• 제목/요약/키워드: discharge pressure

Search Result 1,478, Processing Time 0.023 seconds

Design of the discharge cleaning system for KSTAR vacuum vessel (KSTAR 제1벽 세정을 위한 방전세정 시스템 설계)

  • Jeong, S.H.;In, S.R.
    • Journal of the Korean Vacuum Society
    • /
    • v.16 no.5
    • /
    • pp.383-387
    • /
    • 2007
  • In this paper the design of the discharge cleaning system for KSTAR vacuum vessel is described. We first discuss about the parameters which are related the efficiency of discharge cleaning. The RG(RF-assisted Glow) discharge which has the ignition and sustain pressure lower than those in the case of DC discharge, thus has the higher efficiency of discharge cleaning. So we adopt the RG discharge, in practical design, for KSTAR discharge cleaning system. For uniformity of the cleaning effect, we plan to install two discharge cleaning systems in A- and I-port of the KSTAR vacuum vessel. The designed system will be adapted for the study of the fuel recycling and of the boronization as well as the discharge cleaning of the KSTAR vacuum vessel.

Lift-Off Voltage and Partial Discharge Characteristics of Free Metallic Particles in GIS (GIS 내 금속입자의 부상전압과 부분방전특성 연구)

  • Yun, Jin-Yeol;Han, Sang-Ok
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.2
    • /
    • pp.127-132
    • /
    • 1999
  • Both motion of free metallic particles from which most GIS internal failures are caused and partial discharges from the particles were examined using EHV GIS test chamber. Effects from particle length and gas pressure which are main factors to lead to breakdown failure were investigated theoretically and experimentally. Magnitude of both lift-off voltage and partial discharge inception voltage were measured respectively and, through these measurements, this paper showed the possibility of predicting breakdown fault and of taking action to prevent the fault in advance. The measurement of partial discharge when the particles began to move could be adopted to decide minimum sensitivity in developing predictive diagnostic equipments. Both the amount of apparent discharge and real discharge in GIS were examined theoretically and experimentally, then experimental results were analyzed on the basis of the theory.

  • PDF

The Characteristics of Frequency Spectrum of Radiated Electromagnetic Waves with AC Discharge Progress in Liquid Nitrogen (액체 질소중 교류방전 진전에 따른 방사전자파의 주파수 스펙트럼 특성)

  • 박광서;윤대희;이상훈;이현동;김충년;최병주;김기채;이광식
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.3
    • /
    • pp.123-129
    • /
    • 2003
  • In this paper, a relationship between AC discharge progress and the radiated electromagnetic waves was investigated by measuring electromagnetic waves using a biconical antenna and a spectrum analyzer. The frequency spectrum of the radiated electromagnetic waves were measured at the atmospheric pressure in liquid nitrogen($LN_2$) during partial discharges progressed by AC high voltage in nonuniform electric field. Front the results of this study, a new method was introduced for measurement and analysis of the radiated electromagnetic waves with discharge progress in $LN_2$ Besides. according to the consideration of the mutual relation between frequency spectrum of the radiated electromagnetic waves and discharge progress, it was confirmed that detecting partial discharge and estimating discharge progress could be possible. It is considered that these results obtained from this investigation may be used as fundamental data for diagnosis and prediction of electric insulations about superconducting and cryogenic power equipments.

A.C Breakdown Characteristics in ${SF}_{6}$ in the Presence of A Small Discharge (미소 방전존재시의 ${SF}_{6}$에 대한 교류절연 파괴 특성)

  • 이광식;이동인;김인식
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.39 no.3
    • /
    • pp.321-328
    • /
    • 1990
  • The effect of a small discharge on the A.C (60Hz) breakdown characteristics in SF6 gas has been studied. Various experiments were investigated while varying distance of the rod-plane electrode, the gas pressure, and the magnitude of the small discharge current. Also, the position of the discharge path was observed for the purpose of evident investigation. As the results of this study, authors clarified the shifting mechanism of the position of discharge path with the ratio Rn (E/N distribution at a certain higher tempera-ture due to the small discharge current to E/N distribution at room temperature, E:electric field strength, N:particle number density). Also, the reason for the reduction of the A.C. breakdown voltage was investigated in the presence of a small discharge current.

