무연솔더 내 마이그레이션 플럭스개발에 관한 연구 (A Study on Development of Flux to Restrict Occurrence of ion Migration in Lead-Free Solder)

  • 유동수;임재훈;우성우
    • 한국신뢰성학회:학술대회논문집
    • /
    • 한국신뢰성학회 2005년도 학술발표대회 논문집
    • /
    • pp.385-392
    • /
    • 2005
  • The restriction of the use of hazardous substances in electrical and electronic equipment legislation mandates the substitution of lead and other hazardous substances in electronics products by July 2006. Due to this legislative pressure, the electronics industry is moving to adoption of lead free solders. In this paper, we investigated a flux to restrict generating electrochemical migration in lead-free solder. The lead-free solders used in this study were Sn-0.7Cu-0.01P and Sn-3.0Ag-0.5Cu. To measure the resistance of electrochemical migration, the dew-cycle test and water drop test were adopted. As the result, now flux having high durable of electrochemical migration was developed.

  • PDF

Computed Radiography의 영상특성에 관한 연구 (Study of Image Properties for Computed Radiography)

  • 류기현;정재은
    • 대한디지털의료영상학회논문지
    • /
    • 제10권2호
    • /
    • pp.23-31
    • /
    • 2008
  • Computed radiography(CR) has been widely used in the field of diagnostic radiography since digital X-ray image was introduced. The imaging performance of CR system was studied by analyzing the digital image data of the CR images which are the outcomes of the whole imaging system composed of image plate(IP), laser digitizer, analoge-digital convertor, and a given image processing unit. In this study, we used a conventional CR system made by Agfa. From the flat field image of 150$\times$150 image pixels, signal-to-noise ratio(SNR) was calculated. SNR of the CR image increases in proportion to logarithm value of the X-ray exposure irradiated on the IP. SNR is less than about 6 at the exposure below 0.2mR and is more than 10 at the exposure above 0.54mR. In our study, most of images obtained by the smaller exposures less than 2.0mR can not be readable. In general, the minimum value of the SNR ranges from 3 to 5. We obtained modulation transfer function(MTF) by analyzing the bar pattern image which was made under conditions as follows: X-ray tube potential was 55kVp, the IP exposure was 0.54 mR, and the distance between X-ray source to IP was 2m, where bar pattern was located on the IP. MTF is 23% at 2.5lp/mm spatial frequency. Provided that the MTF of noise equivalent modulation is 10%, the CR system has the limiting spatial resolution of 3.2lp/mm. If the image sharpness is evaluated by the spatial frequency where MTF is 50%. the corresponding spatial frequency is 0.5$\sim$0.75lp/mm. MTFA(Modulation Transfer Function Area) is 1.0lp/mm. Compared with the Fuji CR whose MTFA is 1.1lp/mm, Agfa CR in this study shows almost same MTFA performance.

  • PDF

A study on the Variable Elimination of the 0-th order Diffraction Using the Fourier Transform in the Digital Holography Microscope System

  • Choi, Kyu-Hwan;Kim, Sung-Kyu
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2009년도 9th International Meeting on Information Display
    • /
    • pp.1357-1360
    • /
    • 2009
  • In this study, the 0-th order diffraction could be efficiently removed with the obtained data for one hologram using the numerical reconstruction method. This method has a reduced data acquisition and processing time compared with the existing method wherein the data for two or more phase holograms are obtained for regeneration, and efficiently eliminates the 0-th order diffraction.

  • PDF

Three-dimensional comparison of 2 digital models obtained from cone-beam computed tomographic scans of polyvinyl siloxane impressions and plaster models

  • Park, Jin-Yi;Kim, Dasomi;Han, Sang-Sun;Yu, Hyung-Seog;Cha, Jung-Yul
    • Imaging Science in Dentistry
    • /
    • 제49권4호
    • /
    • pp.257-263
    • /
    • 2019
  • Purpose: This study was performed to evaluate the dimensional accuracy of digital dental models constructed from cone-beam computed tomographic (CBCT) scans of polyvinyl siloxane (PVS) impressions and cast scan models. Materials and Methods: A pair of PVS impressions was obtained from 20 subjects and scanned using CBCT (resolution, 0.1 mm). A cast scan model was constructed by scanning the gypsum model using a model scanner. After reconstruction of the digital models, the mesio-distal width of each tooth, inter-canine width, and inter-molar width were measured, and the Bolton ratios were calculated and compared. The 2 models were superimposed and the difference between the models was measured using 3-dimensional analysis. Results: The range of mean error between the cast scan model and the CBCT scan model was -0.15 mm to 0.13 mm in the mesio-distal width of the teeth and 0.03 mm to 0.42 mm in the width analysis. The differences in the Bolton ratios between the cast scan models and CBCT scan models were 0.87 (anterior ratio) and 0.72 (overall ratio), with no significant difference (P>0.05). The mean maxillary and mandibular difference when the cast scan model and the CBCT scan model were superimposed was 53 ㎛. Conclusion: There was no statistically significant difference in most of the measurements. The maximum tooth size difference was 0.15mm, and the average difference in model overlap was 53 ㎛. Digital models produced by scanning impressions at a high resolution using CBCT can be used in clinical practice.

