• Title/Summary/Keyword: digital subtraction

Search Result 205, Processing Time 0.024 seconds

A study on the applications of the digital subtraction angiography imaging technique (디지탈 혈관 조영 장치의 영상기술 응용에 관한 연구)

  • 남문현;김성룡
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1987.10b
    • /
    • pp.684-689
    • /
    • 1987
  • Digital Subtraction Angiography(DSA) technique has been widely used to detect vascular diseases and hemodynamic parameters noninvasively. However, there are few quantitative studies on the factors in fluencing the resultant DSA image quality. In this paper, several important factors are suggested to improved the DSA image quality based on mathematical analysis. Experimental DSA images for different filters are shown and also discussed the difference between original and processed image quality.

  • PDF

A Real Time Digital Subtraction Angiography (실시간 디지털 혈관조영술에 관한 연구)

  • 민병구;이태수
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.22 no.3
    • /
    • pp.48-53
    • /
    • 1985
  • A real time digital subtraction angiographic system (RTDSA) was developed and utilized for diagnosis of the diseases related with the blood vessel conditions in 200 patients. In this paper, we present the system configurations and the real time processed images of the patients'abdominal, renal, femoral, and hepatic arteries.

  • PDF

Moving Object Surveillance System based on Image Subtraction Technique (영상 Subtraction을 이용한 이동 물체 감시 시스템)

  • 이승현;류충상
    • Journal of the Korean Society of Safety
    • /
    • v.12 no.3
    • /
    • pp.60-66
    • /
    • 1997
  • In this paper, a moving object surveillance system, which can extract moving object in real-time, using image subtraction method is described. This technique based on the novelty filter having the structure of neural network associative memory. Digital arithmetic and timing control parts were composed of hardwired controller to treat two-dimensional massive image information. SRAMS having 20 ns access time were used for the image buffer that has high speed write/read property. Image extraction algorithm is discussed and supported by simulation and experiments.

  • PDF

NONLINEAR CONTRAST ENHANCEMENT ON SUBTRACTION IMAGES (계수공정영상의 비선형 대조도 증강효과에 관한 연구)

  • Lee Keon-Il;Jin Yeun-Hwa
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.27 no.2
    • /
    • pp.83-90
    • /
    • 1997
  • This study was performed to demonstrate the effect of linear or nonlinear contrast enhancement on subtraction images. Three different textures were radiograped on dental film. The first radiograph was taken without the presence of an object. the second, which showed trabucular bone, was taken of the molar area of a human. the third radiograph was taken of the coronal part of molars. Each film was digitized into a 1312 x 1024 pixel x 8 bit depth matrix by means of a Nikon 35 mm film scanner(LS-3510AF, Japan) with fixed gain and internal dark current correction to maintain constant illumination. The scanner was interfaced to a Macintosh Le ill computer(Apple Computer, Charlotte, N.C) This resulted in three pairs of images, including different textures-plain, bone and enamel. Digital regular, linearly and nonlinearly enhanced subtraction was performed. Computer software was ,used to simulate lesions in the shape of a 2D-Gaussian curve on each of a pair of images. The each subtraction images were presented in a random sequence to two groups of 10 observers(students and dentists). ROC analysis was used to compare observer performance. The following results were obtained ; 1. All of LCE subtraction, equalized subtraction and regular subtraction images of plain texture were diagnosed the best by far. 2. The data revealed a siginificant LCE effect in both the student group and the expert group. 3. Clinical expertise was a helphul factor for the observers in this study.

  • PDF

Three-Dimensional Digital Subtraction Angiographic Evaluation of Aneurysm Remnants after Clip Placement

  • Ahn, Soon-Seob;Kim, Young-Don
    • Journal of Korean Neurosurgical Society
    • /
    • v.47 no.3
    • /
    • pp.185-190
    • /
    • 2010
  • Objective : The aneurysm remnants rate was evaluated via three-dimensional digital subtraction angiography (3D-DSA) in the postoperative evaluation of clipped aneurysms. Methods : Data on surgically clipped aneurysms of anterior circulation obtained via postoperative 3D-DSA from February 2007 to March 2009 were gathered. The results of the postoperative 3D-DSA and of two-dimensional digital subtraction angiography (2D-DSA) for the detection of aneurysm remnants were compared, and an investigation was performed as to why 2D-DSA had missed some aneurysm remnants that were detected in the 3D-DSA. Various surgical factors that revealed aneurysm remnants in the 3D-DSA were also evaluated. Results : A total of 39 neck remnants of 202 clipped aneurysms (19.3%) were confirmed in 3D-DSA, and these were classified according to Sindou's classification of aneurysm remnants. Patients with only a neck remnant found in the 3D-DSA represented 17.3% (35/202 aneurysms) of the whole series, and those with a residuum of neck plus sac found in the 3D-DSA represented 1.9% (4/202 aneurysms). The causes of aneurysm remnants were no full visualization (14/39, 35.9%), parent and perforator artery protection (10/39, 25.6%), clip design problems (8/39, 20.5%), and broadnecked aneurysm (7/39, 17.9%). Conclusion : Patients with ${\leq}2$mm aneurysm remnants showed an increased risk of undetectable aneurysm remnants in the 2D-DSA. The most frequent location of the missed aneurysm in 2D-DSA was the anterior communicating artery. 3D-DSA showed more aneurysm remnants than what is indicated in the existing literature, the 2D-DSA.

