• 제목/요약/키워드: digital scan

검색결과 371건 처리시간 0.031초

인터레이스 스캔 방식 디지털 카메라 떨림 블러에 대한 효과적 제거 알고리즘 (Effective De-blurring Algorithm for the Vibration Blur of the Interlaced Scan Type Digital Camera)

  • 전재춘;김형석
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제54권9호
    • /
    • pp.559-566
    • /
    • 2005
  • An effective do-blurring algorithm is proposed to remove the blur of the even and the odd line images of the interlaced scan type camera. n the object or the camera moves fast while the interlaced scan type digital camera is acquiring images, blur is often created due to the misalignment between two images of even and odd lines. In this paper, the blurred original image is separated into the even and the odd line images of the half size. Two full sized images are generated using interpolation technique based on these two in ages. Again, these images are signed and combined through the processes of feature extraction, matching, sub-pixel matching, outlier removal, and mosaicking. De-blurring simulations about the images of different camera motions have been done.

2D 포토 스캔 기술을 활용한 효율적인 3D 모델링 제작방법 연구 (A Study of Utilizing 2D Photo Scan Technology to Efficiently Design 3D Models)

  • 곽대위;정진헌
    • 디지털융복합연구
    • /
    • 제15권7호
    • /
    • pp.393-400
    • /
    • 2017
  • 일반적으로 특수영상 및 3D 애니메이션 제작에서 캐릭터와 배경을 3D 모델링을 할 때 MAYA나 3DS MAX 등의 3D 프로그램을 사용하여 제작한다. 그러나 이러한 제작방식은 작업 시간이 많이 소요될 뿐만 아니라 고비용이 발생한다. 본 연구에서는 2D 포토스캔 제작기술을 활용한 3D 모델링 제작방법의 우수성과 효율성을 증명하기 위하여 두 가지 실험을 하였다. 첫 번째, 동일한 오브젝트를 다양한 방법으로 모델링을 하였다. 두 번째, 동일한 백그라운드를 각기 다른 방법을 이용하여 모델링을 하였다. 이 두 가지 실험을 통하여 효과적인 2D 포토스캔 제작방법으로 모델링 시 유의해야할 사항과 제작기술 등을 제시하였다. 또한 실험에 따른 결과물을 바탕으로 2D 포토스캔 모델링 제작방법의 효율성과 우수성을 증명하였다.

3차원 디지털 영상과 CAD/CAM 시스템을 활용한 전악 임플란트 수복 증례 (Full mouth rehabilitation with dental implant utilizing 3D digital image and CAD/CAM system: case report)

  • 강세하;정승미;신재옥;방정환;김대환;최병호
    • 구강회복응용과학지
    • /
    • 제31권2호
    • /
    • pp.158-168
    • /
    • 2015
  • 본 증례는 상 하악 완전 무치악 환자에서 진단, 식립 그리고 보철물 제작에 디지털 방식을 활용하는 방법에 대해 제시하였다. 상악은 구개 부위, 하악은 기존 의치에 방사선 불투과성 마커를 부착한 후 구강스캔 및 CBCT 촬영을 시행하였다. 구강스캔 이미지와 CBCT 이미지를 중첩시켜 진단 및 수술가이드와 임시보철물을 제작하였다. 골유착 후에는 스캔바디를 이용한 구강스캔을 통해 최종보철물을 제작하였다. 임플란트를 이용한 전악수복에서 디지털 방식을 다양하게 활용하였으며 정확성과 환자의 불편감 최소화라는 목적에 만족할만한 결과를 얻었기에 이 증례를 보고하고자 한다.

