• Title/Summary/Keyword: digital materials

Search Result 1,738, Processing Time 0.027 seconds

THE EFFECT OF INTRACANAL BASE ON PREVENTION OF APICAL LEAKAGE OF BLEACHING AGENTS (무수치 표백술에서 근관내 Base가 표백약제의 누출 방지에 미치는 영향)

  • Choi, Seung-Ho;Ro, Byeng-Duck;Park, Sung-Ho;Lee, Seung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.3
    • /
    • pp.453-464
    • /
    • 1999
  • The non-vital bleaching technique has been used widely as a very effective treatment method on discolored non-vital teeth. But periodontal tissue deterioration and cervical external root resorption have been reported because of the high toxicity of hydrogen peroxide in bleaching agents. So in previous studies, placement of base over the root canal obturation prior to bleaching has been suggested in order to prevent microleakage of bleaching agents, however, the effectiveness of base is still controversial. The purpose of this study was to evaluate the effects of base and root canal sealer on prevention of leakage of bleaching agents in non-vital bleaching. Fifty-two extracted sound teeth with single root were used. For root canal obturation, Tubuli seal$^{(R)}$(Kerr Co., USA) was used in 39 teeth and in others, AH-26$^{(R)}$(De Trey Dentsply, Inc., Switzerland) was used as a root canal sealer. 26 teeth among the teeth obturated with Tubuli seal$^{(R)}$ were divided into two groups, and Dentin cement$^{(R)}$(GC corp., Japan) and JRM$^{(R)}$(De Trey Dentsply, Inc. Germany) were used in each group as a intracanal base. In all teeth, non-vital bleaching using bleaching agent mixed with methylene blue dye was performed and all specimens were stored in $37^{\circ}C$ water bath for 72 hours. After sectioning longitudinally, the depth of dye leakage was measured with digital vernier calipers under the stereobinocular microscope using ${\times}40$ magnification. It can be concluded as follows: 1. The microleakage of bleaching agent was observed ill all groups regardless of type of the base and the sealer. 2. The microleakage in the groups using AH-26$^{(R)}$ as a sealer was significantly reduced (p<0.05). 3. In the groups with intracanal base, micro leakage was observed through almost the whole depth of the base and there was no significant difference between Dentin cement$^{(R)}$ and IRM$^{(R)}$ group(p>0.05). In conclusion, all the basing materials and the sealers in this study did not prevent the microleakage of bleaching agent. Therefore further studies and attempts to seal off the pulp chamber will be necessary.

  • PDF

An investigation of reosseointegration according to time course after mechanical loosening of the osseointegrated implant fixtures (표면처리 임플란트 고정체의 의원성 동요 후 시간 경과에 따른 재골유착에 관한 연구)

  • Ye, Sun-Hae;Cho, Jin-Hyun;Lee, Cheong-Hee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.31 no.3
    • /
    • pp.203-211
    • /
    • 2015
  • Purpose: The purpose of this study was to investigate the reosseointegration periods when the rough surface implants, which had complete bone-implant ankylosis, suddenly losed the osseointegration. Materials and Methods: The implants with RBM surface treatment were inserted into both tibias of 23 rabbits. Two implants were submerged into each side. After six weeks, the primary removal torque was measured by Digital torque gauge, and then the implants were replaced and submerged to estimate the level of reosseointegration. After assigned healing periods for each group, the removal torque was measured again. BIC (Bone-Implant contact, %) ratio was measured through histomorphometric analysis.Paired t-test was processed by SPSS 14.0. One-way ANOVA and Tukey's post-hoc test was processed to analyze statistically significant differences among the groups. Results: In comparison with the primary removal torque, the secondary removal torque was increased after 11 days and significantly increased from 2 weeks. In fluorochrome labeling, the origin of mineralization was observed after 7 days, which showed as fluorescent bands around the bone-implant interfaces. After 11 days, the bone formation was apparent, and it is increased continuously with the passage of the time. Conclusion: In 11 days after the implant replacement, the secondary removal torque was almost as same as the primary value, and was significantly higher from 2 weeks. The mineralized shapes were observed in 7 days after the implant replacement, and then the bone formation appeared visibly in 11 days.

