• Title/Summary/Keyword: direct test

Search Result 3,324, Processing Time 0.04 seconds

Shear Behavioral Characteristics of Weathered Residual Soil for the Change Water Content (풍화잔적토의 함수비 변화에 따른 전단거동특성)

  • Yoo, Nam-Jae;Kim, Young-Gil;Lee, Jong-Ho
    • Journal of Industrial Technology
    • /
    • v.17
    • /
    • pp.119-124
    • /
    • 1997
  • This thesis is an experimental research of shear behavioral characteristics and shear behavioral coefficient of weathered residual soil which is mostly contained in soil of Korea. Using the weathered residual soil from mountain near Kangwon National University, this experimental research were contained the physical properties of sample in term of the basic test method such as specific gravity, plastic and liquid limit, grain-size distribution, density and water content. Experimental results obtained from direct shear test sand triaxial compression tests show that according to step loading, linear strain and linear stress increase continually and angle of internal friction decreases just little according to incresing of water content in case of ignoring the cohesion, and angle of internal friction appears the maximum angle near a optimum moisture content in case of considering the cohesion.

  • PDF

A Study On The Arc Resistance of $SF_6$ Gas Circuit Breaker ($SF_6$ 가스차단기의 아크저항에 관한 연구)

  • Chong, Jin-Kyo;Lee, Woo-Young;Kim, Gyu-Tak
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.9
    • /
    • pp.1566-1570
    • /
    • 2007
  • [ $SF_6$ ] gas circuit breakers are widely used for short circuit current interruption in EHV(Extra High Voltage) or UHV(Ultra High Voltage) power systems. To develop $SF_6$ gas circuit breakers, the arc resistance value is necessary to compare experimental results to numerical ones. The arc resistance value can be obtained from a breaking test with a $SF_6$ gas circuit breaker. The direct testing or synthetic testing facility is widely used to verify the breaking ability for $SF_6$ gas circuit breakers. We employed the simplified synthetic testing facility to test a $SF_6$ gas circuit breaker prototype. The arc resistance characteristic was measured and calculated under the various experimental conditions. This arc resistance value can be used for verifying the numerical results from arc simulation in a circuit breakers.

An Experimental Study on Oil Combustion Technology with High Temperature Preheated Air (고온공기이용 오일 연소기술)

  • 김원배;양제복
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2002.11a
    • /
    • pp.17-23
    • /
    • 2002
  • The objective of this study is to develop a new oil combustion technology concerning industrial furnaces and kilns, not only to save energy but also to reduce environmental emissions. Of many kinds of such technologies we chose the high temperature air combustion technology which was initiated by the British steel company in '80s and developed further by the American burner company "North American". In this study it was carried out to test regenerative burner experimentally and to have an applicability to industry. From the variation of configuration of gas nozzle and hot test on the temperature distribution and NOx, it was found out that the reduction of NOx was due to the effect of internal gas recirculation, which will be caused by air emitting velocity from burner nozzle.

  • PDF

Development and characterization of graphite reinforced conductive polymer composites for PEMFC bipolar plates (고분자전해질 연료전지용 흑연계 복합소재 분리판 개발)

  • Heo Seongil;Yun Jincheol;Oh Kyeongseok;Han Kyungseop
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.248-251
    • /
    • 2005
  • Graphite reinforced conductive polymer composites for PEMFC bipolar plates were fabricated by the compression molding technique. Graphite powder was mixed with an phenol resin to impart electrical property in composites. In this study, conductive polymer composites with high filler $loadings(>60wt.\%)$ were manufactured to accomplish high electrical conductivity above 100S/cm. The level of compaction is important because graphite powder increase electrical conductivity of composites by direct physical contact between particles. The optimum molding pressure according to filler was proposed experimentally. Various tests(electrical conductivity, flexural strength, compressive strength, leach test, etc) were carried out to verify the performance of fabricated composites for PEMFC bipolar plates. Fabricated composites have good electrical conductivity and mechanical strength. The results of leach test and contact angle measurement showed similar characteristics compared with commercial bipolar plates.

  • PDF

Bending Performance of Bacterial Cellulose Actuator under Water (수중에서 박테리아 셀룰로오스 작동기의 굽힘 성능)

  • Jeon, Jin-Han;Park, Min-Woo;Kim, Seong-Jun;Kim, Jae-Hwan;Oh, Il-Kwon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.203-204
    • /
    • 2008
  • Bacterial Cellulose Actuator with biocompatible and biodegradable properties was newly developed as an electro-active biopolymer under water. The performance of the BC actuator was improved through Li treatment. The mechanical and chemical properties of BC membranes were measured such as the tensile test, proton conductivity. The surface morphology of the bacterial cellulose was observed by using SEM. The electromechanical bending responses under both direct current and alternating current excitations were investigated. In voltage-current test,the power consumption under dynamic excitation increases with increasing voltage. Present results show that the bacterial cellulose actuator can be a promising smart material and may possibly have diverse applications under water.

