• Title/Summary/Keyword: dicom

Search Result 253, Processing Time 0.02 seconds

Finite Element Analysis of Wrist Orthosis with 3D Printing (3D 프린트를 통해 제작된 손목 보조기의 유한요소해석)

  • Choi, Hyeun-Woo;Kang, Inyeong;Noh, Gunwoo;Seo, Anna;Lee, Jong-Min
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.7
    • /
    • pp.947-953
    • /
    • 2019
  • The purpose of this study was to manufacture a wrist brace using a computerized tomography system, clinical design software (MediACE 3D Program), and 3D printer. After acquiring the Dicom file of the upper limb with a computed tomography, the wrist brace was designed using the MediACE 3D Program to create a "stereolithography" file. The designed wrist brace was printed using a 3D printer. To verify the effectiveness of wrist assistive device manufactured by 3D printing technology, the stress distribution of the pressure and orthosis applied to bone and skin is represented by finite element analysis. It is expected that the wrist brace can be manufactured by reinforcing the part where the damage caused by pressure and breakage of the brace frequently occurs with the result of finite element analysis when producing the wrist brace.

Depending on PACS Operating System Differences Analysis of Usefulness of Lossless Compression Method in Medical Image Upload: SNR, CNR, Histogram Comparative Analysis (PACS운영 시스템 차이에 따른 의료 영상 업로드 시 무손실 압축 방식의 유용성 분석: SNR, CNR, Histogram 비교 분석을 중심으로)

  • Choi, Ji-An;Hwang, Jun-Ho;Lee, Kyung-Bae
    • The Journal of the Korea Contents Association
    • /
    • v.18 no.3
    • /
    • pp.299-308
    • /
    • 2018
  • This study focused on the fact that medical images that are issued at different hospitals may affect image quality on PACS when different software is used. A university hospital image was copied to the DICOM file and registered on the PACS of the university hospital B. The capacity and image quality of the software used in the university hospital were evaluated by SNR, CNR and histogram. As the compression ratio increased, SNR and CNR tended to decrease. Note that Lossless Compression decreased the data size by half compared to No Compression, but SNR and CNR did not change. As a result of the histogram analysis, the information loss due to the underflow phenomenon was conspicuous. When moving to another hospital, No compression or lossless compression method should be used. In conclusion, it is useful to use the lossless compression method, considering waiting time and economic efficiency in uploading.

Evaluation of Usefulness and Availability for Orthopedic Surgery using Clavicle Fracture Model Manufactured by Desktop 3D Printer (보급형 3D 프린터로 제작한 쇄골 골절 모델을 이용한 정형외과 수술에 대한 유용성과 활용가능성 평가)

  • Oh, Wang-Kyun
    • Journal of radiological science and technology
    • /
    • v.37 no.3
    • /
    • pp.203-209
    • /
    • 2014
  • Usefulness and clinical availability for surgery efficiency were evaluated by conducting pre-operative planning with a model manufactured by desktop 3D printer by using clavicle CT image. The patient-customized clavicle fracture model was manufactured by desktop 3D printer of FDM wire laminated processing method by converting the CT image into STL file in Open Source DICOM Viewer Osirix. Also, the model of the original shape before damaged was restored and manufactured by Mirror technique based on STL file of not fractured clavicle of the other side by using the symmetry feature of the human body. For the model, the position and size, degree of the fracture was equally printed out. Using the clavicle model directly manufactured with low cost and less time in Department of Radiology is considered to be useful because it can reduce secondary damage during surgery and increase surgery efficiency with Minimal invasive percutaneous plate osteosynthesis(MIPO).

A New Method for Measuring the Dose Distribution of the Radiotherapy Domain using the IP

  • Homma, Mitsuhiko;Tabushi, Katsuyoshi;Obata, Yasunori;Tamiya, Tadashi;Koyama, Shuji;Kurooka, Masahiko;Shimomura, Kouhei;Ishigaki, Takeo
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.237-240
    • /
    • 2002
  • Knowing the dose distribution in a tissue is as important as being able to measure exposure or absorbed dose in radiotherapy. Since the Dry Imager spread, the wet type automatic processor is no longer used. Furthermore, the waste fluid after film development process brings about a serious problem for prevention of pollution. Therefore, we have developed a measurement method for the dose distribution (CR dosimetry) in the phantom based on the imaging plate (IP) of the computed radiography (CR). The IP was applied for the dose measurement as a dosimeter instead of the film used for film dosimetry. The data from the irradiated IP were processed by a personal computer with 10 bits and were depicted as absorbed dose distributions in the phantom. The image of the dose distribution was obtained from the CR system using the DICOM form. The CR dosimetry is an application of CR system currently employed in medical examinations to dosimetry in radiotherapy. A dose distribution can be easily shown by the Dose Distribution Depiction System we developed this time. Moreover, the measurement method is simpler and a result is obtained more quickly compared with film dosimetry.