Susceptibility Vessel Sign for the Detection of Hyperacute MCA Occlusion: Evaluation with Susceptibility-weighted MR Imaging

  • Lee, Sangmin;Cho, Soo Bueum;Choi, Dae Seob;Park, Sung Eun;Shin, Hwa Seon;Baek, Hye Jin;Choi, Ho Cheol;Kim, Ji-Eun;Choi, Hye Young;Park, Mi Jung
    • Investigative Magnetic Resonance Imaging
    • /
    • v.20 no.2
    • /
    • pp.105-113
    • /
    • 2016
  • Purpose: Susceptibility vessel sign (SVS) on gradient echo image, which is caused by MR signal loss due to arterial thrombosis, has been reported in acute middle cerebral artery (MCA) infarction. However, the reported sensitivity and diagnostic accuracy of SVS have been variable. Susceptibility-weighted imaging (SWI) is a newly developed MR sequence. Recent studies have found that SWI may be useful in the field of cerebrovascular diseases, especially for detecting the presence of prominent veins, microbleeds and the SVS. The purpose of this study was to evaluate the diagnostic values of SWI for the detection of hyperacute MCA occlusion. Materials and Methods: Sixty-nine patients (37 males, 32 females; 46-89 years old [mean, 69.1]) with acute stroke involving the MCA territory underwent MR imaging within 6 hours after the symptom onset. MR examination included T2, FLAIR (fluid-attenuated inversion recovery), DWI, SWI, PWI (perfusion-weighted imaging), contrast-enhanced MR angiography (MRA) and contrast-enhanced T1. Of these patients, 28 patients also underwent digital subtraction angiography (DSA) within 2 hours after MR examination. Presence or absence of SVS on SWI was assessed without knowledge of clinical, DSA and other MR imaging findings. Results: On MRA or DSA, 34 patients (49.3%) showed MCA occlusion. Of these patients, SVS was detected in 30 (88.2%) on SWI. The sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy of SWI were 88.2%, 97.1%, 96.8%, 89.5% and 92.8%, respectively. Conclusion: SWI was sensitive, specific and accurate for the detection of hyperacute MCA occlusion.

Accuracy of spring-style and friction-style mechanical implant torque wrench (스프링형과 마찰형 기계식 임플란트 토크 렌치의 정확도에 관한 연구)

  • Cha, Dong-Hee;Oh, Sang-Chun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.1
    • /
    • pp.8-13
    • /
    • 2016
  • Purpose: The aim of this study was to compare the accuracy of two different styles of mechanical implant torque wrenches before and after sterilization and repeated use. Materials and methods: Thirty new spring-style and friction-style mechanical implant torque wrenches from five different manufacturers were selected as subjects of study and assessed in terms of accuracy. Three manufacturers produced, spring-style (Dio, Neobiotech, Osstem) torque wrenches, and other three manufactures produced friction-style (Dentium, Osstem, Shinhung) torque wrenches. The procedure of target torque measurement was performed 10 times for each device and a digital torque gauge (MGT-12, Mark-10 Corp, USA) was used to record the measurements. All torque wrenches were used repeatedly for 20 times and then sterilized. This whole procedure was repeated 100 times and all torque wrenches were retested. The collected data was analyzed using a SPSS Statistics Analysis program to evaluate the accuracy of the torque wrenches and Mann-Whitney-U test was used for a comparative analysis. Results: After sterilization and repeated use procedure, results did not show any significant difference between error values in the spring-style torque wrench group. However, the results demonstrated an increase in error values within the friction-style torque wrench group (P<.05). Conclusion: There was no difference between the accuracy of new spring-style torque wrenches before and after 100 cycles of sterilization and repeated use (P>.05). There was significant difference between the accuracy of new friction-style torque wrenches before and after 100 cycles of sterilization and repeated use (P<.05). Within the limitation of this study, spring-style torque wrenches were more accurate than friction-style torque wrenches in delivering target torque values.

A determination of occlusal plane comparing different levels of the tragus to form ala-tragal line or Camper's line: A photographic study

  • Kumar, Sandeep;Garg, Sandeep;Gupta, Seema
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.1
    • /
    • pp.9-15
    • /
    • 2013
  • PURPOSE. The purpose of this study was to determine accurately the part of the tragus to be used to form the Ala-Tragal line or Camper's line in orthognathic profile patients. MATERIALS AND METHODS. 150 dentate subjects with age of 18-40 years with orthognathic profile were sampled. Life-size lateral digital photographs of the face with fox plane were taken in natural head position. Different angles between Eye-Ear plane and occlusal plane ($OT_1$-OP), Eye-Ear plane and ala-superior border of tragus ($OT_1-AT_1$), Eye-Ear plane and ala-middle border of tragus ($OT_1-AT_2$) and Eye-Ear plane and ala-inferior border of tragus ($OT_1-AT_3$) were calculated using computer software package, AutoCAD 2004. From the three angles formed by the Eye-ear plane ($OT_1$ or FH plane) and the ala-tragal lines, the one closest to the angle formed between Eye-Ear plane ($OT_1$) and occlusal plane (OP) was used to determine the occlusal plane of orientation. The obtained results were subjected to ANOVA F test, Tukey's Honestly significant difference test, followed by Karl Pearson coefficient of correlation test. P values of less than 0.05 were taken as statistically significant. RESULTS. The mean of base line angle i.e. $OT_1$-OP angle ($11.96{\pm}4.36$) was found to be close to $OT_1-AT_2$ angle ($13.67{\pm}1.93$) and $OT_1-AT_3$ angle ($10.31{\pm}2.03$), but $OT_1$-OP angle was found to be more closer to $OT_1-AT_3$ angle. Comparison of mean angles showed that $OT_1$-OP angle in both males (11.68) and females (12.51) is close to $OT_1-AT_3$ angle (males- 11.01, females- 11.95). CONCLUSION. The line joining from ala to the lower border of the tragus was parallel to the occlusal plane in 53.3% of the subjects. There was no influence of the sex on the level of occlusal plane.

