• Title/Summary/Keyword: direct bypass

Search Result 103, Processing Time 0.025 seconds

Ruptured Aneurysm of Sinus Valsalva (대동맥 동맥루 파열 9례 보고)

  • Yoon, Yu-Joon;Cho, Bum-Koo;Hong, Seung-Nok
    • Journal of Chest Surgery
    • /
    • v.11 no.4
    • /
    • pp.373-377
    • /
    • 1978
  • Aneurysmal rupture of sinus Valsalva is known as one of rare cardiac disease and not controlled with medical treatment. We experienced 9 cases which were composed with 7 case of male and 2 cases of female during last 15 years. 7 cases were ruptured into right ventricle from right. coronary sinus and 2 cases were ruptured into right atrium from non-coronary sinus. The diagnosis was made with cardiac catheteriza1icn and cineangiccardicgram but 2 cases were misdiagnosed with only cardiac catheterization. All cases were corrected under cardiopulmonary bypass with means of direct suture with tdlon pledget by transatrial or transventricular approach. All were not confirmed in it's origin because of no history, no evidences of syphilis, TB, or bacterial endocarditis and only fibrosis in pathologic report. In postoperative course, 1 case had postoperative bleeding and 1 case was sufferd from left hemiplegia due to may be air embolism. Follow up study revealed all patient go on their usual life well with good improvement at this present time.

  • PDF

A Study on Boost Type Single-Phase Inverter System for Compensation of Voltage Sag (Voltage Sag 보상을 위한 승압형 단상 인버터 시스템에 관한 연구)

  • Seo, Young-Min;Lee, Seung-Yong;Hong, Soon-Chan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.11
    • /
    • pp.50-57
    • /
    • 2011
  • This paper proposes a boost type single-phase inverter system to compensate the voltage sag appeared on source side. The proposed system is composed of a boost converter, a PWM inverter, and a bypass diode. If the voltage sag has appeared in input voltage, the boost converter would be operated to compensate it in the proposed system. The boost converter would not be operated when the magnitude of input voltage is more than 0.9 pu. The output voltage is kept constant by a direct-quadrature frame controller in the inverter. A 300 W class boost type inverter system was simulated, and the validity of the proposed system was verified by carrying out experiments.

Reduction of Heat Generation from Junction Box in 3 kW Photovoltaic Power Generation System

  • Yun, Jung-Hyun;Sun, Ki-Ju;Cheon, Min-Woo
    • Transactions on Electrical and Electronic Materials
    • /
    • v.17 no.1
    • /
    • pp.21-24
    • /
    • 2016
  • A junction box used in a 3 kW photovoltaic power generation system plays a role in collecting and supplying the direct current voltage produced by photovoltaic modules to an inverter. It is also used for facilitating maintenance checks and protecting the module and inverter by keeping the voltage constant. As for the junction box, using it in a parallel connection creates a difference between the setup modules. In order to compensate, an inverse voltage diode is used. But the high-power created through the solar generator can be delivered to the inverter through the inverter regularly. Therefore, a component can break down due to excess heat. And consequently short circuits and electric leakage occurs. In this study, using a junction box that enabled the bypass of high electric power, it was possible to reduce heat generation by approximately 35℃ when compared to a standard junction box.

Left ventricular-right atrial shunt associated with PDA: a case report (동맥관개존증을 동반한 좌심실-우심방 단락 치험 1례)

  • Sin, Gi-U;Kim, Sang-Hyeong;Lee, Dong-Jun
    • Journal of Chest Surgery
    • /
    • v.16 no.3
    • /
    • pp.316-321
    • /
    • 1983
  • Left ventricular-right atrial [LV-RA] shunt is a relatively uncommon defect but is being encountered with increasing frequency. The diagnosis is often not suspected on the basis of clinical findings and so the specific anatomic diagnosis depends upon the use of selective left ventriculography. Recently we experienced LV-RA shunt associated with PDA, which was underwent successful surgical correction under the cardiopulmonary bypass. On the preoperative diagnosis coexistence of PDA was overlooked and identified at the time of operation. The type of LV-RA shunt was supravalvular, which was closed by direct suture with pledget.

  • PDF

Right Ventricle Perforation Caused by the Sternal Fracture .A Case Report (흉골골절에 의한 우심실 파열 치험 1례 보고)

  • 김정철;오상준
    • Journal of Chest Surgery
    • /
    • v.29 no.12
    • /
    • pp.1398-1400
    • /
    • 1996
  • The cardiac anatomic position immediately beneath the sternum leaves it vulnerable to injury when this bone is fractured. Cardiac rupture, however, is uncommon but survival following this injury is rare. We report the case of one patient who survived right ventricle perforation resulting from sternal fracture. The patient developed signs of pericardial tamponade and was brought to the operating theatre immediately for surgery through the emergency anterolateral thoracotomy Perforation of th right ventricle was repaired by direct closure without cardiopulmonary bypass. We believe that patients with cardiac rupture who reach the hospital alive can often be saved by prompt diagnosis and surgery.

