Subservient Bone Reduction with Histoacryl$^{(R)}$ (N-butyl-2-cyanoacrylate) in Hand Fractures: Two Cases of Report (수부 골절 시 Histoacryl$^{(R)}$ (N-butyl-2-cyanoacrylate)을 이용한 보조적 골 정복 2례)

  • Lee, Won;Lee, Sung-Hwan;Oh, Sang-A;Kang, Dong-Hee
    • Archives of Plastic Surgery
    • /
    • v.38 no.1
    • /
    • pp.102-104
    • /
    • 2011
  • Purpose: The standard treatments of hand fractures today are fixations by K -wires, metal plates, wires and lag screws. But it is very difficult to reconstruct fractures by placing implants into small bony fragments especially in the comminuted fractures and intra-articular fractures. This paper describes a simple method of reconstruction with Histoacryl$^{(R)}$ for comminuted and intra-articular fractures in hands. Methods: 2 cases with comminuted and intra-articular fractures by crushing injury were reconstructed with Histoacryl$^{(R)}$. We performed applying Histoacryl$^{(R)}$ with swab on the bone cortex carefully to avoid Histoacryl$^{(R)}$ infiltrating into the medulla. We could rearrange and fixate bony fragments using only Histoacryl$^{(R)}$, in addition, metal plates, K-wires, wires, and lag screws could be used for secondary fixation if needed. Results: Post-operative X-ray finding of 2 patients assured that the bony fragments of the hand fractures maintained their original positions. Significant displacement and deviation, infection, nonunion, and malunion during the follow-up period were not observed. Conclusion: This study showed the possibility of using Histoacryl$^{(R)}$ in addition as a simple method of fixation in the comminuted and intra-articular hand fractures.

Short-term Results of the Total Ankle Arthroplasty with $HINTEGRA^{(R)}$ Total Ankle Prosthesis ($HINTEGRA^{(R)}$ 족관절 치환물을 이용한 족관절 전치환술의 단기 추시 결과)

  • Jung, Hong-Geun;Bae, Eui-Jung;Park, Jae-Yong;Kim, Tae-Hoon
    • Journal of Korean Foot and Ankle Society
    • /
    • v.13 no.1
    • /
    • pp.40-45
    • /
    • 2009
  • Purpose: End-stage ankle arthritis is frequently combined with ankle-hindfoot deformity or ankle instability and therefore additional surgical procedures are often required when performing total ankle arthroplasty. We report the short term clinical and radiographic results of the total ankle arthroplasty with/without the combined adjunctive surgical procedures. Materials and Methods: The study is based on the 17 ankles (16 patients) of end-stage ankle arthritis that were treated with $HINTEGRA^{(R)}$ Total ankle prosthesis (Newdeal, Lyons, France) total ankle arthroplasty (TAA) from 2004 to 2007 with at least 12 months follow-up. The combined adjunctive procedures as well as the VAS pain score, AOFAS score, radiographic measurements and patient satisfactions were evaluated. Results: Average follow-up period was 29 months (13${\sim}$55 months), and the age was average 62 years (39${\sim}$75 years) old. Among total of 17 ankles, varus deformity and lateral ankle instability were found in 4 cases and 3 cases respectively. Twenty additional procedures such as Achilles triple hemisection (9), calcaneal displacement osteotomy (4) and lateral ankle ligament reconstruction (3) were performed in adjunct to TAA in 13 ankles. VAS pain score improved from preoperative average 8.4 (7${\sim}$10) to 2.0 (0${\sim}$5) and the AOFAS functional score improved from 41.8 points (13${\sim}$71 points) to 90.6 (77${\sim}$100 points) at final follow-up. Ninety-four percent of the patients were satisfied with the surgery. Conclusion: We confirmed that many adjunctive combined surgical procedures are often necessary in addressing the end-stage ankle arthritis (74%) with total ankle arthroplasty. We also achieved quite good clinical and radiographic short term results, although the long term follow-up study with larger number of cases are needed in the future.

  • PDF

Surgical treatment of the Acute Acromioclavicular Dislocation (견봉 쇄골 관절의 급성 완전탈구에 대한 수술적 치료)

  • Lee Kwang-Won;Hwang In-Sik;Choy Won-Sik
    • Clinics in Shoulder and Elbow
    • /
    • v.1 no.2
    • /
    • pp.175-179
    • /
    • 1998
  • The acromioclavicular joint is commonly affected by traumatic and degenerative conditions. Most injuries are due to direct trauma, such as a fall on the shoulder. Although there is general agreement on treatment of type I, Ⅱ, Ⅳ, V and VI acromioclavicular injuries, the treatment of type Ⅲ injuries remains controversial. Sixty patients, ranging in age from 19 to 57 years(average, 32), were evaluated an average of 57.5 (range, 13 to 96) months after surgical reconstruction for Rockwood type Ⅲ Ⅳ, V acromioclavicular dislocation. Phemister method (47 cases), Bosworth (3 cases), Weaver and Dunn method (10 cases) were used to correct displacement. An increase of the coracoclavicular distance of the injured shoulder over the normal shoulder was average 7.1㎜ at initial, average l㎜ on postoperatively, and average 2㎜ at follow-up. Overall, 54 of 60(90%) patients achieved satisfactory results. Degree of increase of the coracoclavicular distance has no inliluence to clinical results.

