Development of Digital Surface Model and Feature Extraction by Integrating Laser Scanner and CCD sensor

  • Nagai, Masahiko;Shibasaki, Ryosuke;Zhao, Huijing;Manandhar, Dinesh
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.859-861
    • /
    • 2003
  • In order to present a space in details, it is indispensable to acquire 3D shape and texture simultaneously from the same platform. 3D shape is acquired by Laser Scanner as point cloud data, and texture is acquired by CCD sensor. Positioning data is acquired by IMU (Inertial Measurement Unit). All the sensors and equipments are assembled on a hand-trolley. In this research, a method of integrating the 3D shape and texture for automated construction of Digital Surface Model is developed. This Digital Surface Model is applied for efficient feature extraction. More detailed extraction is possible , because 3D Digital Surface Model has both 3D shape and texture information.

  • PDF

Precision of Digital Photogrammetry for the Roughness Measurement of Rock Surfaces

  • Lee, Hyo-Sung;Ahn, Ki-Won;Park, Byung-Uk;Kim, Yong-Il
    • Korean Journal of Geomatics
    • /
    • v.3 no.1
    • /
    • pp.43-51
    • /
    • 2003
  • This paper presents the benefits of using close-range digital photogrammetric techniques for measuring the roughness of rock surfaces, using digital stereo images obtained from a Rolleiflex 6006 metric camera. To precisely measure surface roughness, we researched on how to use the flat and curved reference surface obtained from geometrically corrected digital images of the rock surface by using the least squares method. To test the precision of the proposed technique, the surface roughness has been measured between the reference surface and sample areas of very smooth-surfaced rock. Then the results were compared with the measurements obtained from a laser sensor profilometer.

  • PDF

Ceramic molar crown reproducibility by digital workflow manufacturing: An in vitro study

  • Jeong, II-Do;Kim, Woong-Chul;Park, Jinyoung;Kim, Chong-Myeong;Kim, Ji-Hwan
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.4
    • /
    • pp.252-256
    • /
    • 2017
  • PURPOSE. This in vitro study aimed to analyze and compare the reproducibility of zirconia and lithium disilicate crowns manufactured by digital workflow. MATERIALS AND METHODS. A typodont model with a prepped upper first molar was set in a phantom head, and a digital impression was obtained with a video intraoral scanner (CEREC Omnicam; Sirona GmbH), from which a single crown was designed and manufactured with CAD/CAM into a zirconia crown and lithium disilicate crown (n=12). Reproducibility of each crown was quantitatively retrieved by superimposing the digitized data of the crown in 3D inspection software, and differences were graphically mapped in color. Areas with large differences were analyzed with digital microscopy. Mean quadratic deviations (RMS) quantitatively obtained from each ceramic group were statistically analyzed with Student's t-test (${\alpha}=.05$). RESULTS. The RMS value of lithium disilicate crown was $29.2\;(4.1){\mu}m$ and $17.6\;(5.5){\mu}m$ on the outer and inner surfaces, respectively, whereas these values were $18.6\;(2.0){\mu}m$ and $20.6\;(5.1){\mu}m$ for the zirconia crown. Reproducibility of zirconia and lithium disilicate crowns had a statistically significant difference only on the outer surface (P<.001). The outer surface of lithium disilicate crown showed over-contouring on the buccal surface and under-contouring on the inner occlusal surface. The outer surface of zirconia crown showed both over- and under-contouring on the buccal surface, and the inner surface showed under-contouring in the marginal areas. CONCLUSION. Restoration manufacturing by digital workflow will enhance the reproducibility of zirconia single crowns more than that of lithium disilicate single crowns.

New Ramp-reset Waveform for Fast Addressing in AC-PDPs

  • Kim, Oe-Dong;Ahn, Byoung-Nam;Choi, Kwang-Yeol;Yoo, Eun-Ho
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07a
    • /
    • pp.643-646
    • /
    • 2005
  • We present new ramp-reset waveforms that realize fast addressing in AC-PDPs. These waveforms distort the distribution of wall charges on the surface of a phosphor layer: hence, the enhanced electric field helps to ignite a cell faster. They also reduce the black luminance: the divide of erasing ramp down discharges into two parts, i.e. a surface discharge and a vertical discharge, makes lower luminance.

  • PDF

REMARKS ON DIGITAL HOMOTOPY EQUIVALENCE

  • Han, Sang-Eon
    • Honam Mathematical Journal
    • /
    • v.29 no.1
    • /
    • pp.101-118
    • /
    • 2007
  • The notions of digital k-homotopy equivalence and digital ($k_0,k_1$)-homotopy equivalence were developed in [13, 16]. By the use of the digital k-homotopy equivalence, we can investigate digital k-homotopy equivalent properties of Cartesian products constructed by the minimal simple closed 4- and 8-curves in $\mathbf{Z}^2$.