중첩 불일치 평가기준으로서의 계수공제영상의 계조도 표준편차 연구 (The Study of Standard Deviation of Gray Scale Histogram in Digital Subtraction Radiography as a Test Parameter for SuperimpoSition Error)

  • 조봉혜
    • 치과방사선
    • /
    • 제29권2호
    • /
    • pp.417-422
    • /
    • 1999
  • Purpose : The aim of this study was to assess the validity of standard deviation of gray scale histogram in digital subtraction radiography as a test parameter for superimposition error. Materials and Methods : Twenty periapical radiographs were used as baseline images and they were copied to exclude the influence of exposure geomety and contrast differences. These subsequent images were linearly displaced by 0.1-0.5 mm in the x-. y- and xy-directions, rotated by 0.5-3° and distorted by angular contraction of 1-5° in x- and y-axis before subtraction. The standard deviations of gray levels in the subtraction images were obtained and paired t-tests were performed. Pearson correlation coefficients(r) were calculated between the standard deviations and the superimposition errors. Results : Linear displacement showed high correlation coefficients of 0.997, 0.997 and 0.995 in x-. y- and xy-axis respectively. Statistically significant different standard deviation existed among all linearly displaced groups(p<0.05). Distortion showed relatively low correlation coefficients of 0.982 and 0.959 in x- and y-axis. The standard deviations between the two distortion groups were statistically significant different(p<0.05). Conclusion : Standard deviation of gray level distribution in digital subtraction images is satisfactory but not perfect similarity measure to assess the superimposition errors.

  • PDF

디지털 방사선투과영상의 정밀성 평가에 관한 연구 (An Assessment of the Accuracy for Digital Radiography Image)

  • 박상기;안연식;길두송
    • Journal of Welding and Joining
    • /
    • 제27권2호
    • /
    • pp.51-56
    • /
    • 2009
  • Film based radiography imaging technique has been applied to the non-destructive test in medical, aircraft, and power industries contributing to the development of the industries. However, the complex process for imaging and analysis has increasingly demanded the reformation of the radiography test. A digital radiography imaging technologies has been com out from the demand. This study was mainly focused on the assessment on the accuracy for the each image from digital radiography test and film radiography test was proven to crate a better image in sensitivity than film radiography test. In the IQI(Image quality indicator) transmission test, one or two more line can be seen in digital image than in film image. When applying to the boiler tube weld, film image is detectable to the 1.0mm depth flaw; and digital image to the 0.5mm depth flaw. As a result of this study, digital radiography technology is determined to enhance the image quality, compared to film radiography technologies

The efficacy of the reverse contrast mode in digital radiography for the detection of proximal dentinal caries

  • Miri, Shimasadat;Mehralizadeh, Sandra;Sadri, Donya;Motamedi, Mahmood Reza Kalantar;Soltani, Parisa
    • Imaging Science in Dentistry
    • /
    • 제45권3호
    • /
    • pp.141-145
    • /
    • 2015
  • Purpose: This study evaluated the diagnostic accuracy of the reverse contrast mode in intraoral digital radiography for the detection of proximal dentinal caries, in comparison with the original digital radiographs. Materials and Methods: Eighty extracted premolars with no clinically apparent caries were selected, and digital radiographs of them were taken separately in standard conditions. Four observers examined the original radiographs and the same radiographs in the reverse contrast mode with the goal of identifying proximal dentinal caries. Microscopic sections $5{\mu}m$ in thickness were prepared from the teeth in the mesiodistal direction. Four slides prepared from each sample used as the diagnostic gold standard. The data were analyzed using SPSS (${\alpha}=0.05$). Results: Our results showed that the original radiographs in order to identify proximal dentinal caries had the following values for sensitivity, specificity, positive predictive value, negative predictive value, and accuracy, respectively: 72.5%, 90%, 87.2%, 76.5%, and 80.9%. For the reverse contrast mode, however, the corresponding values were 63.1%, 89.4%, 87.1%, 73.5%, and 78.8%, respectively. The sensitivity of original digital radiograph for detecting proximal dentinal caries was significantly higher than that of reverse contrast mode (p<0.05). However, no statistically significant differences were found regarding specificity, positive predictive value, negative predictive value, or accuracy (p>0.05). Conclusion: The sensitivity of the original digital radiograph for detecting proximal dentinal caries was significantly higher than that of the reversed contrast images. However, no statistically significant differences were found between these techniques regarding specificity, positive predictive value, negative predictive value, or accuracy.