  • PDF

An Experimental Study on Precast Bridge Piers Confined by FRP for Technical Development of Accelerated Construction (급속시공기술 개발을 위한 FRP로 보강된 프리캐스트 교각의 실험 연구)

  • Lee, Seung-Hye;Lee, Yeong-Ho;Hwang, Yoon-Koog;Song, Jae-Joon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.237-240
    • /
    • 2008
  • Today, some bridges or highways are becoming superannuated in Korea. Also, in this section, rehabilitation, replacement and expansion are necessary to increasing traffic volumes these days. Bridge reconstruction is major problem because it has relation to civil application, economical loss and loss of vehicles made a detour while this work. Many precast components and methods of construction are developed for this issue. Many research of various precast components and new materials are being performed owing to apply to prefabrication bridges. The present paper represents experimental studies on the performance of precast CFFT pier model. Also, stay-in-place RC pier and stay-in-place CFFT pier are made an experiment on due to comparing test results. Hysteretic responses of all columns are obtained through the test. Compared with the displacement ductility factors, conclusions of seismic performances can be made.

  • PDF

Socket preservation using eggshell-derived nanohydroxyapatite with platelet-rich fibrin as a barrier membrane: a new technique

  • Kattimani, Vivekanand Sabanna;Lingamaneni, Krishna Prasad;Kreedapathi, Girija Easwaradas;Kattappagari, Kiran Kumar
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.45 no.6
    • /
    • pp.332-342
    • /
    • 2019
  • Objectives: Socket grafting is vital to prevent bone resorption after tooth extraction. Several techniques to prevent resorption have been described, and various bone graft substitutes have been developed and used with varying success. We conducted this pilot study to evaluate the performance of nanohydroxyapatite (nHA) derived from chicken eggshells in socket preservation. Materials and Methods: This was a prospective, single center, outcome assessor-blinded evaluation of 23 sockets (11 patients) grafted with nHA and covered with platelet-rich fibrin (PRF) membrane as a barrier. Bone width and radiographic bone density were measured using digital radiographs at 1, 12, and 24 weeks post-procedure. Postoperative histomorphometric and micro-computed tomography (CT) evaluation were performed. The study protocol was approved by the Institutional Ethics Committee. Results: All patients had uneventful wound healing without graft material displacement or leaching despite partial exposure of the grafted socket. Tissue re-epithelialized with thick gingival biotype (>3 mm). Width of the bone was maintained and radiographic density increased significantly with a trabecular pattern (73.91% of sockets) within 12 weeks. Histomorphometric analysis showed 56.52% Grade 3 bone formation and micro-CT analysis revealed newly formed bone with interconnecting trabeculae. Conclusion: Use of a PRF membrane with nHA resulted in good bone regeneration in sockets. Use of a PRF membrane prevents periosteal-releasing incisions for primary closure, thereby facilitating the preservation of keratinized mucosa and gingival architecture. This technique, which uses eggshell-derived nHA and PRF membrane from the patient's own blood, is innovative and is free of disease transfer risks. nHA is a promising economic bone graft substitute for bone regeneration and reconstruction because of the abundant availability of eggshell waste as a raw material.

The Reliability of the Transconjunctival Approach for Orbital Exposure: Measurement of Positional Changes in the Lower Eyelid

  • Yoon, Sung Ho;Lee, Jin Hoon
    • Archives of Craniofacial Surgery
    • /
    • v.18 no.4
    • /
    • pp.249-254
    • /
    • 2017
  • Background: Lower eyelid incisions are widely used for the orbital approach in periorbital trauma and aesthetic surgery. In general, the subciliary approach is known to cause disposition of the lower eyelid by scarring the anterior lamella in some cases. On the other hand, many surgeons believe that a transconjunctival approach usually does not result in such complications and is a reliable method. We measured positional changes in the lower eyelid in blowout fracture repair since entropion is one of the most serious complications of the transconjunctival orbital approach. Methods: To measure the positional changes in the lower eyelids, we analyzed preoperative and postoperative photographs over various time intervals. In the analysis of the photographs, marginal reflex distance 2 ($MRD_2$) and eyelash angle were used as an index of eyelid position. Statistical analyses were performed to identify the significance in the positional changes. All patients underwent orbital reconstruction through a transconjunctival incision by a single plastic surgeon. Results: In 42 blowout fracture patients, there was no statistical significant difference in the MRD2 and eyelash angle. Furthermore, there were no clinical complications, such as infection, hematoma, bleeding, or implant protrusion, during the follow-up periods. Conclusion: The advantages of the transconjunctival approach for orbital access include minimal scarring and a lower risk of eyelid displacement compared with other approaches. Based on these results, we recommend the transconjunctival approach for orbital exposure as a safe and reliable method.

