• 제목/요약/키워드: discharge flow rate

검색결과 755건 처리시간 0.026초

환경개선을 위한 형광방전등형 오존발생기의 특성 (Characteristics of Fluorescent Discharge Lamp Type Ozonizer for Environment Improvement)

  • 박용권;이상근;전병준;송현직;이광식;하장호
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권10호
    • /
    • pp.500-505
    • /
    • 2002
  • In this paper, fluorescent discharge type ozonizer has been designed and manufactured. Ozone discharge and generation characteristics have been investigated in accordance with a sort of internal electrodes, output voltage of power supply, air flow rate and discharge power. Air has been used as the supplied gas of the ozonizer In this paper, when disuse fluorescent lamp was used as an internal electrode. Air flow rate was varied from 2[1/min] to 10[1/min]. The maximum ozone concentration and yield were 3495[ppm] and 23.4[g/kWh] respectively at 2[1/min] air flow rate and 35.2[W] input power. Illumination was appeared as 5[lx] within 15[cm] from external electrode. Whorl fluorescent discharge type ozonizer was used, air flow rate was also varied from 2[1/min] to 10[1/min]. At this moment, the maximum ozone concentration and yield were 2824[ppm] and 21.7[g/kWh] respectively at 2[1/min] air flow rate and 30.5[W] input power. Illumination was also appeared as 5[lx] within 15[cm] from external electrode like used fluorescent lamp.

원자흡수법에 의한 Gas-Jet Assisted RF 글로우방전 시스템의 특성 연구 (Fundamental Studies of Gas-jet Assisted Radio Frequency Glow Discharge Atomic Absorption Spectrometry)

  • 최성규;김효진
    • 분석과학
    • /
    • 제8권1호
    • /
    • pp.69-77
    • /
    • 1995
  • 원자흡수용 gas-jet assisted RF 글로우 방전시스템을 제작하고 시료손실량과 원자흡광도에 미치는 실험변수들에 관한 연구를 수행하였다. 시료손실량과 흡광도는 방전전력, 압력 및 가스흐름에 큰 영향을 받았다. 원자흡광도와 시료손실량을 가스흐름이 600ml/min로 증가할 때 까지 계속 증가하였으며, 방전 압력은 3mbar에서 최대 흡광도를 나타내었다. 방전전력이 증가할수록 시료손실량과 흡광도는 증가하였으나 시스템의 안정도에 영향을 미치는 관계로 적당한 값의 선택이 필요하였다. 스테인리스 스틸 시료 중의 Ni과 황동시료 중의 Cr의 검량선을 작성한 결과 양호한 직선성이 얻어졌다.

  • PDF

다양한 유량 측정기기와 ADCP를 이용한 유량 비교 분석 (Analysis and Comparison of Flow Rate Measurements Using Various Discharge Measuring Instrument and ADCP)

  • 지주연;박승용;이광우;박경민;황순홍;김동호;이영준
    • 한국환경과학회지
    • /
    • 제22권2호
    • /
    • pp.251-257
    • /
    • 2013
  • Discharge data examine the process of hydrologic cycle and used significantly in water resource planning and irrigation and flood control planning. It makes high quality discharge data, they carry out research on standard and method of discharge measurement, and equipment improvement. Now various flow meters are utilized to make discharge data in Korea. However, accuracy of equipment and exprerimental research data from measurement are not enough. ADCP(Acoustic Doppler Current Profiler) have been introduced and utilized for flow measurements since the end of 1980's. ADCP flow method is a formal method for flow measurement can easily applyd to relatively large rivers gradually recognized. This equipment can measure the non-contact three-dimensional velocity and water depth data very quickly and efficiently. Also, spatial and temporal resolution of the data is more accurate than any other flow measurement methods which measure flow rate by velocity - area measurement method. In this paper, the velocity is measured using various flow meter and verified the effectiveness by applying from the ADCP in Geum-river. Various flow meters which are med for discharge measurements are VALEPORT002, FLOW TRACKER, PRICE AA and ADCP. The average of five times flow measurement result by ADCP was $10.412m^3/s$, with a standard deviation of 0.68. The repeat test by ADCP and comparison between ADCP and other flow devices to verify the most import factor, flow measurement accuracy. In the result, repeat test of the ADCP showed similar values, flow values were similar to other velocity device results and the average error is 7.7%.

