• 제목/요약/키워드: discharge flow rate

검색결과 755건 처리시간 0.03초

사석마운드 위에 설치되는 조력발전용 수문 케이슨의 통수성능에 대한 실험적 연구 (Experimental Investigation on the Change of Water Discharge Capability of Sluice Caisson for Tidal Power Plant Placed on the Rubble Mound)

  • 이달수;오상호;이진학;박우선;조휴상;엄현민
    • 신재생에너지
    • /
    • 제4권2호
    • /
    • pp.94-104
    • /
    • 2008
  • The change of water discharge capability of sluice caisson for tidal power plant according to installation of the rubble mound was investigated by performing laboratory experiment. The experiment was carried out in an open channel flume with a great care to measure flow rate and water level in the flume accurately. Eight different sluice caisson models were used in the experiment. The water discharge capabilities of seven sluice models decreased with respect to the placement of the rubble mound, while increased for only one sluice model. On average, the values of discharge coefficient decreased by approximately 10% when the sluice models were placed on the rubble mound. It is concluded that the shape of the rubble mound can affect the water discharge capability of the sluice caisson, so that its shape should be significantly considered in the design of the sluice caisson, especially when it is deployed in a site of relatively deeper depth.

  • PDF

전자부품의 친환경 세정공정 적용을 위한 유전체장벽 방전 플라즈마 생성 장치 개발 (Development of the Dielectric Barrier Discharge Plasma Generator for the Eco-friendly Cleaning Process of the Electronic Components)

  • 손영수;함상용;김병인
    • 한국정밀공학회지
    • /
    • 제28권10호
    • /
    • pp.1217-1223
    • /
    • 2011
  • In this paper, the dielectric barrier discharge plasma generator has been studied for producing of the high concentration ozone gas. Proposed plasma generator has the structure of extremely narrow discharge air gap(0.15mm) in order to realize the high electric field discharge. We investigate the performance of the dielectric barrier discharge plasma generator experimentally and the results show that the generator has very high ozone concentration characteristics of 13.7[wt%/$O_2$] at the oxygen flow rate of 1[${\ell}$/min] of each discharge cell. So, we confirmed that the proposed plasma generator is suitable for the high concentration ozone production facility of the eco-friendly ozone functional water cleaning system in the electronic components cleaning process.

코로나 방전에 의한 NOx, $So_2$동시제거에서 첨가제의 영향 (Effect of an Additives on Simultaneous Removal of NOx, $So_2$by Corona Discharge)

  • 박재윤;고용술;이재동;손성도;박상현
    • 한국전기전자재료학회논문지
    • /
    • 제13권5호
    • /
    • pp.451-457
    • /
    • 2000
  • Experimental investigations on the effect of two kinds of additives ; aqueous NaOH solution and ammonia(NH$_3$) for removal of NOx and SO$_2$ simultaneously by corona discharge were carried out. The simulated combustion flue gas was[NO(0.02[%])-SO$_2$(0.08[%])-$CO_2$-Air-$N_2$] Volume percentage of aqueous NaOH solution used was 20[%] and $N_2$flow rate was 2.5[$\ell$/min] for bubbling aqueous NaOH solution Ammonia gas(14.81[%]) balanced by argon was diluted by air. NH$_3$ molecular ratios(MR) based on [NH$_3$] and [NO+SO$_2$] were 1, 1.5 and 2.5 The vapour of aqueous NaOH solution and NH$_3$was introduced to the main simulated combustion flue gas duct through injection systems which were located at downstream of corona discharge reactor. NOx(NO+NO$_2$) removal rate by injecting the vapour of aqueous NaOH solution was much better than that by injecting NH$_3$however SO$_2$removal rate by injecting NH$_3$was much better than that by injecting the vapour of aqueous NaOH SO$_2$removal rate slightly increased with increasing applied voltage. When the vapour of aqueous NaOH solution and NH$_3$were simultaneously injection NOx and SO$_2$ removal rate were significantly increased.

  • PDF

중형버스 다출구 덕트의 최적설계에 관한 해석적 고찰 (A Numerical Analysis on the Optimum Design of a Duct with Multiple Outlets in a Medium Bus)

  • 김민호;천인범;이대훈
    • 한국자동차공학회논문집
    • /
    • 제10권4호
    • /
    • pp.223-233
    • /
    • 2002
  • The air distribution duct with multiple outlets is an essential part of automotive air-conditioning system In a bus. The estimation of airflow rate in an automotive air-conditioning duct is typically very complicate due to large variations in cross-sectional area and abrupt changes in flow direction, as well as unbalanced distribution of the flow. In this paper, the flow characteristic in a duct with multiple outlets is investigated through experiment, CFD simulation and a one-dimensional simulation. Numerical simulations have been performed for two simplified air conditioning ducts with multiple outlets used in a medium bus. The three dimensional Navier-Stokes code was used to evaluate the overall pressure, velocity Held, and distribution rate at each diffuser according to the change of various design parameters such as ratio of cross-sectional area and radius of bifurcated region. In addition, a one-dimensional program based on Bernoulli equation was developed to obtain optimized diffuser area required to equalize discharge flow rate at each outlet. As a result of this study, optimized diffuser area of design variable by one-dimensional program was very reasonable as compared to the trend deduced from CFD Simulation. Therefore, the simple and convenient one-dimensional analysis developed in this study can be applied in practical design procedure for air-conditioning duct.

