• Title/Summary/Keyword: direct to implant

Search Result 161, Processing Time 0.023 seconds

Ectopic Bone Formation Induced By BMP - Fibrous Collagen Membrane Composite (BMP-교원질 섬유막 복합체에 의한 이소성 골형성)

  • Shin, Hong-In;Suh, Jo-Young
    • Journal of Periodontal and Implant Science
    • /
    • v.26 no.1
    • /
    • pp.68-79
    • /
    • 1996
  • To investigate the efficiency of a fibrous collagen membrane(FCM) composed of bovine skin type I atelocollagen as a carrier for BMP, partially purified bovine BMP/FCM($0.3mg/10{\times}5{\times}1mm$) composites were implanted into the dorsal subcutaneous tissue of rats. FCM alone was also implanted as a control. The implants were harvested at 1, 2, 3, and 10 weeks after implantation, then prepared for routine light microscopic observation. The FCM alone did not induce osteogenesis and revealed no specific foreign body reaction nor was there any definite resorptive evidence for 10 weeks after implantation, while the BMP/FCM composites induced favorable bone formation in a process that resembled an endochondral and direct ossification mode. At 10 weeks, the well formed bone confined to embedded collagen fibers revealed hematopoietic marrow between bony trabeculae without evidence of resorptive or degenerative changes . These findings support the suggestion that BMP may induce undifferentiated mesenchymal cells into either chondroblasts or osteoblasts or both independantly according to the chemico- physical characteristics of the carrier, which develops the endochondral and/or direct bone formation process, and suggest that the FCM may be a favorable carrier for BMP.

  • PDF

Investigation of anodized titanium implants coated with triterpenoids extracted from black cohosh: an animal study

  • Park, In-Phill;Kang, Tae-Joo;Heo, Seong-Joo;Koak, Jai-Young;Kim, Ju-Han;Lee, Joo-Hee;Lee, Shin-Jae;Kim, Seong-Kyun
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.1
    • /
    • pp.14-21
    • /
    • 2014
  • PURPOSE. The purpose of this study was to evaluate bone response to anodized titanium implants coated with the extract of black cohosh, Asarum Sieboldii, and pharbitis semen. MATERIALS AND METHODS. Forty anodized titanium implants were prepared as follows: group 1 was for control; group 2 were implants soaked in a solution containing triterpenoids extracted from black cohosh for 24 hours; group 3 were implants soaked in a solution containing extracts of black cohosh and Asarum Sieboldii for 24 hours; group 4 were implants soaked in a solution containing extracts of pharbitis semen for 24 hours. The implants from these groups were randomly and surgically implanted into the tibiae of ten rabbits. After 1, 2, and 4 weeks of healing, the nondecalcified ground sections were subjected to histological observation, and the percentage of bone-to-implant contact (BIC%) was calculated. RESULTS. All groups exhibited good bone healing with the bone tissue in direct contact with the surface of the implant. Group 2 ($52.44{\pm}10.98$, $25.54{\pm}5.56$) showed a significantly greater BIC% compared to that of group 3 ($45.34{\pm}5.00$, $22.24{\pm}2.20$) with respect to the four consecutive threads and total length, respectively. The BIC% of group 1 ($25.22{\pm}6.00$) was significantly greater than that of group 3 ($22.24{\pm}2.20$) only for total length. CONCLUSION. This study did not show any remarkable effects of the extract of black coshosh and the other natural products on osseointegration of anodized titanium implants as coating agents. Further studies about the application method of the natural products on to the surface of implants are required.

Evaluation of 358 Mandibular Poster ior Implants: A 3-year Retrospective Study (하악 구치부위에 식립한 358개 임플란트의 생존율에 대한 3년간 후향적 연구)

  • Yoon, I-Kwon;Lee, Gi;Lee, Dong-Un;Choi, Ju-Young;Yu, Jeong-A;Park, Pil-Gyu;Kim, Jeong-Hee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.1
    • /
    • pp.59-68
    • /
    • 2010
  • Recently, dental implants extensively inserted on edentulous area show highly clinical success rate. However, clinicians cannot exclude the possibility of failure and it often unexpectively occures. Many possible factors associated with failure of dental implants have been reported but controversy exists over the extent to them. In this study, we collected 212 patients who had been inserted 358 dental implants on mandibular premolar and molar area from 2005 to 2006. The survival rate of fixtures was recorded according to age of patients, implantation site, implant system, diameter and length of fixtures. Multi-variable analysis using SPSS chi-square test was operated to verify relation of each factors and survival rates. Accumulative survival rate was 98.3% for 3 years. Only diameter of fixtures was related to the implant survival rate. This may be thought that wider fixtures had been chosen to rescue implants or used in sites of poor bone quality. Further continuous study will be needed for direct guidance associated with survival rate of implants.

