• Title/Summary/Keyword: disk

Search Result 5,520, Processing Time 0.043 seconds

Application of the Extract of Zanthoxylum piperitum DC to Manufacturing Eco-friendly Nosocomial Infection Control Protective Materials (초피의 항균 활성을 이용한 원내 감염 제어 친환경 방호 소재 개발)

  • Shin Young Park;Ki Yun Kim;Do Youn Jun;Sung Chul Kim;Hyo-Il Jung;Young Ho Kim
    • Journal of Life Science
    • /
    • v.33 no.10
    • /
    • pp.820-827
    • /
    • 2023
  • Since COVID-19 began at the end of 2019, the wearing time of protective clothing used to prevent pathogenic bacteria and virus infection has increased, and the development of safe protective materials that are human-friendly and have antibacterial and antiviral functions has been required. In this study, we investigated the possibility of developing natural antibacterial protection materials using ethanol extract of the medicinal plant Zanthoxylum Piperitum DC. The antibacterial activity assay of the 80% ethanol extract of Z. piperitum DC leaves against various nosocomial infectious bacteria, using the disk diffusion method, showed that Staphylococcus aureus ATCC 25923, Klebsiella pneumoniae ATCC 13883, Salmonella typhimurium, and Aeromonas hydrophila are sensitive to the inhibitory action of the extract. The IC50 values of the ethanol extract against S. aureus, K. pneumoniae, P. vulgaris and A. hydrophila were about 0.59 mg/ml, 0.50 mg/ml, 1.06 mg/ml, and 0.06 mg/ml, respectively. To determine whether the ethanol extract of Z. piperitum DC leaves can be applied to the development of antibacterial protective fabric, the ethanol extract was tested using a protective fabric from the KM Health Care Corp. using the JIS L1902-Absorption method. As a result, the bacteriostatic and bactericidal activity values of S. aureus ATCC 25923 and K. pneumoniae ATCC 13883 appeared to be more than 2.0 when treated with the ethanol extract at a concentration of 1% (w/v). Together, these results suggest that Z. piperitum DC leaves can be applied to develop natural antibacterial functional protective fabrics.

An Iterative, Interactive and Unified Seismic Velocity Analysis (반복적 대화식 통합 탄성파 속도분석)

  • Suh Sayng-Yong;Chung Bu-Heung;Jang Seong-Hyung
    • Geophysics and Geophysical Exploration
    • /
    • v.2 no.1
    • /
    • pp.26-32
    • /
    • 1999
  • Among the various seismic data processing sequences, the velocity analysis is the most time consuming and man-hour intensive processing steps. For the production seismic data processing, a good velocity analysis tool as well as the high performance computer is required. The tool must give fast and accurate velocity analysis. There are two different approches in the velocity analysis, batch and interactive. In the batch processing, a velocity plot is made at every analysis point. Generally, the plot consisted of a semblance contour, super gather, and a stack pannel. The interpreter chooses the velocity function by analyzing the velocity plot. The technique is highly dependent on the interpreters skill and requires human efforts. As the high speed graphic workstations are becoming more popular, various interactive velocity analysis programs are developed. Although, the programs enabled faster picking of the velocity nodes using mouse, the main improvement of these programs is simply the replacement of the paper plot by the graphic screen. The velocity spectrum is highly sensitive to the presence of the noise, especially the coherent noise often found in the shallow region of the marine seismic data. For the accurate velocity analysis, these noise must be removed before the spectrum is computed. Also, the velocity analysis must be carried out by carefully choosing the location of the analysis point and accuarate computation of the spectrum. The analyzed velocity function must be verified by the mute and stack, and the sequence must be repeated most time. Therefore an iterative, interactive, and unified velocity analysis tool is highly required. An interactive velocity analysis program, xva(X-Window based Velocity Analysis) was invented. The program handles all processes required in the velocity analysis such as composing the super gather, computing the velocity spectrum, NMO correction, mute, and stack. Most of the parameter changes give the final stack via a few mouse clicks thereby enabling the iterative and interactive processing. A simple trace indexing scheme is introduced and a program to nike the index of the Geobit seismic disk file was invented. The index is used to reference the original input, i.e., CDP sort, directly A transformation techinique of the mute function between the T-X domain and NMOC domain is introduced and adopted to the program. The result of the transform is simliar to the remove-NMO technique in suppressing the shallow noise such as direct wave and refracted wave. However, it has two improvements, i.e., no interpolation error and very high speed computing time. By the introduction of the technique, the mute times can be easily designed from the NMOC domain and applied to the super gather in the T-X domain, thereby producing more accurate velocity spectrum interactively. The xva program consists of 28 files, 12,029 lines, 34,990 words and 304,073 characters. The program references Geobit utility libraries and can be installed under Geobit preinstalled environment. The program runs on X-Window/Motif environment. The program menu is designed according to the Motif style guide. A brief usage of the program has been discussed. The program allows fast and accurate seismic velocity analysis, which is necessary computing the AVO (Amplitude Versus Offset) based DHI (Direct Hydrocarn Indicator), and making the high quality seismic sections.