Clinical and Radiological Outcomes of Acute Acromioclavicular Joint Dislocation: Comparison of Hook Plate Fixation with Single Tight Rope Technique

  • Lee, Sung Hyun;Kim, Jeong Woo;Kook, Seng Hwan
    • Clinics in Shoulder and Elbow
    • /
    • v.20 no.3
    • /
    • pp.153-161
    • /
    • 2017
  • Background: This study was conducted to compare the clinical and radiological outcomes of the locking hook plate fixation (HP) technique and the single tight rope (TR) technique applied for acute high-grade acromioclavicular (AC) joint separations. Methods: Between 2009 and 2014, 135 consecutive patients with acute AC joint separation Rockwood types III, IV, and V were subjected to surgical reconstruction. One hundred fourteen patients (84.4%) were available for retrospective evaluation. Of them, 62 and 52 were treated using the single TR group and clavicular HP group techniques, respectively. The visual analogue scale, Constant, American Shoulder and Elbow Surgeons (ASES), and Taft scores were used for clinical assessment. Postoperative shoulder range of motion was also assessed. An anteroposterior radiograph of the coracoclavicular distance (CCD) was obtained to evaluate the radiographic signs of recurrence. Results: The TR group patients had better Constant, ASES, and Taft scores than the HP group patients. The loss of reduction in terms of the CCD did not differ between groups. Subacromial osteolysis was observed in 34.6% of the cases in the HP group. However, there were no significant differences in the clinical outcomes between the patients with and without osteolysis in the HP group. Subcoracoid osteolysis, drill tunnel widening, and metal displacement were observed in 3.2%, 22.6%, and 4.8% of the cases in the TR group, respectively. Conclusions: The single TR technique was relatively more effective at treating acute high-grade AC joint injuries than the HP fixation technique (level of evidence: therapeutic; retrospective comparative study, Level III).

Frontotemporal Craniotomy for Clipping of Unruptured Aneurysm Using a Diamond-Coated Thread Wire Saw and Reconstruction Using Calcium Phosphate Cement without Metal Fixation

  • Hiroyuki Koizumi;Daisuke Yamamoto;Hajime Handa;Wakiko Saruta;Satoru Shimizu;Takuichiro Hide;Toshihiro Kumabe
    • Archives of Plastic Surgery
    • /
    • v.50 no.3
    • /
    • pp.248-253
    • /
    • 2023
  • Metal fixation systems for cranial bone flaps cut by a drill are convenient devices for cranioplasty, but cause several complications. We use modified craniotomy using a fine diamond-coated threadwire saw (diamond T-saw) to reduce the bone defect, and osteoplasty calcium phosphate cement without metal fixation. We report our outcomes and tips of this method. A total of 78 consecutive patients underwent elective frontotemporal craniotomy for clipping of unruptured intracranial aneurysms between 2015 and 2019. The follow-up periods ranged from 13 to 66 months. The bone fixation state was evaluated by bone computed tomography (CT) and three-dimensional CT (3D-CT). The diamond T-saw could minimize the bone defect. Only one wound infection occurred within 1 week postoperatively, and no late infection. No pain, palpable/cosmetically noticeable displacement of the bone flap, fluid accumulations, or other complications were observed. The condition of bone fixation and the cosmetic efficacy were thoroughly satisfactory for all patients, and bone CT and 3D-CT demonstrated that good bone fusion. No complication typical of metal fixation occurred. Our method is technically easy and safety, and achieved good mid-term bone flap fixation in the mid-term course, so has potential for bone fixation without the use of metal plates.

