• Title/Summary/Keyword: disaster records

Search Result 107, Processing Time 0.027 seconds

Experience of a Disaster Medical Assistant Team activation in the fire disaster at Jecheon sports complex building: limitation and importance of rescue (제천 스포츠복합건물 화재 재난에서의 권역재난의료지원팀 활동 경험 고찰: 한계점과 구조의 중요성)

  • Jung, Seung Gyo;Kim, Yoon Seop;Kim, Oh Hyun;Lee, Kang Hyun;Kim, Kwan-Lae;Jung, Woo Jin
    • Journal of The Korean Society of Emergency Medicine
    • /
    • v.29 no.6
    • /
    • pp.585-594
    • /
    • 2018
  • Objective: This study was designed to report on the progress of the fire at Jecheon sports complex and to assess the adequacy of Disaster Medical Assistant Team (DMAT)'s activities in response to the fire disaster. Methods: We conducted a retrospective review based on camera recordings and medical records that were recorded at the disaster site for assessment of activities. We cooperated with firefighters, police officers, local hospital medical staffs and public health personnel in Jecheon in order to classify patients in the disaster field and to understand the patients' progress. Results: At 15:53, the first request for emergency rescue came to the 119 general emergency call center, and a request for DMAT activation came at 16:28. DMAT arrived at the site at 17:04 and remained active until the following day at 00:43. The total number of casualties was 60, including 27 minimal (Green) patients, 29 expectant (Black) patients, three delayed (Yellow) patients, and one immediate (Red) patient. There were 32 patients who received on-site care by DMAT. Two patients were transferred from a local hospital to Wonju Severance Christian Hospital for hyperbaric oxygen therapy. Conclusion: Twenty-nine victims were found in the sports complex building, and there were 31 mildly to moderately injured patients in this fire disaster. The main cause of death was thought to be smoke suffocation. Although DMAT was activated relatively quickly, it was not able to provide effective activity due to the late rescue and difficulty with fire suppression.

Assessment of Inundation Rainfall Using Past Inundation Records and CCTV Images (CCTV영상과 과거침수기록을 활용한 침수 강우량 평가 - 강남역을 중심으로 -)

  • Kim, Min Seok;Lee, Mi Ran;Choi, Woo Jung;Lee, Jong Kook
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.30 no.6_1
    • /
    • pp.567-574
    • /
    • 2012
  • For the past few years, the video surveillance market has shown a rapid growth due to the increasing demand for Closed Circuit Television(CCTV) by the public sector and the private security industry. While the overall utilization of CCTV in the public and private sectors is expanding, its usage in the field of disaster management is less than sufficient. Therefore, the authors of this study, in an effort to revisit the role of CCTV in disaster situations, have carried out a case analysis in the vicinity of the Gangnam Station which has been designated as a natural disaster-prone area. First, the CCTV images around the target location are collected and the time and depth of inundation are measured through field surveys and image analyses. Next, a rainfall analysis was conducted using the Automatic Weather Station(AWS) data and the past inundation records. Lastly, the authors provide an estimate of rainfall for the areas around the station and suggest viable warning systems and countermeasures. The results from this study are expected to make positive contributions towards a significant reduction of the damages caused by the floods around the Gangnam Station.

Current Status Analysis of Business Units and Retention Period Estimation related to Administrative Information Systems of Public Institutions (공공기관 행정정보시스템 관련 단위과제 및 보존기간 책정 현황분석)

  • Yoon, Sung-Ho;Yu, Sin Seong;Choi, Kippeum;Oh, Hyo-Jung
    • Journal of the Korean BIBLIA Society for library and Information Science
    • /
    • v.31 no.2
    • /
    • pp.139-160
    • /
    • 2020
  • Since the Public Records Management Act was enacted in 2007, the administrative information system has already been included in the electronic records production system, and dataset has been subject to record management as a type of electronic records. With the recent revision of the enforcement decree, dataset records management has been enacted. This study analyzes business units related to administrative information systems of public institutions and examines the current status of retention periods estimation. For this purpose, we collected 36 records classification systems from 49 public institutions among the direct management agencies of the National Archives and disaster management agencies. And we discriminated 824 business units related to administrative information system and divided into large and small groups according to types. We also compared the retention period estimation of records. The problems and improvement plans of this study are expected to be used as basic data in preparing the standard of administrative dataset management in the future.

