• Title/Summary/Keyword: digital protection relay

Search Result 86, Processing Time 0.024 seconds

A basic study on protective relay testing using RTDS in power system applying SFCL (초전도한류기 적용계통에서의 RTDS 보호계전기 연계시험을 위한 기본연구)

  • Lee, Seung-Ryul;Yoon, Jae-Young;Kim, Jae-Ho;Lee, Byong-Jun
    • Progress in Superconductivity and Cryogenics
    • /
    • v.11 no.3
    • /
    • pp.35-39
    • /
    • 2009
  • The study for a protective relay system is one of the important technical issues on the power system application of Superconducting Fault Current Limiter (SFCL). We used Real Time Digital Simulator(RTDS) to study the true interaction of the protection system with the power system. RTDS modeling of SFCL is necessary to the detailed protective relay tests. In this paper, we developed an analysis model using RTDS for studying the transient behavior of 22.9kV SFCL and carried out closed-loop testing of protective relays in distribution power system with the developed SFCL model. The SFCL model has the operation mechanism of 22.9kV hybrid SFCL being developed by LSIS and KEPRI in Korea. The parameters of the model are based on the test data of the real SFCL. Power system planners and operators can solve the expected problems in power system application of SFCL using protective relay testing results.

A Study on the Development and Application of Digital Protective Relay for DC Feeding System of Light Rail Transit System (경전철 직류급전계통을 위한 디지털 보호제어장치의 개발 및 적용에 관한 연구)

  • Baek, Byung-San;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.2
    • /
    • pp.77-86
    • /
    • 2005
  • The DC protection and control device for the feeding system of a Light Rail Transit(LRT) system is developed. For the development, the short circuit characteristics in the system are analyzed. As a result a protection algorithm for the DC fault selective relay (50F) is newly proposed, and principles of the DC fault selective relay, Line Test Device (LTD), DC Over Current Relay (DC OCR) are introduced From the development, the specifications and codes used to be unclear have become clarified and summarized. Moreover, the methods to examine the protective characteristics and Electromagnetic Compatibility (EMC) are established Finally, the performance and the effectiveness of the developed protective relay have been verified with the test based on IEC. For the reliability of the system, the relay has been installed and is being operated at the test track of the LRT system at Gyeong-San.

The Design of UFR with Fast Frequency Measurement Technique (고속의 주파수 계측 알고리즘을 갖는 저주파 계전기 설계)

  • Park, Jong-Chan;Kim, Byung-Jin
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.55 no.1
    • /
    • pp.1-5
    • /
    • 2006
  • In this paper, the frequency estimator and DFT filter gain compensation for UFR(Under Frequency protection Relay) is introduced. Due to the sudden appearance of generator loads or faults in power system, the frequency is supposed to deviate from its nominal value. Because a frequency calculation is based on phase information, it needs sufficient sampling data to figure out a precious frequency. Therefore the frequency measurement for UFR needs excellent qualities such as high speed and precision with low sampling frequency Authors propose the frequency estimator which compares the vector differences and the DFT filter gain compensation which identifies DFT filter error and correct it. Using the frequency estimator and compensation, UFR which has the 0.01[ms] calculation delay and 0.003[Hz] measurement error is implemented with digital processor.

The Design of Digital Protection Relay under Harmonic Distortion (고조파 왜곡을 고려한 디지털 보호계전기의 설계)

  • Kim, Beung-Jin;Cho, Chul-Hee;Lee, Bo-In;Kim, Jung-Han
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.566-567
    • /
    • 2002
  • In this study, the measurement part in which the Fast Fourier Transform module and orthogonal filter are included is proposed. Protection relay should has a high precision and concurrently real-time response. Because FFT routine give micro-processor heavy burden and orthogonal filter reduces precision, both FFT module and orthogonal filter are designed to have different sampling frequency.

  • PDF

A Design of Power Management and Control System using Digital Protective Relay for Motor Protection, Fault Diagnosis and Control (모터 보호, 고장진단 및 제어를 위한 디지털 보호계전기 활용 전력감시제어 시스템 설계)

