• Title/Summary/Keyword: direct test

Search Result 3,323, Processing Time 0.034 seconds

Microtensile bond strength of repaired indirect resin composite

  • Visuttiwattanakorn, Porntida;Suputtamongkol, Kallaya;Angkoonsit, Duangjai;Kaewthong, Sunattha;Charoonanan, Piyanan
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.1
    • /
    • pp.38-44
    • /
    • 2017
  • PURPOSE. The objective of this study was to investigate the effect of surface treatments on microtensile bond strengths (MTBSs) of two types of indirect resin composites bonded to a conventional direct resin composite. MATERIALS AND METHODS. Indirect resin composite blocks of Ceramage and SR Nexco were prepared in a plastic mold having a dimension of $10{\times}10{\times}4\;mm$. These composite blocks were divided into three groups according to their surface treatments: Group1: Sandblast (SB); Group2: Sandblast and ultrasonically clean (SB+UL); Group3: Sandblast plus silane (SB+SI). After bonding with direct resin composite, indirect-direct resin composite blocks were kept in distilled water for 24 hours at $37^{\circ}C$ and cut into microbars with the dimension of $1{\times}1{\times}8\;mm$. Microbar specimens (n = 40 per group) were loaded using a universal testing machine. Failure modes and compositions were evaluated by SEM. The statistical analyses of MTBS were performed by two-way ANOVA and Dunnett's test at ${\alpha}=.05$. RESULTS. Surface treatments and brands had effects on the MTBS without an interaction between these two factors. For SR Nexco, the MTBSs of SB and SB+SI group were significantly higher than that of SB+UL. For Ceramage, the MTBSs of SB and SB+SI were significantly higher than that of SB+UL. The mean MTBS of the Ceramage specimens was significantly higher than that of SR Nexco for all surface treatments. CONCLUSION. Sandblasting with or without silane application could improve the bond strengths of repaired indirect resin composites to a conventional direct resin composite.

Comparison of LDL-Cholesterol direct measurement with the estimate using various formula

  • Kwon, Se Young;Na, Young-Ak
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.44 no.3
    • /
    • pp.103-111
    • /
    • 2012
  • Low-Density Lipoprotein cholesterol (LDLC) is the most important marker for the treatment of hyperlipidemia in NCEP-ATP III(National Cholesterol Education Program-Adult Treatment Panel III) guideline. Therefore, LDL cholesterol is pathologically meaningful, accurate measurement should be a top priority. Currently, LDLC is directly measured in most cases, but, the estimate is still used in mass health examination or screening test. This study is about the comparison of LDL-Cholesterol direct measurement with the estimate using various formula (Friedewald: [LDL-F=TC-HDL-TG/5], Nakajima: [LDL-N=TC-HDL-TG/4], Hattori: [LDL-H =0.94TC-0.94HDL-0.19TG], Puavilai: [LDL-P=TC-HDL-TG/6], Carvalho: [LDL-C=3(TC-HDL)/4]) for calculating more accurate value. We analyzed total cholesterol (TC), try-glyceride (TG), high-density lipoprotein cholesterol (HDLC), and LDLC levels of 210 subjects between June and November in 2011. Until now, the Friedewald formula is the most commonly used estimate for the LDLC. When Friedewald formula was applied, the correlation coefficient (r) was 0.940, showing high correlation. But, the result of the direct method was significantly different, compared with those of the Friedewald formula in triglyceride levels ${\geq}400mg/dL$(p<0.05). There was the highest correlation when we used LDL-P formula(r=0.947) in triglyceride levels <400 mg/dl. Also there was the lowest mean difference regardless of triglyceride level. Therefore, the study showed that TG/6 is more precise means of calculation than TG/5. On the other hand, the calculation of LDL-Cholesterol was underestimated, compared with direct measurement. It is necessary to have more data and modified Friedewald formula should be used for the accurate calculation.

