• Title/Summary/Keyword: disk assessment

Search Result 48, Processing Time 0.019 seconds

Effect of Combined Traditional Acupuncture and Applied Kinesiology on Lumbar Diseases

  • Ahn, Chang Beohm;Lee, Sang-Ju;Park, Yeo Bin;Park, Yun Leong
    • Journal of Acupuncture Research
    • /
    • v.37 no.2
    • /
    • pp.94-101
    • /
    • 2020
  • Background: Several Korean medical doctors have been practicing applied kinesiology (AK), invented in 1964 by Dr. George J Goodheart, USA. Although the efficacy of traditional acupuncture (TA) and pharmacopucture treatment for lumbar conditions/diseases has been examined, the possible benefits of combining TA and AK have not been reported. Therefore, the aim of this study was to report the effects of combining TA and AK treatment for lumbar disorders using the Japanese Orthopedic Association lumbar score (JOALS) assessment. Methods: There were 21 outpatients treated at Samse Korean Traditional Hospital between March 2018 and September 2018, who presented with L4/L5 or L5/S1 root radiculopathy associated with lumbar spinal stenosis (LSS) and lumbar herniation of intervertebral disk (LHID). They were treated 10×(2 sessions per week, for 5 weeks) with TA and AK approaches that included a category block, manipulation or strain/counterstrain treatments. The primary outcome was mainly assessed using the JOALS score which was used before (0 ×), during (5 ×), and after treatment (10 ×). Results: There were 19 patients diagnosed with LSS and 2 were diagnosed with LHID. Using the JOALS assessment, TA and AK combined approaches improved the lumbar conditions of all 21 patients after 5 × treatmentsand continued to improve after 10 × treatments (p < 0.001). Conclusion: Combined TA and AK treatment was effective in treating spinal conditions/diseases. Prospective, relevant, well-controlled protocols for TA and AK therapies for various conditions are needed.

Effect of Sliding Speed on Wear Characteristics of Polyurethane Seal (미끄럼 속도 변화에 따른 폴리우레탄 씰의 마모 특성)

  • Kim, Hansol;Jeon, Hong Gyu;Chung, Koo-Hyun
    • Tribology and Lubricants
    • /
    • v.34 no.2
    • /
    • pp.49-54
    • /
    • 2018
  • Hydraulic reciprocating seal has been widely used to prevent fluid leakage in hydraulic systems. Also, hydraulic reciprocating seal plays a significant role to provide lubricant film at contacting interface to minimize tribological problems due to sliding with counter material. To predict lifetime of hydraulic reciprocating seal, quantitative understanding of wear characteristics with respect to operating conditions such as normal force and sliding speed is needed. In this work, effect of sliding speed on wear of polyurethane (PU) hydraulic reciprocating seal were experimentally investigated using a pin-on-disk tribo-tester. The wear characteristics of PU specimens were quantitatively determined by comparing the confocal microscope data before and after test. It was found that the wear rate of PU specimens decreased from $4.9{\times}10^{-11}mm^3$ to $1.1{\times}10^{-11}mm^3/Nm$ as sliding speed increased from 120 mm/s to 940 mm/s. Also, it was observed that the friction decreased slightly as the sliding speed increased. Improvement of lubrication state with increasing sliding speed was likely to be responsible for this enhanced friction and wear characteristics. This result also suggests that decrease in sliding distance between PU elastomer and counter materials at lower sliding speed is preferred. Furthermore, the quantitative assessment of wear characteristics of PU specimen may be useful in prediction of lifetime of PU hydraulic reciprocating seal if the allowed degree of wear for failure of the seal is provided.

Study on the Dosimetry and Assessment of Terrestrial Radiation Exposure (지각 방사선에 의한 피폭선량측정 및 해석)

  • Jun, Jae-Shik;Oh, Hi-Peel;Ha, Chung-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.15 no.2
    • /
    • pp.87-100
    • /
    • 1990
  • For the quantitative evaluation and assessment of radiation exposure from terrestrial component of natural environmental radiation, successive thermoluminescence dosimetry and periodical in-situ gamma ray spectrometry were carried out for a period of 24 months. LiF PTFE dise TLDs and $3&{\phi}{\times}3'$cylindrical NaI(Tl)scintill ation detector in association of portable multichannel analyzer (4096 ch) were used in this study. The doses measured were evaluated and assessed in terms of effective dose equivalent. As a concomitant output, the dose equivalent due to ionizing component of cosmic ray was able to be evaluated. According to the results obtained in terms of variance weighted mean, the annual effective dose equivalents of terrestrial gamma ray and cosmic ray ionizing component in Taejeon area came out to be $564{\pm}4\;{\mu}Sv(64.8{\pm}0.5nSv{\cdot}h^{-1}$ and $300{\pm}2\;{\mu}Sv(34.3{\pm}0.2nSv{\cdot}h^{-1}$, respectively, which are reasonable comparably with that appeared in UNSCEAR Report[28]as per caput annual effective dose equivalent in 'areas of normal background radiation'.

