• Title/Summary/Keyword: discharge tube

Search Result 337, Processing Time 0.04 seconds

Transanal Tube Drainage as a Conservative Treatment for Anastomotic Leakage Following a Rectal Resection

  • Shalaby, Mostafa;Thabet, Waleed;Buonomo, Oreste;Di Lorenzo, Nicola;Morshed, Mosaad;Petrella, Giuseppe;Farid, Mohamed;Sileri, Pierpaolo
    • Annals of Coloproctology
    • /
    • v.34 no.6
    • /
    • pp.317-321
    • /
    • 2018
  • Purpose: We evaluate the role of transanal tube drainage (TD) as a conservative treatment for patients with anastomotic leakage (AL). Methods: Patients treated for AL who had undergone a low or an ultralow anterior resection with colorectal or coloanal anastomosis for the treatment of rectal cancer between January 2013 and January 2017 were enrolled in this study. The data were collected prospectively and analyzed retrospectively. The primary outcomes were the diagnosis and the management of AL. Results: Two hundred thirteen consecutive patients, 122 males and 91 females, were included. The mean age was $66.91{\pm}11.15years$, and the median body mass index was $24kg/m^2$ (range, $20-35kg/m^2$). The median tumor distance from the anal verge was 8 cm (range, 4-12 cm). Ninety-three patients (44%) received neoadjuvant therapy for nodal disease and/or locally advanced rectal cancer. Only 13 patients (6%) developed AL. Six patients developed subclinical AL as they had a defunctioning ileostomy at the time of the initial procedure. They were treated conservatively with TD under endoscopic guidance in the endoscopy unit and received intravenous antibiotics. Six weeks after discharge, these 6 patients underwent follow-up flexible sigmoidoscopy which showed a completely healed anastomotic defect with no residual stenosis. Seven patients developed a clinically significant AL and required reoperation with pelvic abscess drainage and Hartmann colostomy formation. Conclusion: These results suggest that TD for management of patients with AL is safe, cheap, and effective. Salvaging the anastomosis will help decrease the need for Hartmann colostomy formation. Proper patient selection is important.

Inactivation of Ralstonia Solanacearum Using Aquatic Plasma Process (수중 Plasma 공정을 이용한 Ralstonia Solanacearum 불활성화)

  • Back, Sang-Eun;Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Science International
    • /
    • v.21 no.7
    • /
    • pp.797-804
    • /
    • 2012
  • A dielectric barrier discharge (DBD) plasma reactor was investigated for the inactivation of Ralstonia Solanacearum which causes bacterial wilt in aquiculture. The DBD plasma reactor of this study was divided into power supply unit, gas supply unit and plasma reactor. The plasma reactor consisted of a quartz dielectric tube, discharge electrode (inner) and ground electrode (outer). The experimental results showed that the optimum 1st voltage, 2nd voltage, air flow rate and pH were for 100 V (1st voltage), 15 kV (2nd voltage), 4 L/min, and pH 3, respectively. At a low 1st voltage, shoulder and tailing off phenomena was observed. The shoulder phenomenon was decreased as the increase of 1st voltage. R. Solanacearum disinfection in the lower air flow rate was showed shoulder and tailing off phenomenon because the active species generated less. Under optimum condition, shoulder and tailing off phenomenon was reduced. When the 2nd voltage was less than 7.5 kV, tailing off phenomenon was observed and this was not vanishes even though the increase of the disinfection time. The inactivation efficiency increased as the increase of air flow rate, however, the efficiency decreased when the air flow rate was above 4 L/min. R. Solanacearum disinfection at pH 3 showed somewhat higher than in pH 11. The pH effect of R. Solanacearum deactivation is less than the impact on other factor.

Analysis of the Dynamic Characteristics of Pressurized Water Discharging System for Underwater Launch using ATP (수중발사를 위한 ATP 방식 압축수 방출시스템의 동특성 해석)

  • Han, Myung-Chul;Kim, Jung-Kwan;Kim, Kwang-Su
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.15 no.6
    • /
    • pp.567-572
    • /
    • 2009
  • The underwater launch system using an ATP consists of five parts: compressor tank, proportional flow control servo valve, expulsion spool valve, air turbine pump, and discharge tube. The purpose of this study is to develop an underwater launch system using an ATP and to verify the validity of the system. The proportional flow control servo valve is modeled as a 2nd order transfer function. The projectile is ejected by pressurized water through the air turbine pump, which is controlled by expulsion valve. The mathematical model is derived to estimate the dynamic characteristics of the system, and the important design parameters are derived by using simulations. The computer simulation results show the dynamic characteristics and the possibility of control for underwater launch system.

Experimental Investigation of Ion Mobility Measurements in Oxygen under Different Gas Pressures

  • Liu, Yun-Peng;Huang, Shi-long
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.852-857
    • /
    • 2017
  • In this paper, measurements of ion mobility were performed in oxygen at gas pressures of 44.52 - 101.19 kPa using the drift tube method. Over this pressure range, mobility values were within the limits of 1.796 to $3.821cm^2{\cdot}V^{-1}{\cdot}s^{-1}$ were determined and ion mobility shown to decrease non-linearly with increasing gas pressure towards a certain level of saturation. Ion mobility measured in air was lower than that measured in oxygen at the same gas pressure. Finally, a parameter correction method for calibrating the relationship between the ion mobility and gas pressure in oxygen was proposed.