  • PDF

THE EFFECTS OF VARIOUS TETRACYCLINE HCL CONCENTRATION TREATED ROOW SURFACES ON PROLIFERATION AND SPREADING OF PERIODONTAL LIGAMENT CELLS (다양한 농도의 테트라사이클린로 처리된 치근면이 치주인대세포의 증식과 전개에 미치는 영향)

  • Jung, Oh-Chul;Sun, Jo-Young
    • Journal of Periodontal and Implant Science
    • /
    • v.24 no.3
    • /
    • pp.581-596
    • /
    • 1994
  • This in vitro study was undertaken to obtain optimal tetracycline concentration that aids proliferation and spreading of human periodontal ligament cells, for clinical application in root surfaces of periodontally diseased teeth. Periodontal ligament cells used in this study were obtained from explants of periodontal ligament of 1st premolar teeth which were extracted for the purpose of orthodontic treatment. The cells were cultured in Dulbecco's Modified Eagle Medium(DMEM) supplemented with 100 U/ml penicillin, $100\;{\mu}g/ml$ streptomycin and 10% FBS at $37^{\circ}C$, 100% humidity, 5% $CO_2-95%$ air. Cells were used between the third to 4th passage. After root planing of periodontally extracted teeth, the root slabs were cut with carborundum disk. In the cell proliferation experiment, experimental groups were root planing only group, immersed groups in 25, 50, 75, 100, 150mg/ml aqueous solution of Tetracycline HCl followed by a vigorous rinse in PBS. Human PDL cells at concentration of $1{\times}10^5\;cells/ml$ were seeded in each culture well which contained root slabs and incubated for 6 hours. Then, all of the root slabs were moved into new 24 culture well and incubated 24, 48 and 72 hours. The cell counting was done by inverted phase contrast microscope after trypsinization. The following results were obtained. The cell number was increased in order root planing only group, 25, 150, 50, 75, 100mg/ml of Tetracycline HCl treated group in 24, 48 and 72 hours. The maximal cell number was obtained when the root slabs were immersed in solution with 100mg/ml of Tetracycline HCl. There were statistically significant between the root planing only group and 75, 100 mg/ml of Tetracycline HCl treated group in 24 hours, between the root planing only group and 100mg/ml of Tetracycline HCl treated group in 48 hours, between the root planing only group and 50, 75, 100mg/ml of Tetracycline HCl treated group, between 25 and 100mg/ml of Tetracycline HCl treated group in 72 hours(p<0.05). In the cell spreading experiment, after 30 minutes of incubated, in the root planing only group, the cells were generally round in shape. The cell surface was mostly covered with blebs. The cells started to attach to root surface by cytoplasmic extension in 50, 100mg/ml of Tetracycline HCl treated groups, more numerous cells attached to root surface than root planing only group. Many orifices of dentinal tubule were exposed, cells showed radially spreaded cytoplasm and unspreaded central region of the cell was covered with blebs. After 6 hours of incubation, in the root planing only group, cells showed radially spreaded cytoplasm and were attached flat appearance. In 50, 100mg/ml of Tetracycline HCl treated groups, cellular margin was concaved and cytoplasm showed elongated appearance with polarity. After 24 hours of incubation, in the root planing group, cells showed characteristic polarity. In 50, 100mg/ml of Tetracycline HCl treated groups, cells showed more elongated and spindle - like appearance.

