• Title/Summary/Keyword: difference signal

Search Result 1,756, Processing Time 0.028 seconds

Estimation Technique of Time Difference of Acoustic Signal by phase delay in Underwater Environments (수중 환경에서의 위상 지연을 이용한 음향 신호의 시간 차이 추정 기법)

  • Lee, Young-Pil;Moon, Yong-Seon;Ko, Nak-Yong;Choi, Hyun-Taek;Lee, Jeong-Gu;Bae, Young-Chul
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.11 no.4
    • /
    • pp.365-372
    • /
    • 2016
  • Recently, UWAC(: UnderWater Acoustic Communication) has been studied by many scholars and researchers. There are several method to estimate the time-difference between the two signals such estimating as the arrival time of the first non-background segment in both signals and calculate the temporal difference, calculating the cross-correlation between the two signal to infer the time-lagged, and estimating the phase delay to infer the time difference. In this paper, we present estimating method by the phase delay to infer the time difference in two signals.

A Method for Estimating an Instantaneous Phasor Based on a Modified Notch Filter

  • Nam Soon-Ryul;Sohn Jin-Man;Kang Sang-Hee;Park Jong-Keun
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.3
    • /
    • pp.279-286
    • /
    • 2006
  • A method for estimating the instantaneous phasor of a fault current signal is proposed for high-speed distance protection that is immune to a DC-offset. The method uses a modified notch filter in order to eliminate the power frequency component from the fault current signal. Since the output of the modified notch filter is the delayed DC-offset, delay compensation results in the same waveform as the original DC-offset. Subtracting the obtained DC-offset from the fault current signal yields a sinusoidal waveform, which becomes the real part of the instantaneous phasor. The imaginary part of the instantaneous phasor is based on the first difference of the fault current signal. Since a DC-offset also appears in the first difference, the DC-offset is removed trom the first difference using the results of the delay compensation. The performance of the proposed method was evaluated for a-phase to ground faults on a 345kV 100km overhead transmission line. The Electromagnetic Transient Program was utilized to generate fault current signals for different fault locations and fault inception angles. The performance evaluation showed that the proposed method can estimate the instantaneous phasor of a fault current signal with high speed and high accuracy.

A Study on a New Pre-emphasis Method Using the Short-Term Energy Difference of Speech Signal (음성 신호의 다구간 에너지 차를 이용한 새로운 프리엠퍼시스 방법에 관한 연구)

  • Kim, Dong-Jun;Kim, Ju-Lee
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.50 no.12
    • /
    • pp.590-596
    • /
    • 2001
  • The pre-emphasis is an essential process for speech signal processing. Widely used two methods are the typical method using a fixed value near unity and te optimal method using the autocorrelation ratio of the signal. This study proposes a new pre-emphasis method using the short-term energy difference of speech signal, which can effectively compensate the glottal source characteristics and lip radiation characteristics. Using the proposed pre-emphasis, speech analysis, such as spectrum estimation, formant detection, is performed and the results are compared with those of the conventional two pre-emphasis methods. The speech analysis with 5 single vowels showed that the proposed method enhanced the spectral shapes and gave nearly constant formant frequencies and could escape the overlapping of adjacent two formants. comparison with FFT spectra had verified the above results and showed the accuracy of the proposed method. The computational complexity of the proposed method reduced to about 50% of the optimal method.

  • PDF

An Accurate Direction Finding Technology Using a Phase Comparison and Time Difference of Arrival (위상비교와 시간차를 복합한 정밀 방향탐지 기술)

  • Lim, Joong-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.11
    • /
    • pp.5208-5213
    • /
    • 2011
  • In this paper, we proposed a new direction finding(DF) technology using TDOA(time-difference of arrival) and PDOA(phase difference of arriving signal) method. The proposed technology has a good DF accuracy without DF ambiguity. TDOA or PDOA technology is used to the most of intelligence systems in 21 century. The principle of TDOA is to receive a signal with two parallel antennas, measure the time difference of arrival signal, and converse the time difference to the direction of incident signal. Those technology make a DF system small size but the DF accuracy is low into short antenna installation distance. The principle of PDOA is similar to TDOA except measuring the phase difference of arrival signal, These technology get a good DF accuracy in short antenna installation distance but have a DF ambiguity. The proposed DF method is simulated into DF system operation environment with noise, and has a good DF accuracy.

Extraction or gaze point on display based on EOG for general paralysis patient (전신마비 환자를 위한 EOG 기반 디스플레이 상의 응시 좌표 산출)

  • Lee, D.H.;Yu, J.H.;Kim, D.H.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.5 no.1
    • /
    • pp.87-93
    • /
    • 2011
  • This paper proposes a method for extraction of the gaze point on display using EOG(Electrooculography) signal. Based on the linear property of EOG signal, the proposed method corrects scaling difference, rotation difference and origin difference between coordinate of using EOG signal and coordinate on display, without adjustment using the head movement. The performance of the proposed method was evaluated by measuring the difference between extracted gaze point and displayed circle point on the monitor with 1680*1050 resolution. Experimental results show that the average distance errors at the gaze points are 3%(56pixel) on x-axis, 4%(47pixel) on y-axis, respectively. This method can be used to human computer interface of pointing device for general paralysis patients or HCI for VR game application.