Validity of Three-dimensional Facial Scan Taken with Facial Scanner and Digital Photo Wrapping on the Cone-beam Computed Tomography: Comparison of Soft Tissue Parameters

  • Aljawad, Hussein;Lee, Kyungmin Clara
    • Journal of Korean Dental Science
    • /
    • 제15권1호
    • /
    • pp.19-30
    • /
    • 2022
  • Purpose: The purpose of the study was to assess the validity of three-dimensional (3D) facial scan taken with facial scanner and digital photo wrapping on the cone-beam computed tomography (CBCT). Materials and Methods: Twenty-five patients had their CBCT scan, two-dimensional (2D) standardized frontal photographs and 3D facial scan obtained on the same day. The facial scans were taken with a facial scanner in an upright position. The 2D standardized frontal photographs were taken at a fixed distance from patients using a camera fixed to a cephalometric apparatus. The 2D integrated facial models were created using digital photo wrapping of frontal photographs on the corresponding CBCT images. The 3D integrated facial models were created using the integration process of 3D facial scans on the CBCT images. On the integrated facial models, sixteen soft tissue landmarks were identified, and the vertical, horizontal, oblique and angular distances between soft tissue landmarks were compared among the 2D facial models and 3D facial models, and CBCT images. Result: The results showed no significant differences of linear and angular measurements among CBCT images, 2D and 3D facial models except for Se-Sn vertical linear measurement which showed significant difference for the 3D facial models. The Bland-Altman plots showed that all measurements were within the limit of agreement. For 3D facial model, all Bland-Altman plots showed that systematic bias was less than 2.0 mm and 2.0° except for Se-Sn linear vertical measurement. For 2D facial model, the Bland-Altman plots of 6 out of 11 of the angular measurements showed systematic bias of more than 2.0°. Conclusion: The facial scan taken with facial scanner showed a clinically acceptable performance. The digital 2D photo wrapping has limitations in clinical use compared to 3D facial scans.

토공현장 스캔데이터 밀도 균일화를 위한 정합 후처리 기술 개발 (Development of Registration Post-Processing Technology to Homogenize the Density of the Scan Data of Earthwork Sites)

  • 김용건;박수열;김석
    • 대한토목학회논문집
    • /
    • 제42권5호
    • /
    • pp.689-699
    • /
    • 2022
  • 최근 다양한 산업에서 첨단기술의 적용으로 높은 생산성 향상을 이루고 있지만 건설산업의 경우 생산성 향상이 비교적 낮게 조사되어, 이를 극복하기 위한 첨단기술 연구가 빠르게 진행되고 있다. 여러 첨단기술 중 3차원 스캔 기술은 실제 대상물을 손쉽게 디지털화 할 수 있다는 점에서 건설현장의 3차원 디지털 지형 모델 생성을 위한 기술로 널리 활용되고 있다. 특히 3차원 디지털 지형 모델은 토공 중장비의 자동제어 및 가이던스 등과 같은 건설 자동화의 기초자료가 될 수 있어 지형 스캔데이터의 높은 품질이 요구되고 있다. 3차원 디지털 지형 모델의 품질은 3D 스캐너의 성능 및 취득환경뿐 아니라 지형 스캔데이터 취득 후 3차원 디지털 지형 모델 생성을 위한 전처리 과정인 노이즈제거, 정합 및 병합과정 등 또한 많은 영향을 끼치고 있어, 지형 스캔데이터 처리의 성능 증진이 필요할 것으로 보인다. 본 연구에서는 3차원 디지털 지형 모델 생성을 위한 전처리 과정 중 정합과정에서 발생하는 지형 스캔데이터의 밀도 불균일 문제를 해결하고자 한다. 이를 위해 본 연구에서 개발한 정합 후처리 기술인 '픽셀기반 점군비교 알고리즘'을 제시하였으며, 실제 토공현장에서 취득한 지형 스캔데이터를 활용해 개발한 알고리즘의 성능검증을 수행하여 지형 스캔데이터 정합 후 불균일 문제의 개선 가능성을 검증하고 밀도 별 지형 스캔데이터에 대한 알고리즘의 최적 파라미터를 제시하였다.

