• Title/Summary/Keyword: direct test

Search Result 3,323, Processing Time 0.213 seconds

A study on coefficient of permeability due to disturbed level of clay by direct permeability test with consolidation test (압밀시험중 직접투수시험에 의한 불교란 점토의 교란정도와 투수계수에 관한 연구)

  • Kim, Jae-Young;Kim, Dong-Hyun;So, Choong-Seop;Takada, Naotoshi
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.248-252
    • /
    • 2005
  • Compressibility and deformability of clays change greatly when the clays are subjected to disturbance. These tendencies have been studied. However, the effect of the disturbance on the permeability that consists of consolidation properties has not yet been studied. In this study, relationship between permeability and volume ratio under the different degree of disturbance are experimently obtained. The results indicate that the relations are less influenced if the disturbance is less depending on the kind of soils.

  • PDF

Bayes tests of independence for contingency tables from small areas

  • Jo, Aejung;Kim, Dal Ho
    • Journal of the Korean Data and Information Science Society
    • /
    • v.28 no.1
    • /
    • pp.207-215
    • /
    • 2017
  • In this paper we study pooling effects in Bayesian testing procedures of independence for contingency tables from small areas. In small area estimation setup, we typically use a hierarchical Bayesian model for borrowing strength across small areas. This techniques of borrowing strength in small area estimation is used to construct a Bayes test of independence for contingency tables from small areas. In specific, we consider the methods of direct or indirect pooling in multinomial models through Dirichlet priors. We use the Bayes factor (or equivalently the ratio of the marginal likelihoods) to construct the Bayes test, and the marginal density is obtained by integrating the joint density function over all parameters. The Bayes test is computed by performing a Monte Carlo integration based on the method proposed by Nandram and Kim (2002).

A Study on the Measurement of the Crack Length for the Real Scale Pipe Specimen (실배관 시험편의 균열 길이 측정에 관한 연구)

  • Park, Jae-Sil;Seok, Chang-Sung
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.397-402
    • /
    • 2003
  • Fracture resistance curves for concerned materials are required in order to perform elastic-plastic fracture mechanical analyses. Fracture resistance curve is built with J-integral values and crack extension values. The objective of this paper is to apply the load ratio method to the measurement of the crack length for the real scale pipe specimen. For these, the fracture test using the real scale pipe specimen and finite element analyses were performed. A 4-point bending jig was manufactured for the pipe test and the direct current potential drop method and the load ratio method was used to measure the crack extension and the length for the real scale pipe test. Finite element analyses about the compliance of the pipe specimen were executed for applying the load ratio method according to the crack length.

  • PDF

A Study on the Effect of Heat-treatment on the Fatigue Strength of SNC815 Spur Gears (SNC815 기어의 피로강도에 미치는 열처리 효과에 관한 연구)

  • Lyu, Sung-Ki;Nam, Tae-Hyun;Lee, Jin-Yi
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.13 no.1
    • /
    • pp.21-26
    • /
    • 2000
  • This study deals with effects of heat-treatment on the fatigue strength of SNC815 spur gears. The test gears are heat-treated by two different treatments. After carburization, one group of the test gears is quenched directly, while the other group is fumace cooled, reheated then quenched. The fatigue test at a constant stress amplitude is performed by using an electrohydraulic servo-controlled pulsating tester. The S-N curves are obtained and illustrated. By comparing the estimated strength with the experimental results, the validity of the previous experimental formula, presented by the author for estimating the fatigue strength of carburized gears, was discussed on these tested gears.

  • PDF

A New-Generation Sensorless Vector Control Scheme for Induction Motor Drive

  • Shinnaka, Shinji
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.287-292
    • /
    • 1998
  • This paper presents some results of performance evaluation test via actual machines of a new hybrid vector control utilizing a new indirect orientation scheme and stable filter embedded direct orientation scheme for induction motors without speed or position sensor. It is shown through the test by 0.3(kW) and 3.7(kW) motors that the proposed sensorless vector control has the following high potentialities: 1) speed range is 0 to 600(rad/s) or more, 2) zero-speed command is accepted and settles the machines at a stable standstill with no vibration 3) it can make machines to track variable command of acceleration and deceleration $\pm$6,000(rad/s2), 4) it can make machines to drive directly load of at least 26 times larger inertia than that of the machine, 5) it can make machines to produce much larger torque than the rating in torque control mode even at standstill. The performance confirmed by the test is far away for previous schemes or sensorless drive apparatuses.