  • PDF

Measurement of Material Deformation Using Laser Speckle (레이저 스페클을 이용한 재료 변형 측정)

  • 전문창;강기주
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.688-694
    • /
    • 2002
  • As a tool for strain measurement to work with screw driven or hydraulic material test systems, in which mechanical vibration is inherent, SSDG(Speckle Strain/Displacement Gage), ESP(Electronic Speckle Photography) and its 3-dimension version SDSP are investigated for the theory and practical appliance. Through tension test of steel strips, their validity and shortcomings are examined. As the results, it has been shown that, although SSDG and ESP provide direct measurement of in-plane strain in one direction, they are so sensitive to the out-plane displacement. On the other hand, SDSP which is aided with DIC (Digital Image Correlation) technique to trace the movement of the speckles provides not only in-plane 2-dimensional displacement field, but also out-of-plane displacement simultaneously. However, because the DIC is time-consuming, not automated yet and it needs post-processing to evaluate strain from the displacement field, SDSP appears to be not adequate as a real time sensor.

  • PDF

A Study of Consolidation Characteristics of Constant Rate of Strain Consolidation tests with Rates of Strain (변형률속도에 따른 일정변형률시험의 압밀특성 비교연구)

  • 장병욱;차경섭;원정윤
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1998.10a
    • /
    • pp.455-460
    • /
    • 1998
  • This study performed to establish tile characteristics of constant rate of strain consolidation(CRSC) tests. The values obtained by the CRCS tests were compared with oedometer tests. From the comparision of the results of oedometer and CRSC tests for soft soil from Haenam, Korea, it was concluded that. 1. When rate of strain is 0.9mm/hr, compression curve of CRSC test was not coincided with those of tile oedometer test, then preconsolidation stress was larger than those of other rates of strain. 2. Permeabilities from CRSC tests and direct measurements were about same each other, but permeabilities from Oedometer tests were large than those from others.

  • PDF

Inhibitory Effect of Linolenic Acid on the Mutagens-Induced Mutagenicities in Ames Assay System and SOS Chromotest (Ames 실혐계 및 SOS Chromotest에서 Linolenic acid의 돌연변이유발 억제효과)

  • 임선영;이슥희;박건영
    • Journal of Life Science
    • /
    • v.5 no.3
    • /
    • pp.121-125
    • /
    • 1995
  • To determine whether the omega 3 family, linolenic acis(LnA) is effective to inhibit carcinogens/mutagens-induced mutagenesis, we employed the Ames test using Salmonella typhimurium strain of TA100 and the SOS chromotest using Escherichia coli PQ37 strain. The inhibitory effect of LnA shown in the Ames assaying system was 95%, 78% and 73% when the mutagenicities were mediated by AFB$_{1}$, MNNG and 4-NQO, respectively. LnA shows a strong antimutagenic activity against indirect mutagen of AFB$_{1}$, whereas the same concentration of LnA exhibited weaker inhibitory effects on the direct mutagen of MNNG and 4-NQO than that of AFB$_{1}$. However. LnA reduced more than 80% of SOS responses induced by MNNG and 4-NQO when the adding concentration increased to 5%. We conclude that LnA contains in vitro antimutagenic properties and that this finding warrants further investigation both in vitro and in vivo to assess its possible chemotherapeutic potential.

  • PDF

An Experimental Study on the Bond Failure Behavior between Parent Concrete and CFM (콘크리트와 탄소섬유메쉬의 부착파괴 거동에 관한 실험적 연구)

  • 오재혁;성수용;한병찬;윤현도;서수연;김태용
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.05a
    • /
    • pp.965-970
    • /
    • 2002
  • The strengthening of concrete structures in situ with externally bonded carbon fiber is increasingly being used for repair and rehabilitation of existing structures. Carbon fiber is attractive for this application due to its good tensile strength, resistances to corrosion, and low weight. Generally bond strength and behavior between concrete and carbon fiber mesh(CFM) is very important, because of the enhanced bond of CFM. Therefore if bond strength is sufficient, it will be expected to enhance reinforcement effect. If insufficient, reinforcement effect can not be enhanced because of bond failure between concrete and CFM. This study is to investigate the bond strength of CFM to the concrete using direct pull-out test and tensile-shear test. The key variables of the experiment are the location of clip, number of clips and thickness of cover mortar. The general results indicate that the clip anchorage technique for increasing bond strength with CFM appear to be effective to maintain the good post-failure behavior.

  • PDF

Tensile Strength Characteristics of Steel Cord and PVA Hybrid Fiber Reinforced Cement-Based Composites (Steel Cord와 PVA 혼합섬유 보강 고인성 시멘트 복합체의 인장강도 특성)

  • Yun Hyun Do;Yang Il Seung;Han Byung Chan;Hiroshi Fukuyama;Cheon Esther;Moon Youn Joon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.18-21
    • /
    • 2004
  • This paper discusses how steel cord and PVA hybrid fibers enhance the performance of high performance fiber reinforced cementitious composites (HPRFCC) in terms of elastic limit, strain hardening response and post peak of the composites. The effect of microfiber(PVA) blending ratio is presented. For this purpose flexure, direct tension and split tension tests were conducted. It was found that HFRCC specimen shows multiple cracking in the area subjected to the greatest bending tensile stress. Uniaxial tensile test confirms the range of tensile strain capacity from 0.5 to $1.5\%$ when hybrid fiber is used. The cyclic loading test results identified a unique unloading and reloading response for this ductile composite. Cyclic loading in tension appears not to affect the tensile response of the material if the uniaxial compressive strength during loading is not exceeded.

  • PDF