• 제목/요약/키워드: dielectric breakdown strength

검색결과 253건 처리시간 0.031초

PET 필름의 전기적 특성에 미치는 계면효과 (The Effects of Interfacial on the Electrical Properties in PET Films)

  • 강무성;이창훈;박수길;박대희
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권5호
    • /
    • pp.281-284
    • /
    • 1999
  • In this paper, the electrical conduction, breakdown strength and dielectric properties were investigated in the interfaces of PET films. The volume resistivity and breakdown strength were decreased; especially the specimens with semiconductive layer showed the lowest breakdown strength. This decrease of electrical properties was appeared by increasing charge density in inhomogeneous layer of PET. The dielectric properties of PET did not show significant difference with PET/PET but the films with semiconductive interface layer showed the increase in capacitance and $tan\delta$ was affected by the PET rather than semiconductive layer. It is assumed that the variation of $tan\delta$ was affected by the dielectric polarization and the leakage current(charge).

  • PDF

카본블랙 첨가 PMC(Polyethylene Matrix Composites)의 문턱스며들기(Percolation Threshold)와 절연파괴 강도 임계지수 (Percolation Threshold and Critical Exponent of Dielectric Breakdown Strength of Polyethylene Matrix Composites added Carbon Black)

  • 신순기
    • 한국재료학회지
    • /
    • 제21권9호
    • /
    • pp.477-481
    • /
    • 2011
  • Composites of insulating polyethylene and carbon black are widely used in switching elements, conductive paint, and other applications due to the large gap of resistance value. This research addresses the critical exponent of dielectric breakdown strength of polymer matrix composites (PMC) made with carbon black and polyethylene below the percolation threshold (Pt) for the first time. Here, Pt means the volume fraction of carbon black of which the resistance of the PMC is transferred from its sharp decrease to gradual decrease in accordance with the increase of carbon-black-filled content. First, the Pt is determined based on the critical exponents of resistivity and relative permittivity. Although huge cohesive bodies of carbon black are formed in case of being less than the Pt, a percolation path connecting the conducting phases is not formed. The dielectric breakdown strength (Dbs) of the PMC below Pt is measured by using an impulse voltage in the range from 10 kV to 40 kV to avoid the effect of joule heating. Although the observed Dbs data seems to be well fitted to a straight line with a slope of 0.9 on a double logarithm of (Pt-$V_{CB}$) and Dbs, the least squares method gives a slope of 0.97 for the PMC. It has been found that finite carbon-black clusters play an important role in dielectric breakdown.

개질된 에폭시 수지계의 불평등 전계하에서 절연특성 (Dielectric Properties of Modified Epoxy Resins under Inhomogeneous Electric Field)

  • 안현수;심미자;김상욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1585-1587
    • /
    • 1996
  • The dielectric properties of DGEBA/MDA/GN system under inhomoneous electric field were investigated. As GN contents increased, impact strength increased, but dielectric breakdown strength decreased. At $150^{\circ}C$, the dielectric breakdown strength decreased and uniformly maintained with the increment of distance between two electrodes. The life-time of epoxy resin increased with the decrement of applied voltage, but dielectric breakdown didn't occur below specific applied voltage.

  • PDF

전도채널을 갖는 뼈와 유사한 재료의 절연파괴 해석 (Dielectric Breakdown Analysis of Bone-Like Materials with Conductive Channels)

  • 이보현;;범현규
    • 대한기계학회논문집A
    • /
    • 제35권6호
    • /
    • pp.583-589
    • /
    • 2011
  • 순수한 전기장 하에서의 뼈와 유사한 재료의 절연파괴에 대하여 연구하였다. 일반적으로 뼈와 유사한 재료는 강한 유전강도를 가지는 층과 약한 유전강도를 가지는 층이 서로 평행하게 엇갈려 있는 형태로 구성되어 있다. 뼈와 유사한 재료의 약한 층을 관통하는 전도채널의 성장은 전기장의 집중이 완화되기 때문에 지연된다. 관형채널의 선단에서 전기장의 분포를 유한요소해석을 통해 구하였다. 뼈와 유사한 재료의 절연강도를 J 적분을 사용하여 계산하였고, 절연강도에 영향을 미치는 인자들을 찾아내었다. J 적분은 약한 층에서의 절연파괴 면적이 증가할 수록 작아짐을 보였다. 또한, 약한 층과 강한 층의 유전율의 비가 절연파괴에 큰 영향을 미치는 것으로 나타났다.

22-9kV급 XLPE 시이트의 유전특성과 계면효과 (Interface Effects and Dielectric Properties of 22.9kV XLPE sheets)

  • 이관우;이종복;황보승;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 추계학술대회 논문집
    • /
    • pp.441-444
    • /
    • 2000
  • In this paper, dielectric properties of XLPE sheets of 22kV cable with semiconducting and water were investigated. The breakdown strength of XLPE under rod/needle electrode were measured at without oil. It is found that the dielectric properties such tan$\delta$ of XLPE sheet dependence on semiconducting and water layer and are decreased much lower increase with temperature. The breakdown strength and the electrode effect are obtained as a function of thickness, and a equation for the sheet thickness dependent breakdown strength is also discussion.