A study of Physically Implanted Surface Islands by direct Nd:YAG Laser Beam Irradiation

  • Oh, Chang-Heon;Cheon, Suyoung;Lim, Changjin;Lee, Jeongjun;Jeon, Jihyun;Kim, Kyoung-Kook;Chung, Chan-Moon;Cho, Soohaeng
    • Applied Science and Convergence Technology
    • /
    • v.26 no.4
    • /
    • pp.66-69
    • /
    • 2017
  • Physically implanted surface islands of Nano Carbon Tube (NCT) and ${\alpha}-F_2O_3$ particles have been produced on Al-doped ZnO (AZO)/glass surfaces by simple and direct ND:YAG laser beam irradiation. Sheet resistance of the reconstructed surface increased by about 3.6% of over AZO. Minimal surface damage can be repaired by ND:YAG laser beam irradiation in conjunction with proper impurities. Implanted islands of NCT, which are considered to be a good conductive impurity, on AZO increased the sheet resistance by about 1.8%, while implanted islands of ${\alpha}-F_2O_3$, an insulating impurity, on AZO increased sheet resistance by about 129% compared with a laser beam treated AZO. This study provides insight regarding surface implantations of nanowires and micro-circuits, doping effects for semiconductors and optical devices, surface area and impurity effects for catalysis.

Development of Implantable Blood Pressure Sensor Using Quartz Wafer Direct Bonding and Ultrafast Laser Cutting (Quatrz 웨이퍼의 직접접합과 극초단 레이저 가공을 이용한 체내 이식형 혈압센서 개발)

  • Kim, Sung-Il;Kim, Eung-Bo;So, Sang-kyun;Choi, Jiyeon;Joung, Yeun-Ho
    • Journal of Biomedical Engineering Research
    • /
    • v.37 no.5
    • /
    • pp.168-177
    • /
    • 2016
  • In this paper we present an implantable pressure sensor to measure real-time blood pressure by monitoring mechanical movement of artery. Sensor is composed of inductors (L) and capacitors (C) which are formed by microfabrication and direct bonding on two biocompatible substrates (quartz). When electrical potential is applied to the sensor, the inductors and capacitors generates a LC resonance circuit and produce characteristic resonant frequencies. Real-time variation of the resonant frequency is monitored by an external measurement system using inductive coupling. Structural and electrical simulation was performed by Computer Aided Engineering (CAE) programs, ANSYS and HFSS, to optimize geometry of sensor. Ultrafast laser (femto-second) cutting and MEMS process were executed as sensor fabrication methods with consideration of brittleness of the substrate and small radial artery size. After whole fabrication processes, we got sensors of $3mm{\times}15mm{\times}0.5mm$. Resonant frequency of the sensor was around 90 MHz at atmosphere (760 mmHg), and the sensor has good linearity without any hysteresis. Longterm (5 years) stability of the sensor was verified by thermal acceleration testing with Arrhenius model. Moreover, in-vitro cytotoxicity test was done to show biocompatiblity of the sensor and validation of real-time blood pressure measurement was verified with animal test by implant of the sensor. By integration with development of external interrogation system, the proposed sensor system will be a promising method to measure real-time blood pressure.

Characterion of Calcium Phosphate Films Grown on Surgicl Ti-6AI-4V By Ion Beam Assisted Deposition

  • Lee, I-S.;Song, J-S.;Choi, J-M;Kim, H-E.
    • Journal of the Korean Vacuum Society
    • /
    • v.7 no.s1
    • /
    • pp.30-36
    • /
    • 1998
  • The plasma-spray technique is currently the most frequently used method to produce calcium phosphate coatings. Hydroxyapatite(HAp), one form of calcium phosphate, is preferred by its ability to form a direct bond with living bone, resulting in improvements of implant fixation and faster bone healing. Recently, concerns have been raised regarding the viable use and long-term stability of plasma-spray HAp coatings due to its nature of comparatively thick, porous, and poor bonding strength to metal implants. Thin layers (maximum of few microns) of calcium phosphate were formed by an e-beam evaporation with and without ion bombardments. The Ca/P ration of film was controlled by either using the evaporants having the different ration of Ca/P with addition of CaO, or adjusting the ion beam assist current. The Ca/P ration had great effects on the structure formation after heat treatment and the dissolution bahavior. The calcium phosphate films produced by IBAD exhibited high adhesion strength.