  • PDF

Optical Emission Spectroscopy with Parameters During R.F. Discharge of BaTiO3 Target (BaTiO3 타겟의 R.F. 방전 중 변수에 따른 광반사분광 특성)

  • Park, Sang-Shik
    • Korean Journal of Materials Research
    • /
    • v.21 no.9
    • /
    • pp.509-514
    • /
    • 2011
  • In this study, optical emission spectroscopy was used to monitor the plasma produced during the RF magnetron sputtering of a $BaTiO_3$ target. The intensities of chemical species were measured by real time monitoring with various discharge parameters such as RF power, pressure, and discharge gas. The emission lines of elemental and ionized species from $BaTiO_3$ and Ti targets were analyzed to evaluate the film composition and the optimized growth conditions for $BaTiO_3$ films. The emissions from Ar(I, II), Ba(I, II) and Ti(I) were found during sputtering of the $BaTiO_3$ target in Ar atmosphere. With increasing RF power, all the line intensities increased because the electron density increased with increasing RF power. When the Ar pressure increased, the Ba(II) and Ti(I) line intensity increased, but the $Ar^+$ line intensity decreased with increasing pressure. This result shows that high pressure is of greater benefit for the ionization of Ba than for that of Ar. Oxygen depressed the intensity of the plasma more than Ar did. When the Ar/$O_2$ ratio decreased, the intensity of Ba decreased more sharply than that of Ti. This result indicates that the plasma composition strongly depends on the discharge gas atmosphere. When the oxygen increased, the Ba/Ti ratio and the thickness of the films decreased. The emission spectra showed consistent variation with applied power to the Ti target during co-sputtering of the $BaTiO_3$ and Ti targets. The co-sputtered films showed a Ba/Ti ratio of 1.05 to 0.73 with applied power to the Ti target. The films with different Ba/Ti ratios showed changes in grain size. Ti excess films annealed at $600^{\circ}C$ did not show the second phase such as $BaTi_2O_5$ and $TiO_2$.

a-C:H Films Deposited in the Plasma of Surface Spark Discharge at Atmospheric Pressure. Part I: Experimental Investigation

  • Chun, Hui-Gon;K.V. Oskomov;N.S. Sochungov;Lee, Jing-Hyuk;You, Yong-Zoo
    • Journal of Surface Science and Engineering
    • /
    • v.36 no.5
    • /
    • pp.357-363
    • /
    • 2003
  • The aim of this work is the synthesis of a-C:H films from methane gas using surface spark discharge at the atmospheric pressure. Properties of these films have been investigated as functions of energy W delivered per a methane molecule in the discharge. The method enables the coatings to be deposited with high growth rates (up to $100 \mu\textrm{m}$/hour) onto large-area substrates. It is shown that the films consist of spherical granules with diameter of 20∼50 nm formed in the spark channel and then deposited onto the substrate. The best film characteristics such as minimum hydrogen-to-carbon atoms ratio H/C=0.69, maximum hardness $H_{v}$ =3 ㎬, the most dense packing of the granules and highest scratch resistance has been obtained under the condition of highest energy W of 40 eV. The deposited a-C:H coatings were found to be more soft and hydrogenated compared to the diamond-like hydrogenated (a-C:H) films which obtained by traditional plasmaenhanced chemical vapor deposition methods at low pressure (<10 Torr). Nevertheless, these coatings can be potentially used for scratch protection of soft plastic materials since they are of an order harder than plastics but still transparent (the absorption coefficient is about $10^4$$10^{5}$ $m^{-1}$ At the same time the proposed method for fast deposition of a-C:H films makes this process less expensive compared to the conventional techniques. This advantage can widen the application field of. these films substantially.y.

