• 제목/요약/키워드: discharge tube

검색결과 337건 처리시간 0.025초

Feasibility and Safety of a New Chest Drain Wound Closure Method with Knotless Sutures

  • Kim, Min Soo;Shin, Sumin;Kim, Hong Kwan;Choi, Yong Soo;Kim, Jhingook;Zo, Jae Ill;Shim, Young Mog;Cho, Jong Ho
    • Journal of Chest Surgery
    • /
    • 제51권4호
    • /
    • pp.260-265
    • /
    • 2018
  • Background: A method of wound closure using knotless suture material in the chest tube site has been introduced at our center, and is now widely used as the primary method of closing chest tube wounds in video-assisted thoracic surgery (VATS) because it provides cosmetic benefits and causes less pain. Methods: We included 109 patients who underwent VATS pulmonary resection at Samsung Medical Center from October 1 to October 31, 2016. Eighty-five patients underwent VATS pulmonary resection with chest drain wound closure utilizing knotless suture material, and 24 patients underwent VATS pulmonary resection with chest drain wound closure by the conventional method. Complications related to the chest drain wound were compared between the 2 groups. Results: There were 2 cases of pneumothorax after chest tube removal in both groups (8.3% in the conventional group, 2.3% in the knotless suture group; p=0.172) and there was 1 case of wound discharge due to wound dehiscence in the knotless suture group (0% in the conventional group, 1.2% in the knotless suture group; p=0.453). There was no reported case of chest tube dislodgement in either group. The complication rates were non-significantly different between the 2 groups. Conclusion: The results for the complication rates of this new chest drain wound closure method suggest that this method is not inferior to the conventional method. Chest drain wound closure using knotless suture material is feasible based on the short-term results of the complication rate.

RF 플라즈마 아킹의 PM-tube를 이용한 광량 측정

  • 김용훈;장홍영
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2010년도 제39회 하계학술대회 초록집
    • /
    • pp.125-126
    • /
    • 2010
  • 플라즈마 아킹은 PECVD, 플라즈마 식각 그리고 토카막과 같은 플라즈마를 이용하는 여러 공정과 연구 분야에서 문제점을 야기시켜왔다. 하지만, 이에 대한 연구는 아킹 현상의 불규칙성과 과도적인 행동으로 인해 미비한 상태이다. 특히, RF 방전에서의 아킹 연구는 DC 방전에서의 아킹 연구에 비해 많이 부족한 것이 현실이다. 플라즈마 아킹은 집단전자방출(collective electron emission)에 의한 스파크 방전(spark discharge)현상이다. 집단전자방출은 전계방출(field emission)이나 플라즈마와 쉬스를 두고 인접한 표면위에서의 유전분극(dielec emission)에 의해 발생한다. 이렇게 방출된 집단 전자들은 쉬스에서 가속되어 에너지를 얻게 되고 원자와의 충돌로 전자 아발란체를 일으킨다. 이렇게 배가된 전자들은 아킹 스트리머(arcing streamer)를 형성하게 되고 아킹 발생 시 높은 전류와 공정 실패의 원인이 된다. 우리는 $30cm{\times}20cm$ 크기의 사각 전극을 위 아래로 가진 챔버에서 Ar 가스를 RF(13.56 MHz)파워를 이용해 방전시켰다. 방전 전압과 전류는 파워 전극 압단에서 High voltage probe (Tektronix P6015A)와 Current probe (TCPA300 + TCP312)를 이용해 측정했다. 플라즈마 아킹시 변하는 플라즈마 플로팅 포텐셜은 챔버 중앙에 위치한 랑뮈프 프로브에 의해 측정되고 챔버 옆의 뷰포트 앞에 위치한 PM-tube를 이용해 아킹시 변하는 광량을 측정한다. RF 방전에서의 플라즈마 아킹은 아킹시 플로팅 포텐셜의 변화에 의해 크게 세부분으로 나눌 수 있다. 아킹 발생과 동시에 급격히 감소하는 감소부분 (약 2us) 그리고 감소한 포텐셜이 유지되는 유지부분 (약 0~10ms) 그리고 감소했던 포텐셜이 서서히 원래 상태로 회복되는 회복부분(약 100 us)이다. 아킹 초기시 방출된 집단 전자들과 원자들간의 충돌에 의해 형성된 아킹 스트리머는 플라즈마 전체를 단락시키게 되고 이로 인해 플로팅 포텐셜은 급격히 감소하게 된다. 이렇게 감소한 플로팅 포텐셜은 아킹 스트리머가 유지되는 한 계속 감소한 상태를 유지하게 된다. 그리고 플라즈마를 섭동했던 아킹 스트리머가 중단되면 플라즈마는 섭동전의 원래 상태로 돌아가려 하기 때문에 플로팅 포텐셜은 서서히 증가하면서 원래 상태로 회복된다. 플라즈마 아킹 발생시 생성되는 아킹 스트리머는 순간적으로 많은 전자들을 국소적으로 생성하게 되고 이 전자들에 의해 광량이 순간적으로 증가하게 된다. PM-tube (750.4 nm)에 의해 측정된 아킹시 광량은 정상방전 상태의 두배 가량이 된다. 그리고 이 순간적으로 증가된 광량은 시간이 지남에 따라 감소하게 되고 정상방전 일때의 광량이 된다. 광량이 증가한 후 정상방전 상태의 광량에 이르는 부분은 플로팅 포텐셜이 감소한 상태에서 유지되는 부분과 일치하고 이는 플로팅 포텐셜의 유지부분동안 아킹 스트리머가 발생하고 있다는 간접적인 증거가 된다. 그리고 정상 방전 상태 일때의 광량이 되면 아킹 스트리머가 중단되었다는 것이므로 그 시점부터 플로팅 포텐셜은 정산 방전상태 일 때의 포텐셜로 복구되기 시작한다. 이처럼 PM-tube를 이용한 아킹 광량 측정은 아킹 스트리머를 간접적으로 측정하게 하고 아킹 스트리머를 이용해 아킹시의 플로팅 포텐셜의 변화를 설명하게 해 준다. 응용적인 측면에서 아킹 광량 측정을 이용한 아킹 판독은 방전 전류와 방전 전압과 같은 전기적 신호를 이용한 아킹 판독에 비해 여러가지 장점을 가진다. 우선, 전기적 신호를 이용한 아킹 판독처럼 매칭 회로나 플라즈마를 섭동시키지 않는다. 그리고 원하는 부분의 아킹만을 판독하는 것도 가능하며 photo-diode를 이용할 경우 전기적 신호를 이용하는 것에 비해 경제적으로 유리하다.

