Comparison of Three Different Methods for Campylobacter Isolation from Porcine Intestines

  • Shin, Eun-Ju;Lee, Yeon-Hee
    • Journal of Microbiology and Biotechnology
    • /
    • v.19 no.7
    • /
    • pp.647-650
    • /
    • 2009
  • Using 200 porcine colon tissues, the efficiencies of three isolation methods of Campylobacter from porcine intestines were compared: Method 1, direct streaking of colon mucosa; Method 2, direct inoculation of intestinal contents with a swab; Method 3, inoculation of pre-enriched medium. A total of 460 Campylobacter isolates were obtained from 178 samples (89%) by direct streaking of colon mucosa, 142 samples (71%) by direct streaking of a swab, and 94 samples (47%) by pre-enrichment of intestinal contents in Preston broth. Direct streaking of colon mucosa was superior to the other two isolation methods, in terms of rapidity and higher efficiency. When isolates were identified with various biochemical tests and PCRs specific to 16s rRNA, mapA, and ceuE, C. coli was the predominant species (87%) in porcine, whereas the rest of the isolates were identified as C. lanienae.

Analysis and comparison of the 2D/1D and quasi-3D methods with the direct transport code SHARK

  • Zhao, Chen;Peng, Xingjie;Zhang, Hongbo;Zhao, Wenbo;Li, Qing;Chen, Zhang
    • Nuclear Engineering and Technology
    • /
    • v.54 no.1
    • /
    • pp.19-29
    • /
    • 2022
  • The 2D/1D method has become the mainstream of the direct transport calculation considering the balance of accuracy and efficiency. However, the 2D/1D method still suffers from stability issues. Recently, a quasi-3D method has been proposed with axial Legendre expansion. Analysis and comparison of the 2D/1D and quasi-3D method is conducted in theory from the equation derivation. Besides, the C5G7 benchmark, the KUCA benchmark and the macro BEAVRS benchmark are calculated to verify the theory comparisons of these two methods with the direct transport code SHARK. All results show that the quasi-3D method has better stability and accuracy than the 2D/1D method with worse efficiency and memory cost. It provides a new option for direct transport calculation with the quasi-3D method.

Performance Comparison According to Image Generation Method in NIDS (Network Intrusion Detection System) using CNN

  • Sang Hyun, Kim
    • International journal of advanced smart convergence
    • /
    • v.12 no.2
    • /
    • pp.67-75
    • /
    • 2023
  • Recently, many studies have been conducted on ways to utilize AI technology in NIDS (Network Intrusion Detection System). In particular, CNN-based NIDS generally shows excellent performance. CNN is basically a method of using correlation between pixels existing in an image. Therefore, the method of generating an image is very important in CNN. In this paper, the performance comparison of CNN-based NIDS according to the image generation method was performed. The image generation methods used in the experiment are a direct conversion method and a one-hot encoding based method. As a result of the experiment, the performance of NIDS was different depending on the image generation method. In particular, it was confirmed that the method combining the direct conversion method and the one-hot encoding based method proposed in this paper showed the best performance.

A Comparison of the Direct Shear Test and Shear Simulation Based on the Discrete Element Method (직접전단시험과 이산요소법에 기반한 전단 시뮬레이션과의 비교)

  • Jung, Sung-Heon;Sohn, Jeong-Hyun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.3
    • /
    • pp.86-91
    • /
    • 2020
  • An important factor of rough road modeling is analyzing the shear behavior properties of the rough road. These properties influence the drawbar pull of the tool when interacting with the soil used in agriculture. Furthermore, shear behavior properties are important because sinkage and shear stress are generated when wheels drive on rough roads. In this study, we performed a direct shear test to investigate the shear behavior properties of soils and compare with the direct shear simulation; shear force derived by the coupled analysis of discrete element method; and multi-body dynamics. Soil contact parameters were measured in a wheel and soil contact simulation followed by comparison of the simulated and experimentally measured shear force.

Direct strength method for high strength steel welded section columns

  • Choi, Jong Yoon;Kwon, Young Bong
    • Steel and Composite Structures
    • /
    • v.29 no.4
    • /
    • pp.509-526
    • /
    • 2018
  • The direct strength method adopted by the AISI Standard and AS/NZS 4600 is an advanced design method meant to substitute the effective width method for the design of cold-formed steel structural members accounting for local instability of thin plate elements. It was proven that the design strength formula for the direct strength method could predict the ultimate strength of medium strength steel welded section compressive and flexural members with local buckling reasonably. This paper focuses on the modification of the direct strength formula for the application to high strength and high performance steel welded section columns which have the nominal yield stress higher than 460 MPa and undergo local buckling, overall buckling or their interaction. The resistance of high strength steel welded H and Box section columns calculated by the proposed direct strength formulae were validated by comparison with various compression test results, FE results, and predictions by existing specifications.