  • PDF

Numerical Study on the Process of Supersonic Flow Formation in a Direct-Connect Supersonic Combustor (Direct-Connect 초음속 연소기 내 초음속 유동 형성과정에 대한 수치해석)

  • Jeong, Seong-Min;Han, Hyunh-Seok;Sung, Bu-Kyeng;Lee, Eun-Sung;Choi, Jeong-Yoel
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.48 no.11
    • /
    • pp.889-902
    • /
    • 2020
  • In this study, a numerical analysis was performed to confirm the formation of supersonic flow and the stabilization time satisfying the design condition in a Direct-connect supersonic combustor. The process was examined in which the high-pressure gas of vitiation air heater propagates downstream to the supersonic combustor and forms a supersonic flow field. It was confirmed through the analysis of pressure and temperature that the supersonic flow field satisfies the design points of Mach number 2.0 and 1,000 K, and requires a minimum of 4.0 ms for stabilization. These results indicate that the time required for the supersonic flow field stabilization should be taken into account when testing for the supersonic combustion experiment.

Particulate Emissions from a Direct Injection Spark-ignition Engine Fuelled with Gasoline and LPG (가솔린 및 LPG 연료를 사용하는 직접분사식 불꽃점화엔진에서 배출되는 극미세입자 배출 특성에 관한 연구)

  • Lee, Seok-Hwan;Oh, Seung-Mook;Kang, Kern-Yong;Cho, Jun-Ho;Cha, Kyoung-Ok
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.19 no.3
    • /
    • pp.65-72
    • /
    • 2011
  • In this study, the numbers, sizes of particles from a single cylinder direct injection spark-ignition (DISI) engine fuelled with gasoline and LPG are examined over a wide range of engine operating conditions. Tests are conducted with various engine loads (2~10bar of IMEP) and fuel injection pressures (60, 90, and 120 bar) at the engine speed of 1,500 rpm. Particles are sampled directly from the exhaust pipe using rotating disk thermodiluter. The size distributions are measured using a scanning mobility particle sizer (SMPS) and the particle number concentrations are measured using a condensation particle counter (CPC). The results show that maximum brake torque (MBT) timing for LPG fuel is less sensitive to engine load and its combustion stability is also better than that for gasoline fuel. The total particle number concentration for LPG was lower by a factor of 100 compared to the results of gasoline emission due to the good vaporization characteristic of LPG. Test result presents that LPG for direct injection spark ignition engine help the particle emission level to reduce.

Changes in Sensory Function After Transcranial Direct Current Stimulation on Primary Motor Cortex Area

  • Min, Dong-Ki
    • Physical Therapy Korea
    • /
    • v.21 no.4
    • /
    • pp.1-8
    • /
    • 2014
  • Transcranial direct current stimulation (tDCS) is a neuromodulatory technique that delivers low-intensity direct current to cortical areas, thereby facilitating or inhibiting spontaneous neuronal activity. This study was designed to investigate changes in various sensory functions after tDCS. We conducted a single-center, single-blinded, randomized trial to determine the effect of a single session of tDCS with the current perception threshold (CPT) in 50 healthy volunteers. Nerve conduction studies were performed in relation to the median sensory and motor nerves on the dominant hand to discriminate peripheral nerve lesions. The subjects received anodal tDCS with 1 mA for 15 minutes under two different conditions, with 25 subjects in each groups: the conditions were as follows tDCS on the primary motor cortex (M1) and sham tDCS on M1. We recorded the parameters of the CPT a with Neurometer$^{(R)}$ at frequencies of 2000, 250, and 5 Hz in the dominant index finger to assess the tactile sense, fast pain and slow pain, respectively. In the test to measure CPT values of the M1 in the tDCS group, the values of the distal part of the distal interphalangeal joint of the second finger statistically increased in all of 2000 Hz (p=.000), 250 Hz (p=.002), and 5 Hz (p=.008). However, the values of the sham tDCS group decreased in all of 2000 Hz (p=.285), 250 Hz (p=.552), and 5 Hz (p=.062), and were not statistically significant. These results show that M1 anodal tDCS can modulate sensory perception and pain thresholds in healthy adult volunteers. The study suggests that tDCS may be a useful strategy for treating central neurogenic pain in rehabilitation medicine.