The Value of Three-Dimensional Reconstructions of MRI Imaging using Maximum Intensity Projection Technique (유방 MRI의 최대강도투사 기법에 의한 3차원 재구성 영상의 유용성)

  • Cho, Jae-Hwan;Lee, Hae-Kag;Hong, In-Sik;Kim, Hyun-Joo;Jang, Hyun-Cheol;Park, Cheol-Soo;Park, Tae-Nam
    • Journal of Digital Contents Society
    • /
    • v.12 no.2
    • /
    • pp.157-164
    • /
    • 2011
  • The purpose of this study was to examine the usefulness of 3D reconstruction images in breast MRI by performing a quantitative comparative analysis in patients diagnosed with DCIS. On a 3.0T MR scanner, subtraction images and 3D reconstruction images were obtained from 20 patients histologically diagnosed with ductal carcinoma in situ (DCIS). The findings from the quantitative image analysis are the following: The 3D reconstruction images showed higher SNR at the lesion area, ductal area, and fat area that of the subtraction image. In addition, the CNR were not significantly different in the lesion area itself between the subtraction images and 3D reconstruction images.

Evaluation of mechanical and projective standardization in digital subtraction radiography (디지털 공제 방사선 촬영술에 있어서 기계적 및 투사적 규격화의 평가)

  • Choi Bong-In;Cho Bong-Hae;Nah Kyung-Soo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.28 no.1
    • /
    • pp.215-224
    • /
    • 1998
  • The following conclusions were obtained from the non-reconstructed and reconstructed subtraction images of the standard intraoral radiographs which were taken with paralleling technique with Rinn XCP only and with occlusal bite registration for geometric standardization using bilateral mandibular premolar and molar regions of two dry human skulls. 1. The SD of the overall subtraction images of the premolars and molars of the non-reconstructed, that is, the manual superimposition showed statistically significant difference between the non-registered and registered groups. 2. In non-reconstructed and non-registered cases, the quality of the subtraction images were improved when superimposition was focally done and this was more evident in areas where the radiographic images tend to be distorted due to anatomic reasons. 3. In non-reconstructed and registered cases, the subtraction images were consistent regardless of the anatomic site or the focus of superimposition. This means that the geometric standardization with only occlusal bite registration could produce serial radiographs which is suitable for subtraction. 4. The SD of the overall subtraction images of the premolars and molars of the reconstructed, that is, the automatic superimposition showed statistically insignificant difference between the non-registered and registered groups. This means that using reconstruction, subtraction radiography is possible without occlusal bite registration. 5. In reconstructed and non-registered cases, compatible quality of the subtraction images were obtained regardless of the anatomic site or area of the corresponding points. 6. In reconstructed and registered cases, best subtraction images whose quality showed sensitivity to the areas of corresponding points were obtained.

  • PDF

A comparative study on the accuracy of digital subtraction radiography according to the aquisition methods of reconstructed images (재구성영상 형성방법에 따른 디지털영상공제술의 정확성 비교연구)

  • Huh Young-June;Jeon In-Seong;Heo Min-Suk;Lee Sam-Sun;Choi Soon-Chul;Park Tae-Won;Kim Jong-Dae
    • Imaging Science in Dentistry
    • /
    • v.32 no.2
    • /
    • pp.107-111
    • /
    • 2002
  • Purpose : To compare the accuracy of digital subtraction images acquired by two different methods different in positioning four reference points for geometrical standardization. Materials and Methods : A total of 36 digital radiographic images of 6 volunteers were taken at the areas of the incisor, premolar, and molar of both the maxilla and mandible using the Digora system. Each image was moved 4 mm vertically and horizontally. Four oral and maxillofacial radiologists performed digital subtraction radiography between the paired images before and after movement using Emago (Oral Diagnostic Systems, Amsterdam, The Netherlands) and Sunny (Biomedisys Co., Seoul, Korea). The standard deviation of the internal gray value in Region of Interest (ROI) was statistically analyzed between the two programs using the paired t-test. Results : The standard deviation of pixel gray values from the digital subtraction images using the Sunny program were lower than that of the Emago program (p<0.05). All observers showed significant differences between each other when the Sunny program was used (p<0.05), but one observer showed a significantly higher score than other observers when they used Emago (p<0.05). The standard deviations of premolar area from both Sunny and Emago programs were significantly higher than those of anterior and molar regions (p<0.05). Conclusion: The subtracted images using the Sunny program were more accurate and sensitive than those taken using the Emago program.

  • PDF

Applications of digital subtraction angiography in the management of penetrating injuries of the maxillofacial region: A case report

  • Fonseca, Vitor Jose;Chaves, Roberta Rayra Martins;Campos, Felipe Eduardo Baires;Lehman, Luiz Felipe;Moraes, Gustavo Meyer;Castro, Wagner Henriques
    • Imaging Science in Dentistry
    • /
    • v.48 no.4
    • /
    • pp.295-300
    • /
    • 2018
  • This report presents a clinical case of trauma due to assault with a knife, and describes the importance of using the correct imaging modality in cases of facial penetrating trauma involving the superficial and deep anatomical planes. Penetrating wounds in the maxillofacial region are rare and poorly reported, but can result in serious complications that are difficult to resolve and may compromise the patient's quality of life, especially when large blood vessels or other vital structures are involved. Thus, it is essential to determine the extent of the affected blood vessels and the proximity of the retained object to the anatomical structures. In this case, digital subtraction angiography was the imaging modality chosen. The use of appropriate imaging examinations allows a proper map of the surgical field, reducing the chances of vascular damage during the surgical procedure.