• 제목/요약/키워드: digital orthodontics

검색결과 122건 처리시간 0.025초

Evaluation of the alignment efficiency of nickel-titanium and copper-nickel-titanium archwires in patients undergoing orthodontic treatment over a 12-week period: A single-center, randomized controlled clinical trial

  • Aydin, Burcu;Senisik, Neslihan Ebru;Koskan, Ozgur
    • 대한치과교정학회지
    • /
    • 제48권3호
    • /
    • pp.153-162
    • /
    • 2018
  • Objective: The aim of this trial was to compare the alignment efficiency and intermaxillary arch dimension changes of nickel-titanium (NiTi) or copper-nickel-titanium (CuNiTi) round archwires with increasing diameters applied sequentially to the mandibular arch. Methods: The initial alignment phase of fixed orthodontic treatment with NiTi or CuNiTi round archwires was studied in a randomly allocated sample of 66 patients. The NiTi group comprised 26 women, 10 men, and the CuNiTi ($27^{\circ}C$) group comprised 20 women, 10 men. The eligibility criteria were as follows: anterior mandibular crowding of minimum 6 mm according to Little's Irregularity Index (LII), treatment requiring no extraction of premolars, 12 to 18 years of age, permanent dentition, skeletal and dental Class I malocclusion. The main outcome measure was the alignment of the mandibular anterior dentition; the secondary outcome measure was the change in mandibular dental arch dimensions during 12 weeks. Simple randomization (allocation ratio 1:1) was used in this single-blind study. LII and mandibular arch dimensions were measured on three-dimensional digital dental models at 2-week intervals. Results: No statistically significant difference was observed between NiTi and CuNiTi according to LII (p > 0.05). Intercanine and intermolar arch perimeters increased in the CuNiTi group (p < 0.001). Inter-first premolar width showed a statistically significant interaction in week ${\times}$ diameter ${\times}$ application (p < 0.05). Conclusions: The effects of NiTi and CuNiTi round archwires were similar in terms of their alignment efficiency. However, the intercanine and intermolar arch perimeters, and the inter-first premolar width changes differed between groups.

Debonding forces of three different customized bases of a lingual bracket system

  • Sung, Jang-Won;Kwon, Tae-Yub;Kyung, Hee-Moon
    • 대한치과교정학회지
    • /
    • 제43권5호
    • /
    • pp.235-241
    • /
    • 2013
  • Objective: The purpose of this study was to investigate whether extension of the custom base is necessary for enhancement of bond strength, by comparing the debonding forces and residual adhesives of 3 different lingual bracket systems. Methods: A total of 42 extracted upper premolars were randomly divided into 3 groups of 14 each for bonding with brackets having (1) a conventional limited resin custom base; (2) an extended gold alloy custom base: Incognito${TM}$; and (3) an extended resin custom base: KommonBase${TM}$. The bonding area was measured by scanning the bracket bases with a 3-dimensional digital scanner. The debonding force was measured with an Instron universal testing machine, which applied an occlusogingival shear force. Results: The mean debonding forces were 60.83 N (standard deviation [SD] 10.12), 69.29 N (SD 9.59), and 104.35 N (SD17.84) for the limited resin custom base, extended gold alloy custom base, and extended resin custom base, respectively. The debonding force observed with the extended resin custom base was significantly different from that observed with the other bases. In addition, the adhesive remnant index was significantly higher with the extended gold alloy custom base. Conclusions: All 3 custom-base lingual brackets can withstand occlusal and orthodontic forces. We conclude that effective bonding of lingual brackets can be obtained without extension of the custom base.

SOUND SPECTROGRAPH를 이용한 개교환자의 한국어 자${\cdot}$모음의 발성에 관한 연구 - 주파수 분석을 중심으로 - (A SOUND SPECTROGRAPHICAL STUDY ON THE KOREAN VOWELS AND CONSONANTS PRONOUNCED BY OPENBITE PATIENTS - Frequency Analysis -)

  • 김기달;양원식
    • 대한치과교정학회지
    • /
    • 제15권1호
    • /
    • pp.55-66
    • /
    • 1985
  • The study was undertaken to ascertain the speech defect of patients with malocclusion, especially of openbite patients, by means of the spectral analysis method. The experimental group was composed of ten female openbite patients and their mean age was 13.8 yrs. The control group was also composed of ten female girls and their mean age was 13.7 yrs. As for the speech material, eight Korean monophthrongs and two Korean fricatives and two affricatives were used. Speeches were recorded and then analyzed by a Kay 7800 digital sonagraph. Formant frequency level or range was used as a phonemic parameter. The results were as follows: 1. Among Vowels /a:/ : $F_1,\;F_3\;and\;F_1/F_2$ showed abnormality. /o:/ and $/w:/:F_2,\;F_2-F_1\;and\;F_1/F_2$ showed abnormality. 2. Among Consonants /S/ and /h/ : The upper and lower borders of the frequency range showed abnormality. (equation omitted) : The lower border of the frequency range showed abnormality. $/C^{h}/$ : The upper and lower borders of the frequency range and concentration point showed abnormality.