과불화탄소 제거를 위한 플라즈마 워터젯 스크러버 개발 (Development of a Plasma Waterjet Scrubber for the Reduction of PFCs)

  • 이채홍;전영남
    • 한국대기환경학회지
    • /
    • 제26권6호
    • /
    • pp.624-632
    • /
    • 2010
  • Perfluorocarbons (PFCs) are widely used in semiconductor industry. These gases need to be removed efficiently because of their strong absorption of infrared radiation and long atmospheric lifetimes which cause the global warming effect. To destruct $CF_4$, a waterjet gliding arc plasma was designed and manufactured. The highest $CF_4$ destruction showed at waterjet plasma case, compared to plasma discharge only or water scrubber only, respectively. In addition, it could be known that the $CF_4$ destruction should be associated with the electron and OH radicals. The operating conditions such as waterjet flow rate, initial $CF_4$ concentration, total gas flow rate, specific energy input were investigated experimentally using a plasma waterjet scrubber. Through the parametric studies, the highest $CF_4$ destruction of 94.5% was achieved at 0.2% $CF_4$, 2.1 kJ/L SEI, 20 L/min total gas flow rate and 18.5 mL/min waterjet flow rate.

공동주택의 세대별 균등 배기량을 확보 하는 제어방법에 관한 연구 (Control Method to Ensure Uniform Exhaust Function by Household of Apartment House)

  • 권용일
    • 설비공학논문집
    • /
    • 제29권12호
    • /
    • pp.628-637
    • /
    • 2017
  • This study was conducted to present an effective control method for the common duct system to uniformly discharge volume flow rate exhausted from the kitchen and bathroom of each household in an apartment regardless of the position of household. Since the common duct system is installed vertically and the ventilator is installed in the terminal, the static pressure of each household decreases when vertical height increases. Therefore, the volume flow rate exhausted from each household is different. In order to improve such a phenomenon, a constant air volume damper shall be installed in a branch duct coupled with a common vertical duct system. The selected ventilator should also be able to handle the maximum volume flow rate considering diversity factor. Therefore, a uniform volume flow rate must be exhausted from all households where the hood is operated. This paper mainly focuses on suggestion of an optimum exhaust control method by comparing exhaust performance of each household according to the presence or absence of a constant air volume damper.

워터젯 플라즈마 스크러버 사불화탄소 분해 특성 (Decomposition Characteristics of Tetrafluoromethane Using a Waterjet Plasma Scrubber)

  • 임문섭;전영남
    • 한국기후변화학회지
    • /
    • 제8권1호
    • /
    • pp.63-71
    • /
    • 2017
  • It is recognized that tetrafluoromethane ($CF_4$) has a great influence on global warming. The $CF_4$ is known to have a large impact on climate change due to its large global warming index. In this study, a waterjet plasma scrubber (WPS) was designed and manufactured for the $CF_4$ decomposition. The WPS is a novel technology which is combined a gliding arc plasma and water injection at the center of the plasma discharge. This can give an innovative way for $CF_4$ decomposition by achieving larger plasma columnand generating OH radicals. A performance analysis was achieved for the design factors such as waterjet flow rate, total gas flow rate, consumption electric power, and electrode gap. The highest $CF_4$ decomposition and energy efficiencies were 64.8% and 6.43 g/kWh, respectively; Optimal operating conditions were 20 mL/min of waterjet flow rate, 200 L/min total gas flow rate, 5.3 kW consumption electric power, and 4.4 mm electrode gap. As for the 2 stage reactor of the WPS, the $CF_4$ decomposition efficiency improved as the 85.3% while the energy efficiency decreased as the 5.57 g/kWh.

Effects of Si cluster incorporation on properties of microcrystalline silicon thin films

  • Kim, Yeonwon;Yang, Jeonghyeon;Kang, Jun
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2016년도 추계학술대회 논문집
    • /
    • pp.181-181
    • /
    • 2016
  • Hydrogenated microcrystalline silicon (${\mu}c-Si:H$) films have attracted much attention as materials of the bottom-cells in Si thin film tandem photovoltaics due to their low bandgap and excellent stability against light soaking. However, in PECVD, the source gas $SiH_4$ must be highly diluted by $H_2$, which eventually results in low deposition rate. Moreover, it is known that high-rate ${\mu}c-Si:H$ growth is usually accompanied by a large number of dangling-bond (DB) defects in the resulting films, which act as recombination centers for photoexcited carriers, leading to a deterioration in the device performance. During film deposition, Si nanoparticles generated in $SiH_4$ discharges can be incorporated into films, and such incorporation may have effects on film properties depending on the size, structure, and volume fraction of nanoparticles incorporated into films. Here we report experimental results on the effects of nonoparticles incorporation at the different substrate temperature studied using a multi-hollow discharge plasma CVD method in which such incorporation can be significantly suppressed in upstream region by setting the gas flow velocity high enough to drive nanoparticles toward the downstream region. All experiments were performed with the multi-hollow discharge plasma CVD reactor at RT, 100, and $250^{\circ}C$, respectively. The gas flow rate ratio of $SiH_4$ to $H_2$ was 0.997. The total gas pressure P was kept at 2 Torr. The discharge frequency and power were 60 MHz, 180 W, respectively. Crystallinity Xc of resulting films was evaluated using Raman spectra. The defect densities of the films were measured with electron spin resonance (ESR). The defect density of fims deposited in the downstream region (with nonoparticles) is higher defect density than that in the upstream region (without nanoparticles) at low substrate temperature of RT and $100^{\circ}C$. This result indicates that nanoparticle incorporation can change considerably their film properties depending on the substrate temperature.

