• 제목/요약/키워드: direct comparison method

Search Result 589, Processing Time 0.029 seconds

Pseudo plastic zone analysis of steel frame structures comprising non-compact sections

  • Avery, P.;Mahendran, M.
    • Structural Engineering and Mechanics
    • /
    • v.10 no.4
    • /
    • pp.371-392
    • /
    • 2000
  • Application of "advanced analysis" methods suitable for non-linear analysis and design of steel frame structures permits direct and accurate determination of ultimate system strengths, without resort to simplified elastic methods of analysis and semi-empirical specification equations. However, the application of advanced analysis methods has previously been restricted to steel frames comprising only compact sections that are not influenced by the effects of local buckling. A concentrated plasticity method suitable for practical advanced analysis of steel frame structures comprising non-compact sections is presented in this paper. The pseudo plastic zone method implicitly accounts for the effects of gradual cross-sectional yielding, longitudinal spread of plasticity, initial geometric imperfections, residual stresses, and local buckling. The accuracy and precision of the method for the analysis of steel frames comprising non-compact sections is established by comparison with a comprehensive range of analytical benchmark frame solutions. The pseudo plastic zone method is shown to be more accurate and precise than the conventional individual member design methods based on elastic analysis and specification equations.

Analytical method to estimate cross-section stress profiles for reactor vessel nozzle corners under internal pressure

  • Oh, Changsik;Lee, Sangmin;Jhung, Myung Jo
    • Nuclear Engineering and Technology
    • /
    • v.54 no.1
    • /
    • pp.401-413
    • /
    • 2022
  • This paper provides a simple method by which to estimate the cross-section stress profiles for nozzles designed according to ASME Code Section III. Further, this method validates the effectiveness of earlier work performed by the authors on standard nozzles. The method requires only the geometric information of the pressure vessel and the attached nozzle. A PWR direct vessel injection nozzle, a PWR outlet nozzle, a PWR inlet nozzle and a BWR recirculation outlet nozzle are selected based on their corresponding specific designs, e.g., a varying nozzle radius, a varying nozzle thickness and an outlet nozzle boss. A cross-section stress profile comparison shows that the estimates are in good agreement with the finite element analysis results. Differences in stress intensity factors calculated in accordance with ASME BPVC Section XI Appendix G are discussed. In addition, a change in the dimensions of an alternate nozzle design relative to the standard values is discussed, focusing on the stress concentration factors of the nozzle inside corner.

Men's Work Clothes Jumper Pattern-making and Its Appearance Evaluation through 3-D Clothing Simulation (3차원 가상착의 시뮬레이션을 이용한 20~50대 연령별 남성 작업복 점퍼 패턴 설계 및 외관평가)

  • Park, Gin-Ah;Lee, Woo-Kyoung
    • Journal of Fashion Business
    • /
    • v.16 no.1
    • /
    • pp.103-120
    • /
    • 2012
  • The study aimed to evaluate the appearance of the men's work clothes jumpers developed to suggest the prototype work clothes jumper patterns by using the 3-D clothing simulation technology. The 3-D simulated clothing images considered the upper body features of men in the age range between 20 and 59 in South Korea. A questionnaire survey conducted previously suggested a basic jumper style with shirt collar and snap opening cuffs for the heavy industry workers; and discomforting parts of the work clothes jumper of the subject workers have been referred to for the experimental jumper appearance test. Besides, defining the measurements of men's upper bodies enabled to generate the men's 3-D virtual models representing each age group's average body feature. The significant body measurement factors for men's 3-D body modeling and jumper pattern-making were stature for the height factor; chest, waist and hip circumferences for the circumference factor; waist back, hip and arm lengths and interscye front/back for the length factor; and back neck breadth for the breadth factor and armscye and scye depths for the depth factor. The men's body measurements of 30's were implemented to three experimental jumper pattern-making methods, i.e. the 1st method using the relations based on stature and chest circumference; the 2nd method using the direct body measurements; and the 3rd method adopting the maximum ease amount of given body measurements whether relations or direct measurements except the direct measurement of scye depth. A comparison among the three experimental jumpers' simulated images highlighted that the appropriate ease amount of the jumper gained higher scores in terms of the jumpers' front, side, back and sleeve parts and the total silhouettes. Therefore the 3rd experimental jumper was finally selected for the heavy industry workers.