  • PDF

Antimutagenic Effects of Linoleic Acid

  • Lim, Sun-Young;Rhee, Sook-Hee;Park, Kun-Young
    • Preventive Nutrition and Food Science
    • /
    • v.2 no.1
    • /
    • pp.29-34
    • /
    • 1997
  • In order to determine the effectiveness of linoleic acid(LA) to inhibit carcinogens/mutagens-induced mu-tagenesis, Ames test using Salmonella typhimurium TA100 and the SOS chromotest using E. Coli PQ37, were carried out. The inhibitory effect of LA(1%) on the Ames mutagenicity test were 98%, 78%and 69% mediated by aflatoxin B₁(AFB₁), N-methyl-N'-nitro-N-nitrosoguanidine(MNNG) and 4-nitroquinoline-1-oxide(4-NQO), respectively. LA exhibited a strong antimutagenic activity aganist indirect mutagen, AFB₁whereas exhibited the same concentration of LA showed weaker inhibitory effects on direct mutagens of MNNG and 4-NQO than that AFB₁. LA also reduced the SOS responses induced by MNNG and 4-NQO significantly. This result showed a possibility that LA can be a protective agent in early step of cancinogenesis.

  • PDF

Feline panleukopenia virus infection in imported cats

  • Kang, Sang-Chul;Kang, Kyung-Il;Jean, Young-Hwa;Kim, Jae-Hoon
    • Korean Journal of Veterinary Research
    • /
    • v.47 no.4
    • /
    • pp.437-441
    • /
    • 2007
  • The cases of feline panleukopenia virus (FPLV) infection were diagnosed in three imported cats. All cats died within one week after mild emaciation, depression and anorexia. One cat showed yellowish watery diarrhea. At necropsy, all cats had segmental hemorrhage on the serosa and mucosa of the small intestine. Histopathologically, severe diffuse necro-hemorrhagic enteritis was observed in small intestine especially in jejunum and ileum. The crypts of Lieberkuhn were dilated and contained necrotic epithelia. Severely damaged epithelia of crypts were transformed into bizarre shapes. Multifocal lympholysis and lymphoid depletion were found in Peyer's patches and other lymphoid tissues. Direct fluorescent antibody (FA) test revealed the characteristic FPLV antigen in the cytoplasms of crypt epithelial cells. Based on the clinical signs, characteristic pathologic findings and FA test, these cases were diagnosed as FPLV infection. In our best knowledge, this study is the first case report for FPLV infection in imported cats in Korea.

A Study on the Optimization of Articulated Steel Forging Piston and 3D Analysis of Fluid Characteristics for Light Duty DI Diesel Engine (직접분사식 소형 디젤엔진의 3D 유동특성 및 분절형 스틸 단조 피스톤의 최적화에 관한 연구)

  • 김현철;박종호
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.12 no.5
    • /
    • pp.25-31
    • /
    • 2004
  • In order to prepare for the large power diesel vehicle, the current trend of advanced nations is to shift from the aluminum alloy piston to the steel piston. In this research, a steel forging piston which replaces the aluminum alloy piston is developed to improve the power performance of the diesel engine. The three dimensional flow and combustion analysis of the target engine is conducted. Using the result of the analysis, the piston is optimized, and a prototype of the articulated steel forging piston is built. The reliability of the piston has been evaluated through durability test using a Hydropuls Test Machine for 300,000 km.

Reignition system for synthetic short-circuit test (합성단락시험용 재점호장치)

  • Park, Seung-Jae;Kim, Maeng-Hyun;Kang, Young-Sig;Shin, Young-June;Koh, Heui-Sek
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1856-1858
    • /
    • 2000
  • This paper describes the principles of reignition system which has newly been developed and used as KERI's high power testing facilities. Synthetic short-circuit testing method is generally adopted to perform the short-circuit test of the ultra high-voltage circuit breakers, which consists of two separated sources such as the current source from short-circuit generator and the voltage source from charged energy in capacitor. And, in case of synthetic short-circuit test, it will be necessary to use the reignition system in order to extending the arcing time of the circuit breaker and provide the arc energy equivalent to the direct testing method.

  • PDF

Development of Hybrid Fiber Reinforced Polymer Reinforcing Bars and Evaluation of the Bond Properties (하이브리드 FRP 보강근의 형상개발과 부착성능 평가)

  • Park, Ji-Sun;Park, Young-Hwan;You, Young-Jun;Kim, Keung-Hwan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.629-632
    • /
    • 2006
  • The various rib geometry of hybrid fiber reinforced polymer (FRP) reinforcing bars were analyzed by finite element method. From the analysis result, two types of hybrid FRP reinforcing bars such as spiral and cross type with the same dimension of rib geometry were fabricated in this study. To evaluate the bond properties of them, direct pull-out test was performed. All testing procedures including specimens preparation, set-up of test equipments and measuring devices were made in accordance with the recommendations of CSA Standard S806-02. From the test results, it was found that cross type hybrid FRP reinforcing bars showed the highest bond strength than that of the others due to the higher relative rib area.

  • PDF