디지털 방사선영상 시스템의 기본적 원리 (Physical principles of digital radiographic imaging system)

  • 최진우;이원진
    • Imaging Science in Dentistry
    • /
    • 제40권4호
    • /
    • pp.155-158
    • /
    • 2010
  • Digital radiographic systems allow the implementation of a fully digital picture archiving and communication system (PACS), and provide the greater dynamic range of digital detectors with possible reduction of X-ray exposure to the patient. This article reviewed the basic physical principles of digital radiographic imaging system in dental clinics generally. Digital radiography can be divided into computed radiography (CR) and direct radiography (DR). CR systems acquire digital images using phosphor storage plates (PSP) with a separate image readout process. On the other hand, DR systems convert X-rays into electrical charges by means of a direct readout process. DR systems can be further divided into direct and indirect conversion systems depending on the type of X-ray conversion. While a direct conversion requires a photoconductor that converts X-ray photons into electrical charges directly, in an indirect conversion, lightsensitive sensors such as CCD or a flat-panel detector convert visible light, proportional to the incident X-ray energy by a scintillator, into electrical charges. Indirect conversion sensors using CCD or CMOS without lens-coupling are used in intraoral radiography. CR system using PSP is mainly used in extraoral radiographic system and a linear array CCD or CR sensors, in panoramic system. Currently, the digital radiographic system is an important subject in the dental field. Most studies reported that no significant difference in diagnostic performance was found between the digital and conventional systems. To accept advances in technology and utilize benefits provided by the systems, the continuous feedback between doctors and manufacturers is essential.

비정질 실리콘 디지털 방사선 촬영기의 개발 (Development of Amorphous Silicon Based Digital Radiography System)

  • 이형구;서태석;최보영;신경섭;김홍권
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1998년도 추계학술대회
    • /
    • pp.94-95
    • /
    • 1998
  • We developed a digital x-ray medical imaging system using commercially available amorphous silicon image sensor plate. The image readout could be accomplished within 3.5 sec after radiation exposure and be displayed on a monitor through computer interface. This system needs not the conventional x-ray films and film processors, and also provides digital radiographic images. This system is the fastest digital radiography system developed so far, and expected to replace many of the conventional x-ray film systems or digital radiography systems.

  • PDF

Thermal Characteristics of Rotating Anode X-ray Tube with Emissivity in Aging Process for Digital Radiography

  • Lee, Seok Moon
    • Applied Science and Convergence Technology
    • /
    • 제24권5호
    • /
    • pp.125-131
    • /
    • 2015
  • We investigated the thermal characteristics of rotating anode X-ray tube to develop it for digital radiography by using computer simulation. The target which is the area of the anode struck by electrons is the most important component to get a long life of X-ray tube. So we analyze the thermal characteristics of the target and rotor assembly according to their emissivity by using ANSYS transient thermal simulation and then compare with the measured data of the target temperature operating in aging process of X-ray tube. Especially, keeping the lead coated layer as the role of metal lubricant on ball bearing enables to prevent the noise in rotating anode. The simulation result showed that its temperature was under the melting point of the lead in X-ray tube for digital radiography with 1.2 mm large focal spot 0.6 mm small focal spot and 150 kV tube voltage. We also investigated the relationship between the diameter of the anode shaft and the temperature of the anode and rotor assembly. It has been confirmed that the smaller anode shaft could be good for the rotor thermal characteristics.

On the Development of Digital Radiography Detectors: A Review

  • Kim, Ho-Kyung;Cunningham, Ian Alexander;Yin, Zhye;Cho, Gyu-Seong
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제9권4호
    • /
    • pp.86-100
    • /
    • 2008
  • This article reviews the development of flat-panel detectors for digital radiography based on amorphous materials, Important design parameters and developments are described for the two main components of flat-panel detectors: the X-ray converter and the readout pixel array. This article also introduces the advanced development concepts of new detectors. In addition, the cascaded linear systems method is reviewed because it is a very powerful tool for improving the design and assessment of X-ray imaging detector systems.