Comparison of the I-V Characteristic as Various Composition ratio of Iodine in a-Se of $BrO_2/a-Se$ based Radiation Conversion Sensor ($BrO_2/a-Se$ 구조의 방사선 변환센서에서 a-Se에 첨가된 조성비 변화에 따른 I-V 특성 비교)

  • Choi, Jang-Yong;Park, Ji-Koon;Gong, Hyun-Gi;Ahn, Sang-Ho;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.440-443
    • /
    • 2002
  • Present1y the X-Ray diagnosis system is a real condition that is changing by digital ways in it's existent analog ways. This digital radiation detector is divided by the direct method and the indirect method. The indirect method of applied voltage has special qualities that the resolution is low than direct method by diffusion effect that happens. The conversion process ( radiation${\rightarrow}$visible ray${\rightarrow}$electrical signal of two times, has shortcomings that the energy conversion efficiency of electrical signal is low. The direct method has shortcomings that need strong electric fie1d to detect electrical signal efficiently. This research achieved to develop digital detector of the Hybrid method that have form that mixes two ways to supplement shortcoming of direct. indirect method. A studied electrical characteristic by Iodine's Mixture ratio change is added to selenium in the detector which has a multi-layer structure (Oxybromide + a-Se). There are 8 kinds of Manufactured compositions to amorphous selenium Iodine each 30ppm, 100ppm, 200 ppm, 300ppm, 400ppm, 500ppm, 600ppm, 700ppm by a doped photoconductor through a vacuum thermal evaporation method. The phosphor layer is consisted of Oxybromide ($BrO_2$) which uses optical adhesives multi-layer structure. The manufactured compositions calculates and compares Net Charge and signal to noise ratio measuring Photocurrent about Darkcurrent and X-ray. When doped Iodine Mixture ratio is 500ppm to the multi-layer structure (Oxybromide + a-Se), applied voltage of $3V/{\mu}m$, leakage current of compositions $2.61nA/cm^2$ and net charge value by 764pC/$cm^2$/mR then the best result appeared.

  • PDF

Comparison Between DCM and Quaternion Transformation in Lever Arm Compensation of Reference System for Flight Performance Evaluation of DGPS/INS

  • Park, Ji-Hee;Shin, Dong-Ho
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.1 no.1
    • /
    • pp.45-49
    • /
    • 2012
  • The flight performance evaluation of navigation system is very significant because the reliability of navigation data directly affect the safety of aircraft. Especially, the high-level navigation system such as DGPS/INS, need more precise flight performance evaluation method. The performance analysis is evaluated by comparing between the navigation system in aircraft and reference trajectory which is more precise than navigation system in aircraft. In order to verify DGPS/INS performance of m-level, the GPS receiver, which is capable post-processed Carrier-phase Differential GPS(CDGPS) method of cm-level, have to be used as reference system. The DGPS/INS is estimated the Center of Gravity (CG) point of aircraft to offer precise performance while the reference system is output the position of GPS antenna which is mounted on the outside of aircraft. Therefore, in order to more precise performance evaluation, it needs to compensate the lever arm and coordinates transformation. This paper use quaternion and Direct Cosine Matrix(DCM) methods as coordinate transformation matrix in lever arm compensation of CDGPS reference trajectory. And it compares NED errors of DCM and quaternion transformation in lever arm of reference trajectory via DGPS/INS result.

Development of a Computer Vision System to Measure Low Flow Rate of Solid Particles (컴퓨터 시각에 의한 고형 입자의 소량 유동율 측정장치 개발)

  • 이경환;서상룡;문정기
    • Journal of Biosystems Engineering
    • /
    • v.23 no.5
    • /
    • pp.481-490
    • /
    • 1998
  • A computer vision system to measure low flow rate of solid particles was developed and tested to examine its performance with various sized 7 kinds of seeds, perilla, mung bean, paddy, small red bean, black soybean, Cuba bean and small potato tuber. The test was performed for two types of particle flow, continuous and discontinuous. For the continuous flow tested with perilla, mung bean and paddy, the tests resulted correlation coefficients for the flow rates measured by the computer vision and direct method about 0.98. Average errors of the computer vision measurement were in a range of 6∼9%. For the discontinuous flow tested with small red bean, black soybean, Cuba bean and small potato tuber, the tests resulted correlation coefficients for the flow rates measured by the computer vision and direct method 0.98∼0.99. Average errors of the computer vision measurement were in a range of 5∼10%. Performance of the computer vision system was compared with that of the conventional optical sensor to count particles in discontinuous flow. The comparison was done with black soybean, Cuba bean and small potato tuber, and resulted that the computer vision has much better performance than the optical sensor in a sense of precision of the measurement.