Reconstructing individual hand models from motion capture data

  • Endo, Yui;Tada, Mitsunori;Mochimaru, Masaaki
    • Journal of Computational Design and Engineering
    • /
    • v.1 no.1
    • /
    • pp.1-12
    • /
    • 2014
  • In this paper, we propose a new method of reconstructing the hand models for individuals, which include the link structure models, the homologous skin surface models and the homologous tetrahedral mesh models in a reference posture. As for the link structure model, the local coordinate system related to each link consists of the joint rotation center and the axes of joint rotation, which can be estimated based on the trajectories of optimal markers on the relative skin surface region of the subject obtained from the motion capture system. The skin surface model is defined as a three-dimensional triangular mesh, obtained by deforming a template mesh so as to fit the landmark vertices to the relative marker positions obtained motion capture system. In this process, anatomical dimensions for the subject, manually measured by a caliper, are also used as the deformation constraints.

A method for mandibular dental arch superimposition using 3D cone beam CT and orthodontic 3D digital model

  • Park, Tae-Joon;Lee, Sang-Hyun;Lee, Ki-Soo
    • The korean journal of orthodontics
    • /
    • v.42 no.4
    • /
    • pp.169-181
    • /
    • 2012
  • Objective: The purpose of this study was to develop superimposition method on the lower arch using 3-dimensional (3D) cone beam computed tomography (CBCT) images and orthodontic 3D digital modeling. Methods: Integrated 3D CBCT images were acquired by substituting the dental portion of 3D CBCT images with precise dental images of an orthodontic 3D digital model. Images were acquired before and after treatment. For the superimposition, 2 superimposition methods were designed. Surface superimposition was based on the basal bone structure of the mandible by surface-to-surface matching (best-fit method). Plane superimposition was based on anatomical structures (mental and lingual foramen). For the evaluation, 10 landmarks including teeth and anatomic structures were assigned, and 30 times of superimpositions and measurements were performed to determine the more reproducible and reliable method. Results: All landmarks demonstrated that the surface superimposition method produced relatively more consistent coordinate values. The mean distances of measured landmarks values from the means were statistically significantly lower with the surface superimpositions method. Conclusions: Between the 2 superimposition methods designed for the evaluation of 3D changes in the lower arch, surface superimposition was the simpler, more reproducible, reliable method.

Shrink-Wrapped Boundary Face Algorithm for Mesh Reconstruction from Unorganized Points

  • Koo, Bon-Ki;Choi, Young-Kyu;Chu, Chang-Woo;Kim, Jae-Chul;Choi, Byoung-Tae
    • ETRI Journal
    • /
    • v.27 no.2
    • /
    • pp.235-238
    • /
    • 2005
  • A new mesh reconstruction scheme for approximating a surface from a set of unorganized 3D points is proposed. The proposed method, called a shrink-wrapped boundary face (SWBF) algorithm, produces the final surface by iteratively shrinking the initial mesh generated from the definition of the boundary faces. SWBF surmounts the genus-0 spherical topology restriction of previous shrink-wrapping-based mesh generation techniques and can be applied to any type of surface topology. Furthermore, SWBF is significantly faster than a related algorithm of Jeong and others, as SWBF requires only a local nearest-point-search in the shrinking process. Our experiments show that SWBF is very robust and efficient for surface reconstruction from an unorganized point cloud.

  • PDF

Periodontal attachment loss of extracted teeth for periodontal reasons (발거치에 나타난 부착상실의 양상에 대한 연구)

  • Kim, Jung-Hyun;Kim, Sung-Jo;Choi, Jeom-Il;Lee, Ju-Youn
    • Journal of Periodontal and Implant Science
    • /
    • v.36 no.1
    • /
    • pp.61-68
    • /
    • 2006
  • The factors influencing long-term prognosis of teeth must be carefully considered. Among these, attachment level is strongly associated with tooth loss. The purpose of the present study was to estimate pattern of attachment loss based on attachment area in extracted teeth. 197 satisfied the criteria for assessment after staining. The protocol described by Waerhaug(l975) was performed. An indir ect method, based on digital image abstracted from digital camera and digital imaging software program, was used to calculate the root surface area and the attachment loss area. The data were analysed using SPSS. Except maxillary central incisior and mandibular canine, no statistical significant differences between each root surfaces were observed in anterior teeth. In posterior teeth, statistical significant differences in palatal surface of maxillary molar and mandibular molar compared with others were observed. Statistical significant difference in buccal surface compared with others was lowly observed in single and multi rooted. This study did not reveal progressive loss pattern of attachment area in each root surface but clarified root surface that has relative high loss rate of attachment area at extraction. Thus understanding this pattern of attachment loss is helpful for dentist to treat the periodontitis.