Application of the Extract of Zanthoxylum piperitum DC to Manufacturing Eco-friendly Nosocomial Infection Control Protective Materials (초피의 항균 활성을 이용한 원내 감염 제어 친환경 방호 소재 개발)
-
- Journal of Life Science
- /
- v.33 no.10
- /
- pp.820-827
- /
- 2023
Since COVID-19 began at the end of 2019, the wearing time of protective clothing used to prevent pathogenic bacteria and virus infection has increased, and the development of safe protective materials that are human-friendly and have antibacterial and antiviral functions has been required. In this study, we investigated the possibility of developing natural antibacterial protection materials using ethanol extract of the medicinal plant Zanthoxylum Piperitum DC. The antibacterial activity assay of the 80% ethanol extract of Z. piperitum DC leaves against various nosocomial infectious bacteria, using the disk diffusion method, showed that Staphylococcus aureus ATCC 25923, Klebsiella pneumoniae ATCC 13883, Salmonella typhimurium, and Aeromonas hydrophila are sensitive to the inhibitory action of the extract. The IC50 values of the ethanol extract against S. aureus, K. pneumoniae, P. vulgaris and A. hydrophila were about 0.59 mg/ml, 0.50 mg/ml, 1.06 mg/ml, and 0.06 mg/ml, respectively. To determine whether the ethanol extract of Z. piperitum DC leaves can be applied to the development of antibacterial protective fabric, the ethanol extract was tested using a protective fabric from the KM Health Care Corp. using the JIS L1902-Absorption method. As a result, the bacteriostatic and bactericidal activity values of S. aureus ATCC 25923 and K. pneumoniae ATCC 13883 appeared to be more than 2.0 when treated with the ethanol extract at a concentration of 1% (w/v). Together, these results suggest that Z. piperitum DC leaves can be applied to develop natural antibacterial functional protective fabrics.
Among the various seismic data processing sequences, the velocity analysis is the most time consuming and man-hour intensive processing steps. For the production seismic data processing, a good velocity analysis tool as well as the high performance computer is required. The tool must give fast and accurate velocity analysis. There are two different approches in the velocity analysis, batch and interactive. In the batch processing, a velocity plot is made at every analysis point. Generally, the plot consisted of a semblance contour, super gather, and a stack pannel. The interpreter chooses the velocity function by analyzing the velocity plot. The technique is highly dependent on the interpreters skill and requires human efforts. As the high speed graphic workstations are becoming more popular, various interactive velocity analysis programs are developed. Although, the programs enabled faster picking of the velocity nodes using mouse, the main improvement of these programs is simply the replacement of the paper plot by the graphic screen. The velocity spectrum is highly sensitive to the presence of the noise, especially the coherent noise often found in the shallow region of the marine seismic data. For the accurate velocity analysis, these noise must be removed before the spectrum is computed. Also, the velocity analysis must be carried out by carefully choosing the location of the analysis point and accuarate computation of the spectrum. The analyzed velocity function must be verified by the mute and stack, and the sequence must be repeated most time. Therefore an iterative, interactive, and unified velocity analysis tool is highly required. An interactive velocity analysis program, xva(X-Window based Velocity Analysis) was invented. The program handles all processes required in the velocity analysis such as composing the super gather, computing the velocity spectrum, NMO correction, mute, and stack. Most of the parameter changes give the final stack via a few mouse clicks thereby enabling the iterative and interactive processing. A simple trace indexing scheme is introduced and a program to nike the index of the Geobit seismic disk file was invented. The index is used to reference the original input, i.e., CDP sort, directly A transformation techinique of the mute function between the T-X domain and NMOC domain is introduced and adopted to the program. The result of the transform is simliar to the remove-NMO technique in suppressing the shallow noise such as direct wave and refracted wave. However, it has two improvements, i.e., no interpolation error and very high speed computing time. By the introduction of the technique, the mute times can be easily designed from the NMOC domain and applied to the super gather in the T-X domain, thereby producing more accurate velocity spectrum interactively. The xva program consists of 28 files, 12,029 lines, 34,990 words and 304,073 characters. The program references Geobit utility libraries and can be installed under Geobit preinstalled environment. The program runs on X-Window/Motif environment. The program menu is designed according to the Motif style guide. A brief usage of the program has been discussed. The program allows fast and accurate seismic velocity analysis, which is necessary computing the AVO (Amplitude Versus Offset) based DHI (Direct Hydrocarn Indicator), and making the high quality seismic sections.