Comparison of Ultrasonic Velocities between Direct and Indirect Methods on 30 mm × 30 mm Spruce Lumber

  • OH, Sei Chang
    • Journal of the Korean Wood Science and Technology
    • /
    • v.48 no.4
    • /
    • pp.562-568
    • /
    • 2020
  • This study investigates the relationship between ultrasonic velocity and density in the direct method, the effect of distance between transducers in the indirect method, and the difference between the direct and indirect methods with transducers placed at a distance of 200 mm in nondestructive ultrasonic testing of spruce lumber. The direct method using 54 kHz ultrasonic transducers was applied to two planes, namely, radial section (LR) and tangential section (LT) of samples. The indirect method measurements were taken using the same transducers. Two velocities were measured at the top and bottom of the LT plane and at the two sides of the LR plane; the two values for each plane were averaged. The relationship between density and ultrasound velocity in the direct method demonstrated a positive correlation between the two variables. The difference between the two planes, LT and LR, was not statistically significant. Moreover, the distance between the transducers in the indirect method affected ultrasound velocity, with the ultrasonic velocity increasing as the distance between the transducers became larger. A transducer distance of 200 mm yielded a close approximation of the direct method results with a ratio of 0.87. Finally, no statistical evidence of a difference between the two planes in the indirect method was found. If the direct method, which requires access to two surfaces, is impractical, the indirect method can be applied.

A New Direct Torque Control Method of Induction Motor for Torque Ripple Reduction

  • Kim, Deok-Ki;Kim, Jong-Su;Kim, Sung-Hwan;Kim, Hyun-Soo;Kim, Won-Ouk;Yoon, Kyoung-Kuk;Oh, Sae-Gin
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.7
    • /
    • pp.1061-1067
    • /
    • 2008
  • Direct Torque Control[DTC] and Vector Control are the two schemes developed for high performance induction motor drives. DTC based induction motors are being increasingly used in various industrial applications. DTC offers fast torque response and better speed control with lesser hardware and processing costs as compared to vector controlled drives. However, conventional DTC suffers from high torque ripple, current harmonics and low performance during torque transients. In this paper a new Direct Torque Control[DTC] method of induction motor is presented. In comparison with the conventional DTC method, the PWM technique is applied to proposed control method. In this method, decoupling mechanism is not required and the torque, the flux magnitude are under control using PI controllers and generating the voltage command for inverter control. Therefore torque and speed ripple could be reduced in comparison with the conventional switching table DTC.

PERFORMANCE COMPARISON OF PRECONDITIONED ITERATIVE METHODS WITH DIRECT PRECONDITIONERS

  • Yun, Jae Heon;Lim, Hyo Jin;Kim, Kyoum Sun
    • Journal of applied mathematics & informatics
    • /
    • v.32 no.3_4
    • /
    • pp.389-403
    • /
    • 2014
  • In this paper, we first provide comparison results of preconditioned AOR methods with direct preconditioners $I+{\beta}L$, $I+{\beta}U$ and $I+{\beta}(L+U)$ for solving a linear system whose coefficient matrix is a large sparse irreducible L-matrix, where ${\beta}$ > 0. Next we propose how to find a near optimal parameter ${\beta}$ for which Krylov subspace method with these direct preconditioners performs nearly best. Lastly numerical experiments are provided to compare the performance of preconditioned iterative methods and to illustrate the theoretical results.

Analysis of Fingerprint Recognition Characteristics Based on New CGH Direct Comparison Method and Nonlinear Joint Transform Correlator

  • Jeong, Man-Ho
    • Journal of the Optical Society of Korea
    • /
    • v.13 no.4
    • /
    • pp.445-450
    • /
    • 2009
  • Fingerprint recognition using a joint transform correlator (JTC) is the most well-known technology among optical fingerprint recognition methods. The JTC method optically compares the reference fingerprint image with the sample fingerprint image then examines match or non-match by acquiring a correlation peak. In contrast to the JTC method, this paper presents a new method to examine fingerprint recognition by producing a computer generated hologram (CGH) of those two fingerprint images and directly comparing them. As a result, we present some parameters to show that fingerprint recognition capability of the CGH direct comparison method is superior to that of the JTC method.

Comprision Study of Measure Method on Leveling (수준측량 측정방법의 비교연구)

  • Hwang, Jin-Sung
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.16 no.1
    • /
    • pp.9-13
    • /
    • 2013
  • This paper measured some condition about differential height of two points for the comparison of measure by direct method and Geodimeter and trigonometric Leveling method. The research was compared relationship between the volue to get from three measure method and five measured man. The significance of between three measure method and five measured man has been investigated by analysis of two-way ANOVA. The result indicate that between five measured man show insignficance, and between the direct method and Geodeter method show signficance and between the direct method and trigonometric Leveling method show signficance but between the Geodeter method and trigonometric Leveling method, two method show insignficant. Therefore, when using Geodemeter leveling method and trigonometric Leveling method, you must keep particular attention when former two Leveling method about instrumental error, natural error, and personal error, two Leveling method using low precision leveling.