References
- Smith SC, Pelofsky S. Adaptation of rigid fixation to cranial flap replacement. Neurosurgery 1991;29(03):417-418 https://doi.org/10.1227/00006123-199109000-00013
- Berryhill WE, Rimell FL, Ness J, Marentette L, Haines SJ. Fate of rigid fixation in pediatric craniofacial surgery. Otolaryngol Head Neck Surg 1999;121(03):269-273 https://doi.org/10.1016/S0194-5998(99)70183-X
- Gupta R, Adeeb N, Griessenauer CJ, et al. Removal of symptomatic titanium fixation plates after craniotomy. Acta Neurochir (Wien) 2016;158(10):1845-1848 https://doi.org/10.1007/s00701-016-2929-7
- Yamada SM, Gorai K, Gonda K. Pinwheel-shaped titanium plates should be fixed to the skull using all screw holes to protect the plates from being bent. Case Rep Surg 2019;2019;5709285
- Wakui D, Nagashima G, Ueda T, Takada T, Tanaka Y, Hashimoto T. Three cases of scalp rupture and cosmetic deformity caused by a fixation plate after craniotomy. . [in Japanese]Jpn J Neurosurg 2012;21(02):138-142 https://doi.org/10.7887/jcns.21.138
- Noda K, Tanikawa R, Sugimura T, et al. Use of bioabsorbable plates for cranial fixation. Neurol Med Chir (Tokyo) 2009;49(11):559-562 https://doi.org/10.2176/nmc.49.559
- Wu CM, Chen YA, Liao HT, Chen CH, Pan CH, Chen CT. Surgical treatment of isolated zygomatic fracture: outcome comparison between titanium plate and bioabsorbable plate. Asian J Surg 2018;41(04):370-376 https://doi.org/10.1016/j.asjsur.2017.03.003
- Shimizu S, Kondo K, Yamazaki T, Nakayama K, Yamamoto I, Fujii K. Repositioning of cranial bone flaps cut with a diamond-coated threadwire saw: 5-year experience with cosmetic cranioplasty without fixation devices. Skull Base 2011;21(05):323-328 https://doi.org/10.1055/s-0031-1284214
- Shimizu S, Miyazaki T, Suzuki S, et al. Supratentorial craniotomy using a threadwire saw. Technical note. Neurol Med Chir (Tokyo) 2008;48(04):191-194, discussion 194 https://doi.org/10.2176/nmc.48.191
- Hohne J, Werzmirzowsky K, Ott C, et al. Outcomes of cranioplasty with preformed titanium versus freehand molded polymethylmethacrylate implants. J Neurol Surg A Cent Eur Neurosurg 2018;79(03):200-205 https://doi.org/10.1055/s-0037-1604362
- Novakovic N, Malivukovic A, Minic L, Lepic M, Mandic-Rajcevic S, Rasulic L Cranial reconstruction using autologous bone and methylmethacrilate. J Craniofac Surg 2017;28(04):877-881 https://doi.org/10.1097/SCS.0000000000003499
- Blum KS, Schneider SJ, Rosenthal AD. Methyl methacrylate cranioplasty in children: long-term results. Pediatr Neurosurg 1997;26(01):33-35 https://doi.org/10.1159/000121158
- Matsuno A, Tanaka H, Iwamuro H, et al. Analyses of the factors influencing bone graft infection after delayed cranioplasty. Acta Neurochir (Wien) 2006;148(05):535-540, discussion 540 https://doi.org/10.1007/s00701-006-0740-6
- Gautschi OP, Schlett CL, Fournier JY, Cadosch D. Laboratory confirmed polymethyl-methacrylate (Palacos)-hypersensitivity after cranioplasty. Clin Neurol Neurosurg 2010;112(10):915-916 https://doi.org/10.1016/j.clineuro.2010.07.013
- Pacheco KA. Allergy to surgical implants. Clin Rev Allergy Immunol 2019;56(01):72-85 https://doi.org/10.1007/s12016-018-8707-y
- Shah AM, Jung H, Skirboll S. Materials used in cranioplasty: a history and analysis. Neurosurg Focus 2014;36(04):E19
- Frederickson AM, Sekula RF Jr. The utility of calcium phosphate cement in cranioplasty following retromastoid craniectomy for cranial neuralgias. Br J Neurosurg 2013;27(06):808-811 https://doi.org/10.3109/02688697.2013.776670
- Lerch KD. Reliability of cranial flap fixation techniques: comparative experimental evaluation of suturing, titanium miniplates, and a new rivet-like titanium clamp (CranioFix): technical note. Neurosurgery 1999;44(04):902-905 https://doi.org/10.1097/00006123-199904000-00137
- Yasuhara T, Murai S, Mikuni N, Miyamoto S, Date I. Japanese national questionnaire survey in 2018 on complications related to cranial implants in neurosurgery. Neurol Med Chir (Tokyo) 2020;60(07):337-350 https://doi.org/10.2176/nmc.oa.2020-0051
- Marcacci M, Kon E, Zaffagnini S, et al. Reconstruction of extensive long-bone defects in sheep using porous hydroxyapatite sponges. Calcif Tissue Int 1999;64(01):83-90 https://doi.org/10.1007/s002239900583