다중 디지털 사진을 이용한 3차원 이미지 모델 생성 (Generation of 3 Dimensional Image Model from Multiple Digital Photographs)

  • 정태은;석정민;신효철;류재평
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.1634-1637
    • /
    • 2003
  • Any given object on the motor-driven turntable is pictured from 8 to 72 different views with a digital camera. 3D shape reconstruction is performed with the integrated software called by Scanware from these multiple digital photographs. There are several steps such as configuration, calibration, capturing, segmentation, shape creation, texturing and merging process during the shape reconstruction process. 3D geometry data can be exported to cad data such as Autocad input file. Also 3D image model is generated from 3D geometry and texture data, and is used to advertise the model in the internet environment. Consumers can see the object realistically from wanted views by rotating or zooming in the internet browsers with Scanbull spx plug-in. The spx format allows a compact saving of 3D objects to handle or download. There are many types of scan equipments such as laser scanners and photogrammetric scanners. Line or point scan methods by laser can generate precise 3D geometry but cannot obtain color textures in general. Reversely, 3D image modeling with photogrammetry can generate not only geometries but also textures from associated polygons. We got various 3D image models and introduced the process of getting 3D image model of an internet-connected watchdog robot.

  • PDF

Characteristic of High Voltage Aging in AC PDPs

  • Lee, Yong-Han;Kim, Oe-Dong;Ahn, Byoung-Nam;Choi, Kwang-Yeol;Kim, Sung-Tae
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2006년도 6th International Meeting on Information Display
    • /
    • pp.932-934
    • /
    • 2006
  • A relationship between discharge delay time and the aging method were investigated: A-Y (Address electrode - Scan electrode) aging and conventional X-Y(Common electrode - Scan electrode) aging with the variation of sustain voltage beyond self-erasing discharge. Although A-Y aging decreases discharge delay time, it has several drawbacks like non-uniformity of discharge, degradation of luminous efficiency and a color temperature. In a conventional aging condition which is carried out near the mid-margin voltage, discharge delay time is short in low voltage and high frequency condition. As an alternative to conventional voltage aging, high voltage aging is suggested which is carried out at self-erasing sustain voltage region. High voltage aging shows lower discharge delay time and fast aging speed than conventional voltage aging.

  • PDF

흉부CT 검사 시 HRCT 영상 재구성의 유용성 (Usefulness Evaluation of HRCT using Reconstruction in Chest CT)

  • 박성민;김긍식;강성민;유병규;이기배
    • 대한디지털의료영상학회논문지
    • /
    • 제17권1호
    • /
    • pp.13-18
    • /
    • 2015
  • Purpose : Skip the repetitive HRCT axial scan in order to reduce the exposure of patients during chest HRCT scan, Helical Scan Data into a reconstructed image, and exposure of the patient change and visually evaluate the usefulness of the HRCT images. Materials and method : Patients were enrolled in the survey are 50 people who underwent chest CT scans of patients who presented to the hospital from January 2015 to March 2015. 50 people surveyed 22 people men and 28 people women people showed an average distribution of 30 to 80 years age was 48 years. 50 patients to Somatom Sensation 64 ch (Siemens) model with 120 kVp tube voltage to a reference mAs tube current to mAs (Care dose, Siemens) as a whole, including the lungs and the chest CT scan was performed. Scan upon each patient CARE dose 4D (Automatic exposure control, Siemens Medical Solution Erlangen, Germany) was to maintain the proper radiation dose scan every cross-section through a device that automatically adjusts the tube current of. CT scan is the rotation time of the Tube slice collimation, slice width 0.6 mm, pitch factor was made under the terms of 1.4. CT scan obtained after the raw data (raw data) to the upper surface of the axial images and coronal images for each slice thickness 1 mm, 5 mm intervals in the high spatial frequency calculation method (hight spatial resolution algorithm, B60 sharp) was the use of the lung window center -500 HU, windows were reconstructed into images in the interval -1000 HU to see. Result : 1. Measure the total value of DLP 50 patients who proceed to chest CT group A (Helical Scan after scan performed with HRCT) and group B (Helical Scan after the HR image reconstruction to the original data) compared with the group divided, analysis As a result of the age, but show little difference for each age group it had a decreased average dose of about 9%. 2. A Radiation read the results of the two Radiologist and a doctor upper lobe and middle lobe of the lung takes effect the visual evaluation is not a big difference between the two images both, depending on the age of the patient, especially if the blood vessels of the lower lobe (A: 3.4, B: 4.6) and bronchi(A: 3.8, B4.7) image shake caused by breathing in anxiety (blurring lead) to the original data (raw data) showed that the reconstructed image is been more useful in diagnostic terms. Conclusion : Scan was confirmed a continuous, rapid motion video to get Helical scan is much lower lobe lung reduction in visual blurring, Helical scan data to not repeat the examination by obtaining HRCT images reorganization reduced the exposure of the patient.