  • PDF

Inconel 600 및 690 튜브 재질의 일반 부식에 관한 실험적 연구 (An Experimental Research on Uniform Corrosion of Inconel 600 and 690 Tubing Material)

  • 염유선;황정래;전인섭;김숭평;윤장희
    • 방사성폐기물학회지
    • /
    • 제4권2호
    • /
    • pp.103-116
    • /
    • 2006
  • 본 논문은 국내 PWR 발전소에서 S/G tube 재질로 사용되고 있는 Inconel 600 및 690에 대한 부식 실험을 수행함으로써 작업자들의 주요 피폭원인 $^{58}Co,\;^{60}Co,\;^{51}Cr,\;^{54}Mn,\;^{59}Fe$의 생성량을 예측하고자 하였다. 이를 위해 Inconel 600 및 690 재질로 총 12개의 시편을 제작하여 실제 발전소의 운전조건과 유사하거나 가혹한 조건에서 전면 부식실험을 pH별로 20일씩 총 60일간 수행하였고, 실험 결과를 정량적으로 분석하기 위해 GDS(Glow Discharge Spectrometer) 장비를 사용하였다. GDS 장비를 이용하여 정량적으로 분석한 결과 pH 7 및 9에서는 Inconel 600이 Inconel 690에 비해 부식이 잘 되는 것으로 나타난 반면, pH 4에서는 Inconel 690이 부식이 더 잘 되는 것으로 평가되었다. 이러한 경향을 보이는 것은 과도상태의 영향이 과도하게 반영된 것에 기인한 것으로 비교적 정확한 결론을 도출하기 위해서는 장시간의 부식 실험을 수행함으로써 과도상태에 의한 영향을 최소화해야 할 것으로 판단된다.

  • PDF

엔트로피 개념을 이용한 관수로내의 유속분포에 관한 연구 (A Study on The Velocity Distribution in Closed Conduit by Using The Entropy Concept)

  • 추태호;옥치율;김진원;맹승진
    • 대한토목학회논문집
    • /
    • 제29권4B호
    • /
    • pp.357-363
    • /
    • 2009
  • 일반적으로 사용되는 관수로의 평균유속을 구하려면 Darcy-Weisbach의 마찰손실수두공식을 사용하면 되나, 그러나 이 식의 마찰손실계수 f는 Reynolds수와 상대조도(${\varepsilon}$/d)의 함수이므로 사용하기에 매우 불편하며 따라서 보다 편리한 식이 요구된다. 이에 본 연구에서 Chiu 유속공식의 신뢰성과 정확성을 증명하기 위하여 관수로에서 비삽입식 유속측정 장치인 레이저 유속계(Laser Doppler Velocimeter: LDV) 및 초음파 유량계(Ultrasonic Flowmeter: U/F), 삽입식 유속측정장치인 피토관 (Pitot Tube)을 이용하여 실측한 유속측정 자료와 Chiu의 공식을 이용한 유속분포가 매우 잘 일치함을 증명하였다. 유량의 증감에 관계없이 실험실 수로에서의 최대유속과 평균유속간의 이론적인 선형관계를 증명함으로써 관수로내 유속의 평형상태, 즉 엔트로피 파라미터 M값에 대응하는 평형상태에 도달하려 하고 이 평형상태를 지속적으로 유지하려고 하는 경향이 있음을 증명하였다. 또한, 한 단면을 대표하는 엔트로피 파라미터 M값이 결정되면 최대유속이 발생하는 지점에서의 유속 측정만으로 단면 전체의 평균유속을 쉽게 구할 수 있고 이로부터 간단히 유량을 산정할 수 있음을 증명하였으며, 이는 추후 관수로 설계 및 운영관리 시 가장 중요한 평균유량을 측정할 수 있는 이론적인 도구로 사용될 수 있음을 의미하는 것이다.