Validity of palatal superimposition of 3-dimensional digital models in cases treated with rapid maxillary expansion and maxillary protraction headgear

  • Choi, Jin-Il;Cha, Bong-Kuen;Jost-Brinkmann, Paul-Georg;Choi, Dong-Soon;Jang, In-San
    • 대한치과교정학회지
    • /
    • 제42권5호
    • /
    • pp.235-241
    • /
    • 2012
  • Objective: The purpose of this study was to evaluate the validity of the 3-dimensional (3D) superimposition method of digital models in patients who received treatment with rapid maxillary expansion (RME) and maxillary protraction headgear. Methods: The material consisted of pre- and post-treatment maxillary dental casts and lateral cephalograms of 30 patients, who underwent RME and maxillary protraction headgear treatment. Digital models were superimposed using the palate as a reference area. The movement of the maxillary central incisor and the first molar was measured on superimposed cephalograms and 3D digital models. To determine whether any difference existed between the 2 measuring techniques, intra-class correlation (ICC) and Bland-Altman plots were analyzed. Results: The measurements on the 3D digital models and cephalograms showed a very high correlation in the antero-posterior direction (ICC, 0.956 for central incisor and 0.941 for first molar) and a moderate correlation in the vertical direction (ICC, 0.748 for central incisor and 0.717 for first molar). Conclusions: The 3D model superimposition method using the palate as a reference area is as clinically reliable for assessing antero-posterior tooth movement as cephalometric superimposition, even in cases treated with orthopedic appliances, such as RME and maxillary protraction headgear.

디지털경사계를 사용한 체간재위치오류 검사의 신뢰도 분석 (Analysis of Intrarater and Interrater Reliability of Trunk Repositioning Error Test using a Portable Digital Inclinometer)

  • 장우남;이경보;염준우;황병용
    • The Journal of Korean Physical Therapy
    • /
    • 제25권4호
    • /
    • pp.210-216
    • /
    • 2013
  • Purpose: A cost effective tool for the clinical measurement of trunk reposition sense is clearly needed. This study was to analyze intrarater and interrater Reliability of trunk repositioning error (TRE) test which assesses trunk position sense using a portable digital inclinometer. Methods: Twenty four normal healthy subjects were recruited. TRE was measured using a portable digital inclinometer. A digital inclinometer (Acumar-ACU360; Lafayetter Instrument) with precision to $1^{\circ}$ was placed on skin over the spinous process from first to second thoracic vertebra (T1-T2) and secured with double-sided tape. TRE test during sitting forward and lateral flexion movement was assessed. When they reached a point approximately 50% of full trunk flexion range, the examiner instructed the subjects to stop and told them. This was the target position that they should try to reproduce exactly. Each subject performed six trials. Results: ICC (2,1) for intrarater reliability (with-day and between-day) of TRE test in sagittal and frontal plane of movement was 0.75 and 0.78 (excellent reliability). Interrater reliability was 0.66 in sagittal and 0.64, frontal plane (fair to good reliability). However, there were poor correlations between an average of TRE test in sagittal and frontal plane. Conclusion: TRE test using a portable digital inclinometer demonstrated good to excellent reliability. The device may be a cost effective clinical measurement for trunk reposition sense measurement.

아날로그 - 디지털 스위칭 혼합형 저 리플- 고 효율 Li-Ion 배터리 충전기 (Analog-Digital Switching Mixed Mode Low Ripple - High Efficiency Li-Ion Battery Charger)

  • 정상화;우영진;김남인;조규형
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 D
    • /
    • pp.2531-2533
    • /
    • 2001
  • This paper describes a low noise and high efficiency analog-digital switching mixed mode battery charger for production facilities of Li-Ion batteries. The requirements for battery chargers for production facilities are very strict. The accuracy of output voltage and output current should be below 0.1% with very low ripple current. Therefore analog type linear regulators are widely used for battery charger in spite of their inefficiency and bulkiness. We combined linear regulator as a voltage source with digital switching converter as a dependent current source. Low current ripple and high accuracy are obtained by linear regulator while high efficiency is achieved by digital switching converter. Experimental results show that proposed method has 0.1% ripple and 90% efficiency at an output current of 1A for a battery voltage of 4V.

  • PDF