The Electrical Breakdown Characterization of Gas Discharge Tube using Brass Electrode for Surge Protector (과전압 보호용 황동전극 기체방전관의 절연파괴 특성)

  • Kim, Min Il;Jeong, Euigyung;Lee, Sei-Hyun;Lee, Young-Seak
    • Applied Chemistry for Engineering
    • /
    • v.21 no.2
    • /
    • pp.205-210
    • /
    • 2010
  • In this study, a brass electrode gas discharge tube (GDT) was prepared to investigate its discharge characterization, which affects surge protection efficiency and lifetime of GDT. Discharge characterization of GDT using a brass electrode was investigated by changing applied voltage gradient and nitrogen gas pressure inside the GDT. As applied voltage gradient in GDT increased, electrical breakdown voltage and threshold energy largely increased and electrical breakdown time delay decreased. It was found that electrical breakdown voltage, electrical breakdown time delay, and threshold energy were largely decreased with decreasing the nitrogen gas pressure in GDT. As a result, electrical breakdown voltage, electrical breakdown time delay, threshold energy needed to be decreased to increase surge protection efficiency and lifetime. It was also found that the nitrogen gas pressure of GDT influenced strongly the performances as well as life span of it.

Characteristics Analysis of Frequency Spectrum with Pressure Variation of SF6 Gas (압력 변화에 따른 SF6 가스의 주파수 스펙트럼 특성 분석)

  • Yoon, Dae-Hee;Do, Young-Hoe;Song, Hyun-Jik;Kim, Ki-Chae;Park, Won-Ju;Lee, Kwang-Sik
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.6
    • /
    • pp.75-80
    • /
    • 2006
  • The disastrous accident happens and the economic loss comes into being at the power facilities that used a industry site, if the fault comes into being. This paper experiments the partial discharge in the GIS used a $SF_6$ insulation gas by the pressure change. We studied the influence of particles at the partial discharge in a $SF_6$ gas. We use UHF method and measure the partial discharge signal radiation electromagnetic waves and to be happened at the $SF_6$. And we analyzed the influence on the $SF_6$ gas to have the particles which the partial discharge analyzes a spectrum of the radiated electromagnetic waves and comes out. The paper results aided the prevention of breakdown accident that happened by particles when an inside pressure changes at the GIS & the power facilities used $SF_6$ gas.

A Study on Effect of Cylinder Back Pressure on Feed Rate and Delivery Characteristics of Motor-driven Lubricator in a Large Two-stroke Diesel Engine (대형 2행정 디젤기관의 모터구동 주유기 유량 및 송출 특성에 미치는 실린더 배압의 영향에 관한 연구)

  • Bae Myung-whan;Jung Hwa;Ok Hyun-jin
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.13 no.5
    • /
    • pp.19-28
    • /
    • 2005
  • It is of great economic importance to minimize the cylinder wear and the consumption rate of cylinder oil in a large two-stroke diesel engine. The motor-driven cylinder lubricator was first developed fur a large two-stroke marine diesel engine made in $W{\ddot{a}}rtsil{\ddot{a}}a$ Switzerland Ltd. by the joint research of industry-university. In this study, the effects of revolution speed, plunger stroke and cylinder back pressure on maximum discharge and delivery pressures, delivery delay duration, and oil feed rate are experimentally investigated by the home-manufactured cylinder lubricator. The maximum discharge pressure with a spot of 0.03 m and the maximum loss pressure at spots of 5, 6.78 and i 0 m away from the end of lubricator slot are increased as plunger stroke, revolution speed and back pressure are elevated, and the delivery delay duration is shortened as plunger stroke, revolution speed and oil pipe length are increased. Also, oil feed rate is increased as plunger stroke and revolution speed are raised, but lowered as the back pressure is increased.

A Study for Numerical Analysis of Flow Variation on Low Pressure Fuel Pump Fluid using Excavator Engine (굴삭기 엔진용 저압연료펌프 유체의 유동변화에 대한 수치해석적 연구)

  • Lee, IL Kwon;Kim, Seung Chul
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.6
    • /
    • pp.47-53
    • /
    • 2015
  • This paper is to study applying for numerical analysis method for flow field, velocity and pressure of fuel on the low pressure pump using excavator. The pressure distribution of fuel pump certified the linear variation according to rotation angle of rotor. Especially, it knew the fact that the pressure in rotation angle $40^{\circ}$ appeared high outlet and low inlet of fuel pump. Also, this range angle can seek the fact that the leakage flow and velocity are the most increasing. And the more rotor rotation of fuel pump, the more mean outlet flow rate increased in linear. Whenever the gap size decrease with rotor and housing, the discharge flow rate could seek the approaching 0.0712kg/s that consider with theory discharge flow rate calculated from displacement between rotor gear and idle gear.