  • PDF

Improved Self Plasma-Optical Emission Spectroscopy for In-situ Plasma Process Monitoring (실시간 플라즈마공정 모니터링을 위한 Self Plasma-Optical Emission Spectroscopy 성능 향상)

  • Jo, Kyung Jae;Hong, Sang Jeen
    • Journal of the Semiconductor & Display Technology
    • /
    • v.16 no.2
    • /
    • pp.75-78
    • /
    • 2017
  • We reports improved monitoring performance of Self plasma-optical emission spectroscopy (SP-OES) by augmenting a by-pass tube to a conventional straight (or single) tube type self plasma reactor. SP-OES has been used as a tool for the monitoring of plasma chemistry indirectly in plasma process system. The benefits of SP-OES are low cost and easy installation, but some semiconductor industries who adopted commercialized SP-OES product experiencing less sensitivity and slow sensor response. OH out-gas chemistry monitoring was performed to have a direct comparison of a conventional single type tube and a by-pass type tube, and fluid dynamic simulation on the improved hardware design was also followed. It is observed faster pumping out of OH from the chamber in the by-pass type SP-OES.

  • PDF

Baby Lazarus: Listening to the Rebirths in "Lady Lazarus"

  • Lee, Jaehoon
    • American Studies
    • /
    • v.43 no.2
    • /
    • pp.83-110
    • /
    • 2020
  • This paper examines the meaning and significance of the rebirths narrated in Sylvia Plath's "Lady Lazarus." While the previous readings of the poem have regarded the speaker's rebirth as a single event, this paper aims to understand its plurality and the underlying problem of language and sound by listening to the poet's own reading of the poem. I argue first that the sound structure of the poem can be characterized by the poet's unique employment of vowel sounds. Drawing upon Plath's another poem entitled "Morning Song" and Julia Kristeva's concept of the chora, I contend that the poet's vowels signal her desire for regression to the pre-Oedipal space where sound and body are in direct contact without the interference of language. It is my conclusion that the rebirths in "Lady Lazarus" dramatize the poet's ongoing struggle to bypass the symbolic language in order to make her body heard.

Effect of Fructose-1,6-diphosphate[FDP] on Red Blood Cells after Extracorporeal Circulation (체외순환후 fructose-1,6-diphosphatate[FDP]가 적혈구에 미치는 영향)

  • 이정렬
    • Journal of Chest Surgery
    • /
    • v.25 no.7
    • /
    • pp.693-701
    • /
    • 1992
  • Extracorporeal cardiopulmonary bypass[CPB] has been associated with a wide variety of hematologic derangements, including a transient deformation and hemolysis of red blood cells[RBCs], which is supposed to be due to mechanical trauma and/or metabolic alterations. Since membrane integrity is, in part, maintained by energy requiring process, inadequate function of erythrocyte glycolytic pathway, which is inevitalble during CPB, may cause depletion of high energy phosphate pool and result in hemolysis. The authors performed an investigation to assess whether administration of Fructose-l, 6-diphsphate [FDP], which has been known to enhance intracellular glycolytic activities, could counteract erythrocyte hemolytic events caused by CPB. Sixty pateints with cyanotic congenital heart diseases, who underwent open heart surgery under CPB longer than 60 minutes, were randomly divided into two groups depending on whether use of FDP[Group FDP] or not[Group Control]. The age, sex, CPB time, preoperative hemoglobin level, disease entities were all similar[Table 1], and membrane type oxygenators were used in all patients. In Group, FDP, a dose of 250mg/kg body weight of FDP was administered by intravenous dripping every 12 hours from the morning of the operation to postoperative 48 hours, To demonstrate the degree and pattern of hemolysis of erythrocyte, reticulocyte count, indirect /direct bilirubin, haptoglobin, plasma hemoglobin, lactate dehydrogenase were measured every 12 hours from the time of cessation of CPB to 48 hours and RBC morphologic study, osmotic fragility test were done every 24 hours. All parameters revealed less hemolytic in group FDP [Fig. 1~5], though the differences between two groups were not significant, except plasma hemoglobin, lactate dehydrogenase changes. A pattern of sequential changes of plasma hemoglobin, lactate deh-ydrogenase showed the highest level at the time of CPB stop and abrupt decrease in following 24 hours in both groups, and statistically significant differences were demonstrated in group FDP at least for the first 12 hours postoperatively[p<0.05]. The authors conclude that they can expect the benificial effect of FDP on the maintenance of membrane stability of RBC probably by energy enhancement during the shock status of CPB, but FDP could not completely prevent the damaging effect on RBC by cardiopulmonary bypass

