• Title/Summary/Keyword: diffuse

Search Result 2,360, Processing Time 0.029 seconds

Numerical analysis for supercavitating flows around axisymmetric cavitators

  • Kwack, Young Kyun;Ko, Sung Ho
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.5 no.3
    • /
    • pp.325-332
    • /
    • 2013
  • Diffuse interface model for numerical analysis was used to compute supercavitating flows around various cavitators. The ambient pressures of 2 atm permitted cavitation studies in a range of cavitation number, ${\sigma}=0.1$ to 1.0 on selected conical and disk-headed cavitors. The computed results were compared with relation by Reichardt. Drag coefficient obtained from pressure forces acting on the cavitator also compared well with those obtained from analytical relations.

A Generalized Finite Difference Method for Crack Analysis (일반화된 유한차분법을 이용한 균열해석)

  • Yoon, Young-Cheol;Kim, Dong-Jo;Lee, Sang-Ho
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2007.04a
    • /
    • pp.501-506
    • /
    • 2007
  • A generalized finite difference method for solving solid mechanics problems such as elasticity and crack problems is presented. The method is constructed in framework of Taylor polynomial based on the Moving Least Squares method and collocation scheme based on the diffuse derivative approximation. The governing equations are discretized into the difference equations and the nodal solutions are obtained by solving the system of equations. Numerical examples successfully demonstrate the robustness and efficiency of the proposed method.

  • PDF

Collison Tumor of Adenocarcinoma and Diffuse Large B-Cell Lymphoma in the Rectum: a Case Report and Literature Review

  • Kim, See Hyung
    • Investigative Magnetic Resonance Imaging
    • /
    • v.23 no.4
    • /
    • pp.374-380
    • /
    • 2019
  • Collision tumor is a synchronous neoplasm wherein two histologically distinct tumors co-exist within the same anastomosis site. Collision tumor can occur in any organ, but the incidence is markedly rare. Additionally, preoperative diagnosis can be challenging to the radiologist. Herein, we report an age 60 male with collision tumor of rectal adenocarcinoma and diffuse large B-cell lymphoma, presented as a semi-annular wall thickening and bulky exophytic mass on MR imaging.

Preprocessing and Calibration of Optical Diffuse Reflectance Signal for Estimation of Soil Physical and Chemical Properties in the Central USA (미국 중부 토양의 이화학적 특성 추정을 위한 광 확산 반사 신호 전처리 및 캘리브레이션)

  • La, Woo-Jung;Sudduth, Kenneth A.;Chung, Sun-Ok;Kim, Hak-Jin
    • Journal of Biosystems Engineering
    • /
    • v.33 no.6
    • /
    • pp.430-437
    • /
    • 2008
  • Optical diffuse reflectance sensing in visible and near-infrared wavelength ranges is one approach to rapidly quantify soil properties for site-specific management. The objectives of this study were to investigate effects of preprocessing of reflectance data and determine the accuracy of the reflectance approach for estimating physical and chemical properties of selected Missouri and Illinois, USA surface soils encompassing a wide range of soil types and textures. Diffuse reflectance spectra of air-dried, sieved samples were obtained in the laboratory. Calibrations relating spectra to soil properties determined by standard methods were developed using partial least squares (PLS) regression. The best data preprocessing, consisting of absorbance transformation and mean centering, reduced estimation errors by up to 20% compared to raw reflectance data. Good estimates ($R^2=0.83$ to 0.92) were obtained using spectral data for soil texture fractions, organic matter, and CEC. Estimates of pH, P, and K were not good ($R^2$ < 0.7), and other approaches to estimating these soil chemical properties should be investigated. Overall, the ability of diffuse reflectance spectroscopy to accurately estimate multiple soil properties across a wide range of soils makes it a good candidate technology for providing at least a portion of the data needed in site-specific management of agriculture.

Primary T-cell Lymphoma of the Lung Presenting with Bilateral Hilar Lymphadenopathies and Diffuse Pulmonary Infiltration (폐문 임파절 종대를 동반한 양측성 미만성 폐침윤)

  • Kim, Bo Kyoung;Kim, Chi Hong;Moon, Hwa Sik;Song, Jeong Sup;Park, Sung Hak
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.1
    • /
    • pp.203-208
    • /
    • 1997
  • Non-Hodgkin's lymphoma arising in lung comprises 0.5% of primary lung tumor and 3% of extranodal lymphoma. The most common radiographic abnormalities of pulmonary lymphoma include pulmonary nodule and consolidation, but hilar lymphadenopathy is rarely observed Recently we experienced primary pulmonary T-cell lymphoma presenting with bilateral hilar lymphadenopathies and diffuse pulmonary infiltration A 39-year-old man was admitted to the hospital because of fever, cough, and severe dyspnea. Chest PA obtained on admission revealed bilateral hilar lymphadenopathies and diffuse bilateral pulmonary infiltration. The diagnosis of sarcoidosis was strongly suggested and empirical treatment with corticosteroids resulted in dramatic clinical and radiological improvement for a short time. Eventually, CT-guided lung biopsy was performed and the specimen disclosed primary pulmonary Non-Hodgkin's lymphoma of T-cell origin, diffuse small lymphocytic with focal plasmacytoid differentiation.