  • PDF

Extract and Analysis System for CT/MRI Images (CT/MRI 영상에서의 이미지 추출-분석 시스템)

  • Kwak, Ho-Young;Huh, Jisoon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.19 no.1
    • /
    • pp.131-140
    • /
    • 2014
  • TMost of the medical images that are being used today are to confirm the existence of lesions. These kind of medical images can not only be used to confirm lesions but if we could use it for academic studies or for analysis and reference materials for surgical operations, it could offer great help in medical studies. Furthermore, we could reduce the number of errors in treatment through simulations in the surgical operations and treatments. In this paper, the necessary parts regarding the medical image visuals were extracted through the point cloud and by using the information obtained through it, it manufactures the necessary information for academic studies, diagnoses or operations. By designing and realizing the system which makes simulation possible with the manufactured information, the paper attempts to provide a more effective way to approach academic studies or giving appropriate diagnoses in the treatment of patients.

RNSXI(real-name shooting X-ray of inspector) Settlement Realization applying PACS Database, In Digital Medical environment (PACS Database를 활용한 촬영실명제 정착화 실현)

  • Kang, Ji-Youn;Lee, Lae-Gon;Kang, Doo-Hee;Lee, Hwa-Sun;Hwang, Sun-Gwang
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.9 no.2
    • /
    • pp.5-9
    • /
    • 2007
  • As developing the medical treatment image portion with the change of these times, PACS, which is able to digitalize image portion data, has a lot of data-based image data. Applying this PACS, we would like to settle down RNSXI(real-name shooting X -ray of inspector) system. We interviewed with P ACS's operators of university hospitals which is using PACS in Seoul about the present conditions whether using of RNSXI or not. And we inquired the RNSXI equipments, applying PACS database, and Interface conditions undertook to do in our hospital. All university hospitals in Seoul are set up the P ACS system. But no hospital use the RNSXI. In our hospital, we can check inspector' name or initials who exposure x-ray with the PACS Viewer by looking over equipments(CR, DR, US, MG, MR, CT) and Interface of the DICOM Header data. However, some equipments like RF and Angio can not check inspector' name or initials. Under the Film/System environment, RNSXI system has been used frequently like that inspector's signature or initial added to a patient data. Though the digital medical treatment was developed, RNSXI system was declined. It is necessary to using RNSXI system in order to improving radiologists' rights, even if it is not under the application of the medical treatment image laws. If RNSXI system use, radiologists should specialize in their major and the Repeat rate should be reduced. In environment of PACS, RNSXI system can be used by linking both the equipments and the Interface with a production enterprise of P ACS. Therefore RNSXI system applying the P ACS datebase should settle down in our medical system for being provided lots of data.

  • PDF

The Difference of the Changes of Images on Ultrasound Scanner Setting Parameters

  • Kang, Hae-Kyung;Kim, Youn-Min;Kim, Hyun-Soo;Lee, Sung-Hee;Cho, Se-Youn;Lyu, Young-Eun;Jung, In-A
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.12 no.2
    • /
    • pp.81-87
    • /
    • 2010
  • The setting parameters of ultrasound scanner give influences to change of image. Sonographers have used a Matlab program to make Low Contrast Sensitivity(LCS) value and compared original images in order to evaluate the use of the supersonic diagnosis machinery. We confirmed the change of image in Grayscale values using Photoshop program. Experiment equipment of our research used A Medison Accuvix V10, A Multi-Tissue Ultrasound Phantom(040 GSE) of CHRIS Company, A Adobe Photoshop CS4 Program, A Convex Probe, A USB memory stick, A Probe Fixation Equipment. The method used Gain, Dynamic Range(DR) of the setting parameters of ultrasound scanner and researched Gain and DR was set to 10 dB. We changed the different settings to see the changes of images using Grayscale values of a Photoshop program about tissue images of a phantom. This study evaluated DR and Gain whether it is an image controller to get the optimum contrast to produce an image to see the how effect on the images. We did not use Gateway in supersonic diagnosis machinery. We can easily open to open the files through Photoshop program before we get Digital Imaging and Communications in Medicine(DICOM) files use USB memory stick in supersonic diagnosis machinery. When we diagnosed the lesion of the patient with ultrasound, the contrast and the Gray scale value of image are very important. In this research, we determined the optimum setting parameters that provided useful information to diagnose disease and evaluated the change of improved images.