  • PDF

Direct reprogramming of fibroblasts into diverse lineage cells by DNA demethylation followed by differentiating cultures

  • Yang, Dong-Wook;Moon, Jung-Sun;Ko, Hyun-Mi;Shin, Yeo-Kyeong;Fukumoto, Satoshi;Kim, Sun-Hun;Kim, Min-Seok
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.24 no.6
    • /
    • pp.463-472
    • /
    • 2020
  • Direct reprogramming, also known as a trans-differentiation, is a technique to allow mature cells to be converted into other types of cells without inducing a pluripotent stage. It has been suggested as a major strategy to acquire the desired type of cells in cell-based therapies to repair damaged tissues. Studies related to switching the fate of cells through epigenetic modification have been progressing and they can bypass safety issues raised by the virus-based transfection methods. In this study, a protocol was established to directly convert fully differentiated fibroblasts into diverse mesenchymal-lineage cells, such as osteoblasts, adipocytes, chondrocytes, and ectodermal cells, including neurons, by means of DNA demethylation, immediately followed by culturing in various differentiating media. First, 24 h exposure of 5-azacytidine (5-aza-CN), a well-characterized DNA methyl transferase inhibitor, to NIH-3T3 murine fibroblast cells induced the expression of stem-cell markers, that is, increasing cell plasticity. Next, 5-aza-CN treated fibroblasts were cultured in osteogenic, adipogenic, chondrogenic, and neurogenic media with or without bone morphogenetic protein 2 for a designated period. Differentiation of each desired type of cell was verified by quantitative reverse transcriptase-polymerase chain reaction/western blot assays for appropriate marker expression and by various staining methods, such as alkaline phosphatase/alizarin red S/oil red O/alcian blue. These proposed procedures allowed easier acquisition of the desired cells without any transgenic modification, using direct reprogramming technology, and thus may help make it more available in the clinical fields of regenerative medicine.

Clinical Results of Ascending Aorta and Aortic Arch Replacement under Moderate Hypothermia with Right Brachial and Femoral Artery Perfusion

  • Kim, Jong-Woo;Choi, Jun-Young;Rhie, Sang-Ho;Lee, Chung-Eun;Sim, Hee-Je;Park, Hyun-Oh
    • Journal of Chest Surgery
    • /
    • v.44 no.3
    • /
    • pp.215-219
    • /
    • 2011
  • Background: Selective antegrade perfusion via axillary artery cannulation along with circulatory arrest under deep hypothermia has became a recent trend for performing surgery on the ascending aorta and aortic arch and when direct aortic cannulation is not feasible. The authors of this study tried using moderate hypothermia with right brachial and femoral artery perfusion to complement the pitfalls of single axillary artery cannulation and deep hypothermia. Materials and Methods: A retrospective analysis was performed on 36 patients who received ascending aorta or aortic arch replacement between July 2005 and May 2010. The adverse outcomes included operative mortality, permanent neurologic dysfunction and temporary neurologic dysfunction. Results: Of these 36 patients, 32 (88%) were treated as emergencies. The mean age of the patients was 61.9 years (ranging from 29 to 79 years) and there were 19 males and 17 females. The principal diagnoses for the operation were acute type A aortic dissection (31, 86%) and aneurysmal disease without aortic dissection (5, 14%). The performed operations were ascending aorta replacement (9, 25%), ascending aorta and hemiarch replacement (13, 36%), ascending aorta and total arch replacement (13, 36%) and total arch replacement only (1, 3%). The mean cardiopulmonary bypass time was $209.4{\pm}85.1$ minutes, and the circulatory arrest with selective antegrade perfusion time was $36.1{\pm}24.2$ minutes. The lowest core temperature was $24{\pm}2.1^{\circ}C$. There were five deaths within 30 post-op days (mortality: 13.8%). Two patients (5.5%) had minor neurologic dysfunction and six patients, including three patients who had preoperative cerebral infarction or unconsciousness, had major neurologic dysfunction (16.6%). Conclusion: When direct aortic cannulation is not feasible for ascending aorta and aortic arch replacement, the right brachial and femoral artery can be used as arterial perfusion routes with the patient under moderate hypothermia. This technique resulted in acceptable outcomes.