• Title/Summary/Keyword: dielectric insulation

Search Result 388, Processing Time 0.022 seconds

Dielectric Properties and Breakdown Strength in Insulation/Semiconductive/Insulation (절연/반도전/절연층에 있어서 유전특성과 절연파괴 현상)

  • 강대용;오광영;김용주;박대회
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.06a
    • /
    • pp.163-166
    • /
    • 1998
  • In this paper, breakdown strength and dielectric characteristics were experimented in the structures of insulation/insulation/insulation and insulation/semiconductor/insulation by using of insulation material of polyethylene terephthalate film. The breakdown strength and the permitivity of each specimen were measured as a function of temperature and frequency respectively. The breakdown strength of PET/PET/PET did not changed greatly but that of PET/SEMl/PEr increased as a function of temperature. As the frequency inclosed, the permitivity of PET/PET/PET and PET/SEMI/PET decreased. The tan $\delta$ of PET/PET/PET showed lower than that of PET/SEMl/PET in low frequency but higher in high frequency .

  • PDF

Analysis on the dielectric characteristics of a composite insulation system composed of LN2 and GN2

  • Kim, Junil;Lee, Onyou;Mo, Young Kyu;Bang, Seungmin;Kang, Jong O;Lee, Hongseok;Nam, Seokho;Kang, Hyoungku
    • Progress in Superconductivity and Cryogenics
    • /
    • v.17 no.3
    • /
    • pp.33-36
    • /
    • 2015
  • A liquid nitrogen ($LN_2$) is usually used to be a coolant and insulant for a HTS coil system. HTS wires for a superconducting apparatus may be surrounded by gaseous nitrogen ($GN_2$) due to film boiling generated by a quench or voids occurred by electrical breakdown. The increased maximum electric field intensity at $GN_2$ may result in the degradation of dielectric strength of a HTS coil system. In this paper, a study on the dielectric characteristics of a composite insulation system composed of $LN_2$ and $GN_2$ is performed. A sphere-to-plane electrode system made with stainless steel is used to perform the experiments under AC and lightning impulse voltage condition. A sphere electrode is surrounded by $GN_2$ and a plane electrode is immersed into $LN_2$ to conduct dielectric experiments with a composite insulation system. The dielectric experiments are performed according to the level of $LN_2$ from the plane electrode to a sphere electrode. It is found that the dielectric characteristics of a composite insulation system are dependent on the level of $LN_2$ and the field utilization factor of an electrode system.

Thermal, Dielectric Properties Characteristics of Epoxy-nanocomposites for Organoclay of Several Types (여러종류의 Organoclay에 대한 에폭시-나노콤포지트의 열적, 유전특성에 관한 연구)

  • Park, Jae-Jun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.6
    • /
    • pp.538-543
    • /
    • 2008
  • Nanostructured materials are attracting increased interest and application. Exciting perspectives may be offered by electrical insulation. Epoxy/Organoclay nanocomposites may find new and upgraded applications in the electrical industry, replacing conventional insulation to provide improved performances in electric power apparatus, e.g, high voltage motor/generator stator winding insulation, dry mold transformer, etc. In the paper work, the electrical and thermal properties of epoxy/organoclay nanocomposites materials were studied. The electrical insulation characteristics were analyzed through the permittivity characteristics. by analyzing the permittivity spectra, it was found that dielectric constant becomes smaller with increase frequency and becomes larger with increase temperature. This indicates restriction of molecular motion and strong bonds at the epoxy/organoclay nanocomposites. The morphology of nanocomposites obtained was examined using TEM and X-ray diffraction. It has been shown that the presence of polar groups leads to an increased gallery distance and partial exfoliation. Nevertheless, full exfoliation of clay platelets has not been achieved.