Design and Application of Thermal Vapor Compressor for Multi-Effect Desalination Plant (열증기압축기 설계와 MED 담수설비에의 적용)

  • Park, Il-Seok;Park, Sang-Min;Ha, Ji-Soo
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1670-1675
    • /
    • 2004
  • A thermal vapor compressor in which the subsonic/supersonic flow appears simultaneously, has been accurately designed through the CFD analysis for the various shape parameters such as the primary nozzle shape, converging duct shape. mixing tube diameter, and so on. The performance of the developed thermal vapor compressor has been experimentally verified to be installed in a Multi Effect Desalination(MED) plant as an important element, In this paper, the experimental results for Various boundary conditions(motive pressure, suction pressure, and discharge pressure) are presented in comparing with CFD results. The two results show a good agreement with each other within 3.5 % accuracy with regard to the entrainment ratio.

  • PDF

The surface modification on the inner wall of PTFE tube using micro plasma (마이크로 플라즈마 방전을 이용한 PTFE 튜브 내벽의 표면개질)

  • Jo, Yong-Gi;Kim, Hun-Bae;Jeong, Dong-Geun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2013.05a
    • /
    • pp.104-104
    • /
    • 2013
  • 고분자이면서 유전체인 Poly-Tetra-Fluoro-Ethylene (PTFE) 튜브에 AC형 고전압을 인가하여 유전체 장벽 방전 (dielectric barrier discharge, DBD)를 유도하고, 발생된 마이크로 플라즈마에 의한 PTFE 튜브 내벽의 표면 개질에 관한 연구이다. 가스인입과 진공배기가 가능한 장치에 PTFE 튜브를 연결하고, 튜브내부를 진공상태를 유지하면서 반응가스를 이용하여 튜브 내벽을 표면개질 하였다. 반응가스를 아르곤, 수소, 아세틸렌, 산소, 질소를 반응 단계에 맞게 혼입하여 마이크로 플라즈마를 발생시켜 플라즈마에 의한 표면변화를 관찰하였다. 표면은 반응성 가스 플라즈마에 의해 물리 화학적 반응이 일어나 고분자 표면의 반응성 활성화를 통한 표면개질의 방식으로 진행되었다. 표면 개질된 튜브 내벽 표면에 대해 XPS, FT-IR, SEM, 접촉각 측정과 분석 실시함으로써 표면변화를 관찰하였다.

  • PDF

Frontal Sinusitis by Bite Wound in a Dog (교상에 의한 개의 전두동염증의 1례)

  • 최민철;김진구;김태원;김용환;신종욱;원현희;이은주
    • Journal of Veterinary Clinics
    • /
    • v.16 no.1
    • /
    • pp.226-229
    • /
    • 1999
  • A 4-year old male Pitbull terrier dog was presented with a history of nasal discharge of left side and dyspnea for 3 days. This dog had a bitewound on the head due to dog-fighting two weeks ago. There was no abnomality except mild anemic sign on blood examination. Frontal projection of radiographs was taken. This was diagnosed as frontal sinusitis. After skin incision on frontal head, a silicone tube was inserted into the affected frontal sinus. Abscess of the frontal sinus was drainaged and irrigated with saline solution containing trypsin and cephazolin. This patient who also treated with enrofloxacin was recovered completely.

  • PDF

An Optimal Design of LCC Resonant Inverter for Electronic Ballast to Drive HID Lamp (HID 램프를 위한 전자식 안정기의 LCC 공진 인버터의 최적 설계)

  • Park, Chong-Yeun;Jang, Mog-Soon;Lim, Byoung-Noh
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.3
    • /
    • pp.531-537
    • /
    • 2007
  • This paper presents a new method for determining L, Cs, and Cp in a series parallel resonant inverter. This inverter is suitable for driving high-intensity discharge (HID) lamps. The operating frequency is selected to avoid acoustic resonances which are governed by the size and shape of the arc tube. L, Cs and Cp, are chosen to satisfy the ignition and steady state requirements of the lamp. Equations are developed to analyze the starting condition and steady state operating condition of the lamp. For the prototype ballast for a 250W Metal Halide Lamp, experimental results are presented in order to validate the proposed method.

Transient Voltage's Breaking by Development of High Performance SPD (고성능 서지보호기 개발을 통한 과도 이상전압 차단)

  • Kim, Jae-Hoon;Han, Sang-Ok;Kim, Sun-Ho;Koo, Kyung-Wan;Lee, Sei-Hyun;Park, Kang-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.2065_2066
    • /
    • 2009
  • In this paper, we have developed high performance SPD(surge protective device) and evaluated the characteristics in comparison with typical SPD used in the inside and outside of the country. The new SPD was composed of MOV(metal oxide varistor), GDT(gas discharge tube) and impedance such as resistors, capacitors or varistors. To estimate operating the characteristic of the SPD which was developed, it was measured surge voltage caused by fault current or surge according to IEC 61000-4-5. As a result it was found that the power supply was cut off by high performance SPD when caused a short-circuit. In addition we could know that it could prevent ELB(earth leakage breaker)'s malfunction caused by surge.

  • PDF

Electrical and Discharge Charcteristics Analysis of Ceramic Metal Halide Lamp with Operating Method (구동방법에 따른 세라믹 메탈 할라이드 램프의 전기적 및 방전특성 분석)

  • Jang, Hyeok-Jin;Yang, Jong-Kyung;Kim, Nam-Gon;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1623_1624
    • /
    • 2009
  • The use of arc tubes made of ceramic material further enhanced some of the metal halide lamp’s properties. These properties translate into higher efficacy with better color rendering, stable color through lamp long life. Recently, due to an increase in the application of the ceramic metal-halide lamp, the study for the property etc. according to Ballast's driving scheme and the study for arc tube material, optimization of gas and so on are being proceeded to improve the property of the lamp. Especially, to control ceramic metal-halide lamp, the vigorous study and practical use with respect to Electronic Ballast, which has been improved in the disadvantages of the conventional Magnetic Ballast are made. In this paper, Electrical characteristics and gas insulation destroy time are analyzed by comparing magnetic ballast with electronic ballast.

  • PDF