• Title/Summary/Keyword: direct test

Search Result 3,324, Processing Time 0.081 seconds

The Automated Measurement of Tool Wear using Computer Vision (컴퓨터 비젼에 의한 공구마모의 자동계측)

  • Song, Jun-Yeop;Lee, Jae-Jong;Park, Hwa-Yeong
    • 한국기계연구소 소보
    • /
    • s.19
    • /
    • pp.69-79
    • /
    • 1989
  • Cutting tool life monitoring is a critical element needed for designing unmanned machining systems. This paper describes a tool wear measurement system using computer vision which repeatedly measures flank and crater wear of a single point cutting tool. This direct tool wear measurement method is based on an interactive procedure utilizing a image processor and multi-vision sensors. A measurement software calcultes 7 parameters to characterize flank and crater wear. Performance test revealed that the computer vision technique provides precise, absolute tool-wear quantification and reduces human maesurement errors.

  • PDF

The Design of a Direct Driving Gimbal System Using the DSP(TMS320F240) Controller and the Gyroscope (DSP제어기, 자이로센서를 이용한 GIMBAL시스템 설계)

  • 류정오;최중경;최승진;안기호;박성수
    • Proceedings of the IEEK Conference
    • /
    • 2001.06e
    • /
    • pp.139-142
    • /
    • 2001
  • This paper presents a design of two gimbal system. One is two axes stabilized platform that is targeted to preserve direction while vehicle that is adhered antiaircraft fire, radar or EOTS is moving. The system maintains stabilization by recovering error using the rate gyro. The other is three axes gimbal system that is intended to simulate various angle movement in space and to test three axes gyroscope. This system determines gyro condition comparing gyro output value with converted motor encoder value.

  • PDF

Parental Controls and Antisocial Behavior of Children (부모의 통제유형과 자녀의 반사회적 행동과의 관계)

  • Kim, Sun Ae;Kim, Joon Ho
    • Korean Journal of Child Studies
    • /
    • v.16 no.2
    • /
    • pp.49-63
    • /
    • 1995
  • The purpose of the present study was to investigate effective parental controls by age of child. The subjects participating in this study were 10, 12, 15, and 18-year-old school boys residing in Seoul. A total of 1,468 boys was used in the final analysis. Factor analysis and multiple regression of SPSS $PC^+$ were utilized to test the hypotheses. The findings of the analysis showed that the impact of various parental controls on antisocial behavior varied with developmental stages of the children. Younger boys were more susceptible to direct controls, while indirect controls proved more effective for older youngsters.

  • PDF

BOUNDARY ELEMENT TECHNIQUE IN TORSION PROBLEMS OF BEAMS WITH MULTIPLY CONNECTED CROSS-SECTIONS

  • TEMIS, Y.M.;KARABAN, V.V.
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.5 no.2
    • /
    • pp.39-51
    • /
    • 2001
  • This paper shows how boundary element method can be used to calculate torsion geometrical stiffness of cross-sections of various beams and airfoil profiles. Using the BEM direct formulation, the technique for determining bending and torsional geometrical characteristics of arbitrary multiply connected cross-sections is presented. The application limits of several well-known formulae on some test problems have been demonstrated and discused.

  • PDF

IGBT explosion test (IGBT 폭파시험)

  • Jeong, Jong-Kyou;Seo, Dong-Woo;Jung, Hong-Ju
    • Proceedings of the KIPE Conference
    • /
    • 2019.07a
    • /
    • pp.350-351
    • /
    • 2019
  • High Voltage Direct Current (HVDC) 시스템은 고압 직류 송전을 위한 시스템이다. 고압 직류 송전을 위해서는 전력변환기가 교류전력을 직류전력으로 변환해주어야 하는데, 최근에는 모듈형 멀티레벨 컨버터(Modular Multilevel Converter, MMC)가 많이 적용되고 있다. 모듈형 멀티레벨 컨버터는 단위 서브모듈이 직렬로 구성되어야 하는데 기구적으로 하나의 밸브 구조물에 6개의 서브모듈이 일정한 간격을 두고 위치하게 된다. 모듈형 멀티레벨 컨버터의 특징 중에 하나는 예비모듈이 구성되어 가용율을 높일 수 있다는 것이다. 본 논문에서는 서브모듈의 IGBT 폭파에 의해 발생되는 플라즈마가 주변 서브모듈에 도달해 절연파괴를 발생시키는지 확인하였다.

  • PDF

Characterization Test of Sub-Modules for High Voltage DC Transmission System-Based Modular Multi-Level Converter (고압 직류송전망을 위한 모듈형 멀티레벨 컨버터의 서브모듈 특성시험)

  • Seo, Dong-Woo;Jeong, Jong-Kyou;Jung, Hong-Ju
    • Proceedings of the KIPE Conference
    • /
    • 2019.07a
    • /
    • pp.344-345
    • /
    • 2019
  • High Voltage Direct Current (HVDC) 시스템은 고압 직류 송전을 위한 시스템으로서 단위 유닛인 서브모듈로 구성된 모듈형 멀티레벨 컨버터 구조를 갖는다. 서브모듈의 신뢰성 확보 및 설계 검증은 HVDC 시스템의 성능과 효율, 크기를 결정짓는 중요한 요소이다. 본 논문에서는 (주)효성이 개발하는 200MW 모듈형 멀티레벨 컨버터 서브모듈의 성능을 검증하기 위한 특성시험을 나타낸다. 특성시험을 통해서 개발 중인 서브모듈의 성능과 보호동작을 검증한다.