  • PDF

Implementation of Multi-channel Concurrent Detection Homodyne Frequency-domain Diffuse Optical Imaging System (다채널 동시측정을 적용한 호모다인 주파수영역 확산 광 이미징 시스템의 구현)

  • Jun, Young Sik;Baek, Woon Sik
    • Korean Journal of Optics and Photonics
    • /
    • v.23 no.1
    • /
    • pp.23-31
    • /
    • 2012
  • In this paper, we developed a frequency-domain diffuse optical imaging (DOI) system for imaging non-invasively using near-infrared (NIR) light sources and detectors. 70-MHz modulation and a homodyne scheme were adopted. By calibration of the coupling coefficients, concurrent detection measurements by 4 detector sets were optimized. We presented experimental reconstruction images of absorption and scattering coefficients in a liquid phantom, located an anomaly in the phantom and determined its optical properties. The images by the multi-channel concurrent detection were improved over the results by single-channel sequential detection. Tomographic slices of absorption and scattering coefficients in the phantom with an anomaly were also presented.

Analysis of Electronic Endoscopic Image of Intramucosal Gastric Carinoma by Using Homoglobin Index (혈색소지수를 이용한 점막내 위암의 전자내시경 영상 분석)

  • Kim Gwang-Ha;Lim Eun-Kyung;Kim Gwang-Baek
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2005.11a
    • /
    • pp.535-541
    • /
    • 2005
  • It has been suggested that the endoscopic color of intramucosal gastric carcinoma is correlated with mucosal vascularity within the carcinomatous tissue. The development of electronic endoscopy has made it possible to quantitatively measure the mucosal hemoglobin volume, using a hemoglobin index. The aim of this study was to make a software program to calculate the hemoglobin index (IHb) and then investigate whether the mucosal IHb determined from the electronic endoscopic data is a useful marker for evaluating the color of intramucosal gastric carcinoma, in particular with regard to its value for discriminating between the histologic type. The mean values of IHb for the carcinoma (IHb-C) and the mean values of IHb for the surrounding non-cancerous mucosa ( IHb-N) were calculated in 75 intestinal-type and 34 diffuse-type gastric carcinomas. Then, we analyzed the ratio of the IHb-C to IHb-N. The mean IHb-C/IHb-N ratio in the intestinal-type carcinoma group was higher than that in the diffuse-type carcinoma group ($1.28{\pm}0.19$ vs. $0.81{\pm}0.18$, respectively, p<0.001). When the cut-off point of the C/N ratio was set at 1.00, the accuracy rate, the sensitivity, the specificity, and the positive and negative predictive values of a C/N ratio below 1.00 for the differential diagnosis of diffuse-type carcinoma from intestinal-type carcinoma were $94.5\%$, $94.1\%$, $94.7\%$, $88.9\%$ and $97.3\%$, respectively. IHb is useful for quantitative measurement of the endoscopic color in intramucosal gastric carcinoma and the IHb-C/IHb-N ratio would be helpful in distinguishing diffuse-type carcinoma from intestinal -type carcinoma.

  • PDF

MODELING OF THE ZODIACAL LIGHT FOR THE AKARI MID-IR ALL-SKY DIFFUSE MAPS

  • Kondo, Toru;Ishihara, Daisuke;Kaneda, Hidehiro;Oyabu, Shinki;Amatsutsu, Tomoya;Nakamichi, Keichiro;Sano, Hidetoshi;Ootsubo, Takafumi;Onaka, Takashi
    • Publications of The Korean Astronomical Society
    • /
    • v.32 no.1
    • /
    • pp.59-61
    • /
    • 2017
  • The AKARI 9 and 18 µm diffuse maps reveal the all-sky distribution of the interstellar medium with relatively high spatial resolution of ~6". The zodiacal light is a dominant foreground component in the mid-infrared. Thus, removal of the zodiacal light is a critical issue to study low surface brightness Galactic diffuse emission. We carried out modeling of the zodiacal light based on the Kelsall model which is constructed from the COBE data. In the previous study, only a time-varying component of the zodiacal light brightness was used for determination of the model parameters. However, there remains a residual component of the zodiacal light around the ecliptic plane even after removal with the model. Therefore, instead of using a time-varying component, we use the absolute brightness of the zodiacal light and we find that the new model can better remove the residual component. As a result, the best-fit model parameters are changed from those in the previous study. We discuss the properties of the zodiacal light based on our new result.

An Approximation Technique for Real-time Rendering of Phong Reflection Model with Image-based Lighting (영상 기반 조명을 적용한 퐁 반사 모델의 실시간 렌더링을위한 근사 기법)

  • Jeong, Taehong;Shin, Hyun Joon
    • Journal of the Korea Computer Graphics Society
    • /
    • v.20 no.1
    • /
    • pp.13-19
    • /
    • 2014
  • In this paper, we introduce a real-time method to render a 3D scene using image-based lighting. Previous approaches for image-based lighting focused on diffuse reflection and mirror-like specular reflection. In this paper, we provide a simple preprocessing approach to efficiently approximate Phong reflection model, which has been used for computer graphics applications for several decades. For diffuse reflection, we generate a texture map for diffuse reflection by integrating the source image in preprocessing step, similarly to the previous approaches. We adopt the similar idea to produce a set of specular reflection maps for various material shininess. By doing this, we can render a dynamic scene without high computational complexity or numerous texture map access.