  • PDF

Development of Standard Process for Private Information Protection of Medical Imaging Issuance (개인정보 보호를 위한 의료영상 발급 표준 업무절차 개발연구)

  • Park, Bum-Jin;Yoo, Beong-Gyu;Lee, Jong-Seok;Jeong, Jae-Ho;Son, Gi-Gyeong;Kang, Hee-Doo
    • Journal of radiological science and technology
    • /
    • v.32 no.3
    • /
    • pp.335-341
    • /
    • 2009
  • Purpose : The medical imaging issuance is changed from conventional film method to Digital Compact Disk solution because of development on IT technology. However other medical record department's are undergoing identification check through and through whereas medical imaging department cannot afford to do that. So, we examine present applicant's recognition of private intelligence safeguard, and medical imaging issuance condition by CD & DVD medium toward various medical facility and then perform comparative analysis associated with domestic and foreign law & recommendation, lastly suggest standard for medical imaging issuance and process relate with internal environment. Materials and methods : First, we surveyed issuance process & required documents when situation of medical image issuance in the metropolitan medical facility by wire telephone between 2008.6.1$\sim$2008.7.1. in accordance with the medical law Article 21$\sim$clause 2, suggested standard through applicant's required documents occasionally - (1) in the event of oneself $\rightarrow$ verifying identification, (2) in the event of family $\rightarrow$ verifying applicant identification & family relations document (health insurance card, attested copy, and so on), (3) third person or representative $\rightarrow$ verifying applicant identification & letter of attorney & certificate of one's seal impression. Second, also checked required documents of applicant in accordance with upper standard when situation of medical image issuance in Kyung-hee university medical center during 3 month 2008.5.1$\sim$2008.7.31. Third, developed a work process by triangular position of issuance procedure for situation when verifying required documents & management of unpreparedness. Result : Look all over the our manufactured output in the hospital - satisfy the all conditions $\rightarrow$ 4 place(12%), possibly request everyone $\rightarrow$ 4 place(12%), and apply in the clinic section $\rightarrow$ 9 place(27%) that does not medical imaging issuance office, so we don't know about required documents condition. and look into whether meet or not the applicant's required documents on upper 3month survey - satisfy the all conditions $\rightarrow$ 629 case(49%), prepare a one part $\rightarrow$ 416 case(33%), insufficiency of all document $\rightarrow$ 226case(18%). On the authority of upper research result, we are establishing the service model mapping for objective reception when image export situation through triangular position of issuance procedure and reduce of friction with patient and promote the patient convenience. Conclusion : The PACS is classified under medical machinery that mean indicates about higher importance of medical information therefore medical information administrator's who already received professional education & mind, are performer about issuance process only and also have to provide under ID checking process exhaustively.

  • PDF

Origin of Organic Matter and Geochemical Variation of Upper Quaternary Sediments from the Ulleung Basin (울릉분지 상부 제4기 퇴적물의 유기물 기원 및 지화학적 분포)

  • Kim, Ji-Hoon;Park, Myong-Ho;Ryu, Byong-Jae;Lee, Young-Joo;Oh, Jae-Ho;Cheong, Tae-Jin;Chang, Ho-Wan
    • Economic and Environmental Geology
    • /
    • v.40 no.5
    • /
    • pp.605-622
    • /
    • 2007
  • Elemental, Rock-Eval pyrolysis and isotopic analysis of the core sediments from the northwestern and eastern Ulleung Basin of the East were carried out to identify their geochemical characteristics, spatial and vertical variation and origin of organic matter in Upper Quaternary sediments from the northwestern and eastern Ulleung Basin of the East Sea. TOC, m and TS did not show spatial variation between the sampling locations whereas they showed systematic vertical variation associated with MIS stages related to the sea-level change of the East Sea. It is suggested that these past changes of sea-level influenced the sedimentary depositional environments and/or diagenesis which resulted the patterns observed in this study. Based on the results of TOC/N, TS/TOC, ${\delta}^{13}C_{org}\;and\;{\delta}^{15}N_{org}$ analysis, organic matters in the study area appears to be predominantly originated from the marine algae rather than land plant and deposited under normal marine oxic condition during MIS I and MIS III period, and under euxinic/anoxic condition during MIS II period. TOC/N, ${\delta}^{13}C_{org}\;and\;{\delta}^{15}N_{org}$ have a relatively constant value irrespective of MIS stages, implying that the organic matter source does not change by the sea-level fluctuations. However, the results of Rock-Eval pyrolysis indicates that the organic matter is in immature stage and originated from land-plant (Type III), locating in the immature stage land plant (Type III). Similar differences were reported from other areas such as the Atlantic Ocean, Iberia Abyssal Plain, Mediterranean Sea, suggesting that Rock-Eval method does not exactly reflect the characteristic of immature organic matters. Accordingly, the application of Rock-Eval pyrolysis for delineating the source of immature organic matters should be approached with caution and all other geochemical proxies should be considered altogether at the same time.

