• Title/Summary/Keyword: direct test

Search Result 3,324, Processing Time 0.028 seconds

Contribution of Tourism and Foreign Direct Investment to Gross Domestic Product: Econometric Analysis in the Case of Sri Lanka

  • MOHAMED MUSTAFA, Abdul Majeed
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.6 no.4
    • /
    • pp.109-114
    • /
    • 2019
  • The purpose of the study to evaluate the contribution of foreign direct investment (FDI) and tourism receipts (TR) to Sri Lanka's gross domestic product (GDP). This study employs time series annual data for the period from 1978 to 2016 and EViews 10 econometrics software was used for the time series data analysis. Unit root test was done on the variables and the method chosen was the Augmented Dicky - Fuller test. Co-integration analysis was used for the long run relationship and the Granger causality test was performed to investigate the causal relationship. Recently a more conducive environment has been established after the three decade long ethnic war came to an end. In this context, the Sri Lankan government has taken positive measures to attract foreign direct investment and boost tourism in the country. This study intends to evaluate the contribution of Sri Lanka, as these two factors are considered to be very effective at increasing the GDP of a country. The empirical study shows that there is a positive and statistically significant relationship between the variable's TR and FDI to the GDP in the long run. Results of Granger causality test implied that the two-way causality promoted the economic growth of Sri Lanka.

A Study on the Performance of a Sprinkler System with Direct-Coupled Waterworks by Full-Scale Fire Test (실화재실험을 통한 상수도 직결형 스프링클러시스템의 성능에 관한 연구)

  • Jung, Jong-Jin;Nam, Dong-Gun;Lim, Woo-Sub
    • Fire Science and Engineering
    • /
    • v.25 no.6
    • /
    • pp.39-43
    • /
    • 2011
  • In this research, full-scale fire test was performed on a real house for the evaluation of the performance of waterworks direct-coupled sprinkler system. The fire was set to occur as spontaneous combustion as the cooking oil overheats. The size of house is $56m^2$ and it consists of a living room, a kitchen, and a room. In order to verify the performance of waterworks direct-coupled sprinkler system, it was installed in the kitchen. The result of the test showed that the fire started from the kitchen enlarged up to its ceiling but it was soon exhausted as the sprinkler started to work. The pressure of the waterworks was 0.28 MPa when the sprinkler operated, by which it verified that fire could go out even by waterworks pressure of the general residence.

Direct Shear Test of Retrofit Anchors Using Deformed Reinforcement and Adhesive

  • Choi, Dong-Uk;Kim, Yong-Gon
    • KCI Concrete Journal
    • /
    • v.12 no.1
    • /
    • pp.91-99
    • /
    • 2000
  • A new type of retrof=t anchor bolt that uses deformed reinforcing bars and a commercial adhesive was developed and then an experimental study was carried out to determine the behavior of the anchors in direct shear. The steel-to-concl몫ete interface was tested. Plain concrete slabs with about 20-MPa compressive strength were used for 23 direct shear tests performed Test variables were anchor diameters (D16, D22. and D29) and edge effect. Three different shear tests were completed: simple shear, edge shear where anchors were pulled against the concrete core, and edge shear where anchors were pushed against the concrete cover In the simple and the edge shear tests where the anchors were pulled against the core, the theoretical dowel strength determined by (equation omitted) was achieved but with relatively large displacements. The shear resistances increased with the increasing displacements. In the edge shear test where the anchors were pushrd against the cover, the peak shear strengths signif=cantly lower than the theoretical dowel strength were determined due to cracks developed in concrete when the edge distance was 80 mm. The peak strengths were about 50% of the dowel strength for Dl6 bar. and about 25% or less of the dowel strength for D22 and D29 bars. Test results revealed that the edge shear where the anchor was pushed against the cover controled.