Investigation on DC Breakdown Strength Characteristics of Power Cable Insulation (전력 케이블 절연재에 대한 DC절연파괴강도특성 고찰)

  • Lee, Han-Joo;Jung, Eui-Hwan;Joe, Sung-Hoon;Yoon, Jae-Hoon;Lim, Kee-Joe
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.86-86
    • /
    • 2010
  • Recently, CV, CNCV, CNCV-W cable are used to transmit and distribute electric power. And a lot of researchers put more effort to realize high performance. The dielectric breakdown strength characteristic is a standard to design insulators. Examination of that is a main factor to determine long term insulation performance, which is used to diagnose Insulation deterioration. In this paper, we prepared XLPE, XLPE/nano-filler, LDPE/nano-filler for comparing each of the dielectric breakdown strength characteristics.

  • PDF

Effect of the Inner Side Dielectric Coating of the Tank on the Particle Movement for Improving of GIS Insulation Reliability (GIS 절연 신뢰성 향상을 위한 탱크 내면 코팅이 파티클 거동에 미치는 영향)

  • Lee, Bang-Wook;Koo, Ja-Yoon;Kim, Min-Kyu;Kim, Ik-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1996.11a
    • /
    • pp.267-269
    • /
    • 1996
  • In this work, the influence of wire type conducting particles on the insulation reliability of GIS has been systematically investigated when outer electrode was dielectric coated by epoxy resin. For this purpose, coaxial cylinder-type electrode was adopted in 362 kV chamber and various size of Cu conducting particle was used and different gas pressure was applied. To prove the coating effect on the gas insulation, different thickness of epoxy coated outer electrode have been considered and the lift-off voltage and flashover voltage have been analyzed. The results show that the dielectric coated electrode has an remarkable influence on the reducing particle behavior in GIS system and enhancing the GIS insulation reliability.

  • PDF

Influence of Tank Inner Side Dielectric Coating on the Particle Behaviour and Flashover Voltage in SF\ulcorner Gas Insulated System

  • Lee, Bang-Wook;Koo, Ja-Yoon
    • Journal of Electrical Engineering and information Science
    • /
    • v.2 no.3
    • /
    • pp.77-81
    • /
    • 1997
  • In his work, the influence of wire type conducting particles on the insulation reliability of GIS has been systematically investigated when the epoxy resin based dielectric coating was made on he inner side of outer electrode. For this purpose, coaxial cylinder-type electrode was adopted in 362 kV chamber and various sizes of Cu conducting particle were used under different gas pressures. In order to elucidate the coating effect on the gas insulation, different thickness of dielectric coating has been considered and then the lift-off voltage and flashover voltages have been measured. The results shown that the dielectric coating has a remarkable influence by restraining the movement of particle in GIS system, and thus GIS insulation reliability is noticeably improved.

  • PDF

Characteristics of Insulation Diagnosis and Failure in Gas Turbine Generator Stator Windings

  • Kim, Hee-Dong
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.280-285
    • /
    • 2014
  • In order to evaluate the insulation deterioration in the stator windings of five gas turbine generators(137 MVA, 13.8 kV) which has been operated for more than 13 years, diagnostic test and AC dielectric breakdown test were performed at phases A, B and C. These tests included measurements of AC current, dissipation factor, partial discharge (PD) magnitude and capacitance. ${\Delta}I$ and ${\Delta}tan{\delta}$ in all three phases (A, B and C) of No. 1 generator stator windings showed that they were in good condition but PD magnitude indicated marginally serviceable and bad level to the insulation condition. Overall analysis of the results suggested that the generator stator windings were indicated serious insulation deterioration and patterns of the PD in all three phases were analyzed to be internal, slot and spark discharges. After the diagnostic test, an AC overvoltage test was performed by gradually increasing the voltage applied to the generator stator windings until electrical insulation failure occurred, in order to determine the breakdown voltage. The breakdown voltage at phases A, B and C of No. 1 generator stator windings failed at 28.0 kV, 17.9 kV, and 21.3 kV, respectively. The breakdown voltage was lower than that expected for good-quality windings (28.6 kV) in a 13.8kV class generator. In the AC dielectric breakdown and diagnostic tests, there was a strong correlation between the breakdown voltage and the voltage at which charging current increases abruptly ($P_{i1}$, $P_{i2}$).