대기압 플라즈마 제트의 기체 유량에 대한 방전 특성 (Characteristics of Plasma Discharge according to the Gas-flow Rate in the Atmospheric Plasma Jets)

  • 이원영;김동준;김윤중;한국희;유홍근;김현철;진세환;구제환;김도영;조광섭
    • 한국진공학회지
    • /
    • 제22권3호
    • /
    • pp.111-118
    • /
    • 2013
  • 대기압 플라즈마 제트 장치의 유량 변화에 대한 플라즈마 방전 특성을 실험적으로 조사하고 이를 유체역학적으로 해석하였다. 유리관에 주입되는 아르곤 기체의 유량 변화에 대한 레이놀즈 수(Re)로 결정되는 기체 흐름의 형태 변화와 베르누이 정리에 의한 압력 변화가 플라즈마 발생에 영향을 준다. 유리관 내부에 발생하는 플라즈마의 길이 변화의 실험을 통하여, 아르곤 기체에 대한 레이놀즈 수가 Re<2,000이면 층류이고, Re>4,000이면 난류가 형성된다. 이는 일반 유체에서 알려진 결과와 일치한다. 층류에서 유량의 증가로 플라즈마의 길이가 증가한다. 층류와 난류의 전환 영역에서 플라즈마의 길이는 줄어든다. 난류 영역에서는 방전 기체의 흐름이 불규칙함으로서 방전 경로가 흐트러져 플라즈마 칼럼의 길이가 매우 짧아지고 급기야 플라즈마가 소멸된다. 층류에서 주입 유량의 증가로 유리관 내의 유속이 증가하면, 베르누이 정리에 의하여 유리관 내부의 압력이 낮아진다. 관내의 압력이 낮아지면, 파센 법칙에 의하여 관내의 전기장의 세기가 증가하여 방전 전압이 낮아진다. 따라서 주입 유량이 증가하면, 동일한 구동 전압에서 유리관에 발생하는 플라즈마의 길이는 길어진다. 층류의 방전은 유리관 밖에서도 층류의 흐름이 일정 길이로 유지되므로 시료 표면에 조사되는 플라즈마 빔의 직경은 유리관의 직경 이하로 유지된다.

자동차용 양토출 단흡입 워터펌프의 성능 예측에 관한 연구 (A Study on the Performance Prediction of Automotive Water Pump with Double Discharge Single Suction)

  • 허형석;박경석;이기수;원종필
    • 한국자동차공학회논문집
    • /
    • 제12권3호
    • /
    • pp.27-36
    • /
    • 2004
  • A Numerical analysis has been used to predict the performance in the automotive water pump with double discharge single suction. The influence of parameters such as coolant flow rate, rotational speed, ratio of blade height and clearance has been investigated. Also, the prediction of hydraulic performances such as static pressure rise, shaft power, hydraulic power and pump efficiency is carried out on the water pump including an impeller and a volute casing. A full size water pump test bench has been developed to validate the CFD flow model. Discharge flow rate, suction pressure, discharge pressure, rotational speed and torque measurements are provided. Coolant temperature is 8$0^{\circ}C$, water tank pressure is 1 kgf/$\textrm{cm}^2$ and flow rates vary.

흡입공기 온도에 의한 용적형 공기 압축기 성능 변화 (Effect of the Suction Air Temperature on the Performance of a Positive Displacement Air Compressor)

  • 장지성;한승훈;지상원
    • 동력기계공학회지
    • /
    • 제21권2호
    • /
    • pp.89-94
    • /
    • 2017
  • Pneumatic systems are widely applied in various industry because it have a many advantage(low cost, high safety, etc.). Air compressors supply the working fluid to the pneumatic systems and consume a lot of electrical energy at the manufacturing site. The one of the suggested idea is to reduce the energy consumption by reducing the suction temperature of the air compressor and increasing the discharge flow rate. In this paper, the discharge flow rate and air power of the positive displacement type air compressor is simulated by changing the temperature of suction air and the relationship between the suction air temperature and the performance variation of the air compressor is analyzed. As a result, we know that as the suction temperature of air is lowered, the discharge mass flow-rate is increased, but the specific enthalpy is reduced rather than increased, which means that the power of the discharged air is not greatly increased even if lower the suction air temperature.