A Study on the Management Improvement of Disaster Recovery Resources of Municipality with Field Survey (현장실태조사를 활용한 지자체 재난관리자원 관리 개선 연구)

  • Kim, Joon-Ha;Kim, Tae-Heon;Jung, Jae-Wook
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.1
    • /
    • pp.155-162
    • /
    • 2020
  • Purpose: The purpose of study was to identify problems in disaster recovery resource management and operation through on-site investigation and utilize them as improvement proposal for disaster recovery resources management by local governments. Method: Areas with high natural and social disasters recorded in historical and yearly records of natural and social disasters, related books, and annual reports for 20 years were selected. The DRSS data of the selected local governments were analyzed and the reserve warehouse were selected for field survey. Result: It is analyzed that the current situation in the city hall and district offices is somewhat insufficient due to heavy work by the working-level officials of local governments on the storage of disaster recovery resources. The actual amount of stockpiles and DRSS data are somewhat different or missing because the input method and criteria are not clear at present when inputting the current data. Conclusion: To improve the management of the disaster recovery resource reserve, it is deemed that education of DRSS and training of best practices for the operation of disaster management resources are urgently needed, and that a systematic management of stockpiles using disaster prevention experts will be required.

Evaluation of Major Heavy Rain Events in the Annals and Rainfall Records of the Joseon Dynasty using Text Mining (텍스트마이닝을 이용한 조선왕조실록 및 측우기기록에 나타난 주요 호우사상의 평가)

  • Kim, Gwan-Jun;Kim, Soon-Mi;Lee, Dong-Hwan;Chae, Mool-Seok;Jeong, Sang
    • Proceedings of the Korean Society of Disaster Information Conference
    • /
    • 2023.11a
    • /
    • pp.198-199
    • /
    • 2023
  • 본 연구에서는 조선왕조실록을 중심으로 조선시대의 호우 및 홍수기록의 기술방법에 대해 텍스트마이닝 분석을 실시하였다. 조선왕조실록은 조선시대의 큰 호우사상은 모두 포함하고 있기 때문에 이를 일정한 등급으로 나누어 분류한다면 극치 호우 사상의 발생특성을 이해하는데 도움이 될 수 있다. 전체적으로 '큰비'에서와 같이 강우에 대한 언급만이 있는 경우가 '큰물', '홍수', '폭우'와 같이 홍수유출 및 이에 따른 피해가 설명되어 있는 경우보다 강우의 재현기간이 작게 나타나는 것을 파악할 수 있었다. 또 하나 주목할만한 점은 기록된 호우사상이 강우의 총량보다는 강우의 지속기간에 보다 민감하다는 점이다. 즉, 일시에 많은 비가 온 경우보다는 장기간에 걸쳐 내린 호우사상에 보다 초점이 맞추어져 있다는 점이다. 즉, 홍수유출의 크기 및 이에 따른 피해의 정도가 실제 이들 호우사상이 기록으로 남게 되는 원인으로 파악된다.

  • PDF

Development and application of urban flood alert criteria considering damage records and runoff characteristics (피해이력 및 유역특성을 고려한 도시침수 위험기준 설정 및 적용)

  • Cho, Jeawoong;Bae, Changyeon;Kang, Hoseon
    • Journal of Korea Water Resources Association
    • /
    • v.51 no.1
    • /
    • pp.1-10
    • /
    • 2018
  • Recently, localized heavy rainfall has led to increasing flood damage in urban areas such as Gangnam, Seoul ('12), Busan ('13), Ulsan ('16) Incheon and Busan ('17) etc. Urban flooding occurs relatively rapidly compared to flood damage in river basin, and property damage including damage to houses, cars and shopping centers is more serious than facility damage to structures such as levees and small bridges. In Korea, heavy rain warnings are currently announced using the criteria set by KMA (Korea Meteorological Administration). However, these criteria do not reflect regional characteristics and are not suitable to urban flood. So in this study, estimated the flooding limit rainfall amount based on the damage records for Seoul and Ulsan. And for regions that can not estimate the flooding limit rainfall since there is no damage records, we estimated the flooding limit rainfall using a Neuro-Fuzzy model with runoff characteristics. Based on the estimated flooding limit rainfall, the urban flood warning criteria was set. and applied to the actual flood event. As a result of comparing the estimated flooding limit rainfall with the actual flooding limit rainfall, the error of 1.8~20.4% occurred. And evacuation time was analyzed from a minimum of 28 minutes to a maximum of 70 minutes. Therefore, it can be used as a warning criteria in the urban flood.