  • PDF

2,3 성분 상호침입망목 에폭시 복합재료의 절연 파괴 특성에 관한 연구 (A study on the dielectric breakdown properties of two and three interpenetrating polymer network epoxy composites)

  • 김명호;김경환;손인환;이덕진;장경욱;김재환
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제9권4호
    • /
    • pp.364-371
    • /
    • 1996
  • In this study, in order to investigate the applicability of IPN structure to epoxy resin which has been widely used as electrical and electronic insulating materials, DC dielectric breakdown properties and morphology were compared and analyzed according to variation of network structure, using the single network structure specimen formed of epoxy resin alone, interpenetrating polymer network specimen formed of epoxy resin/methacrylic acid resin, and interpenetrating polymer network specimen formed of epoxy resin/methacrylic acid resin/polyurethane resin. As results of the measunnent of DC dielectric breakdown strength at 50[.deg. C] and 130[>$^{\circ}C$], IPN specimen formed of epoxn, resin 100[phr] and methacrylic acid resin 35[phr] was the most excellent, and which corresponded to the SEM phenomena. The effect of IPN was more remarkable at high temperature region than at low temperature region. It is supposed that the defect of epoxy resin, dielectric breakdown strength is lowered remarkably at high temperature region, be complemented according to introducing IPN method.

  • PDF

전기설비용 에폭시-$SiO_2$ 복합재료의 절연파괴 특성에 관한 연구 (A Study on the Dielectric Breakdown Strength Characteristics of Epoxy-$SiO_2$ Compound Material for Electric Installation)

  • 김재환;박창옥
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제5권2호
    • /
    • pp.77-83
    • /
    • 1991
  • 비스페놀 A형 에폭시 수지에 $SiO_2$를 충진한 에폭시 복합재료의 단시간 절연파괴 특성을 충진제 첨가 함량의 변화, 주위온도(상온~[$190^{\circ}C$])의 변화 및 인가 전원의 종류별로 연구, 검토하였다. 연구결과, 절연파괴강도는 충진제 함량의 증가에 대해 일반적으로 감소하는 경향을 보였으며, 입자간 중심거리 d가 충진제함량이 증가함에 따라 감소하여 평균입자간격이 [$7.5\mu\textrm{m}$]이하가 되면 절연파괴 강도가 거의 일정한 값이 됨을 확인하였다. 또한, 교류전압을 인가하는 경우는 고온영역 ([$130^{\circ}C$]) 이상에서 충진된 에폭시수지가 무충진 에폭시수지보다 절연파괴강도가 증가하였다.

  • PDF

유입변압기용 절연유의 절연파괴특성 (Electrical Breakdown Properties of Insulating Oils for oil-immersed transformer)

  • 이인성;신현택;이종필;이수원;홍진웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집
    • /
    • pp.605-608
    • /
    • 2001
  • With the intention of investigating the breakdown properties of oil-immersed transformer oils in temperature range of 20∼100[$^{\circ}C$], we are made researches AC breakdown in the gap of 500∼2,500[$\mu\textrm{m}$]. The classification for the physical properties of oil for oil-immersed transformer by FTH and $^1$H-NMR experiments was confirmed to type of mineral oils. As the dependance of breakdown properties due to electrode gap length variation, breakdown voltage was found increasing according to the increase of gap, while dielectric strength was decreasing. As a result the characteristics for AC breakdown, It goes to prove that the breakdown voltage was increased to 90[$^{\circ}C$] but decreased over 90[$^{\circ}C$] in the temperature range. Also, breakdown voltage was found increasing in the increase of gap and the rising of temperature according to Weibull distribution.

  • PDF

고온초전도 DC 케이블 시스템용 PPLP 및 GFRP의 절연 특성 (Dielectric Breakdown Characteristics of PPLP and GFRP for HTS DC Cable System)

  • 김상현;최재형;김우진;장현만;이수길
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제13권3호
    • /
    • pp.5-9
    • /
    • 2011
  • DC high-temperature superconducting(HTS) cable system has attracted a great deal of interest from the view point of low loss, dense structure and large capacity. A HTS cable system is made of cable and termination. The insulating materials and insulation technology must be solved for the long life, reliability and compact of cable system. In this paper, we will report on the dielectric breakdown characteristics of insulating materials for HTS cable and termination. The AC, DC and lightning impulse breakdown strength of laminated polypropylene paper(PPLP) and glass fiber reinforced plastic(GFRP) have been measured under nitrogen pressures in the range of 0.l-0.4MPa. PPLP and GFRP are found to have a significantly higher DC breakdown strength. Also, DC surface flashover voltage of negative polarity is slightly higher than that of positive polarity in GFRP.

와이블 분포식을 이용한 에폭시 복합체의 절연 신뢰도 분석 (Analysis of Insulating Reliability in Epoxy Composites using Weibull Distribution Equation)

  • Park, No-Bong;Lim, Jung-Kwan;Park, Yong-Pil
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2003년도 춘계종합학술대회
    • /
    • pp.813-816
    • /
    • 2003
  • The dielectric breakdown of epoxy composites used for transformers was experimented and then its data were applied to Weibull distribution probability. First of all, speaking of dielectric breakdown properties, the more hardener increased, the stronger breakdown strength became at low temperature because of cross-linked density by the virtue of ester radical. The breakdown strength of specimens with filler was lower than it of non-filler specimens because it is believed that the adding filler forms interface and charge is accumulated in it, therefore the molecular motility is raised and the electric field is concentrated. In the case of filled specimens with treating silane, the breakdown strength become much higher. Finally, according to Weibull distribution analysis, reducing breakdown probability of equipment insulation lower than 0.1 % level requires the allowable field intensity values to be kept under 21.5 MV/cm.

  • PDF