이중베리어방전을 이용한 $NO_x$ 제거 ($NO_x$Removal by using Double Barrier Discharge)

  • 김동욱;정영식
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제49권1호
    • /
    • pp.37-43
    • /
    • 2000
  • In this experimental study we proposed the double dielectric barrier discharge (DDBD) reactor to produce as high an electric field as possible. The experiment are conducted for applied voltage from 15 to 20[kV], $1~4[\ell/min]$ of gas flow rate and 120[Hz] and 240[Hz] of pulse rate. Superposition discharge(SPD) generated in DDBD which combined the surface discharge with the silence discharge was the most effective to reduce the $NO_x$. In the decomposition efficiency per watt, the low pulse rate gave better efficiency than the high pulse rate. However in DeNOx rate, the high pulse rate gave better performance than the low pulse rate. $NO_x$ removal rate and efficiency increased with increasing the applied voltage in all reactors.

  • PDF

플라즈마 방전에 의한 $SO_x, NO_x$의 분해 (Decomposition of $SO_x, NO_x$ by Plasma Discharge)

  • 우인성;강현춘
    • 한국안전학회지
    • /
    • 제14권1호
    • /
    • pp.73-77
    • /
    • 1999
  • In this study, $SO_2$ and $NO_2$ reduction have been investigated by using coil type plasma reactor. The experiments have been carried out changing discharge power, gas flow rate frequency and electrode style to obtain the decomposition rate. Decomposition rates of $SO_2$ and $NO_2$ were obtained 20~98% at gas flow rate 100ml/min~1,000ml/min and discharge power 5~25w respectively. The energy efficiency is very good at the high frequency power. The decomposition rate of $SO_2$ for 5kHz power supply is only 90%, but for 10kHz power supply is very high, more than 98% for 15w. The decomposition rate is increasing according to the residence time or the power consumption of the discharge. About 15W discharge power for 17$cm^2$ reactor is necessary to obtain the decomposition rate of $SO_2$ and $NO_2$ of more than 85% or 98%. From these experiments, the consumption power of the decomposition rate of 98% in 300ppm $NO_2$ gas in nitrogen gas proved to be 18W and 300ppm $SO_2$ gas to be 15w.

  • PDF

전단동축형 분사기의 유량계수에 대한 형상학적 변수들의 영향 (Effect of Geometrical Parameters on Discharge Coefficients of a Shear Coaxial Injector)

  • 안종현;이근석;안규복
    • 한국분무공학회지
    • /
    • 제25권3호
    • /
    • pp.95-102
    • /
    • 2020
  • Six shear coaxial injectors for a 3 tonf-class liquid rocket engine using oxygen and methane as propellants were designed and manufactured by considering geometric design parameters such as a recess length and a taper angle. Cold-flow tests on the injectors were performed using water and air as simulants. By changing the water mass flow rate and air mass flow rate, the injection pressure drop under single-injection and bi-injection was measured. The discharge coefficients through the injector oxidizer-side and fuel-side were calculated and the discharge coefficient ratio between bi-injection and single-injection was obtained. Under single-injection, the recess served to reduce the injection pressure drop on the injector fuel-side. For the injectors without recess, the discharge coefficients under bi-injection were almost the same as those under single-injection. However, for the injectors with recess, the taper angle and bi-injection had a significant effect on the discharge coefficient.

글로우 방전을 이용한 기체크로마토그라피 검출기 (A Gas Chromatographic Detector using Glow Discharge)

  • 한종수;송승호
    • 대한화학회지
    • /
    • 제35권4호
    • /
    • pp.350-354
    • /
    • 1991
  • 헬리움 흐름에서 글로우 방전을 이원화원으로 사용한 기체 크로마토그라피의 검출기 특성을 연구하였다. 방전전극 사이의 거리가 1 mm 일 때, 400 V/mm 의 전장의 세기 이상에서 10$_6$A 이상의 방전전류가 관찰되었다. 유기물의 검출에는 0.1~0.3 mA의 방전전류가 적당하였다. 순수한 헬리움의 흐름에서는 10 ml/min 이상의 유속에서 방전전류가 거의 일정하였으나, 0~30 ml/min 의 유속에서는 적은양의 유기물의 주입에 의해 방전이 쉽게 사라졌다. 여러 화합물에 따른 방전전류의 감소로부터 글로우 방전 이온화 기체크로마토그라피 검출기의 감도는 그 화합물의 분자량에 크게 영향받음을 알았다.

  • PDF