X-ray Response Characteristic of Zn in the Polycrystalline Cd1-xZnxTe Detector for Digital Radiography

  • Kang, Sang-Sik
    • Transactions on Electrical and Electronic Materials
    • /
    • 제3권2호
    • /
    • pp.28-31
    • /
    • 2002
  • The Cdl-xZnxTe film was fabricated by thermal evaporation for the flat-panel X-ray detector. The stoichimetric ratio and the crystal structure of a polycrystalline Cd$_{1-x}$ Zn$_{x}$Te were investigated by EPMA and XRD, respectively. The leakage current and X-ray sensitivity of the fabricated films were measured to analyze the X-ray response characteristic of Zn in the polycrystalline CdZnTe thin film. The leakage current and the output charge density of Cd$_{0.7}$Zn$_{0.3}$Te thin film were measured to 0.37 nA/cm$^2$ and 260 pc/cm$^2$ at an applied voltage of 2.5 V/${\mu}{\textrm}{m}$, respectively. Experimental results showed that the increase of Zn doping rates in Cd$_{1-x}$ Zn$_{x}$Te detectors reduced the leakage current and improved the signal to noise ratio significantly.

Mercuric iodide 기반의 디지털 X-선 검출기의 특성 연구 (Characterization studies of digital x-ray detector based on mercuric iodide)

  • 조성호;박지군;최장용;석대우;차병열;남상회;이범종
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 추계학술대회 논문집 Vol.16
    • /
    • pp.392-395
    • /
    • 2003
  • For the purpose of digital x-ray imaging, many materials such as $PbI_2$, $HgI_2$, TlBr, CdTe and CdZnTe have been under development for servaral years as direct converter layer. $Hgl_2$ film detector have recently been shown as one of the most promising semiconductor materials to be used as direct converters in x-ray digital radiography. This paper, the $HgI_2$ films are deposited on conductive-coated glass by screen printing, in which $HgI_2$ powder is embedded in a binder and solvent, and the slurry is used to coat the conductive-coated glass. We investigated electrical characteristic of the fabricated $HgI_2$ films. The x-ray response to radiological x-ray generator of 70Kvp using the current integration mode will be reported for screen printing films. These results indicate that $HgI_2$ detectors have high potential as new digital x-ray imaging devices for radiography.

  • PDF

대면적 X-ray 검출기를 위한 분할 구동 시스템 (Seperate Driving System For Large Area X-ray Detector In Radiology)

  • 이동길;박지군;김대환;남상희;안상호;박효덕
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 추계학술대회 논문집 Vol.16
    • /
    • pp.388-391
    • /
    • 2003
  • The properties of these detectors can be controlled by electronics and exposure conditions. Flat-panel detectors for digital diagnostic imaging convert incident x-ray images to charge images. Flat panel detectors gain more interest real time medical x-ray imaging. Active area of flat panel detector is $14{\times}17$ inch. Detector is based on a $2560{\times}3072$ away of photoconductor and TFT pixels. X-ray conversion layer is deposited upper TFT array flat panel with a 500m by thermal deposition technology. Thickness uniformity of this layer is made of thickness control technology(5%) of thermal deposition system. Each $139m{\times}139m$ pixel is made of thin film transistor technology, a storage capacitor and charge collection electrode having geometrical fill factor of 86%. Using the separate driving system of two dimensional mosaic modules for large area, that is able to 4.2 second per frame. Imaging performance is suited for digital radiography imaging substitute by conventional radiography film system..

  • PDF

Application of portable digital radiography for dental investigations of ancient Egyptian mummies during archaeological excavations: Evaluation and discussion of the advantages and limitations of different approaches and projections

  • Seiler, Roger;Eppenberger, Patrick;Ruhli, Frank
    • Imaging Science in Dentistry
    • /
    • 제48권3호
    • /
    • pp.167-176
    • /
    • 2018
  • Purpose: In the age of X-ray computed tomography (CT) and digital volume tomography (DVT), with their outstanding post-processing capabilities, indications for planar radiography for the study of the dentition of ancient Egyptian mummies may easily be overlooked. In this article, the advantages and limitations of different approaches and projections are discussed for planar oral and maxillofacial radiography using portable digital X-ray equipment during archaeological excavations. Furthermore, recommendations are provided regarding projections and sample positioning in this context. Materials and Methods: A total of 55 specimens, including 19 skeletonized mandibles, 14 skeletonized skulls, 18 separate mummified heads, and 4 partially preserved mummies were imaged using portable digital X-ray equipment in the course of archaeological excavations led by the University of Basel in the Valley of the Kings between 2009 and 2012. Images were evaluated by 2 authors with regard to the visibility of diagnostically relevant dental structures using a 4-point grading system(Likert scale). Results: Overall, the visibility of diagnostically relevant dental structures was rated highest by both authors on X-ray images acquired using a dental detector. The tube-shift technique in the lateral projections of mandibular dentition achieved the second-best rating, and lateral projections achieved the third-best rating. Conclusion: Conventional planar digital X-ray imaging, due to its ubiquity, remains an excellent method-and often the only practicable one-for examining the skulls and teeth of ancient Egyptian mummies under field conditions. Radiographic images of excellent diagnostic quality can be obtained, if an appropriate methodology regarding the selected projections and sample placement is followed.