The Experimental Study on Optical Characteristics of a Detector by Turbidity Variance (탁도 변화에 따른 검출기의 광원특성에 관한 실험적 고찰)

  • Kim, Young-Do;Lee, Kye-Bock
    • The KSFM Journal of Fluid Machinery
    • /
    • v.10 no.6
    • /
    • pp.50-56
    • /
    • 2007
  • In this study, we have performed some experimental works on the effects of variation of low, middle and high turbidity for understanding of optical characteristics which is very important factor for the turbidity measurement. The various output frequencies were obtained by the experimental apparatus which consist of detectors, a light source, a frequency counter and so on. From the result of analysis of these frequencies, Firstly, The difference of signal value for each degrees of low turbidity was the smallest of three scopes around the Nephelometric position. Second, the characteristics of each degrees of middle turbidity was proved that signal values of all degrees were larger those of low turbidity but the difference of each signal value of the forward direction was smaller than that of the backward direction. Third, the characteristics of each degrees of high turbidity was proved that though similar to the characteristics of middle turbidity, each signal value of all degrees was larger and the difference of each signal value of all degrees was smaller than those of low and middle turbidity

A study on the determination of Ultrasonic Travel Time by Norm Phase-Time Method (위상시간법에 의한 초음파전파시간의 결정에 관한 연구)

  • 이은방
    • Journal of the Korean Institute of Navigation
    • /
    • v.18 no.4
    • /
    • pp.137-146
    • /
    • 1994
  • In this paper, a new algorithm to measure the ultrasonic travel time is proposed, which is fundamental to estimate distance depth and volume in several media. Pulse wave has been used to measure travel time of transmitted signal. However, due to the characteristic of transducer and propagation, the received signal is so distorted that it is difficult to measure travel time, which is propagation, the received signal is so distorted that it is difficult to measure travel time, which is to be time difference between transmitted and received signals. In this proposed method, transmitted and received signal are transformed respectively into norm phase newly designed by this paper and displayed on phase-time curve. And travel time is simply determined by the arithmetic numerical mean of time difference at the identical norm phase on the phase-time curves of transmitted and received signals. This method has several features; firstly, travel time is calculated analytically with high accuracy by least square error method, secondly, it is useful to compare the difference of signal magnitude for time information, thirdly, noise and discrete errors are relatively small, finally, the measurement accuracy is not influenced by D.C. bias. In particular, this method is useful and applicable to measuring very short distance and sound speed with high accuracy.

  • PDF

Digital Conversion Error Analysis in a Time-to-Digital Converter (시간-디지털 변환기에서 디지털 변환 에러 분석)

  • Choi, Jin-Ho;Lim, In-Tack
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.10a
    • /
    • pp.520-521
    • /
    • 2017
  • The converted error is occurred by the time difference between the time interval signal and the clock in a Time-to-Digital Converter of counter-type. If the clock period is $T_{CLOCK}$ the converted error is a maximum $T_{CLOCK}$ by the time difference between the start signal and the clock. And the converted error is a maximum $-T_{CLOCK}$ by the time difference between the stop signal and the clock. However, when the clock is synchronized with the start signal and the colck is generated during the time interval signal the range of converted digital error is from 0 to $(1/2)T_{CLOCK}$.

  • PDF

Parametric Array Signal Generating System using Transducer Array (트랜스듀서 배열을 이용한 파라메트릭 배열 신호 생성 시스템)

  • Lee, Jaeil;Lee, Chong Hyun;Bae, Jinho;Paeng, Dong-Guk;Choe, Mi Heung;Kim, Won-Ho
    • The Journal of the Acoustical Society of Korea
    • /
    • v.32 no.4
    • /
    • pp.287-293
    • /
    • 2013
  • We present a parametric array signal generating system using $3{\times}16$ transducer array which is composed of multi-resonant frequency transducers of 20kHz and 32.5kHz. To drive transducer array, sixteen channel amplifier using LM1875 chips is designed and implemented, and the PXI system based on the LabView 8.6 for arbitrary signal generation and analysis is used. Using the proposed system, we measure sound pressure level and beam pattern of difference frequency and verify the nonlinear effect of difference frequency. The theoretical absorption range and the Rayleigh distance are 15.51m and 1.933m, respectively and we verify that sound pressure of difference frequency is accumulated and increased at the near-field shorter than the Rayleigh distance. We verify that the beam pattern of the measured difference frequency and the beam pattern obtained by the superposition of two primary frequencies are similar, and high directional parametric signal was generated.

Analysis of the Difference in Pilot Error by Using the Signal Detection Theory (신호탐지론을 활용한 조종사 Error 차이 분석)

  • Kwon, Oh-Young
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.18 no.1
    • /
    • pp.51-57
    • /
    • 2010
  • This study was to analyze the difference in pilot error by using the Signal Detection Theory. The task was to detect the targeted aircraft(signal) which is different shape from many other aircraft(noise). From the two experiments, we differentiated the task difficulty followed by change in noise stimuli. Experiment 1 was to search the signal stimuli(fighter plane) while the noise stimuli(cargo plane) were increasing. The results from the Experiment 1 showed the tendency to decrease the hit rate by increasing the number of noise stimuli. However, the false alarm rate was not increased. The sensitivity(d') showed quite high. In Experiment 2, a disturbance stimulus(helicopter) was added to noise stimuli. The result was generally similar to those of Experiment 1. However, the hit rate was lower than that of Experiment 1.