• 제목/요약/키워드: diffuse reflectance

검색결과 129건 처리시간 0.024초

Determination of Toner Content by Diffuse Reflectance for Office Paper Recycling Studies

  • Oki, Tatsuya;Owada, Shuji;Yotsumoto, Hiroki;Tanuma, Hirokazu
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 The 6th International Symposium of East Asian Resources Recycling Technology
    • /
    • pp.111-116
    • /
    • 2001
  • Waste office paper, photocopied or laser printed, has recently increased along with office automatization. In waste office paper, toner ink is used as the printing medium in place of conventional oil ink. Since toner ink cannot be saponificated by alkali and be decolored by bleaching, different from the case of oil ink, toner remains on regenerated paper as black specks. Although cascade recycling of waste office paper is compelled at present, the demand for low-grade paper is limited. From such circumstances, a new separation process for waste office paper is demanded to achieve parallel recycling. At the first stage of separation studies, the sharpness of separation is evaluated using small separators to obtain fundamental data. In a lab-scale separator, the sample amount of one feed is generally a few grams. However, the sample amount used for brightness, ERIC, and image analysis that are generally used to evaluate the efficiency of deinking are not small for lab-scale tests of these analyses. This paper describes an investigation of a sheet preparation method by a small amount of sample under 0.5g and compares the precision of toner content determination of spectroscopic analysis and image analysis from the viewpoint of separation evaluation. The easiness and convenience of the operation using only general-purpose equipments has also been set as a principle purpose. From the viewpoint of an analysis that yields high precision with a small amount of sample in short time, the method calculating the absorption coefficient from diffuse reflectance in the visible region is the most rational method in this study.

  • PDF

마이크로에멀젼 방법에 의해 제조된 Ag/TiO2의 Reactive Orange 16 제거에 관한 연구 (Removal of Reactive Orange 16 by the Ag/TiO2 Composite Produced from Micro-emulsion Method)

  • 이시진
    • 한국지반환경공학회 논문집
    • /
    • 제20권11호
    • /
    • pp.5-10
    • /
    • 2019
  • 본 연구에서는 장파장에서 감응하는 광촉매를 개발하기 위하여 상용화된 $TiO_2$에 Ag를 도핑하여 제조하였으며 광촉매 효율을 향상시키기 위하여 귀금속의 분산을 증대시키는 마이크로에멀젼 방법을 이용하였다. 제조된 $Ag/TiO_2$의 물리적 특성은 SEM(Scanning Electron Microscopy), FE-TEM(Field Emission Transmission Electron Microscopy), DRS(Diffuse Reflectance Spectroscopy)를 통해 분석하였다. RO 16(Reactive Orange 16)에 대한 광촉매의 제거 효율은 25ppm의 RO 16을 대상으로 UV-A 영역(365nm)에서 수행하였다. Ag의 도핑방법에 의한 광촉매 효율을 비교하기 위해 볼밀링 및 딥코팅 방법으로 제조하여 광촉매 효율을 분석하였으며 광촉매 효율에 대한 Ag 및 계면활성제 함량에 대한 최적화를 진행하였다. 도핑방법에 따른 RO 16 제거효율 분석 결과, 마이크로에멀젼 방법으로 제조한 $Ag/TiO_2$의 RO 16 제거효율이 가장 높았으며 Ag 함량 2wt%, 계면활성제 0.5g에서 가장 높은 제거효율을 보였다.

광반사를 이용한 한국 논 토양 특성센서를 위한 샘플링과 캘리브레이션 요구조건 (Sampling and Calibration Requirements for Optical Reflectance Soil Property Sensors for Korean Paddy Soils)

  • 이규승;이동훈;정인규;정선옥
    • Journal of Biosystems Engineering
    • /
    • 제33권4호
    • /
    • pp.260-268
    • /
    • 2008
  • Optical diffuse reflectance sensing has potential for rapid and reliable on-site estimation of soil properties. For good results, proper calibration to measured soil properties is required. One issue is whether it is necessary to develop calibrations using samples from the specific area or areas (e.g., field, soil series) in which the sensor will be applied, or whether a general "factory" calibration is sufficient. A further question is if specific calibration is required, how many sample points are needed. In this study, these issues were addressed using data from 42 paddy fields representing 14 distinct soil series accounting for 74% of the total Korean paddy field area. Partial least squares (PLS) regression was used to develop calibrations between soil properties and reflectance spectra. Model evaluation was based on coefficient of determination ($R^2$) root mean square error of prediction (RMSEP), and RPD, the ratio of standard deviation to RMSEP. When sample data from a soil series were included in the calibration stage (full information calibration), RPD values of prediction models were increased by 0.03 to 3.32, compared with results from calibration models not including data from the test soil series (calibration without site-specific information). Higher $R^2$ values were also obtained in most cases. Including some samples from the test soil series (hybrid calibration) generally increased RPD rapidly up to a certain number of sample points. A large portion of the potential improvement could be obtained by adding about 8 to 22 points, depending on the soil properties to be estimated, where the numbers were 10 to 18 for pH, 18-22 for EC, and 8 to 22 for total C. These results provide guidance on sampling and calibration requirements for NIR soil property estimation.