  • PDF

Efficiency Comparison of Radiological Work in the integration environment of PACS and OCS (PACS와 OCS연동으로 인한 방사선사 업무의 효율성 비교)

  • Yoo, Eun-Jeong;Kang, Hye-Keong;Kim, Kyeong-Joon;Ahn, Soo-Hyeon;Ahn, Tae-Hun;Lee, Ki-Hyeob;Choi, Hong-Joon;Kim, Seung-Sik
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.5 no.1
    • /
    • pp.86-92
    • /
    • 2002
  • Information concerning a patient visit is to be sent from the OCS(Order Communication System) to the PACS(Picture archiving and Communication System) and when the image acquisition is completed, information regarding the procedures also actually preformed should be sent back to the OCS. It should be possible to present related medical information from the OCS at the same image workstation in a coherent way with the images in the PACS, Examples of the related medical information are: the report of a diagnostic image procedure, data on medication, laboratory results, admission and discharge letters, and surgery reports, because we could maximize the efficiency of Radiological Work, like decrease examination time and human mistakes, though the integration of PACS and OCS, Therefore, We research some hospitals to find integral lists of PACS and OCS but there are no sufficient ingredients. Further, the percentage of Integral lists of PACS and OCS is different in all hospitals because there is no such standard yet like HL7(Healthcare Level 7) and DICOM(Digital Imaging and Communications in Medicine). Accordingly, if all hospital would follow national standard like HL7 and DICOM, the integration of OCS and PACS would be efficient but in this situation radiological technician should take part in construction integration system of PACS and OCS positively, so we could improve efficiency of radiological work and our status.

  • PDF

The Development of Image Processing System for Medical Robot Remote Application (의료용 로봇 원격 응용을 위한 영상처리 시스템 개발)

  • Kim, Joo Young;Kim, Joong Hyuk;Kim, Jung Chae;Kim, Kee Deog;Yoo, Sun K.
    • Progress in Medical Physics
    • /
    • v.23 no.4
    • /
    • pp.239-251
    • /
    • 2012
  • In this paper, web-base image processing system has been implemented for remote-controlled medical robot applications. The developed software system was hierarchically composed of diverse image processing and remote operation modules, and the hierarchical composition was satisfied the expandability to higher level application and the accessibility over the web. It can also support diverse file formats including DICOM, VRML, and CAD(STL) to display, transmit, store and share the processed images depending on application environment. Message-based data exchange, object-oriented module and open-source based software configuration will enable the dynamic combination associated with diverse remote medical application requirements.

Evaluation of Usefulness of Automatic Exposure Control (AEC) by Comparison Analysis of Entrance Surface Dose (ESD) and Entropy in Clinical Application of Digital Radiography (DR) (디지털 방사선 시스템의 노출 유형에 따른 임상 적용 시 입사표면선량 및 Entropy 비교분석을 통한 자동노출제어장치의 유용성 평가)

  • Choi, Ji-An;Hwang, Jun-Ho;Lee, Kyung-Bae
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.8
    • /
    • pp.276-283
    • /
    • 2019
  • The purpose of this study is to evaluate the usefulness of automatic exposure control (AEC) by analyzing entrance surface dose (ESD) and entropy on using automatic exposure and manual exposure. The experimental method was to measure the dose by placing a semiconductor dosimeter on the Rando Phantom for the Pelvis, Abdomen, Skull, and Chest regions. The DICOM file was simultaneously acquired and then entropy was analyzed by using Matlab. As a result, when using the automatic exposure control, dose of all sites was lower than manual exposure's dose and entropy was high. In addition, paired t-test was performed for each item and p<0.05 was found in each item. In conclusion, the use of automatic exposure control can be a useful method to contribute to the optimization of the exposure dose and the image quality by reducing the amount of unnecessary radiation amount and information loss that can occur in X-ray examination.