  • Lee, Sung-Hwan;Ahn, Ihn-Seok
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.10
    • /
    • pp.516-523
    • /
    • 2000
  • In this paper, intelligent methods using digital protective relay in power supervisory control system is developed in order to protect power systems by means of timely fault detection and diagnosis during operation for induction motor which has various load environments and capacities in power systems. The spectrum pattern of input currents was used to monitor to state of induction motors, and by clustering the spectrum pattern of input currents, the newly occurrence of spectrums pattern caused by faults were detected. For diagnosis of the fault detected, the fuzzy fault tree was derived, and the fuzzy relation equation representing the relation between an induction motor fault and each fault type, was solved. The solution of the fuzzy relation equation shows the possibility of each fault's occurring. The results obtained are summarized as follows: 1) The test result on the basis of KEMC1120 and IEC60255, show that the operation time error of the digital motor protective relay is improved within ${\pm}5%$. 2) Using clustering algorithm by unsupervisory learning, an on-line fault detection method, not affected by the characteristics of loads and rates, was implemented, and the degree of dependency by experts during fault detection was reduced. 3) With the fuzzy fault tree, fault diagnosis process became systematic and expandable to the whole system, and the diagnosis for sub-systems can be made as an object-oriented module.

  • PDF

The Design of Frequency Variation Compensator for Digital Protection Relay (디지털 보호 계전기를 위한 주파수 변동 보상기의 설계)

  • Kim, Beung-Jin;Lee, Bo-In;Kim, Jung-Han
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.563-565
    • /
    • 2002
  • The designed frequency compensator is proposed to make the estimation of amplitude of fundamental frequency immune to frequency variation. The designed method which has a simple structure and low calculation burden is proper to apply digital protective relay. The results of experimental demonstrate that the frequency compensator has good performance to the estimation of amplitude of fundamental frequency against frequency variation.

  • PDF

A Digital Current Differential Transformer Protecion Algorithm Minimizing the Effect of DC-offset (DC-offset 영향을 최소화한 변압기보호 디지털 비율차동 계전알고리즘 구현)

  • Kwon, Young-Jin;Kang, Sang-Hee;Lee, Seeng-Jae;Jung, Sung-Kyo
    • Proceedings of the KIEE Conference
    • /
    • 2001.05a
    • /
    • pp.38-41
    • /
    • 2001
  • This paper presents a digital current differential protection algorithm for a transformer in power system. This algorithm uses an FIR filter to improve the performance of the relay. This paper presents a practical method setting the operating slope of the relay and reduce ct mismatch. A series of EMTP simulation results have shown effectiveness of the algorithm under various type of transformers and conditions.

  • PDF

A PC based, Low Cost, Tester for Digital Protective Relay (PC 인터페이스에 의한 디지털 보호 계전기의 성능 시험기)

  • Park, Chul-Won;Seo, Jong-Wan;Jung, Ho-Sung;Shin, Myong-Chul;Lee, Bock-Ku
    • Proceedings of the KIEE Conference
    • /
    • 1999.11b
    • /
    • pp.306-308
    • /
    • 1999
  • Recently, several developments of real-time simulators have been reported. But they are very high cost. And then they are difficult to apply for relay testing in small business. This paper presents the structure and performance of a new pc based, low cost, tester to digital protection relays. Fault transients are generated either by simulating signals using EMTP or by recorded fault signals.

  • PDF

Digital Negative Sequence Relay Algorithm for Detection of Unbalanced State in a Generator (발전기의 불평형 검출을 위한 디지털 역상 계전 알고리즘)

  • Park, Chul-Won
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.62 no.4
    • /
    • pp.198-203
    • /
    • 2013
  • There are conditions that can be unbalanced three phase currents in a large generator by untransposed lines, unbalanced loads, unsymmetrical faults, and open phases. The unbalanced conditions can producing negative sequence components of current that induce two times frequence current in the surface of the rotor, the retaining rings, the slot wedges in the field windings. These rotor currents make the rotor rapidly overheat, so the rotor can cause substantial damage in a very short time. This paper presents the digital negative sequence relay algorithm for unbalanced protection in a generator. The proposed algorithm was tested by using collected current signals on PSCAD/EMTDC considering a hydro turbine based generator control system. It can be seen that the proposed relaying by negative sequence current is useful for detection of unbalanced state of large generator.

Digital Distance Relay with Adaptive Protection Zone (Adaptive보호범위를 가진 송전선로 보호용 디지털 거리계전기)

  • Jung, Chang-Ho;Lee, Jae-Gyu;Jung, Byung-Tae;Ahn, Bok-Shin
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.893-895
    • /
    • 1998
  • This paper presents the adaptive setting method of distance relay under the single line ground fault. The apparent impedance measured at the relaying point and actual impedance is different because of fault resistance and various prefault loading condition. For a resistance earth fault detection, relay setting zone is adaptively changed with measured load current and bus voltage at the relaying point to avoid maloperation.

  • PDF