• 제목/요약/키워드: difference of air pressure

검색결과 549건 처리시간 0.026초

냉동시스템의 운전조건에 따른 열교환기 내장형 어큐뮬레이터의 성능 특성 (Performance Characteristics of Accumulator Heat Exchangers with Operating Conditions of a Refrigeration System)

  • 강훈;박차식;전종욱;김용찬
    • 설비공학논문집
    • /
    • 제18권12호
    • /
    • pp.984-991
    • /
    • 2006
  • The applications of multi air-conditioners into multiplex and high-rise buildings have been increased by replacing central air-conditioning systems. The pipe length and altitude difference between the indoor and outdoor units can be increased based on installation conditions, which may increase the possibility of flash gas generation at the expansion device inlet. The flash gas generation causes rapid reduction of refrigerant flow rate passing through the expansion device, yielding lower system efficiency. Accumulator heat exchangers have been widely used in multi air-conditioners in order to minimize flash gas generation and obtain system reliability. However, the studies on the heat transfer characteristics and pressure drops of accumulator heat exchangers are very limited in open literature. In this study, the heat transfer rates and pressure drops of accumulator heat exchangers were measured with refrigerant flow rate and operating conditions by using R-22. The heat transfer rate increased with the increase of refrigerant flow rate, while subcooling decreased. The heat transfer rate enhanced with the reduction of inlet superheat and subcooling due to the increased temperature difference between the accumulator and inner heat exchanger.

공기운반분무기용 세라믹 노즐의 미립화 성능 (The Atomization Performance of Ceramic Nozzles in Air Carrier Sprayer)

  • 박석호;노수영
    • Journal of Biosystems Engineering
    • /
    • 제20권3호
    • /
    • pp.236-244
    • /
    • 1995
  • Droplet size is one of the important factors in the deposition and drift of agrichemical application. In this study, droplet size and its distribution of the three different sizes of ceramic hollow cone nozzles being used in the air carrier sprayer for apple production were investigated at the various nozzle pressures and the three air velocities. The Malvern particle size analyzer were used for the measurement of droplet size and its distribution. The important results emerged from th is study can be summarized as follows. 1. Discharged rate was increase with the increase of the nozzle diameter and pressure, amount of the difference was remarkable between the nozzle diameter of 1.0, 1.2 and 1.5 mm, but no difference were found between the diameter of 1.0 and 1.2 mm in the same nozzle pressure. 2. Mass median diameter were varied as 40~160 ${mu}m$ at the air velocity of 0 m/s, 70~140 ${mu}m$ of 15 m/s and 100~160 ${mu}m$ of 20 m/s 3. It appeared that the air velocity range of 15~20 m/s was desirable for both drift and deposition control in the given experimental conditions.

  • PDF

입자 및 필터 대전상태에 따른 입자부하조건에서 공기정화 필터의 여과특성 (Influence of Particle and Filter Charge on Filtration Property of Air Filter under Particle Loading)

  • 지성미;손종렬;박현설
    • 한국대기환경학회지
    • /
    • 제28권6호
    • /
    • pp.644-655
    • /
    • 2012
  • As soon as a new air filter is applied to an air purification process, the filter gets loaded with dust particles. Thus, the study on the particle loading characteristics of air filter is very essential in order to understand the real filtration phenomena during filter use. In this study, we investigated the effect of particle and filter charge on the particle loading property of air filter. Charged filter and uncharged filter prepared by discharging the charged filter by isopropyl alcohol were used as test samples, and three types of particle having different charge states were supplied to filters tested. For neutralized particles there was a big difference in areal mass loading rates between charged and uncharged filters due to the very small amount of particle charge, on the other hand the difference was diminished for atomized particle and finally almost vanished for corona charged particles. The pressure drop of filter loaded with corona charged particles was only half of those for neutralized and atomized particles at the same areal mass loading because of the porous structure of particle deposit formed on filter fibers, caused by the space charge effect between particles.

생물안전 3등급시설의 공기환경 예측 및 공조부하 절감에 대한 해석 (An Analytical Study on the Prediction of Indoor Air Quality and the Reduction of Air Conditioning Load in Bio Safety Level 3 Laboratory)

  • 홍진관;박현진
    • 설비공학논문집
    • /
    • 제24권11호
    • /
    • pp.813-822
    • /
    • 2012
  • In this study, the multizone simulation for biosafety of BSL3 lab. and energy simulation are carried out simultaneously by using linked model of CONTAM and TRNSYS. In BSL3 lab., annual energy consumption is approximately five to ten times more than the magnitude of the office building. This is because required air change rate is extremely large and it is difficult to maintain room pressure difference efficiently. To maintain pressure difference between laboratory rooms through sealing condition of doors and proper airflow control is significant. In this study, to predict indoor environment of the BSL3 lab.(Influenza A research lab.), the multizone simulation for four kinds of biohazard scenario is also performed as part of risk assessment. Multizone and energy simulation results by using linked model show that these approaches are used as a tool for the energy efficient design and operation method for the safer BSL3 lab. facilities.