  • PDF

High Performance Electrode of Polymer Electrolyte Membrane Fuel Cells Prepared by Direct Screen Printing Process (직접 스크린 프린팅법으로 제조된 고분자 전해질 연료전지의 고성능 전극)

  • 임재욱;최대규;류호진
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.11 no.1
    • /
    • pp.65-69
    • /
    • 2004
  • Screen printing it one of the most popular methods for the fabrication of catalytic layer in electrode of polymer electrolyte membrane fuel cells (PEMFCs) due to its convenience and adaptability. This paper suggests an improved screen-printing method, which is rather simple suppressing the swelling trouble without additive process and competitive with very low Pt loading in comparison with the previous methods. Particularly, the gasket unified MEA made better performances than the other especially at high current area due to blocking effect on the gas leakage during the operation. These methods give us more simplified and faster fabrication chances.

  • PDF

Comparison of the LNT Regeneration Methods in 2.2L Common Rail Direct Injection Diesel Engine (2.2L 직분사 디젤 엔진에서 LNT 촉매 재생을 위한 환원제 분사 방법 비교)

  • Nam, Chungwoo;Han, Manbae
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.23 no.2
    • /
    • pp.169-177
    • /
    • 2015
  • In this study we investigated the regeneration methods for the lean $NO_x$ trap (LNT) catalyst in a 2.2L direct injection diesel engine. The regeneration methods were 1) in-cylinder post fuel injection and 2) external fuel injection strategy. The in-cylinder post fuel injection method uses in-cylinder injectors with the addition of the post fuel injection to supply enough reductants such as CO, $H_2$, THC. The external fuel injection method was enabled by installing a fuel injector with a wide spray angle before the LNT catalyst. Through the engine experiment, the $NO_x$ conversion efficiency, the amount of reductant exhaust gases, fuel consumption, and temperature behavior in the LNT catalyst were evaluated and compared for the two regeneration methods.

TECHNIQUES FOR INTERGRANULAR CRACK FORMATION AND ASSESSMENT IN ALLOY 600 BASE AND ALLOY 182 WELD METALS

  • LEE, TAE HYUN;HWANG, IL SOON;KIM, HONG DEOK;KIM, JI HYUN
    • Nuclear Engineering and Technology
    • /
    • v.47 no.1
    • /
    • pp.102-114
    • /
    • 2015
  • Background: A technique developed to produce artificial intergranular stress corrosion cracks in structural components was applied to thick, forged alloy 600 base and alloy 182 weld metals for use in the qualification of nondestructive examination techniques for welded components in nuclear power plants. Methods: An externally controlled procedure was demonstrated to produce intergranular stress corrosion cracks that are comparable to service-induced cracks in both the base and weld metals. During the process of crack generation, an online direct current potential drop method using array probes was used to measure and monitor the sizes and shapes of the cracks. Results: A microstructural characterization of the produced cracks revealed realistic conformation of the crack faces unlike those in machined notches produced by an electrodischarge machine or simple fatigue loading using a universal testing machine. Conclusion: A comparison with a destructive metallographic examination showed that the characteristics, orientations, and sizes of the intergranular cracks produced in this study are highly reproducible.

A Study on Characteristics of Sensory Richness Towards Healing Environments at the Lobby of Geriatric Hospital Using Biophilic Design Approach (바이오필릭 디자인에 기반한 노인요양병원 로비공간의 다감각적 치유환경에 관한 연구)

  • Lee, Dami;Lee, Hyunsoo
    • Korean Institute of Interior Design Journal
    • /
    • v.25 no.3
    • /
    • pp.21-30
    • /
    • 2016
  • For the elderly with declining sensory due to aging, various sense stimulation factors provided in indoor environment is desirable healing environment. This study aims to propose the direction of sensory healing environment by adapting the richness of natural environment in indoor place based on the biophilic design theory with implementation method of sensory richness environment. The healing environment was limited to the ward in the beginning, but it has widened its range to the whole place, and the lobby is considered quiet important to healing. Therefore, this study selected lobby space of geriatric hospital as study subject. As for the study method, we deducted the analytic matrix focusing on the property and elements of the direct and indirect experience of nature appearing in the biophilic design theory, and analyzed the field investigation of subject space. Also, this study paid attention to point where the hotel lobby leads the change of emotional environment, and conducted analysis and comparison by deciding this is what the hotel and geriatric hospital should direct to. As the result, the biophilic design factor of hotel is actively expressed by complex direction of various factors, but as for the geriatric hospital, it was rather passive and simple in expression. The adaptation ratio between hotel and geriatric hospital was almost more than twice times difference in average.