  • PDF

On The Derivation of a Certain Noncentral t Distribution

  • Gupta, A.K.;Kabe, D.G.
    • Journal of the Korean Statistical Society
    • /
    • v.19 no.2
    • /
    • pp.182-185
    • /
    • 1990
  • Let a p-component vector y have a p-variate normal distribution $N(b\theta, \Sigma), \Sigma$ unknown, b specified, then for testing $\theta = 0$ against general $\theta$, Khatri and Rao (1987) derive a certain t test and obtain its power function. This paper presents a direct derivation of this power function in terms of the original variates unlike Khatri and Rao (1987) who resort to the canonical transformations of the original variates and the conditional distributions.

  • PDF

Constructing a Questionnaire on Male Workers' Sobriety Behavior - Based on Ajzen's Theory of Planned Behavior - (남성 직장인의 절주행위 측정도구 개발 -Ajzen의 계획적 행위 이론 적용-)

  • Park, In-Hyae;Kim, Youn-Kyoung
    • Research in Community and Public Health Nursing
    • /
    • v.21 no.2
    • /
    • pp.156-168
    • /
    • 2010
  • Purpose: The purpose of this study was to construct a questionnaire to assess male workers' sobriety behavior based on Ajzen's Theory of Planned Behavior (TPB). Methods: A primary questionnaire with 56 questions was constructed based on literature review and structured interview with male workers. The Content Validity Index (CVI) was evaluated by a group of experts, construct validity was tested by principle component analysis, and reliability was evaluated by Cronbach's ${\alpha}$ and the test-retest reliability test. Results: Fifty two questions showed higher than .8 of CVI. Four factors explained 78.71% of the total variance among items for sobriety intention and direct measure, and six factors explained 67.99% of the total variance among indirect measure items and those factors coincided with the variables of TPB in factor analysis. Cronbach's ${\alpha}$ of this questionnaire was .873 and the result of test-retest reliabilty test was relatively reliable. A total of 41 items with 7-point scale were constructed in the final version. Conclusion: This questionnaire was valid and reliable to measure sobriety behavior based on TPB in male workers. It can be useful to evaluate the result of a sobriety program for male workers.

Evaporation Heat Transfer Characteristics of Liquid Nitrogen in Horizontal Plain Tubes with Wire Coil Inserts (평활관 및 열전달촉진관에서 액체질소의 관내 증발열전달 특성에 대한 연구)

  • Hwang, Jee-Sang;Chung, Jin-Taek;Yun, Rin;Kim, Yong-Chan;Moon, Young-June;Kim, Dong-Hyuk
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1359-1364
    • /
    • 2004
  • An experiment was performed to study the evaporation heat transfer and the pressure drop characteristics of liquid nitrogen in a horizontal stainless steel tube with wire coil inserts. The inner diameter of test tube is 4.3mm and the length is 1.5m. Four wire coils having different pitch and thickness were inserted into the plain test tube. The wire coil length is 1.5m and the diameter is 3.65mm with thickness of 0.5mm and 0.9mm. Experiments were conducted at saturation temperature of $-191^{\circ}C$ mass flux from 200 to 370 $kg/m^{2}s$ and heat flux of 62 $kW/m^{2}$. Direct heating method was used to apply heat to the test section. Boiling heat transfer coefficients of both the plain and the enhanced tubes were calculated. Pressure drops between inlet and outlet side of test section were also measured, and they are used to estimate EPR(Enhancement Performance Ratio).

  • PDF

A Synthetic Test Circuit for HVDC Thyristor Valve Test with Simplified Turn-Off Circuit of Auxiliary Thyristor (보조 사이리스터의 턴-오프 회로를 간소화한 HVDC 사이리스터 밸브 시험용 합성시험회로)

  • Jung, Jae-Hun;Goo, Beob-Jin;Jeo, Han-Je;Nho, Eui-Cheol;Han, Byung-Moon;Chung, Yong-Ho;Baek, Seung-Taek
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.5
    • /
    • pp.475-480
    • /
    • 2014
  • This study proposes a new synthetic test circuit (STC) for HVDC thyristor valve tests. The conventional STC with a 2-phase chopper requires a 3-phase transformer, a 3-phase diode rectifier, and an IGBT to facilitate the off state of an auxiliary thyristor. In the proposed STC, these three components are replaced with one diode and one resistor, which result in the simplified implementation of the hardware of the STC. Simulation and experimental results demonstrate the validity of the proposed scheme.