  • PDF

Implementation and Effectiveness of Parent Education Program Emphasizing Direct Interaction with Young Children in a Digital Environment (디지털 환경에서 영유아와의 직접적인 상호작용을 강조하는 부모교육 프로그램의 실행과 효과)

  • Kwen, Hea Lim;Lee, Wan Jeong
    • Korean Journal of Childcare and Education
    • /
    • v.18 no.1
    • /
    • pp.1-22
    • /
    • 2022
  • Objective: This study attempted to verify the effectiveness of parent education programs which emphasize parents' direct interaction with young children even when using digital devices. For this purpose, parents' play beliefs and their interaction with their children were evaluated by taking a pre-test and post-test. Methods: The subjects of this study were parents of young children attending child care centers. The collected data were analyzed by one-way covariate analysis (ANCOVA) to find out if there was a significant difference in post-test scores after controlling the pre-test as a covariate to minimize possible errors between groups before the experiment. Results: Parents, who had participated in the parent education program which emphasized parents' direct interaction with young children when using digital devices, showed higher increases of play support beliefs and parent-child interaction than the comparative group. Conclusion/Implications: This study confirmed that in order to develop digital fluency from early childhood, parents should avoid indiscriminate use of digital devices at home, maintain direct interaction with their children even when giving them digital devices to play with, and support healthy growth by way of continuing sensitive interaction with their children.

A Study on the Direct Discharge Test for Verifying Design Concentration and Soaking Time for CO2 Fire Extinguishing System of Total Flooding (전역방출방식 CO2 소화설비의 설계농도 및 유지시간 검증을 위한 직접방사실험에 관한 연구)

  • Lee, Se-Myeoung;Moon, Sung-Woong;Ryu, Sang-Hoon
    • Fire Science and Engineering
    • /
    • v.26 no.6
    • /
    • pp.15-23
    • /
    • 2012
  • Indirect Test Method is often used instead of direct test method in test method for extinguishing performance of $CO_2$ extinguishing facility because of high cost, environment problems and difficulties of procedure. But in the danger facilities for a unit of nation, such as a petrochemical plant, a nuclear power plant, or etc. is better to verify the performance of the extinguishment through direct discharge test. In $CO_2$ extinguishing system for total flooding system installed in dangerous facilities in Korea, each protected area in surface fire and deep-seated fire had selected and verified of extinguishing performance of $CO_2$ extinguishing facilities. To get recognized as extinguishing performance, discharged $CO_2$ concentration to protected area should be equivalence with design concentration standards (NFSC and NFPA). The Design Concentration means that $CO_2$ extinguishing agent is considerate of concentration for percentage of allowance (20 %) from extinguishing concentration which available to control of flame. As test result, surface fire and deep seated fire in protected area is obtained $CO_2$ design concentration and maintained design concentration more than 20 minutes as deep-seated fire. Through this study, we introduced direct discharging test method and decision method. And furthermore, especially in the dangerous facilities as a unit of Nation, we suggested necessity about reliability of extinguishing facilities to use direct test method.

A Study on the Impact of Real Exchange Rate Volatility of RMB on China's Foreign Direct Investment to Japan

  • He, Yugang
    • East Asian Journal of Business Economics (EAJBE)
    • /
    • v.6 no.3
    • /
    • pp.24-36
    • /
    • 2018
  • Purpose - From establishing China-Japan diplomatic relations in 1972, the relations between two states has improved a lot, from which makes the government and the people reap much benefit. Owing to this reason, this paper aims at exploiting the impact of exchange rate volatility of RMB on China's foreign direct investment to Japan. Research design and methodology - The quarterly time series data from 2003 to 2016 will be employed to conduct an empirical analysis under the vector error correction model. Meanwhile, a menu of estimated methods such the Johansen co-integration test and the Granger Causality test will be also used to explore the impact of exchange rate volatility of RMB on China's foreign direct investment to Japan. Results - The empirical analysis results exhibit that the real exchange rate has a positive effect on China's foreign direct investment to Japan in the long run. Conversely, the real exchange rate volatility of RMB, the trade openness and the real GDP have a negative effect on China's foreign direct investment to Japan in the long run. However, in the short run, the China's foreign direct investment to Japan, the real exchange rate, the trade openness and the real GDP in period have a negative effect on China's foreign direct investment to Japan in period. Oppositely, the real exchange rate volatility of RMB in period has a positive effect on China's foreign direct investment to Japan in period. Conclusions - From the empirical evidences in this paper provided, it can be concluded that an increase in the exchange rate volatility of RMB can result in a decrease in the China's foreign direct investment to Japan in the long run. However, an increase in the exchange rate volatility of RMB can lead to an increase in the China's foreign direct investment to Japan in the short run. Therefore, the China's government should have a best control of the real exchange rate volatility of RMB so as to improve China's foreign direct investment to Japan.