Development and Application of Mobile-Based Math Learning Application (모바일 기반 수학 학습 어플리케이션 개발 및 활용 방안)

  • Kim, Bumi
    • School Mathematics
    • /
    • v.19 no.3
    • /
    • pp.593-615
    • /
    • 2017
  • The purpose of this study is to develop a mobile-based math learning application and explore its application. In order to develop a learning application, the present study included literature review on math education involving mobile learning, investigation of literature related to mathematics education conducted in a digital environment, and method of use and implementation environment of existing math learning applications by type. Based on these preliminary investigation and analysis, an android version application, 'Mathematics Classroom for Middle School 3rd Graders' was developed. This application can be used for learning units such as Quadratic Functions and Graphs, Representative Value, and Variance and Standard Deviation. For the unit on Quadratic Functions and Graphs, the application was constructed so that students can draw various graphs by using the graphic mode and discuss their work with other students in the chatting room. For the unit on Representative Value, the application was constructed with the mathematical concept of representative value explained through animation along with activities of grouping data acquired after playing archery games by points or arranging them according to size so that students can study when and how to use median value, mode, and average. The application for Variance and Standard Deviation unit was also constructed in a way that allowed students to study the concept of variance and standard deviation and solve the problems on their own. The results of this study can be used as teaching & learning materials customized for individual student in math classes and will provide anyone the opportunity to engage in an interesting self-directed learning of math at anytime. Developed in the format of real life study, the application will contribute to helping students develop a positive attitude about math.

A Development of Design database structure and Database Application System applicable for design Foundation Courses. (디자인 데이터베이스 체계구축 및 운용시스템 개발에 관한 연구 -기초조형교육을 중심으로-)

  • 이종호
    • Archives of design research
    • /
    • v.12 no.4
    • /
    • pp.283-292
    • /
    • 1999
  • As network and multimedia service has increased in educational environment, it is needed to study on digital system based educational scenarios, especially in art and design departments in which visual educational materials mainly used. Therefore, this study was conducted with three objectives: first, developing components of design database and their classification system, second, developing contents of database for fundamental form education in design, and third, developing application method of database. According to these objectives, the secondary research was implemented into two directions; the analysis of classification categories of design, and the analysis of contents and process of fundamental form design education. From the secondary research, it was found that design database should have a flexible structure with flexible components as well as fixed components to include subjective and aesthetic assessment. In the end, the application methods and user interface system of design database was developed based on design educational scenarios.

  • PDF

Head to Head Comparison of the Chun Nomogram, Percentage Free PSA and Primary Circulating Prostate Cells to Predict the Presence of Prostate Cancer at Repeat Biopsy

  • Murray, Nigel P;Reyes, Eduardo;Orellana, Nelson;Fuentealba, Cynthia;Jacob, Omar
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.6
    • /
    • pp.2941-2946
    • /
    • 2016
  • Background: The limitations of total serum PSA values remain problematic, especially after an initial negative prostate biopsy. In this prospective study of Chilean men with a continued suspicion of prostate cancer due to a persistently elevated total serum PSA, abnormal digital rectal examination and initial negative prostate biopsy were compared with the use of the on-line Chun nomagram, detection of primary malignant circulating prostate cells (CPCs) and free percent PSA to predict a positive second prostate biopsy. We hypothesized that men negative for circulating prostate cells have a small risk of clinically significant prostate cancer and thus may be conservatively observed. Men positive for circulating prostate cells should undergo biopsy to confirm prostate cancer. Materials and Methods: Consecutive men with a continued suspicion of prostate cancer underwent 12 core TRUS prostate biopsy; age, total serum PSA and percentage free PSA and Chun nomagram scores were registered. Immediately before biopsy an 8ml blood simple was taken to detect primary mCPCs. Mononuclear cells were obtained by differential gel centrifugation and identified using double immunostaining with anti-PSA and anti-P504S. Biopsies were classifed as cancer/no-cancer, mCPC detecton test as negative/positive and the total number of cells/8ml registered. Areas under the curve (AUC) for percentage free PSA, Chun score and CPCs were calculated and compared. Diagnostic yields were calculated with reference to the number of possible biopsies that could be avoided and the number of clinically significant cancers that would be missed. Results: A total of 164 men underwent a second biopsy; 41 (25%) had cancer; the AUCs were 0.65 for free PSA, 0.76 for the Chun score and 0.87 for CPC detection, the last having a significantly superior prediction value (p=0.01). Using cut off values of free PSA <10%, Chun score >50% and ${\geq}1$ CPC detected, CPC detection had a higher diagnostic yield. Some 4/41 cancers complied with the criteria for active surveillance, free PSA and the Chun score missed a higher number of significant cancers when compared with CPC detection. Conclusions: Primary CPC detection outperformed the use of free PSA and the Chun nomagram in predicting clinically significant prostate cancer at repeat prostate biopsy.