  • PDF

Accuracy of virtual 3-dimensional cephalometric images constructed with 2-dimensional cephalograms using the biplanar radiography principle

  • Lee, Jae-Seo;Kim, Sang-Rok;Hwang, Hyeon-Shik;Lee, Kyungmin Clara
    • Imaging Science in Dentistry
    • /
    • 제51권4호
    • /
    • pp.407-412
    • /
    • 2021
  • Purpose: The purpose of this study was to evaluate the accuracy of virtual 3-dimensional (3D) cephalograms constructed using the principle of biplanar radiography by comparing them with cone-beam computed tomography (CBCT) images. Materials and Methods: Thirty orthodontic patients were enrolled in this study. Frontal and lateral cephalograms were obtained with the use of a head posture aligner and reconstructed into 3D cephalograms using biplanar radiography software. Thirty-four measurements representing the height, width, depth, and oblique distance were computed in 3 dimensions, and compared with the measurements from the 3D images obtained by CBCT, using the paired t-test and Bland-Altman analysis. Results: Comparison of height, width, depth, and oblique measurements showed no statistically significant differences between the measurements obtained from 3D cephalograms and those from CBCT images (P>0.05). Bland-Altman plots also showed high agreement between the 3D cephalograms and CBCT images. Conclusion: Accurate 3D cephalograms can be constructed using the principle of biplanar radiography if frontal and lateral cephalograms can be obtained with a head posture aligner. Three-dimensional cephalograms generated using biplanar radiography can replace CBCT images taken for diagnostic purposes.

Validity of Three-dimensional Facial Scan Taken with Facial Scanner and Digital Photo Wrapping on the Cone-beam Computed Tomography: Comparison of Soft Tissue Parameters

  • Aljawad, Hussein;Lee, Kyungmin Clara
    • Journal of Korean Dental Science
    • /
    • 제15권1호
    • /
    • pp.19-30
    • /
    • 2022
  • Purpose: The purpose of the study was to assess the validity of three-dimensional (3D) facial scan taken with facial scanner and digital photo wrapping on the cone-beam computed tomography (CBCT). Materials and Methods: Twenty-five patients had their CBCT scan, two-dimensional (2D) standardized frontal photographs and 3D facial scan obtained on the same day. The facial scans were taken with a facial scanner in an upright position. The 2D standardized frontal photographs were taken at a fixed distance from patients using a camera fixed to a cephalometric apparatus. The 2D integrated facial models were created using digital photo wrapping of frontal photographs on the corresponding CBCT images. The 3D integrated facial models were created using the integration process of 3D facial scans on the CBCT images. On the integrated facial models, sixteen soft tissue landmarks were identified, and the vertical, horizontal, oblique and angular distances between soft tissue landmarks were compared among the 2D facial models and 3D facial models, and CBCT images. Result: The results showed no significant differences of linear and angular measurements among CBCT images, 2D and 3D facial models except for Se-Sn vertical linear measurement which showed significant difference for the 3D facial models. The Bland-Altman plots showed that all measurements were within the limit of agreement. For 3D facial model, all Bland-Altman plots showed that systematic bias was less than 2.0 mm and 2.0° except for Se-Sn linear vertical measurement. For 2D facial model, the Bland-Altman plots of 6 out of 11 of the angular measurements showed systematic bias of more than 2.0°. Conclusion: The facial scan taken with facial scanner showed a clinically acceptable performance. The digital 2D photo wrapping has limitations in clinical use compared to 3D facial scans.