  • PDF

Hybrid Prosthesis Supported by Osseointegrated Implants in Maxilla (골유착성 임프란트에 의해 지지되는 새로운 설계의 Hybrid Prosthesis)

  • Lee, J.S.;Shin, S.W.
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.8 no.1
    • /
    • pp.46-59
    • /
    • 1999
  • A fixed bridge is preferred as a prosthetic option supported by oral implants. However, it is very difficult to re tore edentulous maxilla with fixed prosthesis in cases with improper position and angulation of fixtures, abnormal jaw relation, and need for proper lip support. Six Br${\aa}$nemark implants were installed in edentulous maxilla opposing mandible with natural dentition. A removable hybrid prosthesis attached to a bar milled by 6 degrees was therefore designed to overcome such disadvantages of fixed prosthesis. Lateral stabilization of removable prosthesis was obtained by framework closely fitting the milled bar. Support for the prosthesis was ensured by three elevated areas on the bar. Two precision attachments(CEKA REVAX) provided appropriate direct and indirect retention without influencing support. A clinical and laboratory procedure was presented.

  • PDF

Chronic Desquamative Gingivitis (만성 박리성 치은염)

  • Yoon, Jung-Hoon;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.30 no.3
    • /
    • pp.631-639
    • /
    • 2000
  • Desquamative gingivitis is characterized by a diffuse erythema of the free and attached gingiva associated with areas of vesiculation, erosion, and desquamation. Desquamative gingivitis is not a distinct disease entity but represents a reaction pattern of the gingiva to various stimuli. Pemphigus vulgaris, cicatricial pemphigoid, and lichen planus may presents as desquamative gingivitis. We observed 3 patients whose disease was limited to the gingiva, and studied them by light and direct immunofluorescence microscope. We classified them according to clinical, histologic, and immunopathologic observations. Identification of the underlying causes of desquamative gingivitis is of utmost importance and is dependent upon clinical, histologic, and immunologic criteria.

  • PDF

The bactericidal effect of an atmospheric-pressure plasma jet on Porphyromonas gingivalis biofilms on sandblasted and acid-etched titanium discs

  • Lee, Ji-Yoon;Kim, Kyoung-Hwa;Park, Shin-Young;Yoon, Sung-Young;Kim, Gon-Ho;Lee, Yong-Moo;Rhyu, In-Chul;Seol, Yang-Jo
    • Journal of Periodontal and Implant Science
    • /
    • v.49 no.5
    • /
    • pp.319-329
    • /
    • 2019
  • Purpose: Direct application of atmospheric-pressure plasma jets (APPJs) has been established as an effective method of microbial decontamination. This study aimed to investigate the bactericidal effect of direct application of an APPJ using helium gas (He-APPJ) on Porphyromonas gingivalis biofilms on sandblasted and acid-etched (SLA) titanium discs. Methods: On the SLA discs covered by P. gingivalis biofilms, an APPJ with helium (He) as a discharge gas was applied at 3 different time intervals (0, 3, and 5 minutes). To evaluate the effect of the plasma itself, the He gas-only group was used as the control group. The bactericidal effect of the He-APPJ was determined by the number of colony-forming units. Bacterial viability was observed by confocal laser scanning microscopy (CLSM), and bacterial morphology was examined by scanning electron microscopy (SEM). Results: As the plasma treatment time increased, the amount of P. gingivalis decreased, and the difference was statistically significant. In the SEM images, compared to the control group, the bacterial biofilm structure on SLA discs treated by the He-APPJ for more than 3 minutes was destroyed. In addition, the CLSM images showed consistent results. Even in sites distant from the area of direct He-APPJ exposure, decontamination effects were observed in both SEM and CLSM images. Conclusions: He-APPJ application was effective in removing P. gingivalis biofilm on SLA titanium discs in an in vitro experiment.

Accessory mental foramen: A rare anatomical variation detected by cone-beam computed tomography

  • Torres, Marianna Guanaes Gomes;Valverde, Ludmila De Faro;Vidal, Manuela Torres Andion;Crusoe-Rebello, Ieda Margarida
    • Imaging Science in Dentistry
    • /
    • v.45 no.1
    • /
    • pp.61-65
    • /
    • 2015
  • The mental foramen is a bilateral opening in the vestibular portion of the mandible through which nerve endings, such as the mental nerve, emerge. In general, the mental foramen is located between the lower premolars. This region is a common area for the placement of dental implants. It is very important to identify anatomical variations in presurgical imaging exams since damage to neurovascular bundles may have a direct influence on treatment success. In the hemimandible, the mental foramen normally appears as a single structure, but there are some rare reports on the presence and number of anatomical variations; these variations may include accessory foramina. The present report describes the presence of accessory mental foramina in the right mandible, as detected by cone-beam computed tomography before dental implant placement.