냉동기 펌프다운 운전성능에 관한 연구 (A Study on Pump Down Operation Performance of Refrigerator)

  • 김철수;정한식;정효민
    • 설비공학논문집
    • /
    • 제18권12호
    • /
    • pp.964-970
    • /
    • 2006
  • Vapor compression refrigerators have much critical variables such as the controls of temperature and pressure switches, control durations and operating hours of electronic valves. This study compares and analyzes the data which is obtained from system controlling of the evaporation temperatures which are generally used in automatic pump down operating systems. Through this study, the automatic evaporation control operation system will be more ideal for the system to keep the proper temperature distribution depending on the purpose of evaporation side. The automatic pump down control operation is more appropriate for the system to aim at the effective use of evaporation side without using the temperature difference. And this test will be proved that the changes at the low pressure side didn't have significant impacts on the high pressure side.

연료전지용 공기공급기의 케이스 변형량 해석 및 개선설계 (Deformation Analysis and Design Modification of the case of the air blower for fuel cell)

  • 제우성
    • 한국기계기술학회지
    • /
    • 제13권4호
    • /
    • pp.43-48
    • /
    • 2011
  • The air blowers for fuel cell electric vehicle usually have big difference between inlet and outlet pressure. When the casing of the air blowers is designed, the stress analysis is required. (Approximately Inlet pressure is 0.5bar and outlet pressure is 2bar.) Gap distance between the casing and the impeller is 0.3mm. Therefore, if the amount of maximum deformation of casing is larger than 0.3mm, impeller crashed the casing. In order to avoid crashing, both the thickness and number of rims are changed and carried out simulations on each cases.

Submarine Cable Measurements of Voltage for Current Monitoring in the-Tsushima and in the Tokara Straits

  • Hashimoto, Yoshio;Tashiro, Akimasa;Shinozaki, Takashige;Ishii, Hiaeo;Kawatate, Kazuo
    • Journal of the korean society of oceanography
    • /
    • 제37권3호
    • /
    • pp.160-168
    • /
    • 2002
  • We have been measuring the voltage differences by using submarine cables in the Tsushima and in the Tokara Straits. The aim of these measurements is to estimate the volume transports of the ocean currents through those straits. In this paper, the voltage differences are compared with the corresponding sea level and air pressure differences between straits. Especially in the Tsushima Strait, the voltage difference is consistent with the air pressure difference as well as the sea level difference.

비유전율을 이용한 공기감지장치에 관한 연구 (A study on the air detector using relative dielectric constant)

  • 이혁수;김청월
    • 센서학회지
    • /
    • 제16권5호
    • /
    • pp.384-388
    • /
    • 2007
  • Air embolism can be a lethal complication of surgical procedures during which venous pressure at the site of surgery is sub-atmospheric or air is forced under pressure into a body cavity. To solve the problem, we developed the air detector using relative dielectric constant change, which is expected to be used broadly in industrial circles. We designed a detection circuit of sensing scheme. In experiments with a mock system, the proposed system showed a signal difference depending on the amount of air in the tygon tube of the mock system.

이젝터 기술을 활용한 주방후드용 기류유인 덕트 시스템의 개발에 관한 연구 (Study on Development of Inducing Airflow Duct System for Kitchen Hood Using Ejector Method)

  • 손유라;홍성규;양정훈
    • 한국태양에너지학회 논문집
    • /
    • 제39권6호
    • /
    • pp.27-40
    • /
    • 2019
  • Kitchen hoods are limited in discharging all contaminants produced during cooking. Contaminants that have not been discharged can rise to the upper part of the kitchen and become stacked. To solve this problem, there is a way to increase the air volume of the kitchen hood, but there are limits, so a new system is required. This study proposes the Duct System (IADK : Inducing Airflow Duct system for Kitchen hood )through 3D printers and experiments. To do this, the pressure is measured to verify the three levels of air volume provided by the kitchen hood. To check the degree of loss of flow in the existing kitchen hood system, install flexible ducts alone to measure the pressure. Change the internal diameter and type of connection of the IADK and measure the pressure. The air pressure, static pressure difference, and loss factor are calculated and analyzed using the pressure measured through the experiment.

공간직물형 에어 인솔의 공기압 차이가 젊은 성인의 균형 능력에 미치는 영향 (Effect of Space Fabric Type Air Insole Pressure difference on Balance to Normal Adults)

  • 김기철;이전형;김상수;남휴형
    • PNF and Movement
    • /
    • 제13권1호
    • /
    • pp.47-53
    • /
    • 2015
  • Purpose: This study examined the effects of space fabric type air insole pressure differences on young adults' dynamic balance ability. Method: The subjects of this study were 17 young female adults without musculoskeletal system disease. Balance ability was measured by dividing the subjects into three groups: an experimental group which did not wear an air insole (insole-off group), an experimental group which wore an air insole to which air pressure of $0.55kg/cm^2$ was applied (insole-0.55 group), and an experimental group which wore an air insole to which air pressure of $0.75kg/cm^2$ was applied (insole-0.75 group). For dynamic balance, the subjects stood on a balance pad, and perimeter length and medium speed were measured three times. The averaged values were recorded and statistically processed. Result: There were significant differences in average speed, and the insole-0.75 group's average speed decreased compared to the insole-off group and the insole-0.55 group. Although the total movement distance did not statistically differ, the insole-75 group's movement distance decreased compared to the insole-off group and the insole-0.55 group. Conclusion: Application of a space fabric type air insole, in particular insole-0.75, was helpful in improving balance ability. This is considered to occur because the space fabric structure was conducive to decreasing sway and producing balance.