Characteristics of Soils Reinforced by FPF(Fibrillated Polypropylene Fiber) (FPF(Fibrillated Polypropylene Fiber)보강 성토재료의 강도 특성에 관한 연구)

  • 김낙경;박종식
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2001.03a
    • /
    • pp.433-440
    • /
    • 2001
  • This study was to analyze characteristics of soils reinforced by FPF(Fibrillated Polypropylene Fiber). Laboratory test, model test and field tests were performed on soils reinforced by fibers, to evaluate the shear strength characteristics. For the silty sand, clayey sand and silty clay, the influence of fiber shape, fiber length and fiber content were evaluated from compaction test, direct shear test, uniaxial test, california bearing ratio(CBR) test. Fibrillated type fiber, 5cm long with a content of 0.5% shows 5∼30% increase of friction angle and 7∼55 percent increase of CBR value.

  • PDF

Development of Direct-Wet-Rice-Seedling Machines in Korea

  • Rhee, Joong-Young;Lee, Chong-Ho-
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1993.10a
    • /
    • pp.256-266
    • /
    • 1993
  • History , achievement and future of direct-wet-rice-seeding technique in Korea and problems encountered in on-farming research were introduced. Some farmers are very eager to lower production cost and save labor. Their effort results in several direct-wet-seeding methods and seeding machines. The design problems and improvement points related to the direct -wet-rice-seeding machines were drawn out of field test.

  • PDF

Shear Behavior of Sands Depending on Shear Box Type in Direct Shear Test (직접전단실험시 전단상자의 종류에 따른 모래시료의 전단거동)

  • Hong, Young-Ho;Byun, Yong-Hoon;Chae, Jong-Gil;Lee, Jong-Sub
    • Journal of the Korean Geotechnical Society
    • /
    • v.31 no.3
    • /
    • pp.51-62
    • /
    • 2015
  • Shear behavior obtained by direct shear tests is dependent on shear box and boundary condition. The objective of this study is to analyze problems of conventional direct shear test (type-A) and provide the reliable results by developing type-C direct shear apparatus. Experimental tests are carried out for Ulleung sand by using type-A and -C direct shear devices. The soil specimens, which are prepared at the relative density of 60%, and are applied to vertical confining stresses of 50, 100, 200, 300, and 400 kPa, are sheared at a constant shear strain rate of 0.5 mm/min. By comparing the results obtained by type-A and -C direct shear apparatus under constant normal load (CNL) condition, the performance of new one is verified. In addition, two constrained conditions including constant normal load (CNL) and constant pressure (CP) are applied to type-C one. Experimental results show that type-A direct shear apparatus has some problems such as rotating of loading plate and upper shear box, and the frictional forces between soil and inner wall of upper shear box. Thus, the shear strengths obtained by type-A device are overestimated or underestimated depending on shear box and boundary condition. On the other hand, type-C device produces clear and consistent test results regardless of constrained conditions. This study represents that type-C direct shear apparatus not only can solve the problems of type-A direct shear apparatus but provide the reliable results.

Investigation of Domestic Application for Soil Impact Hammer(SIH) (동적 지반물성측정장치(SIH, Soil Impact Hammer)의 국내 적용성 평가)

  • 박재영;석정우;황대진;양구승
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.10a
    • /
    • pp.411-418
    • /
    • 2002
  • In domestic road construction sites, the compaction control based on strength are widely performed through the direct method with high accuracy, such as Plate Loading Test or Field CBR test. It is impossible to manage all construction sites using the direct method because the direct method requires heavy reaction loads and long measurement time. Therefore, it is necessary to apply the indirect method that could control the relative density of construction sites on the whole. Indirect methods, such as Cone Penetration Test and Fall Cone Test, require extra time for data analyzing and fixed area for test device. In this paper, the field applicability of Soil Impact Hammer (SIH) was investigated comparing with the results of field measurement tests and laboratory compaction tests. SIH developed by Japan Construction Administration and Asanuma Ltd., is a kind of indirect methods for compaction checking. According to the results of SIH performed in domestic road construction site, the subgrade reaction modulus obtained from SIH are similar to that from Plate loading tests in the range of 10 to 40. In comparison with laboratory compaction test, similar compaction line are shown in the dry side of optimum moisture contents.

  • PDF