Electrical and Mechanical Properties of Epoxy/Heterogeneous Inorganic Composites Materials for the Application of Electric Power GIS Appliances (친환경 GIS용 전력기기의 적용을 위한 에폭시 이종무기물 복합재료의 전기적, 기계적 특성)

  • Park, Jae-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.12
    • /
    • pp.1633-1640
    • /
    • 2018
  • Epoxy resin is a polar thermosetting polymer that is widely employed in different branches of industry and everyday life, due to their stable physical and chemical properties. Of all the polymer materials currently being used in the electrical insulation industry, epoxy resin is the most widely used kind, chosen as the base polymer material in the present study. Composites were prepared according to the mixing ratio (MS: MA, 1: 9, 3: 7, 5: 5, 7: 3, 9: 1)of mixture for Heterogeneous Minerals(Micro Silica:MS, Micro Alumina:MA) (MS+MA). We have investigated for AC electrical insulation breakdown characteristics and the dielectric properties (permittivity, dielectric loss, and conductivity) with frequency changes. The electrical AC insulation breakdown performance was improved with the increase of the mixing ratio of MS according to heterogeneous mineral material mixture(MS+MA). As Dielectric properties, the dielectric constant and dielectric loss increased with decreasing frequency and decreased with increasing MS content ratio of heterogeneous mineral mixture. Tensile strength and flexural strength according to the mixing ratio (MS + MA) of epoxy / heterogeneous mineral mixture were studied by mechanical properties. The performance of mechanical tensile and flexural strength was significantly improved as the fill contents ratio of MS increased.

Development and Evaluation of Epoxy VPI Insulation for High Voltage Rotating Stator Windings (고압회전기 권선용 에폭시 VPI 절연물의 개발과 평가)

  • Lee, Chang-Ryong;Choi, Yong-Chan
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05d
    • /
    • pp.38-42
    • /
    • 2003
  • The use of VPI impregnated mica tape as high voltage insulation for large rotating electric machines requires a careful balance of processes and materials to obtain the desired electrical, mechanical and thermal characteristics. The stator insulation systems such as epoxy bonded high voltage mica tape have been produced for many years. One such system employing an epoxy and anhydride impregnating resin developed by Hyundai Heavy Industries, Co. (hereafter, HHI), to satisfy customer requests for an epoxy bonded insulation system. HHI applies the following electrical and thermal evaluations such as dielectric breakdown, voltage endurance, dissipation factor vs. temperature, isothermal weight loss, and so on. A detailed laboratory evaluation can describe specific physical limitations for an insulation system and permit development of long-term operation guidelines that permit full utilization of the proposed system. HHI has found these evaluations very helpful in qualifying insulation system for the repair of both large motors and generators.

  • PDF

Insulation Performance Estimation of Main Relays by Partial Discharges (부분방전에 의한 주계전기의 절연성능 평가)

  • Kil, Gyung-Suk;Kim, Il-Kwon;Park, Dae-Won;Song, Jae-Yong;Lee, Gang-Won;Cho, Eun-Je
    • Journal of the Korean Society for Railway
    • /
    • v.10 no.4
    • /
    • pp.388-392
    • /
    • 2007
  • A new dielectric test on main relays of electric traction vehicles, the partial discharge(PD) test, is proposed. The PD test will not affect the insulation performance of specimen during the test and provide much more detailed information on insulation, the types of defects, and so on. Insulation performance of relays is estimated by discharge inception voltage(DIV), discharge extinction voltage (DEV), and apparent charge as a function of test voltage and time. Three main relays of different manufacturing date were estimated by applying AC voltage with three patterns in ranges of $0{\sim}1,200[V]$. From the results, we could estimate insulation state and which types of defects exist in them.