• 제목/요약/키워드: dipole electric field

검색결과 95건 처리시간 0.021초

반무한 전기 쌍극자층에 의한 정전계 해석과 앙페르 법칙에 자계와 커패시터의 누설 전계간의 이중성 유사 관계 (Electrostatic field of the semi-infinite electric dipole layer as (a) dual analogy to the Ampere's law (b) capacitor's fringing field)

  • 조영기;;손혁우;김현덕;유형석
    • 전기학회논문지
    • /
    • 제61권4호
    • /
    • pp.606-611
    • /
    • 2012
  • The similarity, analogy and equivalence between the phenomenon due to electric and magnetic dipoles have been discussed in the open literature for different situations. Here we are presenting the numerical proof of the trajectory of leakage electric field due to a semi-infinite electric dipole layer in the external periphery and the electric field in the space between oppositely charged surfaces. The result is also valid for the fringing electric field of a parallel plate capacitor. The result is also proved to be a dual of Amp$\grave{e}$re's law in the electrostatics due to a semi-infinite electric dipole layer.

Near Fields around Metallic Walls due to a Nearby Dipole Source with Applications to EMC

  • Kim, Ki-Chai;Lim, Sung Min;Kim, Jong-Woo
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권1호
    • /
    • pp.329-334
    • /
    • 2017
  • This paper discusses the near field characteristics of a dipole source located near conducting metallic walls from an electromagnetic compatibility (EMC) point of view. An integral equation for a dipole source near a metallic wall is derived and solved by applying Galerkin's method of moments (MoM). The results show that in the regions outside the dipole source, total electric near fields decrease gradually in magnitude with an increasing field point from the dipole source. But in the regions inside the dipole source, total electric near fields decrease rapidly with a dipole position of $h{\leq}0.3{\lambda}$. For a dipole position of $h{\geq}0.7{\lambda}$, the peaks and nulls of the total near electric field occur periodically in the regions inside the dipole source, and the fluctuation period is almost $0.5{\lambda}$. The worst position for a receptor location is along the z-axis, and a range of a half-magnitude of the maximum near electric field in the principal H-plane is about two times broader than that of the principal E-plane. Experimental measurements are also presented to validate the theory.

가전기기에서 발생되는 극저주파 과도자계 예측기법 연구 (Study on Prediction Method for ELF Transient Magnetic Field from Home Appliances)

  • 주문노;양광호;명성호;민석원
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제51권11호
    • /
    • pp.616-621
    • /
    • 2002
  • With biological effects by ELF (Extremely Low Frequency) magnetic field generated from power system, the transient magnetic field from electric appliances is a major issue presently. Because the transient magnetic field induces higher current than the power frequency field inside living bodies, transient magnetic field exposure has been much focused. In this paper, it is shown that transient magnetic field from electric home appliances can be characterized as magnetic dipole moment. In this method, the dipole moment vector is assumed by allowing an uncertainty of 6dB in the estimated field. A parameter M that represents biological interaction was applied also. The proposed method was applied to 7 types of appliances (hair drier, heater, VDT, etc.) and their equivalent magnetic dipole moment and harmonic components were estimated. As the results, the useful data for quantifying magnetic field distribution around electric appliances were obtained.

지표면 위에 한쪽 면이 도체로 된 손실 유전체 슬랩 속의 다이폴 전원에 의한 동일면상의 전계 (An electric field induced on the same plane by a point dipole soruce within a conductor-backed lossy dielectric slab above the earth)

  • 박동국;라정웅
    • 전자공학회논문지A
    • /
    • 제33A권12호
    • /
    • pp.9-15
    • /
    • 1996
  • An electric field induced by a point dipole soruce within a conductor-backed lossy dielectric slab above the earth is calculated by anumerical method. the calcualtion is peformed on the plane which is parallel to the conductor plane and containing the point dipole soruce. Computed S$_{21}$ values of two parallel planar dipole antennas and two collinear planar dipole antennas are compared against each other, as well as the electic field magnitudes in those arrangements.

  • PDF

Effect of dipole electric field on low-voltage pentacene thin film transistors

  • Kim, Kang-Dae;Song, Chung-Kun
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2007년도 7th International Meeting on Information Display 제7권2호
    • /
    • pp.1636-1638
    • /
    • 2007
  • We report on low-voltage pentacene TFTs with a Al2O3/OTS as a gate dielectric. Improving device characteristics, we performed chemical modification of self-grown Al2O3 surface with an octadecyltrichlorosilane(OTS) self-assembled monolayer(SAM). As the result of this combination, the mobility was improved from 0.3 to $0.45\;cm^2/Vs$. In addition, we examined that the SAM dipole electric field have an influence on gate leakage current, transfer and output characteristics.

