Analysis of the Dynamic Characteristics of the Underwater Discharge System using a Linear Pump (선형펌프 방식 수중발사 시스템의 동특성 해석)

  • Park, In-Ki;Jung, Chan-Hee
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.8 no.3 s.22
    • /
    • pp.11-17
    • /
    • 2005
  • In this paper, the mathematical model of the underwater discharge system using a linear pump is derived and the suitable opening pattern of a flow control valve which satisfies the discharge performance requirements is obtained through the underwater discharge simulations. The simulation results show that the dynamic characteristics of a projectile are greatly affected by the opening pattern of the flow control valve, however, hardly by the diving depth. It is anticipated that the simulation model can be used to derive the design parameters and analyze the performance of the designed underwater discharge system using a linear pump.

Analysis of Arc Tube Properties by Degradation in Ceramic Metal Halide Lamp

  • Yang, Jong-Kyung;Jang, Hyeok-Jin;Park, Dae-Hee
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.1
    • /
    • pp.123-127
    • /
    • 2011
  • To clarify the relations of optical properties to the main factors responsible for the loss and damage of luminous efficacy, a 20 min turn-on/turn-off test for 2,000 h for a ceramic metal halide lamp is conducted. The corrosion rates of the arc tube wall and electrode are estimated based on thermal stress. Wall blackening is attributed to the tungsten being transported from the hot electrode tips to the relatively cold arc tube wall. Furthermore, the grain boundaries of the arc tube are changed by the degradation. Distortion of the electrode is observed, and the ignition and the driving voltage of the load both increase. Finally, the color rendering index and the color coordinates are changed after the degradation. The luminous flux and the intensity of the luminous distribution are decreased significantly.

Discharge Phenomena of Glass Tube Vacuum under AC Applied Voltage (AC 전압하에서 유리진공관의 방전현상)

  • Choi, Yong-Sung;Hwang, Jong-Sun;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.371-372
    • /
    • 2008
  • In this paper, we experimentally investigated discharge phenomena inside vacuum interrupter at 1 to 20 Torr to simulate the vacuum leakage. We used glass type of vacuum interrupter where the internal pressure and the type of gasses can be varied according to requirement. The experiment is conducted under ac applied voltage and the experimental circuit is constructed to simulate the actual circuit used in cubical type insulated switchgear. We used two types of gases such as air and $SF_6$. The use of glass type vacuum interrupter allowed us to measure discharges occurring in vacuum interrupter optically. We measured and discussed the discharge occurring in both gases with a current transformer and ICCD camera. We also revealed that electromagnetic wave spectra emitted by the discharge have same frequency range for both gasses.

  • PDF

Current-Source Pulse Density Modulated Parallel Resonant Inverter with A Single Resonant Snubber and Its Unique Application

  • Wang Y.X.;Koudriavtsev O.;Konishi Y.;Okuno A.;Nakaoka M.;Lee H.W.
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.261-265
    • /
    • 2001
  • In this paper, a current-source type parallel indudor compensated load resonant high-frequency soft switching inverter using IGBTs for driving the newly-produced silent discharge type ozone generating tube and excimer lamp for UV generation which incorporate a single switched capacitor resonant snubber between the port in DC busline side is presented, together with its pulse modulated unique output power regulation characteristics.

  • PDF

Coherence Analysis of Noise and Vibration For Reciprocating Compressor (왕복동 압축기의 소음 및 진동 기여도 분석)

  • Lee, Dae-Sung;Hwang, Won-Gul;Lee, You-Yub;Im, Hyung-Eun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.875-880
    • /
    • 2002
  • It is necessary to determine the vibration source and its transmission paths in order to develop a low-noise compressor. Through the use of multiple-input/single-output(MISO) mode1, the transmission paths of vibration within a reciprocating compressor have been investigated. In order to identify the transmission path, we measure the accelerations of the block and transverse vibrations of the line discharge tube. As outputs, vibrations of compressor shell were measured at three positions; cylinder head, one near the suction line, and the top of upper shell. The partial coherence function and transfer function are obtained ken the measured data, and the results are observed in order to determine vibration source and its influence on the shell vibration.