순환식 유전체 장벽 플라즈마 반응기를 이용한 수중 페놀 처리 (Degradation of Phenol in Water Using Circulation Dielectric Barrier Plasma Reactors)

  • 김동석;박영식
    • 한국환경보건학회지
    • /
    • 제38권3호
    • /
    • pp.251-260
    • /
    • 2012
  • Objectives: The purpose of this study was evaluating the applicability of the circulation dielectric barrier plasma process (DBD) for efficiently treating non-biodegradable wastewater, such as phenol. Methods: The DBD plasma reactor system in this study consisted of a plasma reactor (discharge, ground electrode and quartz dielectric tube, external tube), high voltage source, air supply and reservoir. Effects of the operating parameters on the degradation of phenol and $UV_{254}$ absorbance such as first voltage (60-180 V), oxygen supply rate (0.5-3 l/min), liquid circulation rate (1.5-7 l/min), pH (3.02-11.06) and initial phenol concentration (12.5-100 mg/l) were investigated. Results: Experimental results showed that optimum first voltage, oxygen supply rate, and liquid circulation rate on phenol degradation were 160 V, 1 l/min, and 4.5 l/min, respectively. The removal efficiency of phenol increased with the increase in the initial pH of the phenol solution. To obtain a removal efficiency of phenol and COD of phenol of over 97% (initial phenol concentration, 50.0 mg/l), 15 min and 180 minutes was needed, respectively. Conclusions: It was considered that the absorbance of $UV_{254}$ for phenol degradation can be used as an indirect indicator of change in non-biodegradable organic compounds. Mineralization of the phenol solution may take a relatively longer time than that required for phenol degradation.

메탈핼라이드램프용 순시점등/재점등 전자식안정기 개발 (The Development of Electric Ballast for a Instant Start/Restart of Metalhalide Lamp)

  • 김수경;장우진
    • 조명전기설비학회논문지
    • /
    • 제18권5호
    • /
    • pp.9-15
    • /
    • 2004
  • 메탈핼라이드 램프의 가장 큰 단점중 하나는 아크튜브가 뜨거운 상태에서는 순시 재점등이 불가능하다는 것이다. 메탈핼라이드 램프의 점등중 고온의 아크튜브는 초기 램프가 차가운 상태에서의 방전 전압보다 재점등 방전전압이 높아 재점등 시키는데 압력과 온도가 감소되어지는 약5분정도의 시간이 소요 된다. 만약 램프가 뜨거운 상태에서 재점등시키려면 램프전극 양단에 약20[kV] 이상의 높은 전압펄스를 공급해야한다. 따라서 이러한 목적의 전자식 안정기는 EMII필터, PFC회로, 플라이백 컨버터, 하프브리지 인버터, 고전압 이그나이터 회로로 구성되는데 이것은 순시점등은 물론 램프가 뜨거운 상태에서도 20[kV]의 전압으로 램프를 점등/재점등 할 수 있다.

외부전극 헝광램프의 핀홀 현상 (Pinhole Phenomena in the External Electrode Fluorescent Lamps)

  • 길도현;김상범;송혁수;유동근;이상훈;박민순;강준길;조광섭;조미령;황명근;김영욱
    • 한국진공학회지
    • /
    • 제15권3호
    • /
    • pp.266-272
    • /
    • 2006
  • 외부전극 형광램프의 구동에서 과도한 전력을 인가하면, 외부전극 부분의 유리관 표면에 작은 원형의 구멍(핀홀)이 발생하여 램프가 파손된다. 핀홀은 외부전극과 유리관을 유전층으로 하는 캐패시터의 절연파괴이며, 이러한 절연파괴력은 인가되는 전력에 비례한다. 유전상수가 K인 램프에 흐르는 전류가 작을 때, 핀홀이 발생하는 유리관의 절연파괴 전기장의 세기는 약 3K kV/mm,이다. 이러한 절연파괴 전기장의 세기는 램프에 흐르는 전류가 커질수록 작아진다.