A Study of the Health Service Computerization State and the Occupational Nurses's Satisfaction Level on Computerization (산업간호현장의 보건업무 전산화시스템 활용현황과 산업간호사의 전산화 직무만족도 연구)

  • Jung, Hee Young;Park, Hyoung-Sook
    • Korean Journal of Occupational Health Nursing
    • /
    • v.13 no.1
    • /
    • pp.5-18
    • /
    • 2004
  • This study aims to investigate the use state of the health service computerization system in the occupational nursing field and the occupational nursers' satisfaction level, and provide basic data to promote the development of the health service computerization system for the nursing field. For this study, a questionnaire was provided to 118 occupational nurses who belong to Busan and Gyeongnam branches of KAOHN(Korean Association of Occupational Health Nurses) for 2 months (from Dec. 1, 2002 to Jan. 31, 2003). A tool of Choi Yong-Heui(2000) was used to investigate the satisfaction level of using the health service computerization system. The collected materials were analyzed in real number and percentage, average and standard deviation, t-test and ANOVA by using the SPSS WIN 10.0 program. This study is summarized as follows: 1. The average age was $31.99{\pm}5.58$ old in this study. The married were 54.2%. Participants who graduated from a junior college was 76.9%. The average service period was $4.48{\pm}4.68$ years. In service types, 79.7% of participants served in a health care center. The average service period was $3.22{\pm}2.89$ years. The service place which had 1000 workers or more was 35.6%. 2. Only 20.3% of participants in this study had a computer use education. 3. The field who participants used mostly was communication/internet, $3.29{\pm}.85$ hours in average. 4. 97.1% of occupational fields had computers and peripheral devices: 71.4% in pentium computer, 42.8% in the hard disk capacity of 20-29GB, 60.0% in 15 inch monitors, 86.2% in printers, 18.1% in digital cameras, 12.4% in LAN, and 9.5% in scanners. 80.1% of the occupational fields which were objects of study could use communication. 5. The occupational fields which did not introduced the health service computerization system were 62.8%. The main cause was attributable to entrepreneurs' insufficient recognition 66.6%. 51.5% of the entrepreneurs did not have an introduction plan. 37.2% of participating companies had the health service computerization system. 56.4% of them introduced it since the year 2000. 81.6% of the introduction motivation aimed to the efficiency of health service. The most issue upon introduction was insufficient understanding of a person in charge - 25.6%. The in-house development of the system covered 56.4%. 61.5% of the participants accepted their demands from the first stage of development. The direct effect of computerization showed the increase of 25.9% in the quickness and continuity of service treatment, and 25.9% in the serviceability of statistical treatment. 6. 22.0% of the participants had a computerization system use education. 69.2% of them had a in-house education. An educational method by nurses who used the computerization system was 76.9%. 92.3% of the education was helpful for practical duties. 7. An analysis of the computer use by health service fields showed that the medicine management in a health management field was 15.9%. the work environment measuring management in a work environment filed was 32.9%. the employment. general and special examination management in a heal th management field was 61.1 %. the various reports management in an administrative field was 64%. the health education data preparation management in an educational field was 58.0%. and the medicine and expendables management in an equipment management field was 51.6%. An analysis of the computerization system use showed that the various statistical data manage in a health management field was 13.0%. the work environment measuring management in a health management field was 34.8%. the personal disease management in a health management field was 51.9%. the heal education data preparation management in an educational field was 54.5%. and the equipment management of health care centers in an equipment management field was 52.6%. 8. 31.6% of the participants wanted that health service computerization system would include the generals of health services. 42.4% of the participants thought that first of all. the aggressive interest and investment of employers were required to build the health service computerization system. 9. The participants' satisfaction level on the computerization system use was $3.51{\pm}.57$ points. An analysis by each factor showed $3.62{\pm}.68$ points in a service change factor. $3.15{\pm}.63$ points in a computer program use factor, and $3.45{\pm}.71$ points in a continuous computerization use factor. 10. An analysis of the computerization system use by general characteristics of participants showed that the married (p = .022) had the satisfaction level higher than the unmarried. 11. The satisfaction level of the computerization system use by participants' computer use ability tended to be higher in proportion to the increase of computer use abilities in spreadsheet (F=2.606. p=.048). presentation (F=3.62. p=.012) and communication/internet(F=2.885. p=.0321. Based on the study results mentioned above. I will suggest as follows : The nationwide enlargement and repetition study is required for occupational nurses who serve in occupational nursing fields. The computerization system in a health service field is inferior comparing with other fields. The computerization system standard by business types and characteristics should be prepared through employers's aggressive participation and national support. Therefore various statistical data which occurs in occupational fields will be managed systematically and efficiently. A regular and systematic computer education plan for occupational nurses in charge of health services in the filed is urgently required to efficiently manage and improve the health of on-site workers.