  • PDF

Two Versions of He-Ne Laser 3.39 μm with Radio Frequency Excitation

  • Kopica, Miroslaw;Choi, Jong-Woon
    • Journal of the Optical Society of Korea
    • /
    • v.12 no.1
    • /
    • pp.31-37
    • /
    • 2008
  • To increase output power of a He-Ne laser we propose to use the capacitive rf discharge and implement four channel structure. Most of experiments were carried out with a single laser tube from this structure to optimize the output mirror transmission, pressure and composition of the mixture. A laser tube of 2.8 mm inner diameter and 50 cm discharge length can give an output power of above 5.5 mW at 3.39 ${\mu}m$. Four such tubes in "matrix" structure let us obtain 20 mW of output. Simplified models which can be used to evaluate the behavior of an equivalent electrical circuit with laser plasma and qualitative characteristics of output power of He-Ne laser were also described.

The Identification of Vibration Source and Its Transmission Paths In Compressor Using PCF Method (PCF법을 이용한 왕복동압축기의 진동원 및 진동전달경로 규명)

  • Lee, Dae-Sung;Hwang, Won-Gul;Lee, You-Yub;Im, Hyung-Eun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.386.1-386
    • /
    • 2002
  • It is necessary to determine the vibration source and its transmission paths in order to develop a low-noise compressor Through the use of multiple-input/single-output(MISO) model, the transmission paths of vibration within a reciprocating compressor have been investigated. In order to identify the transmission path, we measure the accelerations of the block and transverse vibrations of the line discharge tube. (omitted)

  • PDF

Surgical Treatment of Spontaneous Pneumothorax by Thoracoscopic Wedge Resection with Fibrin Glue (비디오흉강경을 이용한 자연기흉의 치료시 국소적 Fibrin Glue 도포)

  • 신화균
    • Journal of Chest Surgery
    • /
    • v.33 no.10
    • /
    • pp.812-816
    • /
    • 2000
  • Background ; To evaluate the efficacy of Fibrin glue to decrease recurrence in video-assisted thoracoscopic surgery(VATS) for a treatment of spontaneous penumothorax. Material and Method : All medical records of 17 patients who underwent a thoracoscopic wedge resections of bullae with stapling device with Fibrin glue in our institute between May 1998 and December 1999 were reviewed. variables analyzed include affected sites primary indication of VATS. duration from admission to discharge duration of postoperative stay duration of chest tube drainage recurrence and complication. There were 16 men and 1 woman. Result : There was no evidence of hemodynamic instability or arterial blood gas abnormalities encountered during the procedure. Mean age at the time of the VATS was 26.9 years (range 15 to 61 years) The mean duration from admission to discharge was 7.8 days and mean postoperative stay was 5.1days mean chest tube indwelling period was 4..0 days. There was no recurrence of pneumothorx. Conclusion : Thoracoscopic wedge resections with introduction of fibrin glue are safe and effective and requires only a short hospital stay. We believe that this thoracoscopic technique will further simplify the surgical treatment of pneumothorax.

  • PDF

Ozone Generation Characteristics with Varying the Pressures of 3Electrodes-3GaP Discharge Tube (3E-3G 방전관의 압력변화시 오존생성특성)

  • Cho, Kook-Hee;Kim, Young-Bae;Seo, Kil-Soo;Lee, Hyeong-Ho;Lee, Si-Young;Bang, Seung-Woon
    • Proceedings of the KIEE Conference
    • /
    • 1999.11d
    • /
    • pp.1063-1065
    • /
    • 1999
  • Recently the ozone generation system is well used for cleaning the contaminated water by using the strong oxidization effects. Accordingly, with the purpose of improving ozone yield at the peak of ozone concentration, this paper describes the stracture and characteristics of ozonizer, and focused on the development of a 3E-3G discharge tube.

  • PDF

A Study on the Control Technology of Ozone Generations (오존 발생량 제어기술에 관한 연구)

  • Cho, Kook-Hee;Cho, Moon-Soo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.10
    • /
    • pp.94-99
    • /
    • 2006
  • Ozone concentration and flow rate of discharge tube were measured using LabVIEW program in data acquisition part and it was saved. In addition, quantities of ozone generation was adjusted by the collected data, which was performed at control part. Therefore, energy efficiency was improved by suppling quantities of ozone generation according to environmental conditions.