Evaluation of diagnostic ability of CCD digital radiography in the detection of incipient dental caries (CCD 디지털 방사선사진촬영법의 초기 치아우식증의 진단능 평가에 대한 연구)

  • Lee Wan;Lee Byung-Do
    • Imaging Science in Dentistry
    • /
    • v.33 no.1
    • /
    • pp.27-33
    • /
    • 2003
  • Purpose : The purpose of this experiment was to evaluate the diagnostic ability of a CCD-based digital system (CDX-2000HQ) in the detection of incipient dental caries. Materials and Methods : 93 extracted human teeth with sound proximal surfaces and interproximal artificial cavities were radiographed using 4 imaging methods. Automatically processed No.2 Insight film (Eastman Kodak Co., U.S.A.) was used for conventional radiography, scanned images of conventional radiograms for indirect digital radiography were used. For the direct digital radiography, the CDX-2000HQ CCD system (Biomedisys Co. Korea) was used. The subtraction images were made from two direct digital images by Sunny program in the CDX-2000HQ system. Two radiologists and three endodontists examined the presence of lesions using a five-point confidence scale and compared the diagnostic ability by ROC (Receiver Operating Characteristic) analysis and one way ANOV A test. Results: The mean ROC areas of conventional radiography, indirect digital radiography, direct digital radiography, and digital subtraction radiography were 0.9093, 0.9102, 0.9184, and 0.9056, respectively. The diagnostic ability of direct digital radiography was better than the other imaging modalities, but there were no statistical differences among these imaging modalities (p > 0.05). Coclusion : These results indicate that new CCD-based digital systems (CDX-2000HQ) have the potential to serve as an alternative to conventional radiography in the detection of incipient dental caries.

  • PDF

A Study on Combustion and Exhaust Emission in Direct Injection Diesel Engine (직접분사식 디젤기관의 연소 및 배기에 관한 연구)

  • Kim, Du-Beom;Kim, Gi-Bok;Kim, Chi-Won;Han, Sung-Hyun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.20 no.2
    • /
    • pp.105-113
    • /
    • 2017
  • Recently the direct injection diesel engine is the most efficient one available for road vehicles, so this fundamental advantage suggests the compression injection diesel engine are a wise choice for future development efforts. The compression ignition diesel engine, with its bigger compression ratios if compared to the SI engine, offers a higher thermodynamic efficiency, also additionally the diesel engine with its less pumping losses due to the throttled intake charge as in a SI engine has higher fuel economy. But the largest obstacle to the success of this engine is meeting emission standards for Nitric oxides and particulate matter while maintain fuel consumption advantage over currently available engines. Thus its use should be largely promoted, however, diesel engine emits more Nitric oxides and particulate matter than other competing one. There has been a trade-off between PM and NOx, so efforts to reduce NOx have increased PM and vice versa, but trap change this situation and better possibility emerge for treating NOx emission with engine related means, such as injection timing, equivalence ratio, charge composition, and engine speed. The common rail direct injection system is able to adjust the fuel injection timing in a compression ignition engine, so this electronically controlled injection system can reduce the formation of NOx gas without increase in soot. In this study it is designed and used the engine test bed which is installed with turbocharge and intercooler. In addition to equipped using CRDI by controlling injection timing with mapping modulator, it has been tested and analyzed the engine performance, combustion characteristics, and exhaust emission as operating parameters.