Near Infrared Spectroscopy for Measuring Soil Properties

  • Ryu, Kwan-Shig;Kim, Bok-Jin;Park, Woo-Churl;Cho, Rae-Kwang
    • Near Infrared Analysis
    • /
    • 제1권1호
    • /
    • pp.37-41
    • /
    • 2000
  • The purpose of this research was to develop a the reflection technique with near infrared (NIR) radiation for estimating soil components. NIR reflectance was scanned at 2nm intervals from 1100 to 2500nm with an InfraAlyzer 500 (Bran & Luebbe Co.). Over 400 soil sample from fields of different crops and land-use over Youngnam and Honam regions were used to obtain mean diffuse reflection of the soil for the calibration and validation of the calibration set in estimating moisture, organic matter (OM) and total nitrogen (T-N) of the soils. Multiple linear regression (MLR) was used to evaluate the correlation of NIR spectroscopy method. Reflection pattern of NIR spectra for finely sized sample (<0.5mm) and coarsely sized soil(<2mm) did not show much difference. The results showed that NIR spectroscopy and coarsely sized soil (<2mm) did not show much difference. The results showed that NIR spectroscopy could be used as a routine soil testing method in estimating OM, moisture, T-N in soil samples simultaneously.

Effect of particle size and scanning cup type for near infrared reflection on the soil property measurement

  • Ryu, Kwan-Shig;Cho, Rae-Kwang;Park, Woo-Churl;Kim, Bok-Jin
    • Near Infrared Analysis
    • /
    • 제1권2호
    • /
    • pp.35-39
    • /
    • 2000
  • The purpose of this research was to find out suitable soil sample preparation and sample holding tools for NIR reflection radiation for estimating soil components. NIR reflectance was scanned at 2nm intervals from 1,100 to 2,500nm with an InfraAlyzer 500(Bran+Luebbe Co.). Coarse(2.0mm) and fine(0.5mm) soil sample and various sample holding tools were used to obtain mean diffuse reflection of the soil for the calibration and validation of the calibration set in estimating moisture, organic matter and total nitrogen of the soils. Multiple linear regression was used to obtain the best correlation of NIR spectroscopy method. Correlation of NIR spectroscopy method. Correlation of NIR spectra for finely and coarsely sized soil did not show much difference. The standard errors of prediction(SE) using different types of sample holding tools for organic matter, total nitrogen and soil moisture were better than 0.765, 0.041 and 0.63% respectively. From the results it can be concluded that NIR spectroscopy with flow type cell could be used as a fast routine testing method in quantitative determination of organic matter, total nitrogen and soil moisture.

Synthesis of Monodispersed and Spherical $SiO_2-coated Fe_2O_3$ Nanoparticle

  • 한양수;윤선미;김동국
    • Bulletin of the Korean Chemical Society
    • /
    • 제21권12호
    • /
    • pp.1193-1198
    • /
    • 2000
  • The preparation of nanocrystalline hematite, ${\alpha}-Fe_2O_3$, paricles and their surface coating with silica layers are described. The hematite particles with the size of 30~60 nm are firstly prepared by thermal decomposition of trinuclear acetate-hydroxo iron (III) nitrate complex, $[Fe_3$(OCOCH_3)_7$OH${\cdot}$2H_2O]NO_3$, at $400^{\circ}C$. Subsequently the hematite surfaces are coated with siliva layers by a controlled hydrolysis and condensation reaction of TEOS with varying the TEOS concentration and pH. Monodispersed and spherical $SiO_2-coatedFe_2O_3$ particles with the average particle diameter of ~90 nm and extremely narrow size distribution can be obtained at the pH of 11 and the TEOS concentration of 0.68M, which are found to be the optimum conditions in the present study in achieving the homogeneous deposition of silica layers on hematite surfaces. Diffuse reflectance UV-Vis spectra reveal that the characteristic optical reflectance of ${\alpha}-Fe_2O_3$ particles is preserved almost constant even after coating the surfaces, suggesting that the $SiO_2$ layers can be regarded as protecting layers without degrading the optical properties of hematite particles.