이동형 구내방사선촬영기와 벽걸이 구내방사선촬영기로 촬영한 치근단 방사선촬영에서 환자의 흡수선량과 유효선량 평가 (Absorbed and effective dose for periapical radiography using portable and wall type dental X-ray machines)

  • 한원정
    • 대한치과보철학회지
    • /
    • 제50권3호
    • /
    • pp.184-190
    • /
    • 2012
  • 연구 목적: 이 연구는 상악 전치부와 하악 구치부 치근단 방사선촬영시 이동형 구내방사선촬영기와 벽걸이 구내방사선촬영기로 촬영한 경우에서 환자의 방사선량을 알아보고자 하였다. 연구 재료 및 방법: 방사선량 측정은 선량 측정용 두경부 마네킨의 23부위에 열형광선량계 소자를 위치시키고 해당 치근단 방사선촬영을 하였다. 열형광선량계 판독기로 흡수선량을 구하였고 방사선 조사된 조직의 비율을 곱하여 방사선 가중선량을 구하였다. 국제방사선방호위원회에서 2007년에 공지한 조직 가중계수를 이용하여 각 방사선촬영의 유효선량을 구하였다. 결과: 환자의 흡수선량은 이동형 구내방사선촬영기로 촬영한 상악 전치부와 이동형 및 벽걸이 구내방사선촬영기로 촬영한 하악 구치부 치근단방사선촬영의 경우 하악체에서 가장 높았다. 유효선량은 상악 전치부 치근단 방사선촬영에서는 이동형 촬영기로 촬영한 경우 $4{\mu}Sv$, 벽걸이 촬영기로 촬영한 경우 $2{\mu}Sv$였고 우측 하악 구치부 치근단 방사선촬영에서는 각각 $6{\mu}Sv$, $2{\mu}Sv$였다. 결론: 벽걸이 구내방사선촬영기보다 이동형 구내방사선촬영기로 촬영한 치근단 방사선촬영에서의 유효선량이 더 많기 때문에 술자는 구내방사선촬영기에 따른 방사선 노출 정도를 충분히 인지하고 이를 사용하여야 한다.

Computed Radiography의 영상특성에 관한 연구 (Study of Image Properties for Computed Radiography)

  • 류기현;정재은
    • 대한디지털의료영상학회논문지
    • /
    • 제10권2호
    • /
    • pp.23-31
    • /
    • 2008
  • Computed radiography(CR) has been widely used in the field of diagnostic radiography since digital X-ray image was introduced. The imaging performance of CR system was studied by analyzing the digital image data of the CR images which are the outcomes of the whole imaging system composed of image plate(IP), laser digitizer, analoge-digital convertor, and a given image processing unit. In this study, we used a conventional CR system made by Agfa. From the flat field image of 150$\times$150 image pixels, signal-to-noise ratio(SNR) was calculated. SNR of the CR image increases in proportion to logarithm value of the X-ray exposure irradiated on the IP. SNR is less than about 6 at the exposure below 0.2mR and is more than 10 at the exposure above 0.54mR. In our study, most of images obtained by the smaller exposures less than 2.0mR can not be readable. In general, the minimum value of the SNR ranges from 3 to 5. We obtained modulation transfer function(MTF) by analyzing the bar pattern image which was made under conditions as follows: X-ray tube potential was 55kVp, the IP exposure was 0.54 mR, and the distance between X-ray source to IP was 2m, where bar pattern was located on the IP. MTF is 23% at 2.5lp/mm spatial frequency. Provided that the MTF of noise equivalent modulation is 10%, the CR system has the limiting spatial resolution of 3.2lp/mm. If the image sharpness is evaluated by the spatial frequency where MTF is 50%. the corresponding spatial frequency is 0.5$\sim$0.75lp/mm. MTFA(Modulation Transfer Function Area) is 1.0lp/mm. Compared with the Fuji CR whose MTFA is 1.1lp/mm, Agfa CR in this study shows almost same MTFA performance.

  • PDF