  • PDF

THE RELATIONSHIP BETWEEN MANDIBULAR ASYMMETRY AND TEMPOROMANDIBULAR JOINT DISC DISPLACEMENT ON MRI (하악 비대칭과 자기공명영상에서의 측두하악관절 원판변위와의 관계)

  • Choi, Young-Yuhn;Huh, Jong-Ki;Song, Yeong-Bok;Gho, Won-Gyung;Kim, Hyung-Gon
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.29 no.1
    • /
    • pp.35-42
    • /
    • 2003
  • Purpose: This study was aimed to investigate the relationship between the mandibular asymmetry and the internal derangement of temporomandibular joint. Materials and methods: One hundred and sixty eight patients had been assessed through clinical examinations, panoramic radiographs and magnetic resonance imagings (MRIs), were selected. The samples were classified into three subgroups according to the severity of the mandibular asymmetries in the panoramic radiographs and the status of TMJ discs on the MRI were compared among each groups. Results: In an apparent asymmetry group, there was a significant difference in the number of temporomandibular disk displacement without reduction between the long and short side (66.7%, 18/27 joints on the short side) when the ratio of condylar process and coronoid process was used (p<0.05), but there was no statistically significant difference when the ratio of condyle and ramus was used. Conclusion: The probability of the disc displacement without reduction was higher at the side with relatively shorter condylar process on the panoramic radiograph, and also it might be more effective to use ratio of condylar process and coronoid process in the assessment of mandibular asymmetry. Therefore, a careful assessment on the temporomandibular disorders is necessary to diagnose and establish the treatment plans for the patients with a mandibular asymmetry and the panoramic radiograph can be used effectively on that way.

Clinical Features of Wrist Drop Caused by Compressive Radial Neuropathy and Its Anatomical Considerations

  • Han, Bo Ram;Cho, Yong Jun;Yang, Jin Seo;Kang, Suk Hyung;Choi, Hyuk Jai
    • Journal of Korean Neurosurgical Society
    • /
    • v.55 no.3
    • /
    • pp.148-151
    • /
    • 2014
  • Objective : Posture-induced radial neuropathy, known as Saturday night palsy, occurs because of compression of the radial nerve. The clinical symptoms of radial neuropathy are similar to stroke or a herniated cervical disk, which makes it difficult to diagnose and sometimes leads to inappropriate evaluations. The purpose of our study was to establish the clinical characteristics and diagnostic assessment of compressive radial neuropathy. Methods : Retrospectively, we reviewed neurophysiologic studies on 25 patients diagnosed with radial nerve palsy, who experienced wrist drop after maintaining a certain posture for an extended period. The neurologic presentations, clinical prognosis, and electrophysiology of the patients were obtained from medical records. Results : Subjects were 19 males and 6 females. The median age at diagnosis was 46 years. The right arm was affected in 13 patients and the left arm in 12 patients. The condition was induced by sleeping with the arms hanging over the armrest of a chair because of drunkenness, sleeping while bending the arm under the pillow, during drinking, and unknown. The most common clinical presentation was a wrist drop and paresthesia on the dorsum of the 1st to 3rd fingers. Improvement began after a mean of 2.4 weeks. Electrophysiologic evaluation was performed after 2 weeks that revealed delayed nerve conduction velocity in all patients. Conclusion : Wrist drop is an entrapment syndrome that has a good prognosis within several weeks. Awareness of its clinical characteristics and diagnostic assessment methods may help clinicians make diagnosis of radial neuropathy and exclude irrelevant evaluations.

One Year of GOCI-II Launch Present and Future (GOCI-II 발사 1년, 현재와 미래)

  • Choi, Jong-kuk;Park, Myung-sook;Han, Kyung-soo;Kim, Hyun-cheol;Im, Jungho
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.5_2
    • /
    • pp.1229-1234
    • /
    • 2021
  • GOCI-II, which succeeded the mission of GOCI, was successfully launched in February 2020 and is in operation. GOCI-II is expected to be highly useful in a wide range of fields, including detailed changes in the coastal seawater environment using improved spatial and spectral resolution, increased number of observation and full disk observation mode. This special issue introduces the assessment of the current GOCI-II data quality and the studies on the accuracy improvement and applications at this time of one year after launch and data disclosure. We expect that this issue can be an opportunity for GOCI-II data to be actively utilized not only in the ocean but also in various fields of land and atmosphere.

Genomic Characterization and Safety Assessment of Bifidobacterium breve BS2-PB3 as Functional Food

