics used alcohol disinfection most frequently and even some respondents replied that they did not disinfect. For metal cups, workers at dental clinics and dental hospitals did not use any sterilizing method while those at university hospitals used autoclaving. For disposable suction tips, workers at dental clinics used antiseptic solution deposition and those at dental hospitals used alcohol disinfection but some respondents replied that they did not disinfect. For metal suctions and impression trays, autoclaving was most common in all workplaces but some dental clinics replied that they did not disinfect impression trays. According to work experience, alcohol disinfection was most common for high/low speed handpiece. For disposable suction tips, dental workers with 3 years' or shorter work experience, those with 3~6 years' experience and those with 9~12 years' experience used antiseptic solution deposition most commonly, and many of those with 6~9 years replied that they did not disinfect. The results of this study stated above suggest that systematic education is necessary for all dental workers for enhancing th eir awareness of B-type hepatitis and the prevention of infection. Moreover, dental workers are required to make efforts to prevent infection with B-type hepatitis voluntarily and actively.

  • PDF

Development of Disposable Immunosensors for Rapid Determination of Sildenafil and Vardenafil in Functional Foods

  • Vijayaraj, Kathiresan;Lee, Jun Hyuck;Kim, Hyung Sik;Chang, Seung-Cheol
    • Journal of Food Hygiene and Safety
    • /
    • v.32 no.2
    • /
    • pp.83-88
    • /
    • 2017
  • We introduced disposable amperometric immunosensors for the detection of Sildenafil and Vardenafil (SDF/VDF) based on screen printed carbon electrodes. The developed immunosensors were used as a non-competitive sandwich-type enzyme immunoassay with a horseradish peroxidase label. The sensors were constructed on screen printed carbon electrodes by the simple electrochemical deposition of a reduced graphene oxide and chitosan (ErGO-CS) composite. To evaluate the sensing chemistry and optimize the sensor characteristics, a series of electrochemical experiments were carried out including electrochemical impedance spectroscopy, cyclic voltammetry and amperometry. The sensors showed a linear response to SDF/VDF concentrations in a range from 100 pg/mL to 300 ng/mL. The lower detection limit was calculated to be 55 pg/mL, the sensitivity was calculated to be $1.02{\mu}Ang/mL/cm^2$, and the sensor performance exhibited good reproducibility with a relative standard deviation (RSD) of 7.1%. The proposed sensing chemistry strategy and the sensor format can be used as a simple, cost-effective, and feasible method for the in-field analysis of SDF/VDF in functional or health supplement food samples.

Effect of Chronic Toxicity by Waste Microplastics (PET) on Daphnia magna (폐 미세플라스틱(PET)의 물벼룩 만성독성 연구)

  • Han, Bomi;Park, GeonU;Yoo, Seungwoo;Kim, Changhae;Jung, Jinho;Na, Joorim
    • Ecology and Resilient Infrastructure
    • /
    • v.8 no.4
    • /
    • pp.281-289
    • /
    • 2021
  • Commercially used disposable cups undergo fragmentation in the environment and become microplastics (MPs). These MPs can be ingested by aquatic organisms and cause a range of adverse effects. We assessed the acute and chronic toxicity of disposable cup-derived MP fragments in Daphnia magna. MP fragments were identified as a polyethylene terephthalate (PET) fragment with a size of 33.18 ± 7.76 ㎛. The presence of three additives including 1- Propanone. 1-phenyl-3-[2-(phenylmethoxy)phenyl]-, p-Xylene and ethylbenzene was analyzed from MP fragments. The 48 h acute toxicity revealed that 20 % of immobilization and mortality were found at the highest concentration of PET MP (200 mg L-1). The 21 d chronic toxicity revealed that PET MP fragments significantly (p < 0.05) more reduced survival rate (31 %), total offspring (52 %) in D. magna compared with control group. The developmental abnormality of offspring (3.5%) by PET MP fragments was significantly (p < 0.05) higher than control groups (0.3%). These results are possibly induced by gut blocking by ingestion of MP fragments and their longer retention time. These findings indicate that the fragmentation of disposable cups (PET polymers) into small-sized MP fragments pose a significant ecological risk to aquatic organisms. Further studies are required to elucidate the underlying toxicity mechanisms.