Vicarious Radiometric Calibration of the Ground-based Hyperspectral Camera Image (지상 초분광카메라 영상의 복사보정)

  • Shin, Jung-Il;Maghsoudi, Yasser;Kim, Sun-Hwa;Kang, Sung-Jin;Lee, Kyu-Sung
    • Korean Journal of Remote Sensing
    • /
    • v.24 no.2
    • /
    • pp.213-222
    • /
    • 2008
  • Although hyperspectral sensing data have shown great potential to derive various surface information that is not usually available from conventional multispectral image, the acquisition of proper hyperspectral image data are often limited. To use ground-based hyperspectral camera image for remote sensing studies, radiometric calibration should be prerequisite. The objective of this study is to develop radiometric calibration procedure to convert image digital number (DN) value to surface reflectance for the 120 bands ground-based hyperspectral camera. Hyperspectral image and spectral measurements were simultaneously obtained from the experimental target that includes 22 different surface materials of diverse spectral characteristics at wavelength range between 400 to 900 nm. Calibration coefficients to convert image DN value to at-sensor radiance were initially derived from the regression equations between the sample image and spectral measurements using ASD spectroradiometer. Assuming that there is no atmospheric effects when the image acquisition and spectral measurements were made at very close distance in ground, we were also able to derive calibration coefficients that directly transform DN value to surface reflectance. However, these coefficients for deriving reflectance values should not be applied when the camera is used for aerial image that contains significant effect from atmosphere and further atmospheric correction procedure is required in such case.

Initial Experience of Transperineal Biopsy After Multiparametric Magnetic Resonance Imaging in Korea; Comparison With Transrectal Biopsy

  • Yoon, Sung Goo;Jin, Hyun Jung;Tae, Jong Hyun;No, Tae Il;Kim, Jae Yoon;Pyun, Jong Hyun;Shim, Ji Sung;Kang, Sung Gu;Cheon, Jun;Lee, Jeong Gu;Kim, Je Jong;Sung, Deuk Jae;Lee, Kwan Hyi;Kang, Seok Ho
    • The Korean Journal of Urological Oncology
    • /
    • v.16 no.3
    • /
    • pp.110-118
    • /
    • 2018
  • Purpose: The aim of this study is to confirm the detection rate of transperineal biopsy after multiparametric magnetic resonance imaging (mpMRI) and compared it to that of transrectal biopsy. We also examined the role of mpMRI and the rate of complications for each method. Materials and Methods: In a retrospective study, we analyzed 147 patients who underwent mpMRI before prostate biopsy because of elevated serum prostate-specific antigen and/or abnormal digital rectal examination findings at Korea University Hospital, Seoul, Korea from March 2017 to April 2018. Regions on the mpMRI that were suggestive of prostate cancer were categorized according to the Prostate Imaging-Reporting and Data System (PI-RADS v2). For transperineal biopsy, a 20-core saturation biopsy was performed by MRI-TRUS cognitive or fusion techniques and a 12-core biopsy was performed in transrectal biopsy. Results: Sixty-three and 84 patients were enrolled in transperineal group and transrectal group, respectively. The overall detection rate of prostate cancer in transperineal group was 27% higher than that in transrectal group. Classification according to PI-RADS score revealed a significant increase in detection rate in all patients, as the PI-RADS score increased. Frequency of complications using the Clavien-Dindo classifications revealed no significant differences in the total complications rate, but two patients in transrectal group received intensive care unit care due to urosepsis. Conclusions: Our results confirmed that transperineal biopsy is superior to transrectal biopsy for the detection of prostate cancer. From the complication point of view, this study confirmed that there were fewer severe complications in transperineal biopsy.