  • Kristin Talia Marbun;Marcelia Sugata;Jonathan Suciono Purnomo;Dikson;Samuel Owen Mudana;Tan Tjie Jan;Juandy Jo
    • Journal of Microbiology and Biotechnology
    • /
    • v.34 no.4
    • /
    • pp.871-879
    • /
    • 2024
  • Our group had isolated Bifidobacterium breve strain BS2-PB3 from human breast milk. In this study, we sequenced the whole genome of B. breve BS2-PB3, and with a focus on its safety profile, various probiotic characteristics (presence of antibiotic resistance genes, virulence factors, and mobile elements) were then determined through bioinformatic analyses. The antibiotic resistance profile of B. breve BS2-PB3 was also evaluated. The whole genome of B. breve BS2-PB3 consisted of 2,268,931 base pairs with a G-C content of 58.89% and 2,108 coding regions. The average nucleotide identity and whole-genome phylogenetic analyses supported the classification of B. breve BS2-PB3. According to our in silico assessment, B. breve BS2-PB3 possesses antioxidant and immunomodulation properties in addition to various genes related to the probiotic properties of heat, cold, and acid stress, bile tolerance, and adhesion. Antibiotic susceptibility was evaluated using the Kirby-Bauer disk-diffusion test, in which the minimum inhibitory concentrations for selected antibiotics were subsequently tested using the Epsilometer test. B. breve BS2-PB3 only exhibited selected resistance phenotypes, i.e., to mupirocin (minimum inhibitory concentration/MIC >1,024 ㎍/ml), sulfamethoxazole (MIC>1,024 ㎍/ml), and oxacillin (MIC >3 ㎍/ml). The resistance genes against those antibiotics, i.e., ileS, mupB, sul4, mecC and ramA, were detected within its genome as well. While no virulence factor was detected, four insertion sequences were identified within the genome but were located away from the identified antibiotic resistance genes. In conclusion, B. breve BS2-PB3 demonstrated a sufficient safety profile, making it a promising candidate for further development as a potential functional food.

The Assessment of Ceramic Wear by the Parameter Scf (Scf 파라메타에 의한 세라믹 마멸 평가)

  • 김상우;김석삼
    • Tribology and Lubricants
    • /
    • v.12 no.1
    • /
    • pp.56-65
    • /
    • 1996
  • The result of wear test for ceramic materials was assessed by Scf parameter to verify the usefulness of the proposed Scf parameter. Friction and wear tests were carried out with ball on disk type. The materials used in this study were HIPed Alumina $(Al_2O_3)$, Silicon carbide (sic), Silicon nitride $(Si_3N_4)$ and Zirconia $(ZrO_2)$. The tests were carried out at room temperature with self mated couples of ceramic materials under lubricated condition. Turbine oil was used as a lubricant. In this test, increasing the load, specific wear rates and wear coefficients of four kinds of ceramic materials had a tendency to increase. The wear coefficients of ceramic materials were in order of $Al_2O_3, SiC, Si_3N_4, ZrO_2$. Worn surfaces investigated by SEM had residual surface cracks and wear particles caused by brittle fracture. As the fracture toughness of ceramic materials was higher, wear resistance more increased. The roughness of worn surface had correlation with wear rate. The wear rate(W$_{s}$) and Scf parameter showed linear relationship in log-log coordinates and the wear equation was given as $W_s = 5.52 $\times$ Scf^{5.01}$.

Frictional Instabilities of Polymer Composite Containing Barite or Potassium Titanate for Brake Linings

  • Kim, Seong-Jin;Jang, Ho
    • KSTLE International Journal
    • /
    • v.4 no.2
    • /
    • pp.60-65
    • /
    • 2003
  • Tribological properties of novolac resin composites containing particulate barite (BaSO$_4$) or potassium titanate (K$_2$Oㆍ6(TiO$_2$))whiskers (two typical space fillers for commercial automotive brake linings) were investigated. The emphasis of the current investigation was given to the effect of the two fillers on the propensity of the stick-slip phenomena and formation of stable rubbing surface. A block-on-disk type tribometer was used for friction assessment. Results showed that the BaSO$_4$-filled composite produced large friction force oscillations at slow sliding speeds and created severe damage on the gray iron counter surface. On the other hand, the composite with $K_2$Oㆍ6(TiO$_2$) whiskers formed a stable rubbing surface and showed smooth sliding behavior without large friction force fluctuation. The microscopic observation of the rubbing surface revealed that the $K_2$Oㆍ6(TiO$_2$)whiskers played a key role in the formation of stable rubbing surface and smooth sliding behavior by effectively reinforcing the resin.

Analysis of Wear Debris for Machine Condition Diagnosis of the Lubricated Moving Surface (기계윤활 운동면의 작동상태 진단을 위한 마멸분 해석)

  • Seo, Yeong-Baek;Park, Heung-Sik;Jeon, Tae-Ok
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.5
    • /
    • pp.835-841
    • /
    • 1997
  • Microscopic examination of the morphology of wear debris is an accepted method for machine condition and fault diagnosis. However wear particle analysis has not been widely accepted in industry because it is dependent on expert interpretation of particle morphology and subjective assessment criteria. This paper was undertaken to analyze the morphology of wear debris for machine condition diagnosis of the lubricated moving surfaces by image processing and analysis. The lubricating wear test was performed under different sliding conditions using a wear test device made in our laboratory and wear testing specimen of the pin-on-disk-type was rubbed in paraffine series base oil. In order to describe characteristics of debris of various shape and size, four shape parameters (50% volumetric diameter, aspect, roundness and reflectivity) have been developed and outlined in the paper. A system using such techniques promises to obviate the need for subjective, human interpretation of particle morphology in machine condition monitoring, thus to overcome many of the difficulties in current methods and to facilitate wider use of wear particle analysis in machine condition monitoring.