  • PDF

The recent essay of Bijeung - Study of III- (비증(痺證)에 대(對)한 최근(最近)의 제가학설(諸家學說) 연구(硏究) - 《비증전집(痺證專輯)》 에 대(對)한 연구(硏究) III -)

  • Yang, Tae-Hoon;Oh, Min-Suk
    • Journal of Haehwa Medicine
    • /
    • v.9 no.1
    • /
    • pp.513-545
    • /
    • 2000
  • I. Introduction Bi(痺) means blocking. It can reach at the joints or muscles or whole body and make pains. Numbness and movement disorders. BiJeung can be devided into SilBi and HeoBi. In SilBi there are PungHanSeupBi, YeolBi and WanBi. In HeoBi, there are GiHyeolHeoBi, EumHeoBi and YangHeoBi. The common principle for the treatment of BiJeung is devision of the chronic stage and the acute stage. In the acute stage, BiJeung is usually cured easily but in the chronic stage, it is difficult. In the terminal stage, BiJeung can reach at the internal organs. BiJeung is one kind of symptoms making muscles, bones and jonts feel pain, numbness or edema. For example it can be gout or SLE etc. Many famous doctors studied medical science by their fathers or teachers. So the history of medical science is long. So I studied ${\ll}Bijeungjujip{\gg}$. II. Final Decision 1. BanSuMun(斑秀文) thought that BiJeung can be cured by blocking of blood stream. So he insisted that the important thing to cure BiJeung is to improve the blood stream. He usually used DangGuiSaYeokTang(當歸四逆湯), DangGuiJakYakSanHapORyeongSan, DoHong-SaMulTang(桃紅四物湯), SaMyoSanHapHeuiDongTang and HwangGiGyeJiOMulTang. 2. JangGeonBu(張健夫) focused on soothing muscles and improving blood seam. So he used many herbs like WiRyeongSeon(威靈仙), GangHwal(羌活), DokHwal(獨活), WooSeul(牛膝), etc. Especially he pasted wastes of the boiled herbs. 3. OSeongNong(吳聖農) introduced four rules to treat arthritis. So he usually used SeoGak-SanGaGam(犀角散加減), BoYanHwanOTang(補陽還五湯), ODuTang(烏頭湯), HwangGiGyeJiOMulTang. 4. GongJiSin thought disk hernia as one kind of BiJeung. And he said that Pung can hurt upper limbs and Seup can hurt lower limbs. He used to use GyeJiJakYakJiMoTang(桂枝芍藥知母湯). 5. LoJiJeong(路志正) introduced four principles to treat BiJeung. He used BangPungTang(防風湯), DaeJinGuTang) for PungBi(風痺), OPaeTang(烏貝湯) for HanBi(寒痺), YukGunJaTang(六君子湯) for SeupBi(濕痺) and SaMyoTang(四妙湯), SeonBiTang(宣痺湯), BaekHoGaGyeTang(白虎加桂湯) for YeolBi(熱痺). 6. GangChunHwa(姜春華) discussed herbs. He said SaengJiHwang(生地黃) is effective for PungSeupBi and WiRyungSun(威靈仙) is effective for the joints pain. He usually used SipJeonDaeBoTang(十全大補湯), DangGuiDaeBoTang(當歸大補湯), YoukGunJaTang(六君子湯) and YukMiJiHwanTang(六味地黃湯). 