Detailed Finite Element Analysis of Full-scale Four-story Steel Frame Structure subjected to Consecutive Ground Motions

  • Tagawa, Hiroyuki;Miyamura, Tomoshi;Yamashita, Takuzo;Kohiyama, Masayuki;Ohsaki, Makoto
    • International Journal of High-Rise Buildings
    • /
    • v.4 no.1
    • /
    • pp.65-73
    • /
    • 2015
  • Detailed finite element (FE) analyses of a full-scale four-story steel frame structure, subjected to consecutive 60% and 100% excitations from the JR Takatori records during the 1995 Hyogoken-Nanbu earthquake, are conducted using E-Simulator. The four-story frame was tested at the largest shake-table facility in the world, E-Defense, in 2007. E-Simulator is a parallel FE analysis software package developed to accurately simulate structural behavior up to collapse by using a fine mesh of solid elements. To reduce computational time in consecutive dynamic time history analyses, static analysis with gravity force is introduced to terminate the vibration of the structure during the analysis of 60% excitation. An overall sway mechanism when subjected to 60% excitation and a story mechanism resulting from local buckling of the first-story columns when subjected to 100% excitation are simulated by using E-Simulator. The story drift response to the consecutive 60% and 100% excitations is slightly smaller than that for the single 100% excitation.

A joint probability distribution model of directional extreme wind speeds based on the t-Copula function

  • Quan, Yong;Wang, Jingcheng;Gu, Ming
    • Wind and Structures
    • /
    • v.25 no.3
    • /
    • pp.261-282
    • /
    • 2017
  • The probabilistic information of directional extreme wind speeds is important for precisely estimating the design wind loads on structures. A new joint probability distribution model of directional extreme wind speeds is established based on observed wind-speed data using multivariate extreme value theory with the t-Copula function in the present study. At first, the theoretical deficiencies of the Gaussian-Copula and Gumbel-Copula models proposed by previous researchers for the joint probability distribution of directional extreme wind speeds are analysed. Then, the t-Copula model is adopted to solve this deficiency. Next, these three types of Copula models are discussed and evaluated with Spearman's rho, the parametric bootstrap test and the selection criteria based on the empirical Copula. Finally, the extreme wind speeds for a given return period are predicted by the t-Copula model with observed wind-speed records from several areas and the influence of dependence among directional extreme wind speeds on the predicted results is discussed.

Input energy spectra and energy characteristics of the hysteretic nonlinear structure with an inerter system

  • Wang, Yanchao;Chen, Qingjun;Zhao, Zhipeng;Hu, Xiuyan
    • Structural Engineering and Mechanics
    • /
    • v.76 no.6
    • /
    • pp.709-724
    • /
    • 2020
  • The typical inerter system, the tuned viscous mass damper (TVMD), has been proven to be efficient. It is characterized by an energy-dissipation-enhancement effect, whereby the dashpot deformation of TVMD can be amplified for enhanced energy dissipation efficiency. However, existing studies related to TVMD have mainly been performed on elastic structures, so the working mechanism remains unclear for nonlinear structures. To deal with this, an energy-spectrum analysis framework is developed systematically for classic bilinear hysteretic structures with TVMD. Considering the soil effect, typical bedrock records are propagated through the soil deposit, for which the designed input energy spectra are proposed by considering the TVMD parameters and structural nonlinear properties. Furthermore, the energy-dissipation-enhancement effect of TVMD is quantitatively evaluated for bilinear hysteretic structures. The results show that the established designed input energy spectra can be employed to evaluate the total energy-dissipation burden for a nonlinear TVMD structure. Particularly, the stiffness of TVMD is the dominant factor in adjusting the total input energy. Compared with the case of elastic structures, the energy-dissipation-enhancement effect of TVMD for nonlinear structures is weakened so that the expected energy-dissipation effect of TVMD is replaced by the accumulated energy dissipation of the primary structure.

Countermeasure against Fire Disaster in Regional Heritage Villages on the Concept of ICT-Based Disaster Prevention Design

  • Park, Sun-Gyu;Mishima, Nobuo;Noh, Hwang-Woo;Yoo, Jae-Soo;Oh, Sang-Hoon;Min, Byung-Won;Oh, Yong-Sun
    • International Journal of Contents
    • /
    • v.11 no.1
    • /
    • pp.62-68
    • /
    • 2015
  • Many severe earthquakes have occurred along the main fault lines in the world. In recent years, there has been a high incidence of small- and large-scale earthquakes in our country. These occurrences of earthquakes have become increasingly serious, owing to a degrading earth environment. An earthquake, in general, causes far more serious damages like disruptions in electricity or gas facilities, and fire disasters from its annexed effects than by its vibrations or the shock itself. In this paper, we present a countermeasure and its necessity in safeguarding against fire disasters in regional heritage villages such as "Asan Oeam," "Jeonju Hanok," and "Andong Hahoe." A more systematic and effective strategy for prevention systems against severe fire disasters is proposed after performing various related investigations and analyses of existing domestic and international systems. We investigated the existing fire security systems and their historical records with the tendency of earthquake occurrences in these three folk villages. In this proposal, we present a strategic approach for safeguarding against fire damages in our regional heritage villages derived from ICT (information communication technology)-based DPD (disaster prevention design), after examining the laws and regulations of fire-prevention strategies in Japan, America, and Europe.