This in vitro study was undertaken to obtain optimal tetracycline concentration that aids proliferation and spreading of human periodontal ligament cells, for clinical application in root surfaces of periodontally diseased teeth. Periodontal ligament cells used in this study were obtained from explants of periodontal ligament of 1st premolar teeth which were extracted for the purpose of orthodontic treatment. The cells were cultured in Dulbecco's Modified Eagle Medium(DMEM) supplemented with 100 U/ml penicillin,
Purpose : The medical imaging issuance is changed from conventional film method to Digital Compact Disk solution because of development on IT technology. However other medical record department's are undergoing identification check through and through whereas medical imaging department cannot afford to do that. So, we examine present applicant's recognition of private intelligence safeguard, and medical imaging issuance condition by CD & DVD medium toward various medical facility and then perform comparative analysis associated with domestic and foreign law & recommendation, lastly suggest standard for medical imaging issuance and process relate with internal environment. Materials and methods : First, we surveyed issuance process & required documents when situation of medical image issuance in the metropolitan medical facility by wire telephone between 2008.6.1
Elemental, Rock-Eval pyrolysis and isotopic analysis of the core sediments from the northwestern and eastern Ulleung Basin of the East were carried out to identify their geochemical characteristics, spatial and vertical variation and origin of organic matter in Upper Quaternary sediments from the northwestern and eastern Ulleung Basin of the East Sea. TOC, m and TS did not show spatial variation between the sampling locations whereas they showed systematic vertical variation associated with MIS stages related to the sea-level change of the East Sea. It is suggested that these past changes of sea-level influenced the sedimentary depositional environments and/or diagenesis which resulted the patterns observed in this study. Based on the results of TOC/N, TS/TOC,
This study aims to investigate the use state of the health service computerization system in the occupational nursing field and the occupational nursers' satisfaction level, and provide basic data to promote the development of the health service computerization system for the nursing field. For this study, a questionnaire was provided to 118 occupational nurses who belong to Busan and Gyeongnam branches of KAOHN(Korean Association of Occupational Health Nurses) for 2 months (from Dec. 1, 2002 to Jan. 31, 2003). A tool of Choi Yong-Heui(2000) was used to investigate the satisfaction level of using the health service computerization system. The collected materials were analyzed in real number and percentage, average and standard deviation, t-test and ANOVA by using the SPSS WIN 10.0 program. This study is summarized as follows: 1. The average age was
I. Introduction Bi(痺) means blocking. It can reach at the joints or muscles or whole body and make pains. Numbness and movement disorders. BiJeung can be devided into SilBi and HeoBi. In SilBi there are PungHanSeupBi, YeolBi and WanBi. In HeoBi, there are GiHyeolHeoBi, EumHeoBi and YangHeoBi. The common principle for the treatment of BiJeung is devision of the chronic stage and the acute stage. In the acute stage, BiJeung is usually cured easily but in the chronic stage, it is difficult. In the terminal stage, BiJeung can reach at the internal organs. BiJeung is one kind of symptoms making muscles, bones and jonts feel pain, numbness or edema. For example it can be gout or SLE etc. Many famous doctors studied medical science by their fathers or teachers. So the history of medical science is long. So I studied
Maintenance and prevention of failure through anomaly detection of ICT infrastructure is becoming important. System monitoring data is multidimensional time series data. When we deal with multidimensional time series data, we have difficulty in considering both characteristics of multidimensional data and characteristics of time series data. When dealing with multidimensional data, correlation between variables should be considered. Existing methods such as probability and linear base, distance base, etc. are degraded due to limitations called the curse of dimensions. In addition, time series data is preprocessed by applying sliding window technique and time series decomposition for self-correlation analysis. These techniques are the cause of increasing the dimension of data, so it is necessary to supplement them. The anomaly detection field is an old research field, and statistical methods and regression analysis were used in the early days. Currently, there are active studies to apply machine learning and artificial neural network technology to this field. Statistically based methods are difficult to apply when data is non-homogeneous, and do not detect local outliers well. The regression analysis method compares the predictive value and the actual value after learning the regression formula based on the parametric statistics and it detects abnormality. Anomaly detection using regression analysis has the disadvantage that the performance is lowered when the model is not solid and the noise or outliers of the data are included. There is a restriction that learning data with noise or outliers should be used. The autoencoder using artificial neural networks is learned to output as similar as possible to input data. It has many advantages compared to existing probability and linear model, cluster analysis, and map learning. It can be applied to data that does not satisfy probability distribution or linear assumption. In addition, it is possible to learn non-mapping without label data for teaching. However, there is a limitation of local outlier identification of multidimensional data in anomaly detection, and there is a problem that the dimension of data is greatly increased due to the characteristics of time series data. In this study, we propose a CMAE (Conditional Multimodal Autoencoder) that enhances the performance of anomaly detection by considering local outliers and time series characteristics. First, we applied Multimodal Autoencoder (MAE) to improve the limitations of local outlier identification of multidimensional data. Multimodals are commonly used to learn different types of inputs, such as voice and image. The different modal shares the bottleneck effect of Autoencoder and it learns correlation. In addition, CAE (Conditional Autoencoder) was used to learn the characteristics of time series data effectively without increasing the dimension of data. In general, conditional input mainly uses category variables, but in this study, time was used as a condition to learn periodicity. The CMAE model proposed in this paper was verified by comparing with the Unimodal Autoencoder (UAE) and Multi-modal Autoencoder (MAE). The restoration performance of Autoencoder for 41 variables was confirmed in the proposed model and the comparison model. The restoration performance is different by variables, and the restoration is normally well operated because the loss value is small for Memory, Disk, and Network modals in all three Autoencoder models. The process modal did not show a significant difference in all three models, and the CPU modal showed excellent performance in CMAE. ROC curve was prepared for the evaluation of anomaly detection performance in the proposed model and the comparison model, and AUC, accuracy, precision, recall, and F1-score were compared. In all indicators, the performance was shown in the order of CMAE, MAE, and AE. Especially, the reproduction rate was 0.9828 for CMAE, which can be confirmed to detect almost most of the abnormalities. The accuracy of the model was also improved and 87.12%, and the F1-score was 0.8883, which is considered to be suitable for anomaly detection. In practical aspect, the proposed model has an additional advantage in addition to performance improvement. The use of techniques such as time series decomposition and sliding windows has the disadvantage of managing unnecessary procedures; and their dimensional increase can cause a decrease in the computational speed in inference.The proposed model has characteristics that are easy to apply to practical tasks such as inference speed and model management.
The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70
The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70