7. DongGeonHwa(董建華) said that the most important thing to treat BiJeung is how to use herbs. He usually used CheonO(川烏), MaHwang(麻黃) for HanBi, SeoGak(犀角) for YeolBi, BiHae) or JamSa(蠶沙) for SeupBi, SukJiHwang(熟地黃) or Vertebrae of Pigs for improving the function of kidney and liver, deer horn or DuChung(杜沖) for improving strength of body and HwangGi(黃?) or OGaPi(五加皮) for improving the function of heart. 8. YiSuSan(李壽山) devided BiJeung into two types(PungHanSeupBi, PungYeolSeupBi). And he used GyeJiJakYakJiMoTang(桂枝芍藥知母湯) for the treatment of gout. And he liked to use HwanGiGyeJiOMulTangHapSinGiHwan 枝五物湯合腎氣丸) for the treat ment of WanBi(頑痺). 9. AnDukHyeong(顔德馨) made YongMaJeongTongDan(龍馬定痛丹)-(MaJeonJa(馬錢子) 30g, JiJaChung 3g, JiRyong(地龍) 3g, JeonGal(全蝎) 3g, JuSa(朱砂) 0.3g) 10. JangBaekYou(張伯臾) devided BiJeung into YeolBi and HanBi. And he focused on improving blood stream. 11. JinMuO(陳茂梧) introduced anti-wind and dampness prescription(HoJangGeun(虎杖根) 15g, CheonChoGeun 15g, SangGiSaeng(桑寄生) 15g, JamSa(蠶絲) 15g, JeMaJeonJa(制馬錢子) 3g). 12. YiChongBo(李總甫) explained basic prescriptions to treat BiJeung. He used SinJeongChuBiEum(新定推痺陰) for HaengBi(行痺), SinJeongHwaBiSan(新定化痺散) for TongBi(痛痺), SinJeongGaeBiTang(新定開痺湯) for ChakBi(着痺), SinJeongCheongBiEum(新定淸痺飮) for SeupYeolBi(濕熱痺), SinRyeokTang(腎瀝湯) for PoBi(胞痺), ORyeongSan for BuBi(腑痺), OBiTang(五痺湯) for JangBi(臟痺), SinChakTang(腎着湯) for SingChakByeong(腎着病). 13. HwangJeonGeuk(黃傳克) used SaMu1SaDeungHapJe(四物四藤合制) for the treatment of a acute arthritis, PalJinHpPalDeungTang(八珍合八藤湯) or BuGyeJiHwangTangHapTaDeungTang(附桂地黃湯合四藤湯) for the chronic stage and ByeolGapJeungAekTongRakEum(鱉甲增液通絡飮) for EumHeo(陰虛) 14. GaYeo(柯與參) used HwalRakJiTongTang(活絡止痛湯) for shoulder ache, SoJongJinTongHwalRakTank(消腫鎭痛活絡湯) for YeolBi(熱痺), LiGwanJeolTang(利關節湯) for ChakBi(着痺), SinBiTang(腎痺湯) for SinBi(腎痺) and SamGyoBoSinHwan(三膠補腎丸) for back ache. 15. JangGilJin(蔣길塵) liked to use hot-character herbs and insects. And he used SeoGeunLipAnTang(舒筋立安湯) as basic prescription. 16. RyuJangGeol(留章杰) used GuMiGangHwalTang(九味羌活湯) and BangPungTang(防風湯) at the acute stage, ODuTang(烏頭湯) or GyeJiJakYakJiMoTang(桂枝芍藥知母湯) for HanBi of internal organs, YangHwaHaeEungTang(陽和解凝湯) for HanBi, DokHwalGiSaengTang(獨活寄生湯), EuiYiInTang(薏苡仁湯) for SeupBi, YukGunJaTang(六君子湯) for GiHeoBi(氣虛痺) and SeongYouTang(聖兪湯) for HyeolHeoBi(血虛痺). 17. YangYuHak(楊有鶴) liked to use SoGyeongHwalHyelTang(疏經活血湯) and he would rather use DoIn(桃仁), HongHwa(紅花), DangGui(當歸), CheonGung(川芎) than insects. 18. SaHongDo(史鴻濤) made RyuPungSeupTang(類風濕湯)-((HwangGi 200g, JinGu 20g, BangGi(防己) 15g, HongHwa(紅花) 15g, DoIn(桃仁) 15g, CheongPungDeung(靑風藤) 20g, JiRyong(地龍) 15g, GyeJi(桂枝) 15g, WoSeul(牛膝) 15g, CheonSanGap(穿山甲) 15g, BaekJi(白芷) 15g, BaekSeonPi(白鮮皮) 15g, GamCho(甘草) 15g).