Effective Teaching-Learning Activities in Flipped, Direct, Cooperative, and Distance Learning Model (거꾸로 수업, 직접교수법, 협동학습, 실시간 화상수업을 조합한 수업에서의 효과적인 교수학습활동)

  • Kil, Yangsook
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.1
    • /
    • pp.121-129
    • /
    • 2022
  • This study explored effective teaching-learning activities under the hybrid teaching model combining flipped learning, direct instruction, cooperative learning and distance learning. Subjects were 99 college students enrolled in 2 teacher preparation courses. Students evaluated effectiveness of 22 teaching-learning activities according to Likert scale at the end of the semester. As a result, all 22 teaching learning activities were considered effective more or less. They facilitated motivation, comprehension, participation, thinking, and led to mastery of the task. ② Activities scored low were 'questioning and answering at the beginning of online class', 'open book test'. ③ Hybrid teaching model was favored over traditional instruction. Open ended responses were consistent with the ones in the questionnaire. This research supports the notion that key teaching models to be combined for successful flipped learning in college setting are direct instruction and cooperative learning. Furthermore, effective and ineffective teaching strategies for flipped learning were found.

Comparison of Nursing Activity Time According to the Change in Grade of Nursing Management Fee in One University Hospital (일개 대학병원의 간호관리료 등급변화에 따른 간호사의 간호활동시간 비교)

  • Park, Jeong Ok;Kim, Heai Yong;Roh, Gyeong Shik;Roh, Young Duck;Park, Myeong Bun;So, Ji Eun;Park, Mi Mi;Bang, Kyung Sook
    • Journal of Korean Clinical Nursing Research
    • /
    • v.16 no.1
    • /
    • pp.95-105
    • /
    • 2010
  • Purpose: The purpose of this study was to examine the difference between direct and indirect nursing activity times according to the grade of nursing management fee. Methods: The subjects of this study were 324 working nurses at the time of 3rd grade and 319 working nurses at the 2nd grade of nursing management fee in one university hospital. Nursing activity time was measured in April and May, and in September and October of 2008 for comparison. The data were analyzed by SPSS win using frequency and t-test. Results: Direct nursing care activity time per one patient was significantly higher at 2nd grade than 3rd grade in day shift (t=-2.55, p=.012). Direct nursing care workload per one nurse was significantly lower at 2nd grade than 3rd grade in evening shift (t=2.21, p=.030), whereas indirect nursing care workload was lower at 2nd level in night shift (t=2.43 p=.016). Conclusion: The findings from this study showed that higher nurse-to-patient ratio can provide greater amount of direct nursing care activity for the patient. Also, it decreased workload of nurses. The higher nurse-to-patient ratio will be beneficial for promoting quality of nursing care as well as decreasing nurse's heavy workload.

Gender Differences of Direct and Relational Aggression in Children and Adolescents (국내 초등학생 및 중학생의 성별에 따른 직접적 공격성과 관계적 공격성의 차이)

  • Jeong, Da-un;Kim, Ji-Woong;Hong, Hyun-ju;Kim, Seung-Jun;Lee, Na-Hyun;Yang, Ji-sun;Ahn, Song-ii;Im, Woo-Young;Jhung, Kyungun
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.23 no.2
    • /
    • pp.86-92
    • /
    • 2015
  • Objectives : The aim of this study was to investigate the gender differences of direct aggression and relational aggression in Korean elementary and middle school students. Methods : Parents of 946 elementary school students(age $9.54{\pm}1.72$ years, 485 boys, 461 girls) completed the Child Behavior Checklist(CBCL). Six-hundred-and-three middle school students(age $13.98{\pm}0.93$ years, 301 boys, 302 girls) completed the Youth Self-Report(YSR). Independent t-test, chi-square test, and Fisher's exact test were used. Results : Boys had significantly higher direct aggression scores than girls in elementary school students(p<0.001). There was no significance gender difference of relational aggression in elementary school students(p=0.235). In middle school students, boys had significantly higher direct aggression than girls(p=0.017), and girls had significantly higher relational aggression compared to the boys(p<0.001). Conclusions : Our results suggest the presence of gender differences in manifestation of aggression subtypes in Korean elementary and middle school students. These gender differences should be taken into account in prevention and intervention approaches of aggression in children and adolescents.