  • PDF

Design of Low Field RF Coil for Open MRI System by Electric Dipole Radiation

  • 김경락;양형진;오창현
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2001년도 제6차 학술대회 초록집
    • /
    • pp.174-174
    • /
    • 2001
  • Purpose: Dimensions of body RF coil composed of 4 rectangular loops for low field open MRI hav been optimized. The design result shows the field inhomogeneity of B1 field below 1.5 dB in the 25 cm DSV can be achieved. Method: Our low field RF coil is composed of 4 rectangular strip loops that assumed to b located at both the bottom and top sides of permanent magnet. All the loops have identica dimensions and current amplitude. First, the inductance of a loop is calculated. Second, the current distribution on the coil strip is calculated by using finite difference time doma method (FDTD). It takes as much as 4 days in FDTD simulation for low frequency RF field That's why the electrical dipole radiation method is used for simulation. With the curren distribution obtained using the FDTD simulation, for various dimensional parameters th magnetic field has been calculated by electric dipole radiation method, where the curren elements are regarded as electric dipole radiation sources. The field pattern from electri dipole radiation is almost same as that from FDTD simulation. Also, it is same as that fro the result using the Viot-Savart equation, for far tone radiation term becomes zero and th Bl field amplitude of near one radiation is the same as the B field due to static current The field homogeneity is calculated in the 25 cm BSV.

  • PDF

가전기기 발생 극저주파 자계 고조파 특성 해석 (Analysis on Harmonics Characteristics of ELF Magnetic Fields Generated by Electric Appliances)

  • 민석원;송기현;양광호;주문노
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제54권1호
    • /
    • pp.31-37
    • /
    • 2005
  • With biological effects by ELF(Extremely Low Frequency) magnetic field generated from power system, the transient magnetic field from electric appliances is a major issue presently. In this paper, we measured magnetic field distributions around electric appliances in view of harmonics and analyzed them by the use of an equivalent magnetic dipole moment method. This method was applied to 19 types of appliances, and their equivalent magnetic dipole moments and harmonic components were determined. The results show that this method is applicable to many appliances and the higher frequency magnetic field may induce higher current inside living bodies.

소형 이극안테나를 이용한 전계강도 프로브의 설계 및 제작 (Design and Fabrication of an Electric-Field Probe Using Short Dipole Antennas)

  • 김혁제;박동철;이애경;심환우
    • 한국전자파학회지:전자파기술
    • /
    • 제6권1호
    • /
    • pp.3-9
    • /
    • 1995
  • An isotropic electric-field probe, capable of characterizing and quantifying electromagnetic field, was fabricated. The probe consists of three short dipole antennas, a beam-lead Schottky diode and the high resistive transmission line. In order to get the isotropic response three mutually orthogonal dipoles are configured to form the probe. The probe's short dipole elements allow measurements of electric fields from 300MHz to 2GHz with a flatness of .+-. 2.9dB. The mutually orthogonal dipole configration shows a .+-. 1.2dB deviation in the isotropic response with respect to angle.

  • PDF

Design of Body RF Coil with Multiple Strips for Open MRI System by Pseudo Electric Dipole Radiation

  • 김경락;류승학;류연철;양형진;오창현
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2002년도 제7차 학술대회 초록집
    • /
    • pp.76-76
    • /
    • 2002
  • Purpose: The purpose of this study is to optimize the configuration of body RF coil composed of 4 planar subcoils for low field open MRI. Method: Our low field RE coil is composed of 4 subcoils assumed to be located at both the bottom and top sides of permanent magnet. Each subcoils has 3 main strips. The coil system has mirror inversion symmetry. First, the currents on the strips are obtained by inductance calculation and circuit analysis, Second, all the strips are divided into line strip elements across the strips, the self Inductances of line strip elements and the mutual inductances among the line strip elements are calculated, and current distributions of strip are obtained by circuit analysis, where each strip is considered as parallel combination of line strip elements. Finally all the line strip elements are segmented, magnetic field has been calculated by pseudo electric dipole radiation method, where the current elements are regarded as pseudo electric dipole radiation sources. We have performed above procedures for various configurations of RE coil. The field homogeneity is calculated in the 25 cm DSV.

  • PDF

다이폴 모델링 기법을 이용한 수중 전기장 신호 특성 예측 기법 연구 (A Study on Prediction Technique for Underwater Electric Field Signature Characteristic using Dipole Modelling Method)

  • 양창섭;정현주;이종주;전재진
    • 한국자기학회지
    • /
    • 제18권6호
    • /
    • pp.221-224
    • /
    • 2008
  • 본 논문에서는 함정 선체의 갈바닉 부식 전류에 의해 발생되는 수중 전기장 신호를 경계요소 해석 도구인 FNREMUS 소프트웨어를 이용하여 예측하고, 예측된 신호로부터 함정 전기장 신호 특성을 특이치 분해(singular value decomposition) 방법을 이용하여 등가적으로 다이폴 모델링하는 방법에 대해 기술하고 있다. 제안된 다이폴 모델링 기법은 30 m 심도에서 예측된 경계요소 해석 결과와의 평균 차이 비교 방법을 통해 타당함이 확인되었다. 본 논문에서 제안된 모델링 기법을 이용하면 함정에서의 다양한 심도 변화에 따른 수중 정 전기장 신호 분포 특성 예측 및 분석이 가능하다.