측두 하악 관절 장애 환자의 파노라마 영상과 cone beam형 전산화 단층 영상의 비교 (Comparison of bony changes between panoramic radiograph and cone beam computed tomographic images in patients with temporomandibular joint disorders)

  • 이동렬;김연중;송윤헌;이남호;임용규;강승택;안석준
    • 대한치과교정학회지
    • /
    • 제40권6호
    • /
    • pp.364-372
    • /
    • 2010
  • 본 연구는 교정 진단 및 치료 계획에 어려움을 줄 수 있는 측두 하악 관절 장애 증상을 보이는 환자의 cone beam computed tomography (CBCT) 영상과 파노라마 영상을 비교하여 파노라마 영상의 유용성을 알아보고자 하였다. 2008년 6월부터 2008년 11월까지 측두 하악 관절 부위의 이상 증상으로 치과 의원에 내원한 환자를 대상으로 임상 진단과 파노라마 촬영을 시행 후 CBCT로 촬영한 106명, 212개 관절을 대상으로 영상의 결과를 비교하였다. 2명의 치과의사가 하악 과두의 골변화의 양상을 관찰하여 정상(normal), 편평화(flattening), 골경화(sclerosis), 골증식체(osteophyte), 침식(erosion)으로 나누었다. 그 결과로 첫째, 검사자간 신뢰도에서 파노라마(weighted kappa: 0.714), CBCT (weighted kappa: 0.727) 각각의 영상 진단 일치도가 높았다. 둘째, CBCT 영상에 대한 파노라마 영상의 A 검사자의 민감도는 82.4%, 특이도는 58.1%였으며 B 검사자는 각각 84.3%, 61.5%였다. 셋째, 파노라마 영상과 CBCT 영상이 5% 유의수준에서 두 영상 간 판독이 동일하지 않았다. 이상의 결과는 파노라마 영상이 CBCT 영상과 비교할 때 비교적 높은 80% 이상의 민감도를 보여 측두 하악 관절 골 변화의 일차적인 진단수단으로 임상적으로 유용하게 사용될 수 있다는 것과 측두 하악 관절의 골 변화가 파노라마 영상에서 불분명한 경우 CBCT를 사용하였을 때 더욱 정밀한 진단이 될 수 있다는 것을 보여주었다.

일반두부방사선계측사진과 디지털방사선계측사진의 계측점 식별의 오차 및 재현성에 관한 비교 연구 (The comparison of landmark identification errors and reproducibility between conventional lateral cephalometric radiography and digital lateral cephalometric radiography)

  • 이양구;양원식;장영일
    • 대한치과교정학회지
    • /
    • 제32권2호통권91호
    • /
    • pp.79-89
    • /
    • 2002
  • 본 연구의 목적은 일반두부방사선계측사진과 디지털두부방사선계측사진의 계측점 식별의 오차를 구하여 각각의 영상에서 오차의 특징을 살펴보고 재현성을 비교 평가하는 것이다. 연구 대상은 서울대학교병원 치과진료부 교정과에 내원한 교정 환자 중 18세에서 29세 사이의 성인 환자 중에서 일반두부방사선계측사진군과 디지털두부방사선계측사진군 각각 15명씩 30명을 무작위로 선택하여 연구 대상으로 하였으며 남녀의 구별이나 두개 안면 구조의 형태는 고려하지 않았다. 계측점은 동일인이 시간차를 두고 식별 하였다. 식별 후 각 계측점은 좌표 (x, y)로 표시하였으며, 처음 계측점을 식별한 두부방사선계측사진군을 T1으로, 1 주 후 동일 계측점을 재식별한 두부방사선계측사진군을 T2로, 1 달 후 동일계측점을 재식별한 두부방사선계측사진군을 T3로 분류하였다. 오차의 평균과 표준편차는 x좌표, y좌표로 구분하여 계산하였다. 초기 식별 1주 후 재식별시 오차는 T2-T1(x), T2-T1(y)로, 초기 측정 1달 후 재시별시 오차는 T3-T1(x), T3-T1(y)로 표시하였으며 일반두부방사선계측사진과 디지털두부방사선계측사진으로 각각 나누었다. 재현성의 평가를 위한 오차간의 통계학적인 검정은 independent t-test를 사용하였으며 다음과 같은 결론을 얻었다. 1. 디지털두부방사선계측사진이 일반두부방사선계측사진보다 일반적으로 오차의 평균 및 표준편차가 작았다. 2. 일반두부방사선계측사진의 오차와 디지털두부방사선계측사진의 오차가 통계학적으로 유의성 있는 차이를 보인 항목은 드물었다. 3.상의 향상을 통한 오차의 개선은 한계가 있었으며 상이 향상되더라도 각 계측점의 오차 의 경향은 크게 변하지 않았다.

