• Title/Summary/Keyword: digital fire control system

Search Result 27, Processing Time 0.023 seconds

A performance improvement method in the gun fire control system compensating for measurement bias error of the target tracking sensor (표적추적센서의 측정 바이어스 오차 보상에 의한 사격통제장치 성능 향상 기법)

  • Kim, Jae-Hun;Lyou, Joon
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.3 no.2
    • /
    • pp.121-130
    • /
    • 2000
  • A practical method is proposed to improve hit probability of the digital gun fire control system, when the measured rate of the tracking sensor becomes biased under some operational situation. For ground moving target it is shown that the well-known Kalman filter which uses position measurement only can be optimally used to eliminate the rate bias error. On the other hand, for 3D moving aircraft we present a new algorithm which incorporate FIR-type filter, which uses position and rate measurement at the same time, and the fixed-lag smoother using position measurement only, and show that it has the optimal performance in terms of both estimation accuracy and response time.

  • PDF

Integrated Fire Monitoring System Based on Wireless Multi-Hop Sensor Network and Mobile Robot (무선 멀티 홉 센서 네트워크와 이동로봇을 이용한 통합 화재 감시 시스템)

  • Kim, Tae-Hyoung;Seo, Gang-Lae;Lee, Jae-Yeon;Lee, Won-Chang
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.16 no.2
    • /
    • pp.114-119
    • /
    • 2010
  • Network technology has been developed rapidly for digital service in these days. ZigBee, one of the IEEE 802.15.4 protocols, supporting local communication has become the core technology in the wireless network area. In this paper we designed an integrated fire monitoring system using a mobile robot and the ZigBee sensor nodes which are deployed to monitor fires. When a fire breaks out, the image information of the scene of a fire is transmitted by an autonomous mobile robot and we also monitor the current position of the robot. Furthermore, the data around the place where the fire breaks out and the positions of the sensor nodes can be transmitted to a server via the multi-hop communication in the real time.

Research on the Reliability Improvement of Automatic Fire Alarm System (자동화재탐지설비의 신뢰성 개선에 관한 연구)

  • Son, Young-Jin;Lee, Young-Il;Lee, Sang-Hyeon
    • Fire Science and Engineering
    • /
    • v.22 no.4
    • /
    • pp.42-49
    • /
    • 2008
  • This research is to provide a scheme for an automatic fire alarm system with higher reliability through solving problems of malfunctioning (false or missing fire alarm) and power interruption (result from frequently unwanted activation, etc) of an automatic fire alarm system. A digital control system with microprocessor-based is proposed to reduce the possibility of malfunctioning through a combinational use of heat, smoke and CO sensors. Higher reliability could be achieved by these multiple sensors based fire detection system and fire distinction algorithm. In this research, we implemented actual fire detection system and conducted fire test to verify improvement on reliability.

Study on IoT-based Map Inside the Building and Fire Perception System (IoT 기반 건물 내부 지도 및 화재 안내 시스템에 관한 연구)

  • Moon, Sung-Ryong;Cho, Joon-Ho
    • Journal of Digital Convergence
    • /
    • v.17 no.1
    • /
    • pp.85-90
    • /
    • 2019
  • This paper is a study on IoT based map inside the building and fire perception system using microprocessor and LABVIEW program. The smart control system implemented in this paper is designed to identify the location of fire by using microprocessor, flame detection sensor, carbon monoxide sensor and temperature sensor, and to guide the optimal travel route through Zigbee communication. And the proposed system uses QR code to interoperate with smartphone. The coordinator control verified that the sensor value of the smart control system installed through the LABVIEW software was confirmed. The IoT based control system studied in this paper was implemented with Arduino mega board and LABVIEW software, and the operation status was confirmed by display device and coordination.

A study on the implementation of digital anti-fire monitoring system with multipoint communication protocol (다중포인트 통신 프로토콜을 지원하는 디지털 화재 방지 모니터링 시스템 구현에 관한 연구)

  • Kim, Ki-Jung
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.7 no.6
    • /
    • pp.1423-1428
    • /
    • 2012
  • In this paper, we investigated an implementation of anti-fire monitoring system based on the RS-485 communication to support local area coverage within a range of 1 Km range. We developed a Multi Point Communication Protocol supporting input/output information processing and control up to 8128 terminal check points, which provides an interface between the anti-fire monitoring system receiver and multiplex transponders. Additionally, a multiplex transponders controller has been designed for the implemented system to comply with the government regulation on fire protection, especially to monitor, report and control 1016 terminal check points within the time limit.

Fire Extinguisher Maintenance System using Smart NFC Communication and Real-Time Pressure Measurement (스마트 NFC 통신과 실시간 압력 측정을 이용한 소화기 유지관리 시스템)

  • Park, Byeng-Cheol;Park, Ki-Hong
    • Journal of Digital Contents Society
    • /
    • v.18 no.2
    • /
    • pp.403-410
    • /
    • 2017
  • In this paper, the fire extinguisher maintenance system using smart NFC communication and the real-time pressure measurement is proposed. The proposed system consists of three steps in the flow of information. The first step is to identify the fire extinguisher through NFC tagging in the fire extinguisher module using the smart device. The fire extinguisher appearance check and the real-time pressure measurement is performed in the second step, and the last step sends the check status information to the management server. In particular, the actual pressure value is calculated based on the angle of the green area and the indicating needle. Some experiments are conducted so as to verify the proposed system, and as a result, the proposed system shows that the administrator can effectively control the status information of fire safety check.