  • PDF

Intraoral scanning of the edentulous jaw without additional markers: An in vivo validation study on scanning precision and registration of an intraoral scan with a cone-beam computed tomography scan

  • Julie Tilly Deferm;Frank Baan;Johan Nijsink;Luc Verhamme;Thomas Maal;Gert Meijer
    • Imaging Science in Dentistry
    • /
    • 제53권1호
    • /
    • pp.21-26
    • /
    • 2023
  • Purpose: A fully digital approach to oral prosthodontic rehabilitation requires the possibility of combining (i.e., registering) digital documentation from different sources. This becomes more complex in an edentulous jaw, as fixed dental markers to perform reliable registration are lacking. This validation study aimed to evaluate the reproducibility of 1) intraoral scanning and 2) soft tissue-based registration of an intraoral scan with a cone-beam computed tomography (CBCT) scan for a fully edentulous upper jaw. Materials and Methods: Two observers independently performed intraoral scans of the upper jaw in 14 fully edentulous patients. The palatal vault of both surface models was aligned, and the inter-observer variability was assessed by calculating the mean inter-surface distance at the level of the alveolar crest. Additionally, a CBCT scan of all patients was obtained and a soft tissue surface model was generated using patient-specific gray values. This CBCT soft tissue model was registered with the intraoral scans of both observers, and the intraclass correlation coefficient(ICC) was calculated to evaluate the reproducibility of the registration method. Results: The mean inter-observer deviation when performing an intraoral scan of the fully edentulous upper jaw was 0.10±0.09 mm. The inter-observer agreement for the soft tissue-based registration method was excellent(ICC=0.94; 95% confidence interval, 0.81-0.98). Conclusion: Even when teeth are lacking, intraoral scanning of the jaw and soft tissue-based registration of an intraoral scan with a CBCT scan can be performed with a high degree of precision.

Efficient Path Delay Testing Using Scan Justification

  • Huh, Kyung-Hoi;Kang, Yong-Seok;Kang, Sung-Ho
    • ETRI Journal
    • /
    • 제25권3호
    • /
    • pp.187-194
    • /
    • 2003
  • Delay testing has become an area of focus in the field of digital circuits as the speed and density of circuits have greatly improved. This paper proposes a new scan flip-flop and test algorithm to overcome some of the problems in delay testing. In the proposed test algorithm, the second test pattern is generated by scan justification, and the first test pattern is processed by functional justification. In the conventional functional justification, it is hard to generate the proper second test pattern because it uses a combinational circuit for the pattern. The proposed scan justification has the advantage of easily generating the second test pattern by direct justification from the scan. To implement our scheme, we devised a new scan in which the slave latch is bypassed by an additional latch to allow the slave to hold its state while a new pattern is scanned in. Experimental results on ISCAS'89 benchmark circuits show that the number of testable paths can be increased by about 45 % over the conventional functional justification.

  • PDF