The Benefit of KT-2000 Knee Ligament Arthrometer in Diagnosis of Anterior Cruciate Ligament Injury (슬관절 전방 십자 인대 파열의 진단에 있어서 KT-2000 기기의 유용성)

  • Park, Jai-Hyung;Kim, Hyoung-Soo;Jung, Kwang-Gyu;Yoo, Jeong-Hyun
    • Journal of the Korean Arthroscopy Society
    • /
    • v.8 no.2
    • /
    • pp.82-88
    • /
    • 2004
  • Purpose: In this study, we intended to ascertain the benefit of KT-2000 Knee arthrometer(KT-2000) in the diagnosis of ACL(Anterior cruciate ligament) injury by comparing the anterior displacement of normal knee with that of ACL deficient knee. Materials and Methods: We designated two examiners to measure the anterior displacement of the knee joint of 30 healthy individuals, using KT-2000, at 30$^{\circ}$ flexion setting of muscle full relaxation, contraction, 25$^{\circ}$ internal rotation and 25$^{\circ}$ external rotation and analyzed these results according to the variables and measured the preoperative anterior displacement of the ACL injured knee in the 30 patients who have gone through an arthroscopic ACL reconstruction later. Results: The results of examiner 1 are 6.5${\pm}$1.5 mm, 2.5${\pm}$0.9 mm, 4.8${\pm}$1.2 mm, 6.4${\pm}$1.3 mm in right knee and 5.6${\pm}$1.3 mm, 2.1${\pm}$0.8 mm, 4.5${\pm}$1.2 mm, 5.2${\pm}$1.3 mm in left knee, in order of muscle full relaxation, contraction, 25$^{\circ}$ internal rotation and 25$^{\circ}$ external rotation. The results of examiner 2 are 6.9${\pm}$1.2mm, 2.9${\pm}$1.1mm, 5.6${\pm}$1.6mm, 6.9${\pm}$1.5mm in right, 5.5${\pm}$1.7 mm,1.9${\pm}$0.9 mm, 5.1${\pm}$1.9 mm, 5.7${\pm}$1.6 mm in left knee, The side to side difference of examiner 1 in the setting of muscle relaxation is 0.9${\pm}$1.0 mm. The anterior displaement of ACL injured knee is average 11${\pm}$2.93 mm and difference of average 6.5${\pm}$2.31 mm form that of normal. In comparison between the right and left knees of healthy individuals, the both results of two examiners showed the statistical difference in the setting of muscle full relaxation but, the results showed the side to side difference below 2 mm in 25case(83%), 21case(70%) respectively and above 3 mm in just 1 case. In the comparison between the normal and ACL injured knees, the results show the statistical difference of the side to side difference in the setting of muscle relaxation(p<0.05). Conclusion: The KT-2000 result is affected by relaxation of muscles around knee, flexion angle of knee joint, rotation of tibia, the strength of displacing force, time of the test and physical factors as height and weight. However, the Accuracy of diagnosis of ACL injury by KT-2000 will increase if the examiner is skillful and the tests are made on the exact position of knee joint.

  • PDF

Quantitative Analysis of the Orbital Volume Change in Isolated Zygoma Fracture (관골 단독 골절에서 안구 용적 변화의 정량적 분석)

  • Jung, Han-Ju;Kang, Seok-Joo;Kim, Jin-Woo;Kim, Young-Hwan;Sun, Hook
    • Archives of Plastic Surgery
    • /
    • v.38 no.6
    • /
    • pp.783-790
    • /
    • 2011
  • Purpose: The zygoma (Zygomaticomaxillary) complexes make up a large portion of the orbital floor and lateral orbital walls. Zygoma fracture frequently causes the posteromedial displacement of bone fragments, and the collapse or overlapping of internal orbital walls. This process consequently can lead to the orbital volume change. The reduction of zygoma in an anterolateral direction may influence on the potential bone defect area of the internal orbital walls. Thus we performed the quantitative analysis of orbital volume change in zygoma fracture before and after operation. Methods: We conducted a retrospective study of preoperative and postoperative three-dimensional computed tomography scans in 39 patients with zygoma fractures who had not carried out orbital wall reconstruction. Orbital volume measurement was obtained through Aquarius Ver. 4.3.6 program and we compared the orbital volume change of injured orbit with that of the normal contralateral orbit. Results: The average orbital volume of normal orbit was 19.68 $cm^3$. Before the operation, the average orbital volume of injured orbit was 18.42 $cm^3$. The difference of the orbital volume between the injured orbit and the normal orbit was 1.18 $cm^3$ (6.01%) on average. After operation, the average orbital volume of injured orbit was 20.81 $cm^3$. The difference of the orbital volume between the injured orbit and the normal orbit was 1.17 $cm^3$ (5.92%) on average. Conclusion: There are considerable volume changes in zygoma fracture which did not accompany internal orbital wall fracture before and after operation. Our study reflects the change of bony frame, also that of all parts of the orbital wall, in addition to the bony defect area of orbital floor, in an isolated zygoma fracture so that it evaluates orbital volume change more accurately. Thus, the measurement of orbital volume in isolated zygoma fractures helps predict the degree of enophthalmos and decide a surgical plan.