Comparison of Bacterial Removal Effectiveness by Different Hand Washing Methods (손세정 방법에 따른 세균 제거 효과 비교에 대한 융복합 연구)

  • Chong, Moo-Sang;Lee, Jang-Jin;Kim, Jiro
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.9
    • /
    • pp.69-74
    • /
    • 2019
  • The purpose of this study is to compare the efficiency of bacteria removal of three different types of hand washing methods. This study performed a convenient sampling of 30 volunteers in cross-over design. The study divided the 30 volunteers into three random groups. The three groups were asked to use antiseptic soap, alcohol-based hand disinfectant, and disposable wet wipes respectively. The result of the study showed that mean log reduction values after each had washing method were $-0.45({\pm}0.69)$ with antiseptic soap and water, $-1.19({\pm}0.52)$ with alcohol-based hand disinfectant and $-0.75({\pm}0.58)$ with disposable wet wipes. The difference was statistically significant when using alcohol-based hand disinfectant compared to the other two methods (p=0.000). According to this study, alcohol-based hand disinfectant was the most effective product based on bacteria removal for hand washing. Advantages of using alcohol-based hand disinfectant are that it is cost-effective and easy to buy, also eco-friendly. Therefore, to prevent infectious disease, providing alcohol-based hand disinfectant to every corner of the community will be very helpful.

Use of Menstrual Sanitary Products in Community Women of Childbearing Age (지역사회 가임기 여성의 생리대 사용 조사)

  • Hyunju Dan;Heeja Jung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.6
    • /
    • pp.401-407
    • /
    • 2023
  • This study is a descriptive study to identify the patterns of use of menstrual sanitary products among community women of childbearing age. The participants were 1,571 women between the ages of 19 and 40, and data collection was conducted through online and mobile surveys from September 2020 to August 2021. As a result, 88.9% of the participants were using disposable menstrual pad, 5.6% tampons, 3.1% cloth menstrual pad, and followed by others(2.4%), including menstrual cups. The differences of type of menstrual sanitary products according to general characteristics showed significant in age(p=.006), marital status(p=.005), education level(p=.002), annual salary(p=.018), experience of pregnancy(p=.036), and menstrual regularity(p=.022). More than half of the participants(53.8%) responded that cloth menstrual pads were 'very safe' or 'safe,' but 27.9% and 20.1% of disposable menstrual pads and tampons, respectively. The difference in menstrual distress according to the type of menstrual sanitary products showed that tampon users had a higher menstrual discomfort score for the most recent menstruation(F=4.092, p=.017) and 4 days before menstruation(F=4.178, p=.016) than users of disposable menstrual pad or cloth menstrual pad. Therefore, it is necessary to continuously investigate the use of menstrual sanitary products by women of childbearing age and its relationship with reproductive health.

Electrochemical Characteristics of Pencil Graphite Electrode Through Surface Modification and its Application of Non-enzymatic Glucose Sensor (표면 개질된 샤프심 전극의 전기화학적 특성 고찰 및 비효소적 글루코스 센서 활용)

  • Min-Jung Song
    • Korean Chemical Engineering Research
    • /
    • v.62 no.2
    • /
    • pp.147-152
    • /
    • 2024
  • Most medical sensors are disposable products. In order to reduce inspection and diagnosis costs, it is more important to develop the inexpensive electrode materials. We fabricated the CuO NPs/PANI/E-PGE as an electrode material for disposable electrochemical sensors and applied it to a non-enzymatic glucose sensor. For surface activation of PGE, pretreatment was performed using chemical and electrochemical methods, respectively. Electrochemical properties according to the pretreatment method were analyzed through chronoamperometry (CA), cyclic voltammetry (CV) and electrochemical impedance (EIS). From these analytical results, the electrochemically pretreated PGE (E-PGE) was finally adopted. The non-enzymatic glucose sensor based on CuO NPs/PANI/E-PGE shows sensitivity of 239.18 mA/mM×cm2 (in a linear range of 0.282~2.112 mM) and 36.99 mA/mM×cm2 (3.75423~50 mM), detection limit of 17.6 μM and good selectivity. Based on the results of this study, it was confirmed that the modified PGE is a high-performance electrode material. Therefore, these electrodes can be applied to a variety of disposable sensors.