Skin entrance dose for digital and film radiography in Korean dental schools

  • Cho Eun-Sang;Choi Kun-Ho;Kim Min-Gyu;Lim Hoi-Jeong;Yoon Suk-Ja;Kang Byung-Cheol
    • Imaging Science in Dentistry
    • /
    • 제35권4호
    • /
    • pp.203-205
    • /
    • 2005
  • Purpose: This study was aimed to compare skin entrance dose of digital radiography with that of film radiography and to show the dose reduction achievement with digital systems at 11 dental schools in Korea. Materials and Methods: Forty six intraoral radiographic systems in 11 dental schools were included in this study. Digital sensors were used in 33 systems and film was used in 13 systems. Researchers and the volunteer visited 11 dental schools in Korea. Researchers asked the radiologic technician (s) at each school to set the exposure parameters and aiming the x-ray tube for the periapical view of the mandibular molar of the volunteer. The skin entrance doses were measured at the same exposure parameters and distance by the technician for each system with a dosimeter (Multi-O-Meter : Unfors instruments, Billdal, Sweden). Results: The median dose was $491.2{\mu}Gy$ for digital radiography and $1,205.0{\mu}Gy$ for film radiography. The skin entrance dose in digital radiography was significantly lower than that of film radiography (p<0.05). Conclusion: Fifty-nine percent skin entrance dose reduction with digital periapical radiography was achieved over the film radiography in Korean dental schools.

  • PDF

Mandibular arch orthodontic treatment stability using passive self-ligating and conventional systems in adults: A randomized controlled trial

  • Rahman, Norma Ab;Wey, Mang Chek;Othman, Siti Adibah
    • 대한치과교정학회지
    • /
    • 제47권1호
    • /
    • pp.11-20
    • /
    • 2017
  • Objective: This randomized controlled trial aimed to compare the stability of mandibular arch orthodontic treatment outcomes between passive self-ligating and conventional systems during 6 months of retention. Methods: Forty-seven orthodontic patients with mild to moderate crowding malocclusions not requiring extraction were recruited based on inclusion criteria. Patients (mean age $21.58{\pm}2.94years$) were randomized into two groups to receive either passive self-ligating ($Damon^{(R)}$ 3MX, n = 23) or conventional system (Gemini MBT, n = 24) orthodontic treatment. Direct measurements of the final sample comprising 20 study models per group were performed using a digital caliper at the debonding stage, and 1 month, 3 months, and 6 months after debonding. Paired t-test, independent t-test, and non-parametric test were used for statistical analysis. Results: A significant increase (p < 0.01) in incisor irregularity was observed in both self-ligating and conventional system groups. A significant reduction (p < 0.01) in second interpremolar width was observed in both groups. Mandibular arch length decreased significantly (p = 0.001) in the conventional system group but not in the self-ligating system group. A similar pattern of stability was observed for intercanine width, first interpremolar width, intermolar width, and arch depth throughout the 6-month retention period after debonding. Comparison of incisor irregularity and arch dimension changes between self-ligating system and conventional system groups during the 6 months were non-significant. Conclusions: The stability of treatment outcomes for mild to moderate crowding malocclusions was similar between the self-ligating system and conventional system during the first 6 months of retention.

Innovative customized CAD/CAM nickel-titanium lingual retainer versus standard stainless-steel lingual retainer: A randomized controlled trial

  • Gelin, Emilie;Seidel, Laurence;Bruwier, Annick;Albert, Adelin;Charavet, Carole
    • 대한치과교정학회지
    • /
    • 제50권6호
    • /
    • pp.373-382
    • /
    • 2020
  • Objective: To compare computer-aided design and computer-aided manufacturing (CAD/CAM) customized nitinol retainers with standard stainless-steel fixed retainers over a 12-month study period. Methods: This randomized controlled trial (RCT) was conducted on 62 patients randomly allocated to a control group that received stainless-steel retainers or a test group that received customized CAD/CAM nickel-titanium retainers. Four time points were defined: retainer placement (T0) and 1-month (T1), 6-month (T2), and 12-month (T3) follow-up appointments. At each time point, Little's irregularity index (LII) (primary endpoint) and dental stability measurements such as intercanine width were recorded in addition to assessment of periodontal parameters. Radiological measurements such as the incisor mandibular plane angle (IMPA) were recorded at T0 and T3. Failure events (wire integrity or debonding) were assessed at each time point. Results: From T0 to T3, LII and other dental measurements showed no significant differences between the two groups. The data for periodontal parameters remained stable over the study period, except for the gingival index, which was slightly, but significantly, higher in the test group at T3 (p = 0.039). The IMPA angle showed no intergroup difference. The two groups showed no significant difference in debonding events. Conclusions: This RCT conducted over a 12-month period demonstrated no significant difference between customized CAD/CAM nickel-titanium lingual retainers and standard stainless-steel lingual retainers in terms of dental anterior stability and retainer survival. Both retainers eventually appeared to be equally effective in maintaining periodontal health.