A Study on Development of App-Based Electric Fire Prediction System (앱기반 전기화재 예측시스템 개발에 관한 연구)

  • Choi, Young-Kwan;Kim, Eung-Kwon
    • Journal of Internet Computing and Services
    • /
    • v.14 no.4
    • /
    • pp.85-90
    • /
    • 2013
  • Currently, the electric fire prediction system uses PIC(Peripheral Interface Controller) for controller microprocessor. PIC has a slower computing speed than DSP does, so its real-time computing ability is inadequate. So with the basic characteristics waveform during arc generation as the standard reference, the comparison to this reference is used to predict and alarm electric fire from arc. While such alarm can be detected and taken care of from a remote central server, that prediction error rate is high and remote control in mobile environment is not available. In this article, the arc detection of time domain and frequency domain and wavelet-based adaptation algorithm executing the adaptation algorithm in conversion domain were applied to develop an electric fire prediction system loaded with new real-time arc detection algorithm using DSP. Also, remote control was made available through iPhone environment-based app development which enabled remote monitoring for arc's electric signal and power quality, and its utility was verified.

Rotational Drive-Versus-Quality and Video Compression-Versus-Delay Analysis for Multi-Channel Video Streaming System on Ground Combat Vehicles (지상 전투 차량을 위한 다채널 영상 스트리밍 시스템의 회전 구동 대비 품질과 압축 대비 지연 분석)

  • Yun, Jihyeok;Cho, Younggeol;Chang, HyeMin
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.24 no.1
    • /
    • pp.31-40
    • /
    • 2021
  • The multi-channel video streaming system is an essential device for future ground combat vehicles. For the system, the application of digital interfaces is required instead of the direct analog method to support selectable multiple channels. However, due to the characteristics of the digital interfaces that require en/decoding and signal conversion, the system should support the ability to adapt to quality and delay requirements depending on how video data is utilized. To support addressed issue, this study designs and emulates the multi-channel compressed-video streaming system of ground combat vehicle's fire control system based on commercial standards. Using the system, this study analyzes the quality of video according to the rotational speed of the acquisition device and Glass-to-Glass (G2G) delay between video acquisition and display devices according to video compression rates. Through these experiments and analysis, this paper presents the design direction of the system having scalability on the latest technology while providing high-quality video data streaming flexibly.

Study on the Analysis of Differential Pressure of the Access Door for a Smoke Control Zone and the Effectiveness of the Measurement Criteria of its Opening Force (제연구역 출입문의 차압 및 개방력 측정기준의 실효성 분석에 관한 연구)

  • Lee, Jae-Ou;Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.26 no.4
    • /
    • pp.24-30
    • /
    • 2012
  • The purpose of this study is to analyze the problem in measuring the differential pressure between the fire area and the neighboring smoke control zone as well as the opening force of a fire door and to present the actual values measured by an objective method. NFSC 501A specifies that the force necessary to open an access door when operating a smoke control system shall be less than 110 N. When the smoke control system does not operate in the space where it is installed, the door opening force can be measured by the test method in KS F 2805. However, when the smoke control system operates, additional opening force is required to overcome the force generated by the differential pressure between the fire area and smoke control room. Therefore, it can be seen that the method proposed by the standard has insufficient reliability. The analog measuring device and digital measuring device showed that the opening forces, $F_a$ and $F_d$, of the fully closed door before the smoke control system were 27.8 N and 27.4 N, respectively. When the door remained open by $5^{\circ}$, the opening forces, $F_a$ and $F_d$, were 33 N and 33.6 N, respectively. When the smoke control system operated and the door was fully closed, the door opening forces, $F_a$ and $F_d$, were 77.6 N and 76.0 N, respectively. Therefore, since the door opening forces are different from the criteria presented by KS F 2805, it is required to review the criteria appropriately.

A Study on Intelligent Space Design Supporting the Elderly - Focused on the Needs of the Aged on Digital Systems in Residential Space - (노인을 위한 지능형 공간환경 연구 - 주거공간의 디지털 시스템화를 위한 노인요구 조사를 중심으로 -)

  • Oh, Chan-Ohk
    • Korean Institute of Interior Design Journal
    • /
    • v.17 no.5
    • /
    • pp.61-71
    • /
    • 2008
  • The study alms to seek a plan of applying the digital technology to housing for the elderly. The purpose of the study was to grasp the needs of the aged on 30 types of digital systems in housing. The subjects were 120 persons aged of more than 60 years and lived in Busan. Data were collected by the individual interview. The following results were drawn from this study. First, the needs of the aged on the digital systems categorized as safe and security, control of indoor environment, and housework support were very high and should be provided at first. Second, the necessary types of digital systems which should be provided to the digital home for the elderly were digital systems for heating control, health checking, sensing of fire and gas leak, and house cleaning. Also, the basic types of digital systems were ones for invasion and burglarproof, emergency, air cleaning, automatic facet, door locking, and waste collecting. Third, the Income and usage level of digital equipment of the aged influenced to the floods of the aged on the digital system. Therefore, in addition to the necessary and basic types of digital systems mentioned above, the income and usage level of digital equipment should be considered in planning the digital home for the elderly.