MOSFET를 이용한 X선 신호의 전기적 획득에 관한 연구 (The study for electric readout of X-ray signal using MOSFET)

  • 박성광;강영수;서지현;박지군;남상희
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1998년도 추계학술대회
    • /
    • pp.295-296
    • /
    • 1998
  • With xeroradiography appearance, DR (Digital Radiography) system have been studying for X-ray detection using photoreceptor. Also detection method for receptor charge change have been developing variably. We use photoreceptor material of a-Se(Amorphous Selenium) with high DQE, high SNR(Signal to Noise Ratio) and high transformation efficiency of X-ray signals into electrical signals. After a-Se receptor is uniformly charged by using Arc discharge, X-ray is exposed. Then a-Se receptor produce subtle charge variation and MOSFET detect charge variations. The detected signal pass A/D converter and signal processing by PC. As results, the initial voltage is 8V. It has wide dynamic range needed digital radiography system. In this study, we obtained data with changing kVp(tube potential voltage) and fixed 8mAs(tube current by exposure time) in X-ray system. However MOSFET detector for X-ray signal is not tested X-ray mAs variations. But if MOSFET detector is tested X-ray mAs variation and exactly calibrated multichannel is made and noise-reduction is done, suitable DR system readout method will be done.

  • PDF

LCD 백라이트용 형광램프의 흑화 현상 (Blackening of Inner Glass Surface in Fluorescent Lamps for LCD Backlight)

  • 황하청;정종문;김정현;김동준;봉재환;정재윤;구제환;조광섭
    • 한국진공학회지
    • /
    • 제17권6호
    • /
    • pp.481-486
    • /
    • 2008
  • 나트륨(Na) 함유량이 다른 세 종류의 유리관인 Borosilicate($Na_2O$ 4%), Soda-Lime($Na_2O$ 14%), 그리고 Aluminosilicate($Na_2O$ 0.06%) 유리관의 방전 실험을 통하여 유리관 내벽의 흑화를 관측하였다. 수은 혼합기체(Ne+Ar+Hg)의 방전에서 나트륨 함유량이 많은 유리관일수록 흑화가 심하게 나타난다. 무수은 가스(Ne+Ar)의 방전에서는 흑화가 나타나지 않는다. 나트륨 함유량이 많은 수은 방전 램프에서 봉입 기체의 압력이 작을수록 흑화의 정도가 커진다. 흑화 방지재를 도포한 유리관은 흑화가 미약하게 나타난다. 이 실험을 통하여 흑화는 유리재의 나트륨 성분과 수은 이온의 결합에 의한 아말감($NaHg_2$)이 유리관 내벽에 형성된 것으로 분석된다.

WASTE CLASSIFICATION OF 17×17 KOFA SPENT FUEL ASSEMBLY HARDWARE

  • Cho, Dong-Keun;Kook, Dong-Hak;Choi, Jong-Won;Choi, Heui-Joo
    • Nuclear Engineering and Technology
    • /
    • 제43권2호
    • /
    • pp.149-158
    • /
    • 2011
  • Metal waste generated from the pyroprocessing of 10 MtU of spent fuel was classified by comparing the specific activity of a relevant radionuclide with the limit value of the specific activity specified in the Korean acceptance criteria for a lowand intermediate-level waste repository. A Korean Optimized Fuel Assembly design with a 17${\times}$17 array, an initial enrichment of 4.5 weight-percent, discharge burn-up of 55 GWD/MtU, and a 10-year cooling time was considered. Initially, the mass and volume of each structural component of the assembly were calculated in detail, and a source term analysis was subsequently performed using ORIGEN-S for these components. An activation cross-section library generated by the KENO-VI/ORIGEN-S module was utilized for top-end and bottom-end pieces. As a result, an Inconel grid plate, a SUS plenum spring, a SUS guide tube subpart, SUS top-end and bottom-end pieces, and an Inconel top-end leaf spring were determined to be unacceptable for the Gyeongju low- and intermediate-level waste repository, as these waste products exceeded the acceptance criteria. In contrast, a Zircaloy grid plate and guide tube can be placed in the Gyeongju repository. Non-contaminated Zircaloy cladding occupying 76% of the metal waste was found to have a lower level of specific activity than the limit value. However, Zircaloy cladding contaminated by fission products and actinides during the decladding process of pyroprocessing was revealed to have 52 and 2 times higher specific activity levels than the limit values for alpha and $^{90}Sr$, respectively. Finally, it was found that 88.7% of the metal waste from the 17${\times}$17 Korean Optimized Fuel Assembly design should be disposed of in a deep geological repository. Therefore, it can be summarized that separation technology with a higher decontamination factor for transuranics and strontium should be developed for the efficient management of metal waste resulting from pyroprocessing.