Sorption and Separation of Thiocyanate Gold and Silver Complexes and Determination of Gold by Diffuse Reflectance Spectroscopy

  • Danilenko, N.V.;Kononova, O.N.;Kachin, S.V.;Kholmogorov, A.G.;Dmitrieva, Zh.V.;Plotnikova, E.A.
    • Bulletin of the Korean Chemical Society
    • /
    • 제25권7호
    • /
    • pp.1019-1024
    • /
    • 2004
  • The present paper is focused on simultaneous sorption concentration of gold (III) and silver (I) from thiocyanate solutions using high-selective anion exchanger AN-25 and subsequent separation of these ions at various concentrations of thiocarbamide (eluent). As a result, silver (I) ions are completely eluted from AN-25 and gold (III) ions remain in the resin phase and can be determined directly in the solid phase by diffuse reflection spectroscopy. It is proposed to use the sorption-spectroscopic method for Au(III) determination in aqueous solutions. The calibration curve is linear in the concentration range of 1-19 mg/L (sample volume is 10.0 mL) and the detection limit is 0.05 ${\mu}g/mL$. The presence of Cu(II), Co(II), Fe(II) do not hinder this determination. Au(III) was determined in industrial solutions.

ESTIMATION OF SUGAR AND REDUCING SUGAR IN MOLASSES USING NEAR INFRARED REFLECTANCE SPECTROSCOPY

  • Mehrotra, Ranjana;Gupta, Alka;Tewari, Jagdish;Varma, S.P.
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.1258-1258
    • /
    • 2001
  • Estimation of sugar and reducing sugar content in molasses is very important task in sugar refineries. Conventional methods of determination of sugar content in molasses samples are highly time consuming and employ hazardous chemicals. Due to the physical properties of molasses, probability of error in conventional analytical techniques is high. These methods have proven to be inefficient for a process control in any sugar industry. Hence development of a rapid, inexpensive, physical and also accurate method for sugar determination in molasses will be highly useful. Near Infrared spectroscopy is being widely used worldwide as an analytical technique in food industry. The technique offers the advantage of being non-destructive and rapid. The present paper highlights the potential of near infrared reflectance spectroscopy as a rapid and automated analytical technique for determination of sugar and reducing sugar content in molasses. A number of molasses samples were collected during and after the sugar season from Havana Sugar Industry, Havana. The samples were chosen so as to obtain a wide range of concentration of sugar and reducing sugars. This was done in order to achieve a good calibration curve with widely spread data points. These samples were scanned in the region of 1100 - 2500 nm in diffuse reflectance mode. An indigenous ELICO NIR spectrophotometer, modified according to the requirements of sugar industry was used for this purpose. Each sample was also analyzed simultaneously by standard chemical methods. Chemical values were taken as reference for near infrared analysis. In order to obtain the most accurate calibration for the set of samples, various mathematical treatments were employed. Partial Least Square method was found to be most suitable for the analysis. A comparison is made between the actual values (chemical values) and the predicted values (NIR values). The actual values agree very well with the predicted values showing the accuracy of the technique. The validity of the technique is checked by predicting the concentration of sugar in unknown molasses samples using the calibration curve. The present investigation assesses the feasibility of the technique for on-line monitoring of sugars present in molasses in sugar industries.

  • PDF

Synthesis of CdSe-TiO2 Photocatalyst and Their Enhanced Photocatalytic Activities under UV and Visible Light

  • Lim, Chang-Sung;Chen, Ming-Liang;Oh, Won-Chun
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권5호
    • /
    • pp.1657-1661
    • /
    • 2011
  • In this study, CdSe-$TiO_2$ photocatalyst were synthesized by a facile solvothermal method and characterized by X-ray diffraction (XRD), Scanning electron microscopy (SEM) with energy dispersive X-ray (EDX) analysis and UV-vis diffuse reflectance spectrophotometer. The photocatalytic activity was investigated by degrading methylene blue (MB) in aqueous solution under irradiation of UV light as well as visible light. The absorbance of degraded MB solution was determined by UV-vis spectrophotometer. The results revealed that the CdSe-$TiO_2$ photocatalyst exhibited much higher photocatalytic activity than $TiO_2$ both under irradiation of UV light as well as visible light.

Effect of Various Supports on the Physico-chemical Properties of V-Sb Oxides in the Oxidative Dehydrogenation of Isobutane

  • Shamilov, N.T.;Vislovskiy, V.P.
    • 대한화학회지
    • /
    • 제55권5호
    • /
    • pp.812-818
    • /
    • 2011
  • [ $V_{0.9}Sb_{0.1}O_x$ ]systems, bulk and deposited on different supports (five types of ${\gamma}$-aluminas, ${\alpha}$-alumina, silica-alumina, silica gel, magnesium oxide), have been tested in the oxidative dehydrogenation (ODH) of iso-butane. This statement is derived from the data obtained by a set of characterisation techniques(specific surface area measurements, X-ray diffraction, X-ray photoelectron spectroscopy, laser Raman spectroscopy, in situ differential scanning calorimetry and in situ diffuse reflectance-absorption infrared Fourier transform spectroscopy).