  • PDF

A Study of Anomaly Detection for ICT Infrastructure using Conditional Multimodal Autoencoder (ICT 인프라 이상탐지를 위한 조건부 멀티모달 오토인코더에 관한 연구)

  • Shin, Byungjin;Lee, Jonghoon;Han, Sangjin;Park, Choong-Shik
    • Journal of Intelligence and Information Systems
    • /
    • v.27 no.3
    • /
    • pp.57-73
    • /
    • 2021
  • Maintenance and prevention of failure through anomaly detection of ICT infrastructure is becoming important. System monitoring data is multidimensional time series data. When we deal with multidimensional time series data, we have difficulty in considering both characteristics of multidimensional data and characteristics of time series data. When dealing with multidimensional data, correlation between variables should be considered. Existing methods such as probability and linear base, distance base, etc. are degraded due to limitations called the curse of dimensions. In addition, time series data is preprocessed by applying sliding window technique and time series decomposition for self-correlation analysis. These techniques are the cause of increasing the dimension of data, so it is necessary to supplement them. The anomaly detection field is an old research field, and statistical methods and regression analysis were used in the early days. Currently, there are active studies to apply machine learning and artificial neural network technology to this field. Statistically based methods are difficult to apply when data is non-homogeneous, and do not detect local outliers well. The regression analysis method compares the predictive value and the actual value after learning the regression formula based on the parametric statistics and it detects abnormality. Anomaly detection using regression analysis has the disadvantage that the performance is lowered when the model is not solid and the noise or outliers of the data are included. There is a restriction that learning data with noise or outliers should be used. The autoencoder using artificial neural networks is learned to output as similar as possible to input data. It has many advantages compared to existing probability and linear model, cluster analysis, and map learning. It can be applied to data that does not satisfy probability distribution or linear assumption. In addition, it is possible to learn non-mapping without label data for teaching. However, there is a limitation of local outlier identification of multidimensional data in anomaly detection, and there is a problem that the dimension of data is greatly increased due to the characteristics of time series data. In this study, we propose a CMAE (Conditional Multimodal Autoencoder) that enhances the performance of anomaly detection by considering local outliers and time series characteristics. First, we applied Multimodal Autoencoder (MAE) to improve the limitations of local outlier identification of multidimensional data. Multimodals are commonly used to learn different types of inputs, such as voice and image. The different modal shares the bottleneck effect of Autoencoder and it learns correlation. In addition, CAE (Conditional Autoencoder) was used to learn the characteristics of time series data effectively without increasing the dimension of data. In general, conditional input mainly uses category variables, but in this study, time was used as a condition to learn periodicity. The CMAE model proposed in this paper was verified by comparing with the Unimodal Autoencoder (UAE) and Multi-modal Autoencoder (MAE). The restoration performance of Autoencoder for 41 variables was confirmed in the proposed model and the comparison model. The restoration performance is different by variables, and the restoration is normally well operated because the loss value is small for Memory, Disk, and Network modals in all three Autoencoder models. The process modal did not show a significant difference in all three models, and the CPU modal showed excellent performance in CMAE. ROC curve was prepared for the evaluation of anomaly detection performance in the proposed model and the comparison model, and AUC, accuracy, precision, recall, and F1-score were compared. In all indicators, the performance was shown in the order of CMAE, MAE, and AE. Especially, the reproduction rate was 0.9828 for CMAE, which can be confirmed to detect almost most of the abnormalities. The accuracy of the model was also improved and 87.12%, and the F1-score was 0.8883, which is considered to be suitable for anomaly detection. In practical aspect, the proposed model has an additional advantage in addition to performance improvement. The use of techniques such as time series decomposition and sliding windows has the disadvantage of managing unnecessary procedures; and their dimensional increase can cause a decrease in the computational speed in inference.The proposed model has characteristics that are easy to apply to practical tasks such as inference speed and model management.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • Bulletin of the Korean Space Science Society
    • /
    • 1993.10a
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF