• Title/Summary/Keyword: direct heat method

Search Result 263, Processing Time 0.025 seconds

Comparison of microwave and steam-type drying processes for dehydrated sludge in a wastewater treatment plant (탈수슬러지의 마이크로웨이브와 증기 건조공정의 성능비교)

  • Sang-hong Jeong;Yun-seong Choi;Seung-Hwan Lee
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.38 no.3
    • /
    • pp.155-164
    • /
    • 2024
  • There are two primary sludge drying methods such as the direct heating microwave method and the indirect heating steam one. In this study, the drying treatment facility at sewage treatment plant A applied both of these drying methods. The research aimed to investigate the optimal operation approach for the drying facility, considering the input sludge and the moisture content data after the drying process. Moisture content and removal rate data were executed at the research facility from January 2016 to December 2018. First, the microwave, a direct heating drying method, performed intensive drying only on the outer surface of the sludge by directly applying heat to the sludge using far infrared rays, so effective sludge drying was not achieved. On the other hand, the steam method of the indirect heating method used steam from a gas boiler to maximize the utilization of the heat transfer area and reduce energy of the dryer, resulting in an effective sludge drying efficiency. The sludge moisture content brought into the sludge drying facility was about 80%, but the moisture content of the sludge that went through the drying facility was less than 10% of the design standard. Therefore, the steam method of the indirect heating method is more effective than the microwave method of the previous direct heating method and is more effective for maintenance It has proven that it is an efficient method of operating construction facilities.

Research on Improving Drying Technology For Sewage Waste Using Direct Flotation Using Heat Storage Media (축열메디아 활용 직접부상방식을 이용한 하수찌꺼기의 건조기술 향상에 관한 연구)

  • Sung-Il Noh;Ung-Yong Kim;Sung-Gyun Jo;Hyun-Gon Shin
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.31 no.4
    • /
    • pp.5-11
    • /
    • 2023
  • This study was conducted to improve energy efficiency and problems such as clumping and fouling in the glue zone that occur in the moisture content range of 40 to 60% when sewage dehydration residue is directly fed into the dryer. The temperature of the hot air is low at 270~300℃, and the paddle-type flotation method and dehydrated residue are applied to the circulated heat storage media to increase the contact area with the hot air, thereby reducing energy recovery and gas emissions. The water content of the dried residue is 2.7. ~7 .5%, the heat of evaporation of moisture was 608.0~690.6 kcal/kg·H2O, which confirmed an energy saving effect of about 8.8% compared to the heat of evaporation of moisture of 714.5 kcal/kg·H2O when no heat storage media was used.

Development of Display by Screen Printing and Heat-transfer (스크린 인쇄법 및 열 전사법에 의한 디스플레이 개발)

  • 이현철;남수용
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.20 no.1
    • /
    • pp.102-112
    • /
    • 2002
  • Cathode ray tubes (CRT) are the most common electronic display in use in information technology. The CRT consists of an electron gun, electrostatic or magnetic fields to direct the electron beam, and a phosphor screen. When the electron beam strikes the phosphor screen, the phosphor generates light. The phosphor screen has formed by precipitation method, electro-forming and centrifuge method. The high quality product was achieved by electro-forming or centrifuge method. Now applying method is electro-forming used with phosphor and Eh(isopropyl alcohol). Now applying method has been much consumption of raw-material, dirty working environment, dangerous fire and require of high cost. New method to form phosphor surface of monochrome is required to improve this matter. This study was developed novel method to form the phosphor surface by heat-transfer method. This method have advantages of simple process, automatization, clean environment, saving raw material and saving running-cost.

  • PDF

Cost Accounting of Heat and Electricity of a Combined Cycle Cogeneration System (복합열병합 시스템에 대한 열과 전기의 원가산정)

  • Kim Deok-Jin;Lee Keun-Whi
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.6
    • /
    • pp.560-568
    • /
    • 2005
  • The cost accounting of electricity and heat produced from an energy system is important in evaluating the economical efficiency and deciding the reasonable sale price. The OECOPC method, suggested by the author, was applied to a 650 MW combined cycle cogeneration system having 4 operating modes, and each unit cost of electricity and heat products was calculated. In case that a fuel cost is ${\\}400/kg$ and there are no direct and indirect cost, they were calculated as follows; electricity cost of ${\\}23,700/GJ$ at gas-turbine mode, electricity cost of ${\\}15,890/GJ$ at combined cycle mode, electricity cost of ${\\}14,146/GJ$ and heat cost of ${\\}6,466/GJ$ at cogeneration mode, and electricity cost of ${\\}14,387/GJ$ and heat cost of ${\\}4,421/GJ$ at combined cycle cogeneration mode. Further, these unit costs are applied to account benefit on this system. Since the suggested OECOPC method can be applied to any energy system, it is expected to contribute to cost accounting of various energy systems.

Simultaneous Consolidation of Titanium Diboride with Self-Propagating High-Temperature Synthesis, Direct Contact-Heating, and Pressure: Modeling of Temperature Distribution and the Relationship between Applied Energy and Densification ($TiB_2$ SHS 및 직접 접촉가열에 의한 동시 가압법 : 온도분포 모델링 및 공급에너지와 치밀화 관계)

  • Chung, G.K.;Cho, K.;Lee, H.B.
    • Journal of the Korean Ceramic Society
    • /
    • v.32 no.7
    • /
    • pp.817-824
    • /
    • 1995
  • TiB2 was simultaneously synthesized and densified with concurrent self-propagating high-temperature synthesis and direct contact-heating by electrcial power input and pressure. Density of TiB2 synthesized by self-propagating high-temperature synthesis and consolidated simultaneously by direct contact-heating and pressure was maximum 80% of the theoretical density (4.52g/㎤). Temperature profile was analyzed by solving heat balance equation with numerical method (FTCS method). The temperature of the sample was sufficiently raised to that temperature sufficient to be densified. It was ascertained that the density of the SHS synthesized TiB2 is exponentially proportinal to the input thermal energy per mass.

  • PDF

New Cooling System Design of BLDC Motor for Electric Vehicle Using Computation Fluid Dynamics Modeling

  • Vu, Duc Thuan;Hwang, Pyung
    • Tribology and Lubricants
    • /
    • v.29 no.5
    • /
    • pp.318-323
    • /
    • 2013
  • Overheating in electrical motors results in detrimental effects such as degradation of the insulation materials, demagnetization of magnets, increases in Joule losses, and decreases in motor efficiency and lifetime. Thus, it is important to find ways to dissipate heat from the motor and to keep the motor operating at its most efficient temperature. In this study, a new design to guide air flow through a given brushless direct current (BLDC) motor is developed and the design is analyzed, specifically by using computational fluid dynamics (CFD) simulations. The results showed that the temperature distribution in the three proposed models is lower than that in the original model, although the speed of the cooling fan in the original model reaches a very high value of $15{\times}10^3$ rpm. The results also showed that CFD can be effectively used to simulate the heat transfer of BLDC motors.

On the Optimum Modelization for a Spray Column Direct Contact Heat Exchanger (분사칼럼식 직접접촉 열교환기의 최적 모델링을 위한 연구)

  • Yoon, S.M.;Kang, Y.H.;Kim, C.B.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.3 no.1
    • /
    • pp.1-10
    • /
    • 1991
  • The purpose of this study is to lay groundwork for a complete analysis of two component flow by analyzing a single component flow made of continuous fluid without dispersed phase. In order to achieve uniform velocity distributions which are desirable in designing an optimum spray column direct contact heat exchanger, the influence of injection nozzle orientation has been investigated for axial and radial injections. The results that radial injection ensures more uniform velocity distributions compared to the axial case. The flow characteristics in a spray column have been investigated with various L/D values and inlet velocities, the most uniform internal velocity distributions have been obtained for the case of L/D=10 and 0.1m/sec. In the present investigation, it is shown that radial injection method for the continuous flow is advantageous in obtaining desirable uniform velocity distributions in a spray column. It is also found that as the value of L/D increases and the inlet velocity decreases, the flow improves to be better uniform velocity distributions.

  • PDF

Study on the Fire Suppression by Heat Transfer of Thermal Insulation Materials (건축물 외단열재의 열전달평가를 통한 화재 억제 방안 연구)

  • Ryu, Hwa Sung;Shin, Sang Hun;Song, sung young;Kim, Deuck Mo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.277-278
    • /
    • 2018
  • Improvement of insulation performance of buildings is a major part. Adiabatic method The adiabatic method minimizes the heat loss of the building. External insulation uses insulation to prevent fire. Ambient air hazards are less prone to fire. When a fire occurs, a phenolic pattern is formed and bond strength with the wall increases. EPS insulation and phenol foam were used to compare external heat transfer and external heat transfer. The heat transfer properties of phenolic foam and styrofoam were evaluated as follows. In the mortar and styrofoam structure, the problem of styrofoam reaching the burning point occurred before the collapse of the mortar, and the phenol foam had a problem in that when the direct fire was continued on the phenol foam. The characteristics of continuous infiltration appeared. In the case of mortar and phenol foam + styrofoam, the heat penetrated into the interior due to the shrinkage due to the shrinkage of the carbon screen on the phenol foam. However, when reinforced with glass mesh on the outer surface, And to reduce infiltration.

  • PDF

Sensitivity Analysis of Processing Parameters for the Laser Surface Hardening Treatment by Using the Finite Element Method (유한요소법을 이용한 레이저 표면경화처리 공정변수의 민감도 해석)

  • 이세환;양영수
    • Journal of Welding and Joining
    • /
    • v.19 no.2
    • /
    • pp.228-234
    • /
    • 2001
  • A methodology is developed and used to evaluate the response sensitivity of the thermal systems to variations in their design parameters. Technique for computing the sensitivity of temperature distributions to changes in processing parameters needed to decide the more effective laser input parameters for laser surface hardening treatment is considered. In this study, a state equation governing the heat flow in laser surface treatment is analyzed using a three-dimensional finite element method and sensitivity data of the processing parameter obtained using a direct differentiation method is applied to the sensitivity analysis. The interesting processing parameters are taken as the laser scan velocity and laser beam radius ( $r_{ b}$), and the sensitivities of the temperature T versus v and $r_{b}$ are analyzed. These sensitivity results are obtained with another parameters fixed. To verify the numerical analysis results, hardened layer dimensions (width and depth) of the numerical analysis are compared with the experimental ones.nes.

  • PDF

Boiling Heat Transfer Characteristics of $CO_2$ in Horizontal Smooth Microchannel (수평 microchannel의 $CO_2$ 비등열전달)

  • Choi, Kwang-Il;Ardiyansyah, Ardiyansyah;Oh, Jong-Taek
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.241-246
    • /
    • 2007
  • The present paper dealt with an experimental study of boiling heat transfer characteristics of $CO_2$. Heat transfer coefficients of the refrigerant flow inside horizontal smooth microchannel were obtained with inner tube diameter of 0.3mm and length of 300mm. The direct electric heating method was applied for supplying the heat uniformly to the refrigerant. The experiments were conducted with $CO_2$ purity of 99.99%, at saturation temperature of $10^{\circ}C$, mass flux ranges of $300{\sim}900\;kg/m^2s$, and heat flux ranges of $15{\sim}45\;kW/m^2$. While heat transfer coefficient increased with the increase of heat flux in the low quality region, the heat transfer coefficient decreased with the increase of quality in the high quality region. The heat transfer coefficients were compared with seven existing correlations with the Gungor-Winterton's(1986) correlation gave the best prediction. A new corelation to predict the two-phase flow heat transfer coefficient was developed based on the Chen(1966) correlation. The new correlation predicted the experimental data well with a mean deviation of 9.69% and average deviation of -3.03%.

  • PDF