  • PDF

자동방류가 가능한 여과형 비점오염처리장치의 운전인자 도출 (Identification of operating parameters in auto-discharging filter system for treatment of urban storm water)

  • 김선희;권은미;박성순;조성주;임채환;강선홍
    • 상하수도학회지
    • /
    • 제24권4호
    • /
    • pp.377-386
    • /
    • 2010
  • To identify operating parameters of the up-flow filtering system, which is available to discharge filtering residue after the rain, developed for treatment of urban storm runoff, lab scale test was carried out. Removal efficiency of SS was 68.7%, 62.2%, and 58.6% at the area roading rate of 2.46m/h, 4.68m/h, and 10m/h, respectively, filtering device is desirable to operate at the lower than 4.68m/h of area roading rate to get higher level of 60% SS removal efficiency. The removal efficiency of SS was 57.1% ~ 68.7% at the raw water SS of 100mg/L ~ 600mg/L, and the SS in treated water was maintained at the constant level through the elapsed time. It is indicate that filtering device can guarantee a certain level of effluent water quality at various raw water quality. The removal efficiency of SS to the depth of filter media was 68.3%, 78.6% at the filter depth of 10 cm, 20cm respectively. The final treated water quality was showed 30.2mg/L of CODMn, 1.60mg/L of TN and 0.25mg/L of TP. The average removal efficiencies by filtering device developed in this research were recorded slightly lower levels than other research. The main reason of these results were the first, the filter depth of the media used in this test was shallow, the second, the kind of filter media in discharge port of residue. More research to kind of filter media, filter packing rate, select of media for residue discharge port should be go on to produce optimum operating condition. The result of this study would be valuable for the application of filtration device to control of urban storm water.

서식지적합도지수(HSI)에 따른 환경생태유량 비교 분석 : 미호천을 중심으로 (Comparative Analysis of Environmental Ecological Flow Based on Habitat Suitability Index (HSI) in Miho stream of Geum river system)

  • 이종진;허준욱
    • Ecology and Resilient Infrastructure
    • /
    • 제9권1호
    • /
    • pp.68-76
    • /
    • 2022
  • 본 연구에서는 금강수계 미호천 유역에서 어류 서식지적합도지수 (HSI)를 산정하고 환경생태유량을 산정하였다. 이를 위해 미호천의 상류와 하류를 대표할 수 있는 2개 지점 (St.3과 St.8)을 선정하고, 어종별 수심과 유속 등 물리적서식지 정보를 구축해 서식지적합도지수를 산정하였다. 서식지적합도지수는 채집된 개체수와 유량조사 결과를 수심과 유속의 관계를 이용해 WDFW 방법으로 산정하였고, 대표어종 선정시 우점종인 피라미 (Zacco platypus)와 유량에 민감한 유영성 어종으로 결정하였다. 단일종인 피라미의 경우 수심 범위는 0.1 - 0.5 m, 유속 범위는 0.2 - 0.5 m/s 이고, 유영성 어종인 경우 수심 범위는 0.2 - 0.5 m, 유속 범위는 0.2 - 0.5 m/s 이다. 미호천의 대표지점인 St.3과 St.8에서 대표어종인 유영성군집 및 피라미에 대한 유량 (Discharge)-가중가용면적 (WUA) 관계 곡선 및 서식지적합도 분포를 모의하였다. 미호천 상류 St.3에서 가중가용면적이 최대값을 나타내는 최적유량은 유영성 군집이 4.0 m3/s, 피라미가 2.7 m3/s 로 모의되었다. 하류지점인 St.8에서는 유영성 군집이 8.8 m3/s, 피라미가 7.6 m3/s 로 모의되었다. 두 지점 모두 유영성군집 어종의 최적유량이 크게 산정되었다. 이는 유영성 군집의 서식지적합도지수가 피라미의 서식조건보다 더 빠른 유속을 필요로 하기 때문이다. 최소유량 산정에서도 피라미의 유량이 더 작고, 보다 더 많은 가중가용면적을 제공하는 것으로 평가된다. 군집 어류의 경우 수심과 유속의 범위를 좁게 산정하면 필요유량이 증가하고 가중가용면적은 상대적으로 감소한다. 따라서 군집어류에 대한 서식지적합도지수 산정시 범위를 좁게 설정하는 것보다 모든 어종의 서식지를 포함하는 지수를 산정하는 것이 유리하다.